1.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
2.Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location
Seul-Gi KIM ; Bongkyung PARK ; Kyosun HWANG ; Woong Kyo JEONG
Clinics in Orthopedic Surgery 2025;17(1):166-173
Background:
Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.
Methods:
Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).
Results:
The 10 individuals’ age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, p = 0.076;ICC = 0.408, p = 0.131; and ICC = 0.296, p = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, p = 0.039 and ICC = 0.702, p = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, p = 0.002 and ICC = 0.565, p = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, p = 0.001; ICC = 0.800, p = 0.001; and ICC = 0.825, p = 0.001, respectively).The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, p = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, p = 0.029 and ICC = 0.682, p = 0.008, respectively).
Conclusions
SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.
3.Clinical and radiologic outcomes of partial trapeziectomy and suture button suspensionplasty for the treatment of thumb carpometacarpal joint arthritis: a study with a minimum 2-year follow-up
Yeongyoon KOH ; Seul Gi PARK ; Jae Jun NAM ; Jong Woong PARK ; In Cheul CHOI
Archives of hand and microsurgery 2025;30(1):22-28
Purpose:
This study investigated the clinical and radiologic outcomes of partial trapeziectomy and suspensionplasty with a suture button for thumb carpometacarpal (CMC) joint osteoarthritis over a 2-year follow-up period.
Methods:
This retrospective study involved 17 patients with thumb CMC joint osteoarthritis (Eaton and Littler stage II or III) treated with partial trapeziectomy and suspensionplasty using a suture button. Clinical outcomes were evaluated using a visual analog scale for pain, the Quick DASH score, pinch and grip strength, and thumb range of motion. The trapezial space ratio (TSR) was used as a radiologic parameter to evaluate radiologic outcomes immediately postoperatively, at 6 months, and at the final follow-up.
Results:
The study included 17 patients (female, 16 and male, 1) with an average age of 63.2 years (range, 56–70 years). Surgery was performed on the dominant hand in nine cases and the nondominant hand in eight. Significant improvements were observed in clinical outcomes. The TSR significantly decreased up to 6 months postoperatively, but there was no significant change from 6 months onward. Complications included button irritation (n=1), a metacarpal fracture (n=1), and flexor carpi radialis tendon rupture (n=1), which were subsequently treated. At the last follow-up, significant improvements in functional outcomes were observed in comparison to the preoperative status.
Conclusion
The procedure demonstrated significantly improved clinical outcomes over a 2-year follow-up. This method is less invasive than other surgical techniques because it preserves part of the trapezium, making it a favorable surgical option in patients with early basal thumb arthritis (below Eaton stage III).
4.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
5.Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location
Seul-Gi KIM ; Bongkyung PARK ; Kyosun HWANG ; Woong Kyo JEONG
Clinics in Orthopedic Surgery 2025;17(1):166-173
Background:
Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.
Methods:
Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).
Results:
The 10 individuals’ age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, p = 0.076;ICC = 0.408, p = 0.131; and ICC = 0.296, p = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, p = 0.039 and ICC = 0.702, p = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, p = 0.002 and ICC = 0.565, p = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, p = 0.001; ICC = 0.800, p = 0.001; and ICC = 0.825, p = 0.001, respectively).The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, p = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, p = 0.029 and ICC = 0.682, p = 0.008, respectively).
Conclusions
SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.
6.Clinical and radiologic outcomes of partial trapeziectomy and suture button suspensionplasty for the treatment of thumb carpometacarpal joint arthritis: a study with a minimum 2-year follow-up
Yeongyoon KOH ; Seul Gi PARK ; Jae Jun NAM ; Jong Woong PARK ; In Cheul CHOI
Archives of hand and microsurgery 2025;30(1):22-28
Purpose:
This study investigated the clinical and radiologic outcomes of partial trapeziectomy and suspensionplasty with a suture button for thumb carpometacarpal (CMC) joint osteoarthritis over a 2-year follow-up period.
Methods:
This retrospective study involved 17 patients with thumb CMC joint osteoarthritis (Eaton and Littler stage II or III) treated with partial trapeziectomy and suspensionplasty using a suture button. Clinical outcomes were evaluated using a visual analog scale for pain, the Quick DASH score, pinch and grip strength, and thumb range of motion. The trapezial space ratio (TSR) was used as a radiologic parameter to evaluate radiologic outcomes immediately postoperatively, at 6 months, and at the final follow-up.
