1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Quality Indicators of Endoscopic Retrograde Cholangiopancreatography in Korea
Ki-Hyun KIM ; Hyung Ku CHON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Jin-Seok PARK ; Seung Bae YOON ; Kwang Hyung CHUNG ; Jin JIN ; Miyoung CHOI
Korean Journal of Pancreas and Biliary Tract 2024;29(4):144-156
Endoscopic retrograde cholangiopancreatography (ERCP) is a procedure that requires abundant clinical experience and endoscopic skills, and can lead to various complications, some of which may progress to life-threatening conditions. With expanding indications and technological advancements, ERCP is widely utilized, enhancing procedural accessibility. However, without proper quality management, the procedure can pose significant risks. Quality management in ERCP is essential to ensure safe and successful procedures and meet societal demands for improved healthcare competitiveness. To address these concerns, the Korean Pancreatobiliary Association has developed a Korean-specific ERCP quality indicator reflecting domestic medical environments and realities. Initially, based on a review of foreign ERCP quality indicators and related literatures, key questions were formulated for five preprocedural items, three intra-procedural items, and four post-procedural items. Descriptions and recommendations for each item were selected through peer evaluation. The developed Korean-specific ERCP quality indicator was reviewed by external experts based on the latest evidence and consensus in this fields. This Korean-specific indicator is expected to significantly contribute to improving ERCP quality in Korea, as it is tailored to local needs.
9.Preliminary data on computed tomography-based radiomics for predicting programmed death ligand 1 expression in urothelial carcinoma
Chang Mu LEE ; Seung Baek HONG ; Nam Kyung LEE ; Hong Koo HA ; Kyung Hwan KIM ; Byeong Jin KANG ; Suk KIM ; Ja Yoon KU
Kosin Medical Journal 2024;39(3):186-194
Background:
Programmed death ligand 1 (PD-L1) expression cannot currently be predicted through radiological findings. This study aimed to develop a prediction model capable of differentiating between positive and negative PD-L1 expression through a radiomics-based investigation of computed tomography (CT) images in patients with urothelial carcinoma.
Methods:
Sixty-four patients with urothelial carcinoma who underwent immunohistochemical testing for PD-L1 were retrospectively reviewed. The number of patients in the positive and negative PD-L1 groups (PD-L1 expression >5%) was 14 and 50, respectively. CT images obtained 90 seconds after contrast medium administration were selected for radiomic extraction. For all tumors, 1,691 radiomic features were extracted from CT using a manually segmented three-dimensional volume of interest. Univariate and multivariate logistic regression analyses were performed to identify radiomic features that were significant predictors of PD-L1 expression. For the radiomics-based model, a receiver operating characteristic (ROC) analysis was performed.
Results:
Among 64 patients, 14 were included in the PD-L1 positive group. Logistic regression analysis found that the following radiomic features significantly predicted PD-L1 expression: wavelet-low-pass, low-pass, and high-pass filters (LLH)_gray-level size-zone matrix (GLSZM)_SmallAreaEmphasis, wavelet-LLH_firstorder_Energy, log-sigma-0-5-mm-3D_GLSZM_SmallAreaHighGrayLevelEmphasis, original_shape_Maximum2DDiameterColumn, wavelet-low-pass, low-pass, and low-pass filters (LLL)_gray-level run-length matrix (GLRLM)_ShortRunEmphasis, and exponential_firstorder_Kurtosis. The radiomics signature was –4.0934+21.6224 (wavelet-LLH_GLSZM_SmallAreaEmphasis)+0.0044 (wavelet-LLH_firstorder_Energy)–4.7389 (log-sigma-0-5-mm-3D_GLSZM_SmallAreaHighGrayLevelEmphasis)+0.0573 (original_shape_Maximum2DDiameterColumn)–29.5892 (wavelet-LLL_GLRLM_ShortRunEmphasis)–0.4324 (exponential_firstorder_Kurtosis). The area under the ROC curve model representing the radiomics signature for differentiating cases that were deemed PD-L1 positive based on immunohistochemistry was 0.96.
Conclusions
This preliminary radiomics model derived from contrast-enhanced CT predicted PD-L1 positivity in patients with urothelial cancer.
10.Assessment of immunopathological responses of a novel non‑chemical biocide in C57BL/6 for safe disinfection usage
Keun Bon KU ; Jihwan CHAE ; Won Hyung PARK ; Jeongwoo LA ; Seung S. LEE ; Heung Kyu LEE
Laboratory Animal Research 2024;40(3):318-332
Background:
Water electrospray technology has been developed and extensively studied for its physical properties and potential application as a non-chemical biocide against airborne pathogens. However, there are still concerns regarding the safety and potential toxicity of inhaling water electrospray (WE) particles. To address these potential hazards and offer insights into the impact of WE on humans, we analyzed the immunopathological response to WE by employing an intranasal challenge C57BL/6 mouse model. This analysis aimed to compare the effects of WE with those of sodium hypochlorite (SH), a well-known biocidal agent.
Results:
The study findings suggest that the WE did not trigger any pathological immune reactions in the intranasal-challenged C57BL/6 mouse model. Mice challenged with WE did not experience body weight loss, and there was no increase in inflammatory cytokine production compared to SH-treated mice. Histopathological analysis revealed that WE did not cause any damage to the lung tissue. In contrast, mice treated with SH exhibited significant lung tissue damage, characterized by the infiltration of neutrophils and eosinophils. Transcriptomic analysis of lung tissue further confirmed the absence of a pathological immune response in mice treated with WE compared to those treated with SH. Upon intranasal challenge with WE, the C57BL/6 mouse model did not show any evidence of immunopathological damage.
Conclusions
The results of this study suggest that WE is a safe technology for disinfecting airborne pathogens. It demonstrated little to no effect on immune system activation and pathological outcomes in the intranasal challenge C57BL/6 mouse model. These findings not only support the potential use of WE as an effective and safe method for air disinfection but also highlight the value of the intranasal challenge of the C57BL/6 mouse model in providing significant immunopathological insights for assessing the inhalation of novel materials for potential use.

Result Analysis
Print
Save
E-mail