1.Two cases of common variable immunodeficiency in adults
Chang-Gyu JUNG ; Ji-Ho LEE ; Jae-Hyuk JANG ; Yoo Seob SHIN ; Hae-Sim PARK
Allergy, Asthma & Respiratory Disease 2026;14(1):38-43
Common variable immunodeficiency (CVID) is a heterogeneous primary immunodeficiency characterized by reduced levels of immunoglobulin (Ig)G, with or without IgA and/or IgM deficiency, and hypogammaglobulinemia. Clinical manifestations are diverse, ranging from recurrent infections to autoimmune and allergic diseases. While CVID has been rarely reported in the Korean population, particularly in adults, we report 2 adult cases of CVID comorbid with asthma and Behcet’s disease. The first case of a 53-year-old with severe allergic asthma and chronic rhinosinusitis experienced recurrent respiratory infections, stomatitis, and cystitis requiring frequent antibiotic treatment. Laboratory findings indicated a T2-high asthma phenotype, with elevated serum total IgE specific IgE to dog hair and fractional exhaled nitric oxide. Immunological evaluation revealed decreased serum IgG (including IgG1 and IgG2), along with hypogammaglobulinemia. She had been treated with regular anti-IgE antibody therapy and intravenous immunoglobulin replacement therapy (IVIGRT). The second case of a 38-year-old with Behçet’s disease and uveitis had bronchial asthma and rhinitis that were exacerbated by recurrent infections despite standard asthma therapy. Laboratory findings revealed a T2-low phenotype and a marked reduction in serum IgG (including IgG1, IgG2, and IgG4), and hypogammaglobulinemia, consistent with CVID.IVIGRT effectively reduced asthma exacerbations and infection episodes in both cases. These cases highlight the clinical heterogeneity of CVID and its potential overlap with allergic and autoimmune diseases. Immunological evaluation of underlying immunodeficiency should be considered in adult patients with asthma who present with frequent exacerbations and recurrent infections. Early diagnosis and IVIGRT can prevent complications and improve outcomes.
2.Molecular Epidemiology of Extended-spectrum β-Lactamase-producing Escherichia coli in South Korea: A Korean Global Antimicrobial Resistance Surveillance System Report
Dokyun KIM ; SungYoung LEE ; Jun Sung HONG ; Min Hyuk CHOI ; Hyun Soo KIM ; Young Ree KIM ; Young Ah KIM ; Young UH ; Kyeong Seob SHIN ; Jeong Hwan SHIN ; Jeong Su PARK ; Kyoung Un PARK ; Soo Hyun KIM ; Jong Hee SHIN ; Jungsik YU ; Seok Hoon JEONG
Annals of Laboratory Medicine 2026;46(1):72-82
Background:
Extended-spectrum β-lactamase (ESBL)-producing Escherichia coli is among the most important multidrug-resistant pathogens causing bloodstream infections (BSIs).Cefotaximase (CTX-M) enzymes are the most common and highly diverse ESBL family in E.coli. CTX-M-15 in group CTX-M-1 and CTX-M-14 in group CTX-M-9 are the most extensively disseminated enzymes. Multidrug-resistant E. coli strains complicate empirical therapy and increase healthcare burden globally and in Korea. We investigated the molecular epidemiology, sequence types (STs), and ESBL genotypes of E. coli bloodstream isolates in Korea and identified clinical risk factors for cefotaxime resistance.
Methods:
We collected all non-duplicated isolates of E. coli and related clinical information from patients with BSIs at eight sentinel hospitals in the Korean Global Antimicrobial Resistance Surveillance System (Kor-GLASS) collection network during 2017–2021. Duplicate isolates were removed to ensure representativeness of the data. Antimicrobial susceptibility was tested using disk diffusion tests, and multilocus sequence typing and betalactamase genotyping were performed.
Results:
Among 9,232 E. coli blood isolates, resistance rates to cefotaxime and ceftazidime were 36.4% and 11.4%, respectively. Among the clinical factors, age > 65 yrs (adjusted odds ratio [aOR], 1.36), hospital-origin infection (aOR, 2.55), and admission type (intensive care unit [ICU] vs. general ward; aOR, 1.34) were significant cefotaxime resistance risk factors. ST131 was the most prevalent among cefotaxime-resistant E. coli (64.8%, 2,180/3,363), followed by ST1193 (5.3%, N = 177), and ST69 (5.1%, N = 170).ST131, ST648, ST405, and ST410 cefotaxime-resistant E. coli isolates frequently harbored blaCTX-M-15, whereas ST1193 and ST68 showed a high proportion of blaCTX-M-27 carriers, and most ST457 and ST5150 isolates carried blaCTX-M-55.
Conclusions
Continuous monitoring of ESBL-producing E. coli is required to prevent further dissemination, guide empirical therapy, inform infection control policies, and ensure early detection of multidrug-resistant clones with the potential for widespread transmission.
