1.High-Resolution Chromosomal Microarray with Diagnostic Potential for Detecting Exon-Level Copy Number Variations Using Targeted and Non-targeted Approaches
Yeseul KIM ; Jee-Soo LEE ; Boram KIM ; Man Jin KIM ; Sung Im CHO ; Seung Won CHAE ; Ho Seob SHIN ; Hoyeon LEE ; Ji Yeon KIM ; Moon-Woo SEONG
Annals of Laboratory Medicine 2026;46(2):190-199
Background:
Copy number variations (CNVs) play an important role in human genetic disorders. Detection of exon-level CNVs is crucial for accurate clinical diagnosis. The CytoScan XON Array, a high-resolution microarray, was recently developed to detect exonic CNVs of various genes.
Methods:
We evaluated the clinical performance of the CytoScan XON Array using 59 patient samples with previously identified CNVs, confirmed via methods including multiple ligation-dependent probe amplification (MLPA), gene-dose PCR, and mRNA assay. Concordance between CytoScan XON and orthogonal methods was evaluated in target regions, and diagnostic utility was compared with that of genome sequencing (GS)-based CNV calling tools through analysis of false-positive CNVs in non-target genomic regions.
Results:
For target regions, the CytoScan XON Array achieved concordance rates of 89.8% and 92.5% at the exon and gene levels, respectively, for all CNV calls. Concordance was higher for multi-exon CNVs (100%) than that for single-exon CNVs (82.6%, P = 0.03). For non-target regions, false-positive CNV calls were reduced to fewer than 0.01 per gene per person through filtering strategies. The array exhibited false-positive detection rates within dosage-sensitive genes comparable with those of GS-based tools.
Conclusions
The CytoScan XON Array, a reliable tool for detecting exon-level CNVs in target regions, can serve as a complementary approach to GS-based CNV calling tools for genome-wide CNV screening with high resolution. However, its performance for single-exon CNVs requires further optimization. Cross-validation with GS-based CNV calling tools is recommended to improve diagnostic accuracy.
2.A unified framework for postoperative complications after gastrectomy for gastric cancer: insights from the Korean Quality Improvement Platform in Surgery program
Jeong Ho SONG ; Chang Seok KO ; Han Hong LEE ; Hong Man YOON ; Hyoung-Il KIM ; In Gyu KWON ; Ji Yeon PARK ; Ji Yeong AN ; Jong Won KIM ; Mi Ran JUNG ; Sang-Il LEE ; Seong Ho KONG ; Sun-Hwi HWANG ; Yun-Suhk SUH ; Sang-Yong SON ; Sang-Uk HAN
Annals of Surgical Treatment and Research 2026;110(5):290-298
Purpose:
Postoperative complications following gastric cancer surgery significantly impact patient outcomes, yet standardized definitions for these events have not been consistently applied across institutions in Korea. This study aimed to develop a consensus-based, standardized complication classification system specific to gastrectomy for gastric cancer as part of the Korean Quality Improvement Platform in Surgery (K-QIPS) initiative.
Methods:
As part of K-QIPS, a dedicated task force team (TFT) was formed with surgical experts from fourteen high-volume hospitals across Korea. The TFT conducted ten formal meetings to review existing literature and international guidelines, and incorporated findings from randomized controlled trials. The final complication list was developed through expert consensus and structured into a standardized framework. A Data Entry Manual was created to support consistent data collection by surgical clinical reviewers.
Results:
The TFT defined specific postoperative complications following gastrectomy for gastric cancer, including anastomotic leakage, duodenal stump leakage, pancreatic fistula, intra-abdominal and luminal bleeding, delayed gastric emptying, and internal hernia. Notably, internal hernia was described in standardized form for the first time. General complications were developed first and overlapped in part with the gastric cancer-specific list. The task force also produced a Data Entry Manual that provides practical instructions to ensure consistency and accuracy in complication reporting.
Conclusion
This nationwide consensus initiative established the first standardized complication classification system for gastric cancer surgery in Korea. The proposed definitions and data entry system are expected to improve complication reporting, enable multicenter research, support surgical quality benchmarking, and ultimately enhance patient outcomes.
3.Detection Ability of Quality of Life Changes and Responsiveness of the KOQUSS-40 and the EORTC QLQ-C30/STO22 in Patients Who Underwent Gastrectomy: A Prospective Comparative Study
Bang Wool EOM ; Keun Won RYU ; Ji Yeong AN ; Yun-Suhk SUH ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In-Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye-Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Joongyub LEE ; Hyuk-Joon LEE ;
Cancer Research and Treatment 2026;58(1):221-231
Purpose:
The aim of this study is to compare the detection ability of quality of life (QoL) changes and responsiveness of the KOrean QUality of life in Stomach cancer patients Study group (KOQUSS)-40 and European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ).
