1.The Korean Rectal Cancer Multidisciplinary Committee Clinical Practice Guidelines for Rectal Cancer version 2.0
Hyo Seon RYU ; Hyun Jung KIM ; Dong Hyun KANG ; Yoo-Kang KWAK ; Han Deok KWAK ; Yoon-Hye KWON ; Dalyon KIM ; Baek-Hui KIM ; Jae Hyun KIM ; Ji Hun KIM ; Jin Won KIM ; Tae Hyung KIM ; Hae Young KIM ; Soo Min NAM ; Gyoung Tae NOH ; Jun Woo BONG ; Nak Song SUNG ; Seon Hui SHIN ; Kil-Yong LEE ; Sung Chul LEE ; Sea-Won LEE ; Jung Won LEE ; Jong Min LEE ; Myung Hoon IHN ; Joo Han LIM ; Woong Bae JI ; Dae Hee PYO ; Young Ki HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2026;42(1):4-33
Rectal cancer, which accounts for approximately 40% of colorectal cancers, remains a major clinical concern. Recent advances in diagnostic imaging, surgical techniques, radiotherapy, and systemic treatment have steadily improved rectal cancer outcomes. Considering this, the Korean Rectal Cancer Multidisciplinary (KRCM) Committee has aimed to provide clinicians and policymakers with up-to-date, evidence-based clinical practice guidelines to support optimal decision-making, reflecting current evidence, the Korean healthcare context, and patient values and preferences. The Clinical Practice Guidelines for Rectal Cancer version 2.0 were developed through multidisciplinary collaboration with related academic societies, building upon and updating the KRCM Clinical Practice Guidelines version 1.0 (titled “Multidisciplinary guidelines for the management of rectal cancer”). These consensus guidelines of the KRCM were established based on a comprehensive literature review, evidence synthesis, with recommendation development guided by the GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology, and consideration of applicability in real-world clinical practice under the national health insurance system. Each recommendation has been presented with its strength and level of evidence.
2.Development and Application of a Cell-Based Assay for Detecting Anti-Agrin Antibodies Associated With Myasthenia Gravis
Seon Hui KIM ; Hye Yoon CHUNG ; MinGi KIM ; Seung Woo KIM ; Ha Young SHIN
Journal of Clinical Neurology 2025;21(2):105-112
Background:
and Purpose Anti-agrin antibodies (agrin Abs) have recently been identified in patients with myasthenia gravis (MG), sometimes in conjunction with antibodies (Abs) to the acetylcholine receptor (AChR), muscle-specific tyrosine kinase (MuSK), or low-density lipoprotein receptor-related protein 4. This study aimed to develop an in-house cell-based assay (CBA) for detecting agrin Abs, and to test its application to serum samples collected from individuals diagnosed with MG.
Methods:
Agrin complementary DNA as cloned into a pCMV6-AC-GFP vector, which was subsequently transfected into human embryonic kidney 293T (HEK293T) cells. Transfected HEK293T cells were incubated with patient serum and antihuman immunoglobulin G Ab conjugated with a red fluorescent dye. Agrin Ab levels were measured using the CBA in 389 serum samples: 340 from patients with MG, 36 from patients with other neuromuscular diseases, and 13 from healthy controls. The presence of agrin Ab was determined based on the fluorescence intensity and colocalization using fluorescence microscopy.
Results:
The expression levels of agrin mRNA and protein in transfected HEK293T cells were confirmed using the reverse-transcription polymerase chain reaction and Western blotting, respectively. Agrin expression in cells was further confirmed by immunocytochemistry.Two (0.6%) of the 340 patients with MG tested positive for agrin Ab: 1 of 191 AChR-positive patients and 1 of 54 MuSK-positive patients.
Conclusions
We have developed and validated a novel CBA for detecting agrin Abs. This CBA was successfully applied to detect agrin Abs in serum samples obtained from individuals with MG.
3.Development and Application of a Cell-Based Assay for Detecting Anti-Agrin Antibodies Associated With Myasthenia Gravis
Seon Hui KIM ; Hye Yoon CHUNG ; MinGi KIM ; Seung Woo KIM ; Ha Young SHIN
Journal of Clinical Neurology 2025;21(2):105-112
Background:
and Purpose Anti-agrin antibodies (agrin Abs) have recently been identified in patients with myasthenia gravis (MG), sometimes in conjunction with antibodies (Abs) to the acetylcholine receptor (AChR), muscle-specific tyrosine kinase (MuSK), or low-density lipoprotein receptor-related protein 4. This study aimed to develop an in-house cell-based assay (CBA) for detecting agrin Abs, and to test its application to serum samples collected from individuals diagnosed with MG.
