1.Evaluation of a Vietnamese medical school using Korean medical school accreditation standards
Bo-Young YOON ; Yon-Chul PARK ; Keunmi LEE ; Hee-Je LEE ; Jung-Sook HA ; Seung-Jae HONG ; Nguyen Hoang MINH ; Jung-Sik HUH
Journal of Medicine and Life Science 2026;23(1):24-32
The global shortage of healthcare personnel, especially in low- and middle-income countries, has raised concerns about the quality and availability of medical education across these economies. Therefore, standardization and accreditation of medical education are essential to ensure the competence of healthcare professionals. This study reports the first-ever application of the set of standards developed by the Korean Institute of Medical Education and Evaluation (KIMEE) to assess a Vietnamese medical school. Under this initiative, the Accreditation Standards of KIMEE 2019 (ASK 2019) was implemented under the auspices of a Korea International Cooperation Agency Development Project. This study compared the evaluation results of a Vietnamese medical school’s performance with that of accredited Korean medical schools. The findings revealed both strengths and areas requiring significant improvement and underscore the need for Vietnam to develop its own contextually appropriate accreditation system.
2.Primary Cutaneous CD30+ Lymphoproliferative Disorders in South Korea: A Nationwide, Multi-Center, Retrospective, Clinical, and Prognostic Study
Woo Jin LEE ; Sook Jung YUN ; Joon Min JUNG ; Joo Yeon KO ; Kwang Ho KIM ; Dong Hyun KIM ; Myung Hwa KIM ; You Chan KIM ; Jung Eun KIM ; Chan-Ho NA ; Je-Ho MUN ; Jong Bin PARK ; Ji-Hye PARK ; Hai-Jin PARK ; Dong Hoon SHIN ; Jeonghyun SHIN ; Sang Ho OH ; Seok-Kweon YUN ; Dongyoun LEE ; Seok-Jong LEE ; Seung Ho LEE ; Young Bok LEE ; Soyun CHO ; Sooyeon CHOI ; Jae Eun CHOI ; Mi Woo LEE ; On behalf of The Korean Society of Dermatopathology
Annals of Dermatology 2025;37(2):75-85
Background:
Primary cutaneous CD30+ lymphoproliferative disorders (pcCD30-LPDs) are a diseases with various clinical and prognostic characteristics.
Objective:
Increasing our knowledge of the clinical characteristics of pcCD30-LPDs and identifying potential prognostic variables in an Asian population.
Methods:
Clinicopathological features and survival data of pcCD30-LPD cases obtained from 22 hospitals in South Korea were examined.
Results:
A total of 413 cases of pcCD30-LPDs (lymphomatoid papulosis [LYP], n=237; primary cutaneous anaplastic large cell lymphoma [C-ALCL], n=176) were included. Ninety percent of LYP patients and roughly 50% of C-ALCL patients presented with multiple skin lesions. Both LYP and C-ALCL affected the lower limbs most frequently. Multiplicity and advanced T stage of LYP lesions were associated with a chronic course longer than 6 months. Clinical morphology with patch lesions and elevated serum lactate dehydrogenase were significantly associated with LPDs during follow-up in LYP patients. Extracutaneous involvement of C-ALCL occurred in 13.2% of patients. Lesions larger than 5 cm and increased serum lactate dehydrogenase were associated with a poor prognosis in C-ALCL. The survival of patients with C-ALCL was unaffected by the anatomical locations of skin lesions or other pathological factors.
Conclusion
The multiplicity or size of skin lesions was associated with a chronic course of LYP and survival among patients with C-ALCL.
3.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
7.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.Non-resectable bilateral malignant granulosa cell tumor with metastasis in a dog: a case report
Young-Tak CHO ; Chang-Hyeon CHOI ; Keon KIM ; Chang-Yun JE ; Jae-Beom JOO ; Seung-Ju KANG ; Sang-Ik PARK ; Woong-Bin RO ; Chang-Min LEE
Korean Journal of Veterinary Research 2025;65(1):e7-
A seventeen-year-old Shih Tzu presented with severe abdominal distension and labored respiration. Radiographic examination revealed severe ascites and pleural effusion. Bilateral malignant ovarian tumor, which was non-resectable due to distant metastasis, was diagnosed through computed tomography and cytology. Chemotherapy with carboplatin significantly delayed fluid accumulation, improving quality of life for 6 months. Necropsy later confirmed metastatic malignant bilateral granulosa cell tumor involving lymph nodes, liver, and thoracic cavity. This case demonstrates the feasibility of chemotherapy and symptomatic management as alternatives to ovariohysterectomy in metastatic ovarian tumors, highlighting its potential to extend survival and maintain quality of life when surgery is contraindicated.

Result Analysis
Print
Save
E-mail