1.Clinical Outcomes and Use of Implantable Cardioverter-Defibrillator in Ischemic Heart Failure Patients with Reduced Ejection Fraction:A Retrospective Observational Study
Kyung Hoon CHO ; Ki Hong LEE ; Yong-Kyu LEE ; Seok OH ; Yongwhan LIM ; Joon Ho AHN ; Seung Hun LEE ; Dae Young HYUN ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jang Hoon LEE ; Joo-Yong HAHN ; Yu-Ri KIM ; Nam Sik YOON ; Hyung Wook PARK ; Weon KIM ; Myung Ho JEONG ;
Chonnam Medical Journal 2026;62(2):55-63
Limited data exist regarding the real-world practices and clinical outcomes in patients with ischemic heart failure with reduced left ventricular ejection fractions (LVEFs).Using nationwide registry data from South Korea, we aimed to investigate long-term outcomes and clinical practices, especially implantable cardioverter defibrillators (ICDs) implantation, in patients with reduced LVEFs at least 40 days after acute myocardial infarction (AMI). Of 13,056 patients with AMI between 2011 and 2015, we analyzed 350 (median age, 66 years [interquartile range, 56-75]) who had LVEFs <40% on follow-up transthoracic echocardiogram 40 days after the index event. The primary outcome was cardiac-cause mortality at 3 years. Secondary outcomes comprised major cardiovascular events as well as outcomes defined by the use of ICDs, cardiac resynchronization therapy defibrillators (CRT-Ds), and electrophysiology studies. Among 350 patients, 39 (11.1%) died from cardiac causes during 3 years of follow-up. Eleven (3.1%) were hospitalized for ventricular tachycardia. The rate of ICD or CRT-D implantation up to 3 years was 5.7% (20/350). Cox time-to-event analysis revealed older age, LVEF <30%, diabetes mellitus, and previous MI or revascularization as positively associated with cardiac death, whereas the use of statins and body weight <67 kg were negatively associated. This nationwide Korean registry demonstrated that only 5.7% of patients who had reduced LVEFs after 40 days of AMI underwent ICD implantations over 3 years. Considering the high mortality, concerted efforts are needed to improve clinical outcomes for patients who may have been candidates for ICD implantation.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Real‑world experience of emicizumab prophylaxis in Korean children with severe hemophilia A without inhibitors
Sung Eun KIM ; Ji Yoon KIM ; Jeong A PARK ; Chuhl Joo LYU ; Seung Min HAHN ; Jung Woo HAN ; Young Shil PARK
Blood Research 2024;59():34-
Purpose:
Hemophilia A is a genetic disorder characterized by a lack of factor VIII (FVIII). Emicizumab, a recombinant humanized bispecific monoclonal antibody, mimics the function of FVIII. In this article, we present data on an initial real-world evaluation of emicizumab use in Korean children with severe hemophilia A without inhibitors.
Methods:
This study was conducted from June 2020 to March 2024 at 4 centers in Korea. The participants were pediatric patients with severe hemophilia A without inhibitors who had received emicizumab treatment for over 6 months. The mean and median annualized bleeding rates (ABRs) and mean and median annual joint bleeding rates (AJBRs) were compared.
Results:
Each of the 21 patients in the study received an emicizumab loading regimen of 3 mg/kg weekly for 4 weeks, followed by a modified maintenance regimen of which 2 patients (9.5%) received a 1.5 mg/kg weekly dose, 3 patients (14.3%) received a 6 mg/kg dose every 4 weeks, and the remaining 16 patients (76.2%) received a 3 mg/kg dose every 2 weeks. Before emicizumab prophylaxis initiation, the mean and median ABRs for all patients were 7.04 (SD ± 5.83) and 6.52 (range 0–21.74), respectively. After receiving emicizumab treatment, the mean and mediam ABRs decreased to 0.41 and zero, respectively. Additionally, 85.7% of the patients achieved no bleeding events within 6 months of starting the treatment.
Conclusion
These first real-world data in Korea indicate that emicizumab is effective and safe for pediatric patients with severe hemophilia A without inhibitors.
7.The First Korean Hemoglobinopathy With Unique Hemoglobin Electrophoresis Results Diagnosed as Hemoglobin Boras
Jeongyun BAE ; Won Kee AHN ; Jaehyeok JANG ; Hanmil JANG ; Hyein KANG ; John Hoon RIM ; Seung Min HAHN ; Jung Woo HAN ; Chuhl Joo LYU ; Jong-Baeck LIM
Annals of Laboratory Medicine 2024;44(1):97-99
8.Real‑world experience of emicizumab prophylaxis in Korean children with severe hemophilia A without inhibitors
Sung Eun KIM ; Ji Yoon KIM ; Jeong A PARK ; Chuhl Joo LYU ; Seung Min HAHN ; Jung Woo HAN ; Young Shil PARK
Blood Research 2024;59():34-
Purpose:
Hemophilia A is a genetic disorder characterized by a lack of factor VIII (FVIII). Emicizumab, a recombinant humanized bispecific monoclonal antibody, mimics the function of FVIII. In this article, we present data on an initial real-world evaluation of emicizumab use in Korean children with severe hemophilia A without inhibitors.
