1.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
2.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
4.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
5.Characteristics and outcomes of portal vein thrombosis in patients with inflammatory bowel disease in Korea
Ki Jin KIM ; Su-Bin SONG ; Jung-Bin PARK ; June Hwa BAE ; Ji Eun BAEK ; Ga Hee KIM ; Min-Jun KIM ; Seung Wook HONG ; Sung Wook HWANG ; Dong-Hoon YANG ; Byong Duk YE ; Jeong-Sik BYEON ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Chang Sik YU ; Yong-Sik YOON ; Jong-Lyul LEE ; Min Hyun KIM ; Ho-Su LEE ; Sang Hyoung PARK
The Korean Journal of Internal Medicine 2025;40(2):243-250
Background/Aims:
Portal vein thrombosis (PVT) frequently occurs in patients with inflammatory bowel disease (IBD), particularly when influenced by factors such as abdominal infections, IBD flare-ups, or surgical procedures. The implications of PVT range from immediate issues such as intestinal ischemia to long-term concerns including portal hypertension and its complications. However, there is a notable gap in comprehensive studies on PVT in IBD, especially with the increasing incidence of IBD in Asia. This research aimed to evaluate the clinical features and outcomes of PVT in patients with IBD at a leading hospital in South Korea.
Methods:
This retrospective analysis reviewed adult patients diagnosed with both IBD and PVT from 1989 to 2021 at a renowned South Korean medical center. The study focused on patient characteristics, specifics of PVT, administered treatments, and outcomes, all confirmed through enhanced CT scans.
Results:
A total of 78 patients met the study’s criteria. Notably, only 20.5% (16/78) were treated with oral anticoagulants; however, a vast majority (96.2%; 75/78) achieved complete radiographic resolution (CRR). When comparing patients receiving anticoagulants to those who did not, a significant preference for anticoagulant use was observed in cases where the main portal vein was affected, as opposed to just the left or right veins (p = 0.006). However, multivariable analysis indicated that neither anticoagulant use nor previous surgeries significantly impacted CRR.
Conclusions
Patients with IBD and PVT generally had favorable outcomes, regardless of anticoagulant use.
6.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
7.Biennial Mammography Performance in the Korean National Cancer Screening Program From 2009 to 2020
Dong Jun KIM ; Nan-He YOON ; Jae Kwan JUN ; Mina SUH ; Sunhwa LEE ; Seongju KIM ; Horim A. HWANG ; Seung Eun JUNG ; Hooyeon LEE
Korean Journal of Radiology 2025;26(4):313-323
Objective:
Mammography is essential for reducing breast cancer mortality; however, its performance varies globally. This study aimed to evaluate mammography screening outcomes in Korea over 12 years and investigate regional variations.
Materials and Methods:
We analyzed mammography data from 42 million Korean women, aged 40 years and older, who participated in the Korean National Cancer Screening Program (KNCSP) from 2009 to 2020. Performance metrics—including recall rate (RR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), cancer detection rate (CDR), interval cancer rate (ICR), and dense breast rate (DBR), were computed. Twelve-year trends in these metrics were analyzed using Joinpoint regression. Regional variations were also examined across Korea’s 237 districts, stratified by age groups.
Results:
From 2009 to 2020, 42165405 mammography screenings were conducted through the KNCSP, increasing from 2821132 screenings in 2009 to 3596204 in 2020. The RR decreased from 17.2% in 2009 to 11.2% in 2020 (average annual percent change [AAPC] = -3.7%), while the PPV increased from 0.8% to 2.8%; AAPC = 10.7%), the CDR increased from 1.5 to 3.1 per 1000; AAPC = 7.3%), and the ICR rose from 0.9 to 1.6 per 1000; (AAPC = 5.2%). Regional variations were noted; however, differences in the RR, sensitivity, specificity, and FPR decreased over time.
Conclusion
While mammography performance improved from 2009 to 2020, the PPV and sensitivity remain suboptimal, underscoring the need for continuous monitoring. Regional disparities in performance, although reduced, persist. These findings provide essential baseline data for improving mammography quality and addressing inequities in breast cancer screening.
9.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
10.Characteristics and outcomes of portal vein thrombosis in patients with inflammatory bowel disease in Korea
Ki Jin KIM ; Su-Bin SONG ; Jung-Bin PARK ; June Hwa BAE ; Ji Eun BAEK ; Ga Hee KIM ; Min-Jun KIM ; Seung Wook HONG ; Sung Wook HWANG ; Dong-Hoon YANG ; Byong Duk YE ; Jeong-Sik BYEON ; Seung-Jae MYUNG ; Suk-Kyun YANG ; Chang Sik YU ; Yong-Sik YOON ; Jong-Lyul LEE ; Min Hyun KIM ; Ho-Su LEE ; Sang Hyoung PARK
The Korean Journal of Internal Medicine 2025;40(2):243-250
Background/Aims:
Portal vein thrombosis (PVT) frequently occurs in patients with inflammatory bowel disease (IBD), particularly when influenced by factors such as abdominal infections, IBD flare-ups, or surgical procedures. The implications of PVT range from immediate issues such as intestinal ischemia to long-term concerns including portal hypertension and its complications. However, there is a notable gap in comprehensive studies on PVT in IBD, especially with the increasing incidence of IBD in Asia. This research aimed to evaluate the clinical features and outcomes of PVT in patients with IBD at a leading hospital in South Korea.
Methods:
This retrospective analysis reviewed adult patients diagnosed with both IBD and PVT from 1989 to 2021 at a renowned South Korean medical center. The study focused on patient characteristics, specifics of PVT, administered treatments, and outcomes, all confirmed through enhanced CT scans.
Results:
A total of 78 patients met the study’s criteria. Notably, only 20.5% (16/78) were treated with oral anticoagulants; however, a vast majority (96.2%; 75/78) achieved complete radiographic resolution (CRR). When comparing patients receiving anticoagulants to those who did not, a significant preference for anticoagulant use was observed in cases where the main portal vein was affected, as opposed to just the left or right veins (p = 0.006). However, multivariable analysis indicated that neither anticoagulant use nor previous surgeries significantly impacted CRR.
Conclusions
Patients with IBD and PVT generally had favorable outcomes, regardless of anticoagulant use.

Result Analysis
Print
Save
E-mail