1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.The First Korean Hemoglobinopathy With Unique Hemoglobin Electrophoresis Results Diagnosed as Hemoglobin Boras
Jeongyun BAE ; Won Kee AHN ; Jaehyeok JANG ; Hanmil JANG ; Hyein KANG ; John Hoon RIM ; Seung Min HAHN ; Jung Woo HAN ; Chuhl Joo LYU ; Jong-Baeck LIM
Annals of Laboratory Medicine 2024;44(1):97-99
5.The Correlation between MMP-9 Point-of-Care Assay and Clinical Symptoms and Signs of Dry Eye Disease
Su yeon HAN ; Ha rim SO ; Seung hoon LEE ; Ji won BAEK ; Ho RA ; Nam yeo KANG ; Eun chul KIM
Annals of Optometry and Contact Lens 2024;23(2):58-63
Purpose:
To evaluate the correlation between matrix metalloproteinase-9 (MMP-9) point-of-assay and clinical symptoms and signs of dry eye disease.
Methods:
We performed a retrospective study for patients diagnosed with dry eye. MMP-9 (InflammaDry) was performed on 235 patients. Patients were assessed using Schirmer test, corneal staining score, tear film breakup time (TBUT) and the Ocular Surface Disease Index (OSDI).
Results:
The score of Schirmer test was lower significantly in MMP-9 positive group than in MMP-9 negative group (for each 4.21 ± 5.80 mm, 5.96 ± 8.14 mm; p = 0.035). TBUT was shorter significantly in MMP-9 positive group than in MMP-9 negative group (for each 5.46 ± 4.06 s, 8.27 ± 4.75 s; p = 0.0008). The ratio of positive corneal stain (for each 83%, 31%) and OSDI even or greater than 13 (for each 80%, 75%) was significantly higher in MMP-9 positive group than in MMP-9 negative group (p = 0.00001, p = 0.0044). The value of MMP-9 point-of-care assay showed showed the negative correlation with Schirmer test (Rs = 0.383, p < 0.001), and TBUT (Rs = 0.310, p < 0.05), and showed the positive correlation with corneal staining score (Rs = 0.527, p < 0.001), OSDI (Rs = 0.510, p < 0.001).
Conclusions
MMP-9 point-of-assay accords with clinical symptoms and signs of Dry eye disease, and may be helpful in diagnosing Dry eye disease.
6.Efficacy and Safety of Lurasidone vs. Quetiapine XR in Acutely Psychotic Patients With Schizophrenia in Korea: A Randomized, Double-Blind, Active-Controlled Trial
Se Hyun KIM ; Do-Un JUNG ; Do Hoon KIM ; Jung Sik LEE ; Kyoung-Uk LEE ; Seunghee WON ; Bong Ju LEE ; Sung-Gon KIM ; Sungwon ROH ; Jong-Ik PARK ; Minah KIM ; Sung Won JUNG ; Hong Seok OH ; Han-yong JUNG ; Sang Hoon KIM ; Hyun Seung CHEE ; Jong-Woo PAIK ; Kyu Young LEE ; Soo In KIM ; Seung-Hwan LEE ; Eun-Jin CHEON ; Hye-Geum KIM ; Heon-Jeong LEE ; In Won CHUNG ; Joonho CHOI ; Min-Hyuk KIM ; Seong-Jin CHO ; HyunChul YOUN ; Jhin-Goo CHANG ; Hoo Rim SONG ; Euitae KIM ; Won-Hyoung KIM ; Chul Eung KIM ; Doo-Heum PARK ; Byung-Ook LEE ; Jungsun LEE ; Seung-Yup LEE ; Nuree KANG ; Hee Yeon JUNG
Psychiatry Investigation 2024;21(7):762-771
Objective:
This study was performed to evaluate the efficacy and safety of lurasidone (160 mg/day) compared to quetiapine XR (QXR; 600 mg/day) in the treatment of acutely psychotic patients with schizophrenia.
Methods:
Patients were randomly assigned to 6 weeks of double-blind treatment with lurasidone 160 mg/day (n=105) or QXR 600 mg/day (n=105). Primary efficacy measure was the change from baseline to week 6 in Positive and Negative Syndrome Scale (PANSS) total score and Clinical Global Impressions severity (CGI-S) score. Adverse events, body measurements, and laboratory parameters were assessed.
Results:
Lurasidone demonstrated non-inferiority to QXR on the PANSS total score. Adjusted mean±standard error change at week 6 on the PANSS total score was -26.42±2.02 and -27.33±2.01 in the lurasidone and QXR group, respectively. The mean difference score was -0.91 (95% confidence interval -6.35–4.53). The lurasidone group showed a greater reduction in PANSS total and negative subscale on week 1 and a greater reduction in end-point CGI-S score compared to the QXR group. Body weight, body mass index, and waist circumference in the lurasidone group were reduced, with significantly lower mean change compared to QXR. Endpoint changes in glucose, cholesterol, triglycerides, and low-density lipoprotein levels were also significantly lower. The most common adverse drug reactions with lurasidone were akathisia and nausea.
Conclusion
Lurasidone 160 mg/day was found to be non-inferior to QXR 600 mg/day in the treatment of schizophrenia with comparable efficacy and tolerability. Adverse effects of lurasidone were generally tolerable, and beneficial effects on metabolic parameters can be expected.
