1.Simultaneous Prostate Target Biopsy Integrated With Radical Prostatectomy: A Pilot Study Omitting Preoperative Systematic Biopsy
Tae Young PARK ; Jae Young HWANG ; Seong Woo YUN ; Chang Wan HYUN ; Sung Goo YOON ; Seung Bin KIM ; Tae Il NOH ; Ji Sung SHIM ; Min Goo PARK ; Seok Ho KANG ; Sung Gu KANG
Journal of Urologic Oncology 2024;22(3):196-200
Purpose:
This study evaluates the viability of a new method that employs transperineal targeted biopsy with frozen section analysis immediately followed by robot-assisted radical prostatectomy (RARP), bypassing the traditional systematic biopsy deemed essential by current guidelines.
Materials and Methods:
Patient selection was based on the following inclusion criteria: those who underwent magnetic resonance imaging (MRI)-ultrasound fusion-targeted biopsy with frozen section analysis and concurrent RARP. Eligibility also required features indicative of Prostate Imaging-Reporting and Data System (PI-RADS) 5 lesion on multiparametric MRI, along with one of these additional criteria: (1) MRI evidence suggesting extracapsular extension (ECE) with a prostate-specific antigen (PSA) level >10 ng/mL, or (2) a PSA level > 20 ng/mL.
Results:
Twelve patients were enrolled in this study according to inclusion criteria. The median age (interquartile range) was 73.5 (69.5–75.3) years and PSA was 22.9 (17.0–29.9) ng/mL. Three patients had PI-RADS 5 lesions, and 9 had PI-RADS 5 lesions with findings of ECE. In all cases, the diagnosis based on frozen sections confirmed adenocarcinoma. Following confirmation, each patient underwent immediate RARP. According to the final pathology report, 2 patients had International Society of Urological Pathology (ISUP) grade 2 disease, 7 patients had ISUP grade 3, 1 had ISUP grade 4, and 2 had ISUP grade 5 disease. Four patients had stage pT2 disease, 3 had stage pT3a, and 5 had stage pT3b. The median immediate reporting time of the target biopsy frozen section was 20 (19.3–24.5) minutes. No perioperative complications related to target biopsy were observed.
Conclusion
For patients with a strong suspicion of prostate cancer and a PI-RADS 5 lesion, integrating simultaneous prostate frozen target biopsy with radical prostatectomy may offer a feasible treatment alternative, obviating the necessity for a preoperative systematic biopsy.
2.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
3.Atrial fibrillation fact sheet in Korea 2024(part 1): epidemiology of atrial fibrillation in Korea
So‑Ryoung LEE ; Daehoon KIM ; Sung Ho LEE ; Woo‑Hyun LIM ; Kwang Jin CHUN ; Won‑Seok CHOE ; Hyo‑Jeong AHN ; Kyung‑Yeon LEE ; JungMin CHOI ; Bong‑Seong KIM ; Kyung‑Do HAN ; Eue‑Keun CHOI
International Journal of Arrhythmia 2024;25(3):13-
Background and objectives:
This study aimed to analyze and present updated trends in atrial fibrillation (AF) epidemiology within the Korean population, providing a foundation for planning and implementing appropriate management and treatment strategies for patients with AF.
Patients and methods:
We used the Korean National Health Insurance Service database to evaluate the prevalence, incidence, comorbidities, and clinical adverse outcomes of patients with AF in Korea between 2013 and 2022.
Results:
AF prevalence in Korean adults aged ≥ 20 years doubled (1.1 to 2.2%) between 2013 and 2022, with significant increases observed across various sex and age groups. Similarly, the number of newly diagnosed patients with AF per year increased steadily, with the incidence rising from 184 to 275 per 100,000 person-years, particularly among older populations. Over this period, the mean age of patients with AF increased from 67.7 to 70.3 years, and comorbidities prevalence and CHA2DS2-VASc score rose significantly, indicating a higher stroke risk. Compared with patients without AF, AF was associated with an increased risk of mortality (hazard ratio [HR]: 1.78), ischemic stroke (HR: 2.39), major bleeding (HR: 2.10), myocardial infarction (HR: 1.44), and heart failure admission (HR: 2.42).
Conclusion
AF prevalence and incidence have steadily increased between 2013 and 2022, with a more pronounced increase in older patients. Patients with AF are increasingly becoming a high-risk population and are at increased risk of clinical adverse outcomes compared to non-AF patients. Therefore, a sustained national effort to improve AF awareness and comprehensive care quality for patients with AF is required.