Materials and Methods:
A multicenter prospective observational study was conducted to evaluate QoL changes after various gastrectomies between January 2021 and April 2022. Participants were instructed to complete the KOQUSS-40 and EORTC QLQ-C30/STO22 preoperatively and at 1, 3, 6, and 12 months postoperatively. QoL changes over time and QoL responsiveness were assessed for each questionnaire.
Results:
Data from 491 patients who underwent curative gastrectomy for gastric cancer at 22 institutions were analyzed. The summary scores of the KOQUSS-40 and EORTC QLQ-STO22 showed significant differences between the total and proximal gastrectomy groups (p=0.044 and p=0.038, respectively), but no difference was observed for the EORTC QLQ-C30. Dysphagia on the KOQUSS-40 was significantly different between the total and proximal gastrectomy groups (p=0.031); however, dysphagia on the EORTC QLQ-STO22 did not differ. The responsiveness of the KOQUSS-40 was similar to that of the EORTC QLQ in patients who experienced ≥ 10% body weight loss, but approximately 10% less in patients receiving adjuvant chemotherapy than the EORTC QLQ.
Conclusion
KOQUSS-40 has several advantages over EORTC QLQ-C30/STO22 when comparing QoL between the total and proximal gastrectomy groups. The findings provide information for researchers investigating the QoL of patients who have undergone curative gastrectomy for gastric cancer.
4.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
5.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
6.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
7.Improved graft survival by using three-dimensional printing of intra-abdominal cavity to prevent large-for-size syndrome in liver transplantation
Sunghae PARK ; Gyu-Seong CHOI ; Jong Man KIM ; Sanghoon LEE ; Jae-Won JOH ; Jinsoo RHU
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(1):21-31
Background:
s/Aims: While large-for-size syndrome is uncommon in liver transplantation (LT), it can result in fatal outcome. To prevent such fatality, we manufactured 3D-printed intra-abdominal cavity replicas to provide intuitive understanding of the sizes of the graft and the patient’s abdomen in patients with small body size between July 2020 and February 2022.
Methods:
Clinical outcomes were compared between patients using our 3D model during LT, and patients who underwent LT without 3D model by using 1 : 5 ratio propensity score-matched analysis.
Results:
After matching, a total of 20 patients using 3D-printed abdominal cavity model and 100 patients of the control group were included in this study. There were no significant differences in 30-day postoperative complication (50.0% vs. 64.0%, p = 0.356) and the incidence of large-for-size syndrome (0% vs. 7%, p = 0.599). Overall survival of the 3D-printed group was similar to that of the control group (p = 0.665), but graft survival was significantly superior in the 3D-printed group, compared to the control group (p = 0.034).
Conclusions
Since it showed better graft survival, as well as low cost and short production time, our 3D-printing protocol can be a feasible option for patients with small abdominal cavity to prevent large-for-size syndrome after LT.
8.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
9.Biomechanics in terms of rotation angles and torques of implant-abutment screw tightening and loosening: Effects of implant types, contamination and sandblasting
Jiwoo LEE ; Seong-Kyun KIM ; Jai-Young KOAK ; Ji-Man PARK ; Jaejin CHO
The Journal of Korean Academy of Prosthodontics 2025;63(2):103-113
Purpose:
. The purpose of this study is to analyze the biomechanical differences in rotation angle-torque according to the type of implant and to compare the effects of contamination and sandblasting on the removal torque value (RTV) of abutment screws.
Materials and methods:
. For this study, an automated device for tightening and loosening implant screws was developed, and each 15 implant-abutment complexes of external and internal connection type were prepared, divided into three groups according to the surface treatment of the screw:control group (no treatment), experimental group-1 (artificial saliva contamination and chlorhexidine (CHX) rinsing), and experimental group-2 (artificial saliva contamination, CHX rinsing, and subsequent 50 µm Al 2 O 3 sandblasting). FirstRTV was measured for each group, followed by different post-treatment procedures for the screws, and then Second-RTV was measured. During the procedure, the removal torque value and rotation angle vs. time were recorded at a 20 data/s.A standardized protocol was followed for all the tightening and loosening procedures: screw was tightened with 30 Ncm torque and maintained for 5 s, and then rotated in the reverse direction until the torque value reached 0 Ncm. After 10min of rest period, the screws were loosened to initial point.
Results:
. Statistical analysis of measured data revealed that the internal connection type showed significantly higher First-RTV compared to the external connection type, however, no significant differences in Second-RTV were found. Both experimental groups 1and 2 showed a decrease in RTVs for both implant types, while the control group showed a decrease in RTV only for the internal type. The internal connection type required a significantly larger rotation angle during the tightening and loosening process.
Conclusion
. Within the limitations of this study, both artificial saliva contamination and CHX cleansing, as well as sandblasting, decreased RTV in both internal and external connection types. Internal connections were more susceptible to the effects of contaminants.
10.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283

Result Analysis
Print
Save
E-mail