2.Comparative Analysis of Romosozumab Versus Vertebroplasty With Denosumab: Efficacy, Safety, and Secondary Bone Mineral Density Outcomes
Hyun Woong MUN ; Jong Joo LEE ; Hyun Chul SHIN ; Tae-Hwan KIM ; Seok Woo KIM ; Jae Keun OH
Neurospine 2025;22(1):69-77
Objective:
This study aimed to compare the efficacy and safety of romosozumab, a bone anabolic agent, versus vertebroplasty, a conventional surgical intervention, in treating osteoporotic vertebral compression fractures (OVCFs).
Methods:
A retrospective analysis included 86 thoracic/lumbar compression fracture patients from 2014 to 2022 at a medical center. Forty-two patients received romosozumab (monthly injections for 1 year) followed by 1 year of denosumab, while 44 underwent vertebroplasty followed by denosumab injections biannually for 2 years. Outcomes were assessed using the Numerical Rating Scale (NRS) for pain, bone mineral density (BMD), vertebral compression ratio, and Cobb angle over 12 months.
Results:
At 12 months, the romosozumab group showed a greater reduction in NRS scores (4.90 ± 1.01 vs. 4.27 ± 1.34, p = 0.015) and a higher increase in lumbar BMD (0.8 ± 0.5 vs. 0.5 ± 0.3, p = 0.000) compared to the vertebroplasty group. There were no significant differences in changes in hip total BMD and femur neck BMD (p = 0.190, p = 0.167, respectively). Radiographic assessments showed no significant differences in vertebral compression ratio (14.7% vs. 14.8%; p = 0.960) or Cobb angle (4.2° vs. 4.9°; p = 0.302). The incidence of major osteoporotic fractures was lower in the romosozumab group (7.1% vs. 25.0%, p = 0.051), with similar rates of cardiovascular events in both groups (4.8% vs. 9.1%, p = 0.716).
Conclusion
Romosozumab has demonstrated superior pain reduction and lumbar BMD improvement compared to vertebroplasty at 12 months, with no significant differences in radiographic outcomes or adverse events, suggesting it as an alternative to vertebroplasty for OVCF.
3.Bisphenol Analogs Downregulate the Self-Renewal Potential of Spermatogonial Stem Cells
Seo-Hee KIM ; Seung Hee SHIN ; Seok-Man KIM ; Sang-Eun JUNG ; Beom-Jin SHIN ; Jin Seop AHN ; Kyoung Taek LIM ; Dong-Hwan KIM ; Kichoon LEE ; Buom-Yong RYU
The World Journal of Men's Health 2025;43(1):154-165
Purpose:
In this study, we investigated the effect of bisphenol-A (BPA) and its major analogs, bisphenol-F (BPF), and bisphenol-S (BPS), on spermatogonial stem cells (SSCs) populations using in vitro SSC culture and in vivo transplantation models.
Materials and Methods:
SSCs enriched from 6- to 8-day-old C57BL/6-eGFP+ male mice testes were treated with varying concentrations of bisphenols for 7 days to examine bisphenol-derived cytotoxicity and changes in SSC characteristics. We utilized flow cytometry, immunocytochemistry, real-time quantitative reverse transcription-PCR, and western blot analysis. The functional alteration of SSCs was further investigated by examining donor SSC-derived spermatogenesis evaluation through in vivo transplantation and subsequent testis analysis.
Results:
BPF exhibited a similar inhibitory effect on SSCs as BPA, demonstrating a significant decrease in SSC survival, inhibition of proliferation, and induction of apoptosis. On the other hand, while BPS was comparatively weaker than BPA and BPF, it still showed significant SSC cytotoxicity. Importantly, SSCs exposed to BPA, BPF, and BPS exhibited a significant reduction in donor SSC-derived germ cell colonies per total number of cultured cells, indicating that, like BPA, BPF, and BPS can induce a comparable reduction in functional SSCs in the recipient animals. However, the progress of spermatogenesis, as evidenced by histochemistry and the expressions of PCNA and SSC specific markers, collectively indicates that BPA, BPF, and BPS may not adversely affect the spermatogenesis.
