1.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice
Joo Myung LEE ; Hyun Sung JOH ; Ki Hong CHOI ; David HONG ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Jin-Ho CHOI ; Seung-Hyuk CHOI ; Jin-Ok JEONG ; Jong-Young LEE ; Young Jin CHOI ; Jei-Keon CHAE ; Seung-Ho HUR ; Jang-Whan BAE ; Ju-Hyeon OH ; Kook-Jin CHUN ; Hyun-Joong KIM ; Byung Ryul CHO ; Doosup SHIN ; Seung Hun LEE ; Doyeon HWANG ; Hyun-Jong LEE ; Ho-Jun JANG ; Hyun Kuk KIM ; Sang Jin HA ; Eun-Seok SHIN ; Joon-Hyung DOH ; Joo-Yong HAHN ; Hyeon-Cheol GWON ; On behalf of the SMART-REWARD Investigators
Journal of Korean Medical Science 2023;38(5):e34-
Background:
The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance.
Methods:
The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patientoriented composite outcome (POCO) at 2 years.
Results:
Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group.Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel.Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487–3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663–3.012,P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups.
Conclusion
With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES.
10.Synaptic Remodeling of the Auditory Cortex Following Bilateral Blindness: Evidence of Cross-modal Plasticity
Jae Joon HAN ; Tae-Soo NOH ; Myung-Whan SUH ; Seung Ha KIM ; Doo Hee KIM ; Sang Jeong KIM ; Seung Ha OH
Experimental Neurobiology 2022;31(5):299-306
We aimed to evaluate structural dynamic changes of neurons in the auditory cortex after visual deprivation. We longitudinally tracked dendritic spines for 3 weeks after visual deprivation in vivo using a two-photon microscope. GFP-labeled dendritic spines in the auditory cortex were serially followed after bilateral enucleation. The turnover rate, density, and size of the spines in the dendrites were evaluated 1, 2, and 3 weeks after visual deprivation. The turnover rate of the dendritic spines in the auditory cortex increased at 1 week (20.1±7.3%) after bilateral enucleation compared to baseline (12.5±7.9%); the increase persisted for up to 3 weeks (20.9±11.0%). The spine loss rate was slightly higher than the spine gain rate. The average spine density (number of spines per 1 μm of dendrite) was significantly lower at 2 weeks (2W; 0.22±0.06 1/μm) and 3 W (0.22±0.08 1/μm) post-nucleation compared to baseline (0.026±0.09 1/μm). We evaluated the change of synaptic strength in the stable spines at each time point. The normalized spine size in the auditory cortex was significantly increased after bilateral blindness at 1 W postoperatively (1.36±0.92), 2 W postoperatively (1.40±1.18), and 3 W postoperatively (1.36±0.88) compared to baseline. Sensory deprivation resulted in remodeling of the neural circuitry in the spared cortex, via cross-modal plasticity in the direction of partial breakdown of synapses, and enhanced strength of the remaining synapses.

Result Analysis
Print
Save
E-mail