Methods:
Agrin complementary DNA as cloned into a pCMV6-AC-GFP vector, which was subsequently transfected into human embryonic kidney 293T (HEK293T) cells. Transfected HEK293T cells were incubated with patient serum and antihuman immunoglobulin G Ab conjugated with a red fluorescent dye. Agrin Ab levels were measured using the CBA in 389 serum samples: 340 from patients with MG, 36 from patients with other neuromuscular diseases, and 13 from healthy controls. The presence of agrin Ab was determined based on the fluorescence intensity and colocalization using fluorescence microscopy.
Results:
The expression levels of agrin mRNA and protein in transfected HEK293T cells were confirmed using the reverse-transcription polymerase chain reaction and Western blotting, respectively. Agrin expression in cells was further confirmed by immunocytochemistry.Two (0.6%) of the 340 patients with MG tested positive for agrin Ab: 1 of 191 AChR-positive patients and 1 of 54 MuSK-positive patients.
Conclusions
We have developed and validated a novel CBA for detecting agrin Abs. This CBA was successfully applied to detect agrin Abs in serum samples obtained from individuals with MG.
4.Development and Application of a Cell-Based Assay for Detecting Anti-Agrin Antibodies Associated With Myasthenia Gravis
Seon Hui KIM ; Hye Yoon CHUNG ; MinGi KIM ; Seung Woo KIM ; Ha Young SHIN
Journal of Clinical Neurology 2025;21(2):105-112
Background:
and Purpose Anti-agrin antibodies (agrin Abs) have recently been identified in patients with myasthenia gravis (MG), sometimes in conjunction with antibodies (Abs) to the acetylcholine receptor (AChR), muscle-specific tyrosine kinase (MuSK), or low-density lipoprotein receptor-related protein 4. This study aimed to develop an in-house cell-based assay (CBA) for detecting agrin Abs, and to test its application to serum samples collected from individuals diagnosed with MG.
Methods:
Agrin complementary DNA as cloned into a pCMV6-AC-GFP vector, which was subsequently transfected into human embryonic kidney 293T (HEK293T) cells. Transfected HEK293T cells were incubated with patient serum and antihuman immunoglobulin G Ab conjugated with a red fluorescent dye. Agrin Ab levels were measured using the CBA in 389 serum samples: 340 from patients with MG, 36 from patients with other neuromuscular diseases, and 13 from healthy controls. The presence of agrin Ab was determined based on the fluorescence intensity and colocalization using fluorescence microscopy.
Results:
The expression levels of agrin mRNA and protein in transfected HEK293T cells were confirmed using the reverse-transcription polymerase chain reaction and Western blotting, respectively. Agrin expression in cells was further confirmed by immunocytochemistry.Two (0.6%) of the 340 patients with MG tested positive for agrin Ab: 1 of 191 AChR-positive patients and 1 of 54 MuSK-positive patients.
Conclusions
We have developed and validated a novel CBA for detecting agrin Abs. This CBA was successfully applied to detect agrin Abs in serum samples obtained from individuals with MG.
5.Review and latest trends of dental ceramic restorative materials
Seon-Mi BYEON ; Kyeong-Seon KIM ; Jae-Woo SHIN ; Jung-Hwan LEE ; Jeong-Hui JI ; Min-Soo BAE ; Yong-Seok JANG ; Min-Ho LEE ; Tae-Sung BAE
Korean Journal of Dental Materials 2024;51(1):1-14
Prosthodontic treatment is being performed for morphology and functional restoration due to damage and loss of teeth. As the aesthetic demands of patients increase, interest in ceramic materials with shades and translucency similar to natural teeth has increased.Recently, the manufacturing and processing technology of ceramic materials has greatly improved, and the market for dental ceramic materials is growing rapidly. The purpose of this literature review and evaluation is to provide information on the classification and properties of dental ceramic materials with excellent aesthetics and fracture resistance. In this article, it is classified as follows: I) Dental porcelain; II) Sinterable all-ceramic; III) Glass-ceramic for casting; IV) Glass-infiltrated alumina ceramic; V) Glass-ceramic ingots for heat-pressing technique; Vl) Blocks for CAD/CAM; Vll) Ceramic for CAD/3D printing. Dental ceramic materials and their restoration manufacturing methods have evolved significantly over the past decade. As a result, the manufacturing method of restorations has progressed from the layered firing technique of powdered materials or heat-pressing technique to the cutting and processing of single and multi-layer blocks using CAD/CAM technology, leading to the introduction of CAD/3D printing technology. In this manuscript, we will review the types of ceramic materials used in the fabrication of dental restorations and their advantages and disadvantages.