7.Successful Simultaneous Treatment of Benign Stricture and Colonic Neoplasm Arising from Colonic Interposition after Esophagectomy: A Case Report
Seung Hee KIM ; Jin Won KIM ; Seon-Young PARK ; Hyun-Soo KIM ; Chae June LIM ; Gang Han LEE ; Jae Woong LIM ; Young Eun SEO ; Shin Young PARK ; Yo Han LEE ; Yong-Wook JUNG ; Woo Rim KANG ; Hye-Su YOU ; Dong Hyun KIM
The Korean Journal of Gastroenterology 2023;82(3):140-144
Colonic interposition is the main procedure used in esophageal reconstruction. We report a rare case of simultaneous treatment of an anastomotic site stricture and a neoplasm in the interpositioned colon. A 69-year-old female visited our outpatient clinic with symptoms of progressive dysphagia for 1 year. At the age of 30 years, the patient underwent esophagectomy with retrosternal colonic interposition because of severe esophageal burns after chemical ingestion. Upper gastrointestinal endoscopy revealed stricture at the anastomosis site and a 10-mm flat elevated high-grade dysplasia in the interpositioned colon. First, through-the-scope balloon dilatation was performed for strictures. However, stenosis was observed during the second upper gastrointestinal endoscopy session.Therefore, a second session of through-the-scope balloon dilatation was performed, and simultaneously, endoscopic submucosal dissection was also successfully performed. After 2 months of follow-up, stenosis persisted; consequently, balloon dilatation was performed. No recurrence of neoplasm was confirmed endoscopically. Through-the-scope balloon dilatation of the stricture site and simultaneous endoscopic submucosal dissection of the neoplasm in the interpositioned colon were successfully performed.
8.Comparison between Pediatric Crohn’s Disease and Ulcerative Colitis at Diagnosis in Korea: Results from a Multicenter, Registry-Based, Inception Cohort Study
Sowon PARK ; Ben KANG ; Seung KIM ; Sujin CHOI ; Hyo Rim SUH ; Eun Sil KIM ; Ji Hyung PARK ; Mi Jin KIM ; Yon Ho CHOE ; Yeoun Joo LEE ; Jae Hong PARK ; Eell RYOO ; Hong KOH ; Byung-Ho CHOE
Gut and Liver 2022;16(6):921-929
Background/Aims:
We aimed to compare the differences in pediatric Crohn’s disease (CD) and ulcerative colitis (UC) at diagnosis in Korea.
Methods:
This was a multicenter, registry-based, inception cohort study conducted at five centers in Korea between 2013 and 2017. Baseline demographics, clinical characteristics, and results from laboratory, endoscopic, radiologic examinations were compared between pediatric CD and UC patients who were <19 years old at diagnosis.
Results:
A total 307 patients were included (227 CD [73.9%] and 80 UC [26.1%]). The male to female ratio was 2.49:1 for CD, and 1.49:1 for UC (p=0.019). Median age at diagnosis was 14.4 years (interquartile range, 12.4 to 16.2) for CD, and 14.4 years (interquartile range, 11.7 to 16.5) for UC (p=0.962). Hematochezia was the only dominant symptom in UC patients compared to CD patients (86.2% vs 30.8%, p<0.001). White blood cell counts, platelet counts, erythrocyte sedimentation rate, and C-reactive protein levels were significantly higher, and serum albumin level was significantly lower in CD patients than in UC patient. Anti-Saccharomyces cerevisiae antibody was positive in 44.5% and 16.2% of CD and UC patients, respectively (p<0.001), and antineutrophil cytoplasmic antibody was positive in 15.0% and 58.8% of CD and UC patients, respectively (p<0.001). Terminal ileal involvement was prominent in CD, while rectal involvement was more prominent in UC. Small bowel involvement and perianal perforating diseases were also more prominent in CD.
Conclusions
This is the first a multicenter study in Korea to compare the differences between pediatric CD and UC at diagnosis in Korea. A large-scale, national study is expected to better clarify these findings in the future.
9.Chondrolipoma of the Shoulder: A Case Report
Soonchunhyang Medical Science 2022;28(1):53-57
Chondrolipoma is rare and is mainly encountered in large-sized, long-standing lipomas. Chondrolipoma can be found at almost any site of the body, particularly in the connecting tissue of the skeletal system, breast, pharynx, and nasopharynx. A small number of chondrolipomas have been reported in the literature with rare magnetic resonance examples available. Here, we report a rare case of chondrolipoma in the shoulder and review its radiographic and pathologic correlation. This paper aims to report plain radiograph, computed tomography, and magnetic resonance examples of chondrolipoma
10.Understanding Physicians’ and Nurses’ Adaption of National-Leading Patient Safety Culture Policy: A Qualitative Study in Tertiary and General Hospitals in Korea
Won LEE ; MoonHee CHOI ; Eunjung PARK ; Eunji PARK ; Shinhee KANG ; Jessie LEE ; Seung Gyeong JANG ; Hae-Rim HAN ; Sang-il LEE ; Ji Eun CHOI
Journal of Korean Medical Science 2022;37(14):e114-
Background:
In Korea, the safety culture is led by national policy. How the policy ensures a patient safety culture needs to be investigated. This study aimed to examine the way in which physicians and nurses regard, understand, or interpret the patient safety-related policy in the hospital setting.
Methods:
In this qualitative study, we conducted four focus group interviews (FGIs) with 25 physicians and nurses from tertiary and general hospitals in South Korea. FGIs data were analyzed using thematic analysis, which was conducted in an inductive and interpretative way.
Results:
Three themes were identified. The healthcare providers recognized its benefits in the forms of knowledge, information and training at least although the policy implemented by the law forcibly and temporarily. The second theme was about the interaction of the policy and the Korean context of healthcare, which makes a “turning point” in the safety culture.The final theme was about some strains and conflicts resulting from patient safety policy.
Conclusion
To provide a patient safety culture, it is necessary to develop a plan to improve the voluntary participation of healthcare professionals and their commitment to safety.Hospitals should provide more resources and support for healthcare professionals.

Result Analysis
Print
Save
E-mail