Conclusions
Our findings indicate that the major BPA substitutes, BPF and BPS, have significant cytotoxic effects on SSCs, similar to BPA. These effects may lead to a reduction in the functional self-renewal stem cell population and potential impacts on male fertility.
5.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Posterior Lumbar Element Enforcement by Decompression Alone with Interspinous Fixation without Interbody Fusion for the Surgical Management of Lumbar Spondylolisthesis
Hyun-Woong PARK ; Moon-Soo HAN ; Ji-Ho JUNG ; Jong-Hwan HONG ; Shin-Seok LEE ; Jung-Kil LEE
Journal of Korean Neurosurgical Society 2025;68(2):150-158
Objective:
: In degenerative lumbar spondylolisthesis, interbody fusion surgery (IFS) has long been recommended as the gold standard of surgical management. However, IFS is less recommended for high-risk patients such as the elderly because it involves extensive surgery, with a long operation time and high volumes of blood loss, which lead to marked perioperative morbidity. We report an alternative primary and salvage treatment technique for high-risk lumbar spondylolisthesis through posterior lumbar element reinforcement using interspinous fixation and decompression alone without interbody fusion.
Methods:
: Plain radiographs, computed tomography scans, and magnetic resonance imaging, taken at different intervals, were used to measure local disc height (DH), vertebral body slippage (BS), and segmental motion angle (SMA). A Visual analogue scale and the Oswestry disability index (ODI) were applied pre-operation and at the last follow-up.
Results:
: The local SMA decreased significantly by 3.46°±3.07°, from 10.61°±3.42° preoperatively to 7.15±3.70 at the last follow-up (p<0.001). The DH decreased from 8.61±2.88 mm preoperatively to 8.41±2.48 mm at the last follow-up (p=0.074). The BS decreased from 3.49±4.29 mm preoperatively to 3.41±4.91 mm at the last follow-up (p=0.092). None of the patients reported worsening pain or an increased ODI after surgery, and there were no surgery-related complications.
Conclusion
: Posterior lumbar element reinforcement by decompression alone with SPIRE™ fixation is an alternative primary and salvage treatment option for select patients with spondylolisthesis.
8.Posterior Lumbar Element Enforcement by Decompression Alone with Interspinous Fixation without Interbody Fusion for the Surgical Management of Lumbar Spondylolisthesis
Hyun-Woong PARK ; Moon-Soo HAN ; Ji-Ho JUNG ; Jong-Hwan HONG ; Shin-Seok LEE ; Jung-Kil LEE
Journal of Korean Neurosurgical Society 2025;68(2):150-158
Objective:
: In degenerative lumbar spondylolisthesis, interbody fusion surgery (IFS) has long been recommended as the gold standard of surgical management. However, IFS is less recommended for high-risk patients such as the elderly because it involves extensive surgery, with a long operation time and high volumes of blood loss, which lead to marked perioperative morbidity. We report an alternative primary and salvage treatment technique for high-risk lumbar spondylolisthesis through posterior lumbar element reinforcement using interspinous fixation and decompression alone without interbody fusion.
Methods:
: Plain radiographs, computed tomography scans, and magnetic resonance imaging, taken at different intervals, were used to measure local disc height (DH), vertebral body slippage (BS), and segmental motion angle (SMA). A Visual analogue scale and the Oswestry disability index (ODI) were applied pre-operation and at the last follow-up.
Results:
: The local SMA decreased significantly by 3.46°±3.07°, from 10.61°±3.42° preoperatively to 7.15±3.70 at the last follow-up (p<0.001). The DH decreased from 8.61±2.88 mm preoperatively to 8.41±2.48 mm at the last follow-up (p=0.074). The BS decreased from 3.49±4.29 mm preoperatively to 3.41±4.91 mm at the last follow-up (p=0.092). None of the patients reported worsening pain or an increased ODI after surgery, and there were no surgery-related complications.
Conclusion
: Posterior lumbar element reinforcement by decompression alone with SPIRE™ fixation is an alternative primary and salvage treatment option for select patients with spondylolisthesis.
9.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
10.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.

Result Analysis
Print
Save
E-mail