4.Interim Estimates of 2023–2024Seasonal Influenza Vaccine Effectiveness Among Adults in Korea
Yu Jung CHOI ; Jang Wook SOHN ; Won Suk CHOI ; Seong-Heon WIE ; Jacob LEE ; Jin-Soo LEE ; Hye Won JEONG ; Joong Sik EOM ; Eliel NHAM ; Hye SEONG ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Hee Jin CHEONG ; Woo Joo KIM
Journal of Korean Medical Science 2024;39(15):e146-
In the 2023–2024 season, the influenza epidemic in South Korea peaked earlier than in recent years. In this study, we aimed to estimate the interim vaccine effectiveness (VE) of the influenza vaccination to prevent influenza during the early season. From November 1, 2023, to December 31, 2023, we enrolled 2,632 subjects with influenza-like illness from eight hospitals participating in hospital-based influenza morbidity and mortality surveillance. A retrospective test-negative case-control study was conducted to estimate the VE. The results showed an adjusted VE of 22.5% (95% confidence interval [CI], 6.6 to 35.8) for the total population. The adjusted VE was 22.3% (95% CI, 6.1 to 35.7) for influenza A and 9.4% (95% CI, −51.3 to 45.7) for influenza A/H1N1. Full results of the analysis will be reported.
5.Establishment of Safety Monitoring System for Vaccines Not Included in the National Immunization Program in Korea
Eliel NHAM ; Jin Gu YOON ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Won Suk CHOI ; Hakjun HYUN ; Hye SEONG ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Hee Jin CHEONG
Journal of Korean Medical Science 2024;39(5):e45-
Background:
In Korea, there are no surveillance programs for vaccines that are not included in the national immunization program (NIP), and vaccine safety monitoring in the adult population is inadequate. This study aimed to establish a safety monitoring system for nonNIP vaccines in adults.
Methods:
Frequently administered non-NIP vaccines were selected. Individuals were included if they received at least one of the selected vaccines at a participating institution and provided informed consent. Solicited and unsolicited adverse events were monitored using questionnaires sent through text messages on days 1, 3, 7, 28, and 90 post-vaccination.Selected adverse events of special interest (AESIs) were monitored monthly by retrospective review of electronic medical records. Causality was assessed according to the Korea Disease Control and Prevention Agency guidelines.
Results:
Four vaccines (tetanus-diphtheria-pertussis [Tdap], pneumococcal conjugate 13-valent [PCV13], live zoster vaccine [ZVL], and recombinant zoster vaccine [RZV]) were selected, and their safety profiles were monitored at four tertiary hospitals and 10 primary care clinics. The response rates of the questionnaires on post-vaccination days 1, 7, 28, and 90 were 99.2%, 93.6%, 81.0%, and 48.7%, respectively. Of 555 AESI identified over 10 months, 10 cases received one of the selected non-NIP vaccines within 90 days of the event.
Conclusion
We are establishing the first safety monitoring system for selected non-NIP vaccines in Korea since September 2022 and report its progress as of July 2023. However, continuous government support is essential for its maintenance and improvement.
6.Effectiveness of Bivalent mRNA Booster Vaccine Against COVID-19 in Korea
Jin Gu YOON ; Jang Wook SOHN ; Won Suk CHOI ; Seong-Heon WIE ; Jacob LEE ; Jin-Soo LEE ; Hye Won JEONG ; Joong Sik EOM ; Hye SEONG ; Eliel NHAM ; Yu Jung CHOI ; Ji Yun NOH ; Joon Young SONG ; Hee Jin CHEONG ; Woo Joo KIM
Journal of Korean Medical Science 2024;39(3):e15-
Background:
Bivalent booster mRNA vaccines containing the omicron-variant strains have been introduced worldwide in the autumn of 2022. Nevertheless, the omicron subvariants evoked another large coronavirus disease 2019 (COVID-19) pandemic wave in late 2022 and early 2023.
Methods:
A retrospective, test-negative, case-control study was conducted to estimate the vaccine effectiveness (VE) of bivalent COVID-19 vaccines in 8 university hospitals between January and February 2023. The case and control groups were divided based on nasopharyngeal COVID-19 real-time polymerase chain reaction results and matched based on age, sex, hospital, and date (week) of the test performed. The VE of the BA.1- or BA.4/BA.5-based mRNA vaccines were estimated. VE was calculated using the 1−adjusted odds ratio from multivariable logistic regression.
