1.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
2.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
3.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
4.Risk Factors of FEV 1 /FVC Decline in COPD Patients
Na Young KIM ; Deog Kyeom KIM ; Shinhee PARK ; Yong Il HWANG ; Hyewon SEO ; Dongil PARK ; Seoung Ju PARK ; Jin Hwa LEE ; Kwang Ha YOO ; Hyun Woo LEE
Journal of Korean Medical Science 2025;40(6):e32-
Background:
Factors influencing the decline in forced expiratory volume in one second (FEV1 )/forced vital capacity (FVC) for chronic obstructive pulmonary disease (COPD) progression remain uncertain. We aimed to identify risk factors associated with rapid FEV1 / FVC decline in patients with COPD.
Methods:
This multi-center observational study was conducted from January 2012 to December 2022. Eligible patients were monitored with symptoms, spirometric tests, and treatment patterns over 3 years. Rapid FEV1 /FVC decliners were defined as the quartile of patients exhibiting the highest annualized percentage decline in FEV1 /FVC.
Results:
Among 1,725 patients, 435 exhibited rapid FEV1 /FVC decline, with an annual change of −2.5%p (interquartile range, −3.5 to −2.0). Rapid FEV1 /FVC decliners exhibited lower body mass index (BMI), higher smoking rates, elevated post-bronchodilator (BD) FEV1 , higher post-BD FEV1 / FVC, and a lower prevalence of Staging of Airflow Obstruction by Ratio (STAR) stage IV. Rapid FEV1 /FVC decline was not linked to the annual exacerbation rate, but there was an association with symptom deterioration and FEV1 decline. In multivariable analyses, low BMI, current smoking, increased modified Medical Research Council dyspnoea score, low post-BD FEV1 , low STAR stage, high forced mid-expiratory flow (FEF 25-75% ), accelerated FEV1 decline, and not initiating dual BD therapy were identified as independent risk factors for rapid FEV1 /FVC decline.
Conclusion
We identified the risk factors for rapid FEV1 /FVC decline, including BMI, smoking, symptoms deterioration, FEV1 decline, and adherence to standard inhaler treatment. Our findings underscore the potential benefits of maintaining consistent use of long-acting beta-agonist/long-acting muscarinic antagonist even in the presence of worsening symptoms, in attenuating FEV1 /FVC decline.
5.Risk Factors of FEV 1 /FVC Decline in COPD Patients
Na Young KIM ; Deog Kyeom KIM ; Shinhee PARK ; Yong Il HWANG ; Hyewon SEO ; Dongil PARK ; Seoung Ju PARK ; Jin Hwa LEE ; Kwang Ha YOO ; Hyun Woo LEE
Journal of Korean Medical Science 2025;40(6):e32-
Background:
Factors influencing the decline in forced expiratory volume in one second (FEV1 )/forced vital capacity (FVC) for chronic obstructive pulmonary disease (COPD) progression remain uncertain. We aimed to identify risk factors associated with rapid FEV1 / FVC decline in patients with COPD.
Methods:
This multi-center observational study was conducted from January 2012 to December 2022. Eligible patients were monitored with symptoms, spirometric tests, and treatment patterns over 3 years. Rapid FEV1 /FVC decliners were defined as the quartile of patients exhibiting the highest annualized percentage decline in FEV1 /FVC.
Results:
Among 1,725 patients, 435 exhibited rapid FEV1 /FVC decline, with an annual change of −2.5%p (interquartile range, −3.5 to −2.0). Rapid FEV1 /FVC decliners exhibited lower body mass index (BMI), higher smoking rates, elevated post-bronchodilator (BD) FEV1 , higher post-BD FEV1 / FVC, and a lower prevalence of Staging of Airflow Obstruction by Ratio (STAR) stage IV. Rapid FEV1 /FVC decline was not linked to the annual exacerbation rate, but there was an association with symptom deterioration and FEV1 decline. In multivariable analyses, low BMI, current smoking, increased modified Medical Research Council dyspnoea score, low post-BD FEV1 , low STAR stage, high forced mid-expiratory flow (FEF 25-75% ), accelerated FEV1 decline, and not initiating dual BD therapy were identified as independent risk factors for rapid FEV1 /FVC decline.
Conclusion
We identified the risk factors for rapid FEV1 /FVC decline, including BMI, smoking, symptoms deterioration, FEV1 decline, and adherence to standard inhaler treatment. Our findings underscore the potential benefits of maintaining consistent use of long-acting beta-agonist/long-acting muscarinic antagonist even in the presence of worsening symptoms, in attenuating FEV1 /FVC decline.
6.Risk Factors of FEV 1 /FVC Decline in COPD Patients
Na Young KIM ; Deog Kyeom KIM ; Shinhee PARK ; Yong Il HWANG ; Hyewon SEO ; Dongil PARK ; Seoung Ju PARK ; Jin Hwa LEE ; Kwang Ha YOO ; Hyun Woo LEE
Journal of Korean Medical Science 2025;40(6):e32-
Background:
Factors influencing the decline in forced expiratory volume in one second (FEV1 )/forced vital capacity (FVC) for chronic obstructive pulmonary disease (COPD) progression remain uncertain. We aimed to identify risk factors associated with rapid FEV1 / FVC decline in patients with COPD.
Methods:
This multi-center observational study was conducted from January 2012 to December 2022. Eligible patients were monitored with symptoms, spirometric tests, and treatment patterns over 3 years. Rapid FEV1 /FVC decliners were defined as the quartile of patients exhibiting the highest annualized percentage decline in FEV1 /FVC.
