1.Full mouth rehabilitation of patient with excessively worn dentition from multiple factors: a case report
Jiwon HA ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(2):154-163
Excessive wear of the teeth, which causes functional, aesthetic problems, or sensitivity symptoms, is referred to as pathological wear. If this leads to the collapse of occlusion, extensive restoration is necessary to restore function and aesthetics.When restoring pathologically worn dentition, it is essential to identify the cause of the wear before determining treatment plan to get a favorable prognosis. In this case, a patient exhibited severe tooth wear with decreased vertical dimension and clinical, radiographic examination, and medical history indicated the pathological wear caused by a combination of factors. Consequently, full-mouth rehabilitation was indicated and the vertical occlusal height was determined considering the appropriate restorative space. Based on the causes of the wear, the restoration method, materials, and occlusal pattern were selected and successfully restored to normal occlusal state through full-mouth rehabilitation with zirconia full-veneered crowns.
2.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
3.Complete mouth rehabilitation using jaw motion tracking and facial scan: a case report
Jongmin KIM ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(1):50-61
The occlusal collapse resulting from loss of posterior tooth support and attrition necessitates treatment aimed at restoring normal function and aesthetics.Particularly in cases where there is insufficient space for restoration, full mouth rehabilitation accompanied by increased vertical dimension is necessary. This case report presents a complete mouth rehabilitation of a patient with inadequate anterior restoration space due to loss of posterior tooth support, utilizing guided implant surgery, facial scan, virtual articulator, and jaw motion tracker.
4.Long-Term Incidence of Gastrointestinal Bleeding Following Ischemic Stroke
Jun Yup KIM ; Beom Joon KIM ; Jihoon KANG ; Do Yeon KIM ; Moon-Ku HAN ; Seong-Eun KIM ; Heeyoung LEE ; Jong-Moo PARK ; Kyusik KANG ; Soo Joo LEE ; Jae Guk KIM ; Jae-Kwan CHA ; Dae-Hyun KIM ; Tai Hwan PARK ; Kyungbok LEE ; Hong-Kyun PARK ; Yong-Jin CHO ; Keun-Sik HONG ; Kang-Ho CHOI ; Joon-Tae KIM ; Dong-Eog KIM ; Jay Chol CHOI ; Mi-Sun OH ; Kyung-Ho YU ; Byung-Chul LEE ; Kwang-Yeol PARK ; Ji Sung LEE ; Sujung JANG ; Jae Eun CHAE ; Juneyoung LEE ; Min-Surk KYE ; Philip B. GORELICK ; Hee-Joon BAE ;
Journal of Stroke 2025;27(1):102-112
Background:
and Purpose Previous research on patients with acute ischemic stroke (AIS) has shown a 0.5% incidence of major gastrointestinal bleeding (GIB) requiring blood transfusion during hospitalization. The existing literature has insufficiently explored the long-term incidence in this population despite the decremental impact of GIB on stroke outcomes.
Methods:
We analyzed the data from a cohort of patients with AIS admitted to 14 hospitals as part of a nationwide multicenter prospective stroke registry between 2011 and 2013. These patients were followed up for up to 6 years. The occurrence of major GIB events, defined as GIB necessitating at least two units of blood transfusion, was tracked using the National Health Insurance Service claims data.
Results:
Among 10,818 patients with AIS (male, 59%; mean age, 68±13 years), 947 (8.8%) experienced 1,224 episodes of major GIB over a median follow-up duration of 3.1 years. Remarkably, 20% of 947 patients experienced multiple episodes of major GIB. The incidence peaked in the first month after AIS, reaching 19.2 per 100 person-years, and gradually decreased to approximately one-sixth of this rate by the 2nd year with subsequent stabilization. Multivariable analysis identified the following predictors of major GIB: anemia, estimated glomerular filtration rate <60 mL/min/1.73 m2 , and a 3-month modified Rankin Scale score of ≥4.
Conclusion
Patients with AIS are susceptible to major GIB, particularly in the first month after the onset of AIS, with the risk decreasing thereafter. Implementing preventive strategies may be important, especially for patients with anemia and impaired renal function at stroke onset and those with a disabling stroke.