6.Evaluation of the antimalarial activity of SAM13-2HCl with morpholine amide (SKM13 derivative) against antimalarial drug-resistant Plasmodium falciparum and Plasmodium berghei infected ICR mice
Hyelee HONG ; Kwonmo MOON ; Thuy-Tien Thi TRINH ; Tae-Hui EOM ; Hyun PARK ; Hak Sung KIM ; Seon-Ju YEO
Parasites, Hosts and Diseases 2024;62(1):42-52
Antimalarial drugs are an urgently need and crucial tool in the campaign against malaria, which can threaten public health. In this study, we examined the cytotoxicity of the 9 antimalarial compounds chemically synthesized using SKM13-2HCl. Except for SKM13-2HCl, the 5 newly synthesized compounds had a 50% cytotoxic concentration (CC50) > 100 µM, indicating that they would be less cytotoxic than SKM13-2HCl. Among the 5 compounds, only SAM13-2HCl outperformed SKM13-2HCl for antimalarial activity, showing a 3- and 1.3-fold greater selective index (SI) (CC50/IC50) than SKM13-2HCl in vitro against both chloroquine-sensitive (3D7) and chloroquine -resistant (K1) Plasmodium falciparum strains, respectively. Thus, the presence of morpholine amide may help to effectively suppress human-infectious P. falciparum parasites. However, the antimalarial activity of SAM13-2HCl was inferior to that of the SKM13-2HCl template compound in the P. berghei NK65-infected mouse model, possibly because SAM13-2HCl had a lower polarity and less efficient pharmacokinetics than SKM13-2HCl. SAM13-2HCl was more toxic in the rodent model. Consequently, SAM13-2HCl containing morpholine was selected from screening a combination of pharmacologically significant structures as being the most effective in vitro against human-infectious P. falciparum but was less efficient in vivo in a P. berghei-infected animal model when compared with SKM13-2HCl. Therefore, SAM13-2HCl containing morpholine could be considered a promising compound to treat chloroquine-resistant P. falciparum infections, although further optimization is crucial to maintain antimalarial activity while reducing toxicity in animals.
7.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
8.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
9.Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia
Hojin KIM ; Sangjoon PARK ; Jihun KIM ; Jin Sung KIM ; Dong Wook KIM ; Nalee KIM ; Jae-Sun UHM ; Daehoon KIM ; Hui-Nam PAK ; Chae-Seon HONG ; Hong In YOON
Radiation Oncology Journal 2024;42(4):319-329
Purpose:
Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
Materials and Methods:
The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.
Results:
The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.
Conclusion
The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.
10.Treatment of side limb full-thickness prolapse of the side-to-end coloanal anastomosis following intersphincteric resection: a case report and review of literature
Guglielmo Niccolò PIOZZI ; Krunal KHOBRAGADE ; Seon Hui SHIN ; Jeong Min CHOO ; Seon Hahn KIM
Annals of Coloproctology 2024;40(Suppl 1):S38-S43
Intersphincteric resection (ISR) with coloanal anastomosis is an oncologically safe anus-preserving technique for very low-lying rectal cancers. Most studies focused on oncological and functional outcomes of ISR with very few evaluating long-term postoperative anorectal complications. Full-thickness prolapse of the neorectum is a relatively rare complication. This report presents the case of a 70-year-old woman presenting with full-thickness prolapse of the side limb of the side-to-end coloanal anastomosis occurring 2 weeks after the stoma closure and 2 months after a robotic partial ISR performed with the Da Vinci single-port platform. The anastomosis was revised through resection of the side limb and conversion of the side-to-end anastomosis into an end-to-end handsewn anastomosis with interrupted stitches. This study describes the first case of full-thickness prolapse of the side limb of the side-to-end handsewn coloanal anastomosis following ISR. Moreover, a revision of all reported cases of post-ISR full-thickness and mucosal prolapse was performed.

Result Analysis
Print
Save
E-mail