Results:
In total, 949 patients and 947 controls were enrolled in this study. VE for the BA.4/ BA.5-based bivalent mRNA vaccine was 43% (95% confidence interval [CI], 17, 61%). In subgroup analysis based on age and underlying medical conditions, BA.4/BA.5-based bivalent mRNA vaccine was effective against old adults aged ≥ 65-years (VE, 55%; 95% CI, 23, 73%) and individuals with comorbidities (VE, 54%; 95% CI, 23, 73%). In comparison, the BA.1-based bivalent mRNA vaccine did not demonstrate statistically significant effectiveness (VE, 25%; 95% CI, −8, 49%).
Conclusion
The BA.4/BA.5-based bivalent mRNA booster vaccine provided significant protection against COVID-19 in the Korean adults, especially in the older adults aged ≥ 65 years and in individuals with underlying medical conditions.
7.Sex differences in chronic obstructive pulmonary disease characteristics: the Korea National Health and Nutrition Examination Survey 2007–2018
Moon Seong BAEK ; Haegwang SHIN ; Kang-Mo GU ; Hae In JUNG ; Won Young KIM ; Jae-Woo JUNG ; Jong-Wook SHIN ; Sun-Young JUNG ; Jae-Yeol KIM
The Korean Journal of Internal Medicine 2024;39(1):137-147
Background/Aims:
Chronic obstructive pulmonary disease (COPD) is less prevalent in females than males, but it affects mortality in females. There may be sex differences in the clinical characteristics of COPD.
Methods:
We analyzed the Korea National Health and Nutrition Examination Survey dataset from 2007 to 2018. We compared the clinical characteristics and comorbidities in subjects with COPD according to sex. We adjusted the multivariate logistic regression of lung cancer prevalence according to COPD and sex by age and smoking amount.
Results:
Females with COPD tended to be older than males with COPD (64.1 ± 0.4 yr vs. 62.3 ± 0.2 yr, respectively, p < 0.001). Approximately 89% of males with COPD had a smoking history, while 86% of females with COPD were non-smokers (p < 0.001). Household income was lower (p < 0.001) and asthma and overall malignancy were more prevalent in females with COPD than males with COPD (25.5 vs. 11.6%, respectively, p < 0.001; (6.3 vs. 5.4%, respectively, p < 0.001). However, lung cancer was more common in males with COPD than females with COPD (0.9 vs. 0.1%, respectively, p < 0.001). Lung cancer prevalence increased in males with moderate COPD compared to subjects without COPD (OR, 4.409; 95% CI, 1.741–9.419).
Conclusions
Females with COPD had a lower smoking rate, household income, and lung cancer prevalence than males with COPD. More active COPD screening is needed for women of low socioeconomic status, even if they do not smoke.
8.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
9.Time Series Changes in Indices of Diabetes Management from the 2008-2022 Korea Community Health Survey
So Yeon RYU ; Seong Woo CHOI ; So Jung JEONG ; Hyae Min GU
Journal of Agricultural Medicine & Community Health 2024;49(3):179-193
Objectives:
This study aimed to determine the time-series changes in provincial diabetes management indices using by results of the 2008-2022 Korea Community Health Survey.
Methods:
We collected diabetes diagnosis experience rate, treatment rate for people diagnosed with diabetes, annual screening rate for diabetic eye disease complications, and annual screening rate for diabetic kidney disease complications with age-standardized rates from the Regional Health Statistics. The unit of analysis was the nation and 17 provinces and the time-series trend analysis was performed by joinpoint regression using the Joinpoint Regression Program, and the annual percent change (APC) and average APC (AAPC) were estimated, and statistical significance was tested using 95% confidence interval (CI).
Results:
From 2008-2022, the national AAPC (95% CI) for diabetes diagnosis experience rate steadily increased to 2.77 (2.25-3.27), increasing in all regions, excluding Sejong. The national AAPC for treatment rate for people diagnosed with diabetes was 0.75 (0.47-1.04), with a slight but steady trend toward improvement, excluding Daejeon, Sejong, and Jeonbuk, which showed significant improvement. The national AAPCs for annual screening rates for diabetic eye disease and kidney disease complications were 1.82 (0.99-2.66) and 1.95 (0.60-3. 41), respectively, and the area with the largest change was Sejong.
Conclusions
In Korea, the diabetes management indices tended to increase and improve, but the trends among provinces varied. Therefore, efforts are needed to address regional disparities in diabetes management.
10.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.

Result Analysis
Print
Save
E-mail