5.Comparison of initial treatments for resectable hepatocellular carcinoma within Milan criteria:an observational study based on a nationwide survey
Sang Jin KIM ; Woo Kyoung JEONG ; Hyung-Joon HAN ; Gyu-Seong CHOI ; Kyun-Hwan KIM ; Jongman KIM
Annals of Surgical Treatment and Research 2025;108(5):279-294
Purpose:
Treatment options for hepatocellular carcinoma (HCC) vary according to known guidelines among liver resection (LR), liver transplantation (LT), radiofrequency ablation (RFA), and transarterial chemoembolization (TACE). This study aimed to compare the outcomes of initial treatment for patients with resectable HCC within Milan criteria (MC) via nationwide data.
Methods:
Patients with resectable HCC (Child-Pugh class A; platelet count, ≥100,000/μL) within MC from the Korean Liver Cancer Association databank were analyzed, retrospectively. Outcomes according to initial treatment and subgroups according to tumor size and number were analyzed. Overall survival (OS) rates after initial treatment were compared.
Results:
A total of 3,241 patients who underwent LR (n = 1,371), LT (n = 12), RFA (n = 679), or TACE (n = 1,179) were included. The 5-year OS rates differed significantly between the groups (P < 0.05), except for LT (LR, 84.9%; LT, 82.5%;RFA, 76.2%; and TACE, 59.9%). For patients with a single tumor of any size, the 5-year OS rates of the LR group were significantly higher than RFA and TACE groups. For patients with multiple tumors, the 5-year OS rates were 78.2%, 100%, 74.3%, and 53.0% for the LR, LT, RFA, and TACE groups, respectively, but without significant difference between LR and RFA (P = 0.86).
Conclusion
For resectable HCC within MC, the LR had the highest OS rate for a single tumor of any size. LR and RFA showed no significant differences in OS rate for multiple tumors. LR has a much more optimistic outlook for HCC within MC.
6.Full mouth rehabilitation of patient with excessively worn dentition from multiple factors: a case report
Jiwon HA ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(2):154-163
Excessive wear of the teeth, which causes functional, aesthetic problems, or sensitivity symptoms, is referred to as pathological wear. If this leads to the collapse of occlusion, extensive restoration is necessary to restore function and aesthetics.When restoring pathologically worn dentition, it is essential to identify the cause of the wear before determining treatment plan to get a favorable prognosis. In this case, a patient exhibited severe tooth wear with decreased vertical dimension and clinical, radiographic examination, and medical history indicated the pathological wear caused by a combination of factors. Consequently, full-mouth rehabilitation was indicated and the vertical occlusal height was determined considering the appropriate restorative space. Based on the causes of the wear, the restoration method, materials, and occlusal pattern were selected and successfully restored to normal occlusal state through full-mouth rehabilitation with zirconia full-veneered crowns.
7.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
8.Complete mouth rehabilitation using jaw motion tracking and facial scan: a case report
Jongmin KIM ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(1):50-61
The occlusal collapse resulting from loss of posterior tooth support and attrition necessitates treatment aimed at restoring normal function and aesthetics.Particularly in cases where there is insufficient space for restoration, full mouth rehabilitation accompanied by increased vertical dimension is necessary. This case report presents a complete mouth rehabilitation of a patient with inadequate anterior restoration space due to loss of posterior tooth support, utilizing guided implant surgery, facial scan, virtual articulator, and jaw motion tracker.
9.Full mouth rehabilitation of patient with excessively worn dentition from multiple factors: a case report
Jiwon HA ; Jai-Young KOAK ; Seong-Kyun KIM ; Ji-Man PARK
The Journal of Korean Academy of Prosthodontics 2025;63(2):154-163
Excessive wear of the teeth, which causes functional, aesthetic problems, or sensitivity symptoms, is referred to as pathological wear. If this leads to the collapse of occlusion, extensive restoration is necessary to restore function and aesthetics.When restoring pathologically worn dentition, it is essential to identify the cause of the wear before determining treatment plan to get a favorable prognosis. In this case, a patient exhibited severe tooth wear with decreased vertical dimension and clinical, radiographic examination, and medical history indicated the pathological wear caused by a combination of factors. Consequently, full-mouth rehabilitation was indicated and the vertical occlusal height was determined considering the appropriate restorative space. Based on the causes of the wear, the restoration method, materials, and occlusal pattern were selected and successfully restored to normal occlusal state through full-mouth rehabilitation with zirconia full-veneered crowns.
10.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.

Result Analysis
Print
Save
E-mail