Results:
Among 1,725 patients, 435 exhibited rapid FEV1 /FVC decline, with an annual change of −2.5%p (interquartile range, −3.5 to −2.0). Rapid FEV1 /FVC decliners exhibited lower body mass index (BMI), higher smoking rates, elevated post-bronchodilator (BD) FEV1 , higher post-BD FEV1 / FVC, and a lower prevalence of Staging of Airflow Obstruction by Ratio (STAR) stage IV. Rapid FEV1 /FVC decline was not linked to the annual exacerbation rate, but there was an association with symptom deterioration and FEV1 decline. In multivariable analyses, low BMI, current smoking, increased modified Medical Research Council dyspnoea score, low post-BD FEV1 , low STAR stage, high forced mid-expiratory flow (FEF 25-75% ), accelerated FEV1 decline, and not initiating dual BD therapy were identified as independent risk factors for rapid FEV1 /FVC decline.
Conclusion
We identified the risk factors for rapid FEV1 /FVC decline, including BMI, smoking, symptoms deterioration, FEV1 decline, and adherence to standard inhaler treatment. Our findings underscore the potential benefits of maintaining consistent use of long-acting beta-agonist/long-acting muscarinic antagonist even in the presence of worsening symptoms, in attenuating FEV1 /FVC decline.
7.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
8.Risk Factors of FEV 1 /FVC Decline in COPD Patients
Na Young KIM ; Deog Kyeom KIM ; Shinhee PARK ; Yong Il HWANG ; Hyewon SEO ; Dongil PARK ; Seoung Ju PARK ; Jin Hwa LEE ; Kwang Ha YOO ; Hyun Woo LEE
Journal of Korean Medical Science 2025;40(6):e32-
Background:
Factors influencing the decline in forced expiratory volume in one second (FEV1 )/forced vital capacity (FVC) for chronic obstructive pulmonary disease (COPD) progression remain uncertain. We aimed to identify risk factors associated with rapid FEV1 / FVC decline in patients with COPD.
Methods:
This multi-center observational study was conducted from January 2012 to December 2022. Eligible patients were monitored with symptoms, spirometric tests, and treatment patterns over 3 years. Rapid FEV1 /FVC decliners were defined as the quartile of patients exhibiting the highest annualized percentage decline in FEV1 /FVC.
Results:
Among 1,725 patients, 435 exhibited rapid FEV1 /FVC decline, with an annual change of −2.5%p (interquartile range, −3.5 to −2.0). Rapid FEV1 /FVC decliners exhibited lower body mass index (BMI), higher smoking rates, elevated post-bronchodilator (BD) FEV1 , higher post-BD FEV1 / FVC, and a lower prevalence of Staging of Airflow Obstruction by Ratio (STAR) stage IV. Rapid FEV1 /FVC decline was not linked to the annual exacerbation rate, but there was an association with symptom deterioration and FEV1 decline. In multivariable analyses, low BMI, current smoking, increased modified Medical Research Council dyspnoea score, low post-BD FEV1 , low STAR stage, high forced mid-expiratory flow (FEF 25-75% ), accelerated FEV1 decline, and not initiating dual BD therapy were identified as independent risk factors for rapid FEV1 /FVC decline.
Conclusion
We identified the risk factors for rapid FEV1 /FVC decline, including BMI, smoking, symptoms deterioration, FEV1 decline, and adherence to standard inhaler treatment. Our findings underscore the potential benefits of maintaining consistent use of long-acting beta-agonist/long-acting muscarinic antagonist even in the presence of worsening symptoms, in attenuating FEV1 /FVC decline.
9.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
10.Epidemiologic Trends and Socioeconomic Disparities of Ankylosing Spondylitis in South Korea:A Nationwide Population-Based Study, 2010–2021
Seoung Wan NAM ; Jihye LIM ; Dae Jin PARK ; Jun Young LEE ; Jae Hyun JUNG ; Dae Ryong KANG
Yonsei Medical Journal 2024;65(12):761-769
Purpose:
To investigate the epidemiological trends and socioeconomic disparities associated with ankylosing spondylitis (AS) in South Korea over a decade (2010–2021) using National Health Insurance Service (NHIS) claims data.
Materials and Methods:
Employing data from the NHIS database, this study identified 31753 incident AS patients in 2010–2021.We calculated the annual age-standardized prevalence and incidence rates and analyzed crude incidence rates and diagnostic patterns across age groups. Additionally, we compared the mean annual proportions of medical aid recipients between AS patients and the general population, utilizing p for trend analysis to assess the differences between the two groups across increasing age groups.
Results:
The study period saw a steady increase in age-standardized prevalence (from 34.6 to 91.0 per 100000) and incidence rates (from 4.41 to 8.33 per 100000 person-years), with the most substantial rise of incidence found in younger demographics. Diagnostic trends revealed a shift from internal medicine (IM) to other specialties including orthopedics with increasing patient age groups (p for trend=0.008), indicating old-age diagnosis in non-IM departments. A 1.4-fold higher proportion of medical aid recipients in AS patients (p<0.001) and the widening gap of dependency on medical aid in older age groups (p for trend=0.012) compared to the general population highlight socioeconomic disparities.
Conclusion
This comprehensive analysis reveals the growing epidemiological burden of AS, especially in younger populations, and the socioeconomic disparities regarding the disease in South Korea. It underscores the need for early diagnosis and effective treatment strategies, paving the way for health interventions and policies aimed at improving patient outcomes and addressing socioeconomic disparities.

Result Analysis
Print
Save
E-mail