Methods:
This study was conducted from June 2020 to March 2024 at 4 centers in Korea. The participants were pediatric patients with severe hemophilia A without inhibitors who had received emicizumab treatment for over 6 months. The mean and median annualized bleeding rates (ABRs) and mean and median annual joint bleeding rates (AJBRs) were compared.
Results:
Each of the 21 patients in the study received an emicizumab loading regimen of 3 mg/kg weekly for 4 weeks, followed by a modified maintenance regimen of which 2 patients (9.5%) received a 1.5 mg/kg weekly dose, 3 patients (14.3%) received a 6 mg/kg dose every 4 weeks, and the remaining 16 patients (76.2%) received a 3 mg/kg dose every 2 weeks. Before emicizumab prophylaxis initiation, the mean and median ABRs for all patients were 7.04 (SD ± 5.83) and 6.52 (range 0–21.74), respectively. After receiving emicizumab treatment, the mean and mediam ABRs decreased to 0.41 and zero, respectively. Additionally, 85.7% of the patients achieved no bleeding events within 6 months of starting the treatment.
Conclusion
These first real-world data in Korea indicate that emicizumab is effective and safe for pediatric patients with severe hemophilia A without inhibitors.
9.Current evidence for prognostic benefit of intravascular imaging-guided percutaneous coronary intervention in chronic total occlusion intervention
David HONG ; Sung Eun KIM ; Seung Hun LEE ; Seung-Jae LEE ; Jong-Young LEE ; Sang Min KIM ; Sang Yeub LEE ; Woochan KWON ; Ki Hong CHOI ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON ; Joo-Yong HAHN ; Joo Myung LEE ;
The Korean Journal of Internal Medicine 2024;39(5):702-716
Although percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) has been increasing in recent years, CTO PCI is still one of the most challenging procedures with relatively higher rates of procedural complications and adverse clinical events after PCI. Due to the innate limitations of invasive coronary angiography, intravascular imaging (IVI) has been used as an adjunctive tool to complement PCI, especially in complex coronary artery disease. Considering the complexity of CTO lesions, the role of IVI is particularly important in CTO intervention. IVI has been a useful adjunctive tool in every step of CTO PCI including assisted wire crossing, confirmation of wire location within CTO segment, and stent optimization. The meticulous use of IVI has been one of the greatest contributors to recent progress of CTO PCI. Nevertheless, studies evaluating the role of IVI during CTO PCI are limited. The current review provides a comprehensive overview of the mechanistic advantages of IVI in CTO PCI, summarizes previous studies and trials, and presents future perspective of IVI in CTO PCI.
10.Real‑world experience of emicizumab prophylaxis in Korean children with severe hemophilia A without inhibitors
Sung Eun KIM ; Ji Yoon KIM ; Jeong A PARK ; Chuhl Joo LYU ; Seung Min HAHN ; Jung Woo HAN ; Young Shil PARK
Blood Research 2024;59():34-
Purpose:
Hemophilia A is a genetic disorder characterized by a lack of factor VIII (FVIII). Emicizumab, a recombinant humanized bispecific monoclonal antibody, mimics the function of FVIII. In this article, we present data on an initial real-world evaluation of emicizumab use in Korean children with severe hemophilia A without inhibitors.
Methods:
This study was conducted from June 2020 to March 2024 at 4 centers in Korea. The participants were pediatric patients with severe hemophilia A without inhibitors who had received emicizumab treatment for over 6 months. The mean and median annualized bleeding rates (ABRs) and mean and median annual joint bleeding rates (AJBRs) were compared.
Results:
Each of the 21 patients in the study received an emicizumab loading regimen of 3 mg/kg weekly for 4 weeks, followed by a modified maintenance regimen of which 2 patients (9.5%) received a 1.5 mg/kg weekly dose, 3 patients (14.3%) received a 6 mg/kg dose every 4 weeks, and the remaining 16 patients (76.2%) received a 3 mg/kg dose every 2 weeks. Before emicizumab prophylaxis initiation, the mean and median ABRs for all patients were 7.04 (SD ± 5.83) and 6.52 (range 0–21.74), respectively. After receiving emicizumab treatment, the mean and mediam ABRs decreased to 0.41 and zero, respectively. Additionally, 85.7% of the patients achieved no bleeding events within 6 months of starting the treatment.
Conclusion
These first real-world data in Korea indicate that emicizumab is effective and safe for pediatric patients with severe hemophilia A without inhibitors.

Result Analysis
Print
Save
E-mail