1.Bisphosphonates as a Tacrolimus-Sparing Strategy in Kidney Transplantation: Insights from a Retrospective Analysis
Hee Byung KOH ; Hyo Jeong KIM ; Ga Young HEO ; Namki HONG ; Yaeji LEE ; Seung Hwan SONG ; Hoon Young CHOI ; Chan-Young JUNG ; Hyung Woo KIM ; Jaeseok YANG ; Kyu Ha HUH ; Chung Mo NAM ; Beom Seok KIM
Yonsei Medical Journal 2026;67(1):17-26
Purpose:
Due to chronic toxicity, tacrolimus-sparing is an important issue in kidney transplant recipients (KTRs). Several studies have shown that bisphosphonate use is associated with favorable graft outcomes in KTRs. We investigated whether the association between tacrolimus trough levels (TTLs) and graft outcomes differed according to bisphosphonate use in KTRs.
Materials and Methods:
We conducted a retrospective study encompassing 1441 KTRs who were administered tacrolimus-based immunosuppressants. The primary exposure was a time-dependent cross-product of TTLs (low TTLs vs. normal-high TTLs with a reference of 6 ng/mL) and bisphosphonate use. Two primary outcomes were evaluated: overall graft loss (death or conversion to kidney replacement) and an estimated glomerular filtration rate (eGFR) <30 mL/min/1.73 m 2 .
Results:
During the median follow-up of 6.1 (3.4–9.7) years, overall graft loss occurred in 157 (10.9%) patients. Cox regression revealed that normal-high TTLs without bisphosphonate use were associated with a reduced risk of overall graft loss [adjusted hazard ratio (aHR), 0.65; 95% confidence interval (CI), 0.45–0.95] compared to low TTLs without bisphosphonate use. The use of bisphosphonate in conjunction with normal-high TTLs correlated with an even lower risk of overall graft loss (aHR, 0.25; 95% CI, 0.08–0.80) compared with low TTLs without bisphosphonate use. In patients with low TTLs, bisphosphonate use was associated with a reduced risk of overall graft loss compared with non-use (aHR, 0.20; 95% CI, 0.09–0.43). Similar trends were observed in the eGFR outcome.
Conclusion
The use of bisphosphonate was associated with favorable graft outcomes, even with low TTLs. Incorporating bisphosphonate into a conventional immunosuppressant regimen may potentially reduce tacrolimus requirement.
2.Real-Time Assessment of Black Carbon Peaks Among Workers Exposed to Diesel Engine Exhaust Emissions
Ju-Hyun PARK ; Sangjun CHOI ; Kyung Ehi ZOH ; Seung Won KIM ; Dong-Hee KOH ; Won KIM ; Dong-Uk PARK
Safety and Health at Work 2026;17(1):142-150
Background:
Workers are commonly exposed to diesel engine exhaust (DEE) from diesel-powered engines and vehicles (DEVs), which contain harmful particulates such as black carbon (BC). This study aimed to characterize the peak BC exposures of workers operating or working near DEVs.
Methods:
BC levels were recorded every minute from workers driving or working near DEVs using a portable aethalometer and were categorized by job type and activity. Peak BC levels were characterized using the occupational exposure limits for DEE (measured as elemental carbon) of 10 μg/m 3 and 50 μg/ m3 as cut-off values.
Results:
Forklift operators, garbage collectors, and machine operators showed peak BC exposure levels surpassing 20 μg/m 3 , with average levels above 10 μg/m 3 . Despite their short exposure durations (<1 hour), these peaks contributed significantly (>60%) to the daily average BC exposure. The daily contribution rate of peak exposures above 10 μg/m 3 to the average daily BC exposure often exceeded 50%. The ratio of peak levels above 10 μg/m 3 and 50 μg/m 3 to the arithmetic mean was negatively correlated with exposure duration, the proportion of exposure duration, and the daily contribution of peak levels.
Conclusion
Drivers of diesel-engine vehicles often experienced significant spikes in BC exposure, highlighting the need for real-time monitoring, which is recommended as a best-practice approach to identify and mitigate short-term peak exposures.
3.A Protocol of Korean JOint RegistrY for ALZheimer’s Treatment and Diagnostics (JOY-ALZ)
Geon Ha KIM ; Jung-Min PYUN ; Danbee KANG ; Sung Hoon KANG ; Seong-Ho KOH ; Jae Seung KIM ; So Young MOON ; Won-Jin MOON ; Young Ho PARK ; YongSoo SHIM ; Dong Won YANG ; Young Chul YOUN ; Young Hee JUNG ; Hanna CHO ; Hojin CHOI ; Jae-Sung LIM ; Kee Hyung PARK ; Seong Hye CHOI
Dementia and Neurocognitive Disorders 2026;25(1):25-41
Background:
and Purpose: To assess the long-term effectiveness, safety, and economic viability of recently approved Alzheimer’s disease (AD) therapies, as well as to evaluate the real-world application of novel diagnostics among AD patients with diverse comorbidities, comprehensive real-world data (RWD) analysis is essential. The Korean JOint RegistrY for ALZheimer’s Treatment and Diagnostics (JOY-ALZ) endeavors to create a registry of RWD derived from clinical practice on new diagnostic methods and therapeutic agents for AD introduced in Korea since 2021.
Methods:
Participants must fulfill all the following: 1) be at least 19 years old; 2) be actively receiving, scheduled to initiate, or undergoing evaluation for any AD disease-modifying treatment; 3) have completed amyloid positron emission tomography or cerebrospinal fluid AD immunoassay (a positive result is not essential for participation); 4) have a clinical classification of cognitively unimpaired, mild cognitive impairment, or probable AD dementia. Data generated during routine care is segmented into a minimum dataset, extended dataset, and research-only dataset requiring extra consent. Assessments encompass clinical, cognitive, functional, neurobehavioral, neuroimaging, and biomarker evaluations, in addition to systematic monitoring of new AD treatments and their safety.Data are collected and monitored at baseline, at semiannual intervals during the initial 2 years, and then annually up to 2034. To date, 46 medical centers will participate in JOY-ALZ.
Conclusions
JOY-ALZ is expected to promote understanding of the long-term clinical outcomes, safety, and cost-effectiveness of recently introduced diagnostics and treatments for AD, thereby supporting the progress of precision medicine in AD care and diagnosis.
4.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
9.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
10.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.

Result Analysis
Print
Save
E-mail