1.Efficacy analysis of a novel inguinal tourniquet for compression hemostasis
Peng-Fei LIU ; Hao SUN ; Meng-Jie DOU ; Ya-Hua LIU ; Shao-Bin CHAI ; Si-Yu CHEN ; Fa-Qin LYU ; Wei CHEN
Medical Journal of Chinese People's Liberation Army 2025;50(6):688-694
Objective To assess the efficacy of a novel inguinal tourniquet in healthy individuals and to investigate the relationship between localized inguinal compression and femoral artery blood flow occlusion.Methods A self-controlled study was conducted.From November 9 to November 30,2024,11 volunteers were recruited at the Third Medical Center of Chinese PLA General Hospital.Three compression methods--finger pressure,a novel groin tourniquet,and a SAM junction tourniquet(SJT)—were applied bilaterally to the inguinal region until distal blood flow signals disappeared.Each compression method was tested in 22 trials with a 5-minute interval between operations.Differences in hemostatic efficacy between bilateral inguinal regions and across compression methods were compared.Subsequently,the novel tourniquet was incrementally pressurized in 120 mmHg multiples using an integrated pressure device to analyze trends in popliteal artery blood flow velocity.Observational indicators included the internal pressure of the tourniquet pressurization device,peak systolic velocity(PSV)of popliteal artery,inguinal surface pressure magnitude,inguinal surface pressure distribution,and pain scores(assessed using a single-dimensional numerical rating scale).Results No statistically significant difference was observed in the minimum pressure required to occlude femoral artery blood flow bilaterally(P>0.05).The success rates of femoral artery blood flow occlusion at the inguinal region were 100%for the novel inguinal tourniquet,SJT,and finger pressure.The novel inguinal tourniquet induced the highest pain scores,ranging from 5 to 8.A significant reduction in PSV of popliteal artery was noted when the intra-tourniquet pressure reached 360 mmHg and 480 mmHg(P<0.05),with a 95%hemostasis efficacy observed within the range of 360-600 mmHg.No significant association was observed between the recovery of popliteal artery blood flow after limb movement and inguinal pressure distribution(P>0.05).The PSV of popliteal artery exhibited the strongest negative correlation with the average pressure within the inguinal compression area(r=-0.79,P<0.001),with a linear regression fitting line of y=69.69-0.13x(P<0.001,R2=0.58).Conclusions The novel inguinal tourniquet effectively occludes femoral artery blood flow within a pressure range of 360-600 mmHg,accompanied by moderate-to-severe pain.Its hemostatic mechanism mainly relies on increasing the mean pressure within the inguinal compression area.
2.Clinical effects of free latissimus dorsi myocutaneous flap combined with artificial dermis and split-thickness skin graft in the treatment of degloving injury in lower extremity.
Jian Wu QI ; Shao CHEN ; Bin Hong SUN ; Yi Tong CHAI ; Jian HUANG ; Yi LI ; Ke Yue YANG ; He Yang SUN ; Hong CHEN
Chinese Journal of Burns 2022;38(4):347-353
Objective: To observe the clinical effects of free latissimus dorsi myocutaneous flap combined with artificial dermis and split-thickness skin graft in the treatment of degloving injury in lower limbs. Methods: A retrospective observational study was conducted. From December 2017 to December 2020, 8 patients with large skin and soft tissue defect caused by degloving injury in lower extremity were admitted to Ningbo No.6 Hospital, including 5 males and 3 females, aged from 39 to 75 years, with wound area of 25 cm×12 cm-61 cm×34 cm. The free latissimus dorsi myocutaneous flap with latissimus dorsi muscle in the width of 12-15 cm and flap area of 20 cm×8 cm-32 cm×8 cm was used to repair the skin and soft tissue defect of bone/tendon exposure site or functional area. The other defect was repaired with bilayer artificial dermis, and the flap donor site was sutured directly. After the artificial dermis was completely vascularized, the split-thickness skin graft from thigh was excised and extended at a ratio of 1∶2 to 1∶4 and then transplanted to repair the residual wound, and the donor site of skin graft was treated by dressing change. The survival of latissimus dorsi myocutaneous flap, artificial dermis, and split-thickness skin graft after operation was observed, the interval time between artificial dermis transplantation and split-thickness skin graft transplantation was recorded, and the healing of donor site was observed. The appearance and