Results:
The study included 17 patients (female, 16 and male, 1) with an average age of 63.2 years (range, 56–70 years). Surgery was performed on the dominant hand in nine cases and the nondominant hand in eight. Significant improvements were observed in clinical outcomes. The TSR significantly decreased up to 6 months postoperatively, but there was no significant change from 6 months onward. Complications included button irritation (n=1), a metacarpal fracture (n=1), and flexor carpi radialis tendon rupture (n=1), which were subsequently treated. At the last follow-up, significant improvements in functional outcomes were observed in comparison to the preoperative status.
Conclusion
The procedure demonstrated significantly improved clinical outcomes over a 2-year follow-up. This method is less invasive than other surgical techniques because it preserves part of the trapezium, making it a favorable surgical option in patients with early basal thumb arthritis (below Eaton stage III).
7.Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location
Seul-Gi KIM ; Bongkyung PARK ; Kyosun HWANG ; Woong Kyo JEONG
Clinics in Orthopedic Surgery 2025;17(1):166-173
Background:
Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.
Methods:
Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).
Results:
The 10 individuals’ age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, p = 0.076;ICC = 0.408, p = 0.131; and ICC = 0.296, p = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, p = 0.039 and ICC = 0.702, p = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, p = 0.002 and ICC = 0.565, p = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, p = 0.001; ICC = 0.800, p = 0.001; and ICC = 0.825, p = 0.001, respectively).The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, p = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, p = 0.029 and ICC = 0.682, p = 0.008, respectively).
Conclusions
SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.
8.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
9.Clinical and radiologic outcomes of partial trapeziectomy and suture button suspensionplasty for the treatment of thumb carpometacarpal joint arthritis: a study with a minimum 2-year follow-up
Yeongyoon KOH ; Seul Gi PARK ; Jae Jun NAM ; Jong Woong PARK ; In Cheul CHOI
Archives of hand and microsurgery 2025;30(1):22-28
Purpose:
This study investigated the clinical and radiologic outcomes of partial trapeziectomy and suspensionplasty with a suture button for thumb carpometacarpal (CMC) joint osteoarthritis over a 2-year follow-up period.
Methods:
This retrospective study involved 17 patients with thumb CMC joint osteoarthritis (Eaton and Littler stage II or III) treated with partial trapeziectomy and suspensionplasty using a suture button. Clinical outcomes were evaluated using a visual analog scale for pain, the Quick DASH score, pinch and grip strength, and thumb range of motion. The trapezial space ratio (TSR) was used as a radiologic parameter to evaluate radiologic outcomes immediately postoperatively, at 6 months, and at the final follow-up.
Results:
The study included 17 patients (female, 16 and male, 1) with an average age of 63.2 years (range, 56–70 years). Surgery was performed on the dominant hand in nine cases and the nondominant hand in eight. Significant improvements were observed in clinical outcomes. The TSR significantly decreased up to 6 months postoperatively, but there was no significant change from 6 months onward. Complications included button irritation (n=1), a metacarpal fracture (n=1), and flexor carpi radialis tendon rupture (n=1), which were subsequently treated. At the last follow-up, significant improvements in functional outcomes were observed in comparison to the preoperative status.
Conclusion
The procedure demonstrated significantly improved clinical outcomes over a 2-year follow-up. This method is less invasive than other surgical techniques because it preserves part of the trapezium, making it a favorable surgical option in patients with early basal thumb arthritis (below Eaton stage III).
10.Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location
Seul-Gi KIM ; Bongkyung PARK ; Kyosun HWANG ; Woong Kyo JEONG
Clinics in Orthopedic Surgery 2025;17(1):166-173
Background:
Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.
Methods:
Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).
Results:
The 10 individuals’ age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, p = 0.076;ICC = 0.408, p = 0.131; and ICC = 0.296, p = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, p = 0.039 and ICC = 0.702, p = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, p = 0.002 and ICC = 0.565, p = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, p = 0.001; ICC = 0.800, p = 0.001; and ICC = 0.825, p = 0.001, respectively).The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, p = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, p = 0.029 and ICC = 0.682, p = 0.008, respectively).
Conclusions
SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.

Result Analysis
Print
Save
E-mail