function of operative area were followed up. At the last outpatient follow-up, the sensory recovery of flap was evaluated by British Medical Research Council evaluation criteria, the flap function was evaluated by the comprehensive evaluation standard of flap in Operative Hand Surgery, the scar of lower limb skin graft area and thigh skin donor area was evaluated by Vancouver scar scale, and the patient's satisfaction with the curative effects was asked. Results: The latissimus dorsi myocutaneous flap survived in 6 patients, while the distal tip of latissimus dorsi myocutaneous flap was partially necrotic in 2 patient and was repaired by skin grafting after resection at split-thickness skin grafting. The artificial dermis survived in all 8 patients after transplantation. The split-thickness skin graft survived in 7 patients, while partial necrosis of the split-thickness skin graft occurred in one patient and was repaired by skin grafting again. The interval time between artificial dermis transplantation and split-thickness skin graft transplantation was 15-26 (20±5) d. The donor site of latissimus dorsi myocutaneous flap healed with linear scar after operation, and the thigh skin graft donor site healed with scar after operation. The patients were followed up for 6-18 (12.5±2.3) months. The color and elasticity of the flap were similar to those of the surrounding skin tissue, and the lower limb joint activity returned to normal. There was no increase in linear scar at the back donor site or obvious hypertrophic scar at the thigh donor site. At the last outpatient follow-up, the sensation of the flap recovered to grade S2 or S3; 3 cases were excellent, 4 cases were good, and 1 case was fair in flap function; the Vancouver scar scale score of lower limb skin graft area was 4-7 (5.2±0.9), and the Vancouver scar scale score of thigh skin donor area was 1-5 (3.4±0.8). The patients were fairly satisfied with the curative effects. Conclusions: In repairing the large skin and soft tissue defect from degloving injury in lower extremity, to cover the exposed bone/tendon or functional area with latissimus dorsi myocutaneous flap and the residual wound with artificial dermis and extended split-thickness skin graft is accompanied by harvest of small autologous flap and skin graft, good recovery effect of functional area after surgery, and good quality of healing in skin grafted area.
Cicatrix/surgery*
;
Degloving Injuries/surgery*
;
Dermis/surgery*
;
Female
;
Humans
;
Lower Extremity/surgery*
;
Male
;
Mammaplasty
;
Myocutaneous Flap
;
Reconstructive Surgical Procedures
;
Skin Transplantation
;
Soft Tissue Injuries/surgery*
;
Superficial Back Muscles/surgery*
;
Treatment Outcome
3.Effects of Blast Wave-induced Biomechanical Changes on Lung Injury in Rats.
Wei LIU ; Jia Ke CHAI ; Bin QIN ; Shao Fang HAN ; Xiao Teng WANG ; Shuai JIANG ; Hai Liang BAI ; Ling Ying LIU ; Yang CHANG ; Xiao Tong YUE ; Yu Shou WU ; Zi Hao ZHANG ; Lang TANG
Biomedical and Environmental Sciences 2020;33(5):338-349
Objective:
To observe the dynamic impacts of shock waves on the severity of lung injury in rats with different injury distances.
Methods:
Simulate open-field shock waves; detect the biomechanical effects of explosion sources at distances of 40, 44, and 48 cm from rats; and examine the changes in the gross anatomy of the lungs, lung wet/dry weight ratio, hemoglobin concentration, blood gas analysis, and pathology.
Results:
Biomechanical parameters such as the overpressure peak and impulse were gradually attenuated with an increase in the injury distance. The lung tissue hemorrhage, edema, oxygenation index, and pathology changed more significantly for the 40 cm group than for the 44 and 48 cm groups. The overpressure peak and impulse were significantly higher for the 40 cm group than for the 44 and 48 cm groups ( < 0.05 or < 0.01). The animal mortality was significantly higher for the 40 cm group than for the other two groups (41.2% . 17.8% and 10.0%, < 0.05). The healing time of injured lung tissues for the 40 cm group was longer than those for the 44 and 48 cm groups.
Conclusions
The effects of simulated open-field shock waves on the severity of lung injuries in rats were correlated with the injury distances, the peak overpressure, and the overpressure impulse.
Animals
;
Biomechanical Phenomena
;
Blast Injuries
;
etiology
;
pathology
;
Disease Models, Animal
;
Explosions
;
Lung Injury
;
etiology
;
pathology
;
Male
;
Random Allocation
;
Rats
;
Rats, Sprague-Dawley

Result Analysis
Print
Save
E-mail