3.Development and Performance Validation of a Comprehensive Liquid Biopsy Genotyping Panel for Pan-cancer Analysis
Seoyoung LIM ; Kwang Seob LEE ; Dongju WON ; Sung Hyun SEO ; Seung-Tae LEE ; Jong Rak CHOI ; Jieun SEO ; Saeam SHIN
Annals of Laboratory Medicine 2026;46(2):210-219
Background:
Precision oncology is advancing, increasing the demand for comprehensive, non-invasive genomic profiling tools. Liquid biopsy using circulating tumor DNA (ctDNA) enables real-time molecular profiling, treatment monitoring, and early detection of resistance variants. We developed the PAN100 panel (Dxome), a hybridization capture panel targeting 101 genes, as a pan-cancer genotyping assay to detect clinically actionable variants across various cancer types. This study presents the first comprehensive validation of the PAN100 panel including both analytical and clinical performance across eight cancer types using reference materials and matched tissue samples.
Methods:
For analytical validation, we assessed accuracy, limit of detection (LoD), and precision using Seraseq ctDNA v2 Reference Materials (SeraCare, Milford, MA, USA). Clinical validation was performed using plasma samples from 27 patients with eight types of cancer and 17 matched tumor samples. Positive percent agreement (PPA) between ctDNA and tissue next-generation sequencing (NGS) results was assessed using TruSight Oncology 500 and TruSight Tumor 170 assays. The limit of blank (LoB) was evaluated in 34 healthy individuals.
Results:
The PAN100 panel demonstrated high precision and linearity (LoD, 0.3%; 95.0% confidence interval, 0.29–0.35) variant allele frequency. The PPA between ctDNA and tissue NGS was 73.1% for single-nucleotide variants, 80.0% for insertions/deletions, and 74.2% overall. The LoB was 0.00001%.
Conclusions
The PAN100 panel is a robust tool for detecting clinically significant variants with high concordance with tissue NGS. Its sensitivity for low-frequency variants enables real-time treatment adaptation, supporting precision oncology. Its comprehensive design is particularly valuable for challenging diagnoses and clonal evolution monitoring.
4.High-Resolution Chromosomal Microarray with Diagnostic Potential for Detecting Exon-Level Copy Number Variations Using Targeted and Non-targeted Approaches
Yeseul KIM ; Jee-Soo LEE ; Boram KIM ; Man Jin KIM ; Sung Im CHO ; Seung Won CHAE ; Ho Seob SHIN ; Hoyeon LEE ; Ji Yeon KIM ; Moon-Woo SEONG
Annals of Laboratory Medicine 2026;46(2):190-199
Background:
Copy number variations (CNVs) play an important role in human genetic disorders. Detection of exon-level CNVs is crucial for accurate clinical diagnosis. The CytoScan XON Array, a high-resolution microarray, was recently developed to detect exonic CNVs of various genes.
Methods:
We evaluated the clinical performance of the CytoScan XON Array using 59 patient samples with previously identified CNVs, confirmed via methods including multiple ligation-dependent probe amplification (MLPA), gene-dose PCR, and mRNA assay. Concordance between CytoScan XON and orthogonal methods was evaluated in target regions, and diagnostic utility was compared with that of genome sequencing (GS)-based CNV calling tools through analysis of false-positive CNVs in non-target genomic regions.
Results:
For target regions, the CytoScan XON Array achieved concordance rates of 89.8% and 92.5% at the exon and gene levels, respectively, for all CNV calls. Concordance was higher for multi-exon CNVs (100%) than that for single-exon CNVs (82.6%, P = 0.03). For non-target regions, false-positive CNV calls were reduced to fewer than 0.01 per gene per person through filtering strategies. The array exhibited false-positive detection rates within dosage-sensitive genes comparable with those of GS-based tools.
Conclusions
The CytoScan XON Array, a reliable tool for detecting exon-level CNVs in target regions, can serve as a complementary approach to GS-based CNV calling tools for genome-wide CNV screening with high resolution. However, its performance for single-exon CNVs requires further optimization. Cross-validation with GS-based CNV calling tools is recommended to improve diagnostic accuracy.
5.Accuracy of Two Direct Antibiotic-Susceptibility Tests and Their Impact on the Optimal Treatment of Enterobacterales-Associated Bloodstream Infection:Comparison of the QMAC-dRAST V2.5 and BD Phoenix M50 Systems
Ji Sang YOON ; Joo An KWON ; Jeong Seob SHIN ; Hyun Soo SEOK ; In Young YOO ; Yeon-Joon PARK
Annals of Laboratory Medicine 2026;46(3):279-288
Background:
Rapid pathogen identification and antibiotic-susceptibility tests (ASTs) are important for treating bloodstream infections. We compared the performance of the QMAC-dRAST and BD Phoenix M50 direct AST (dPhoenix) systems using bacterial pellets prepared from positive blood culture broth and evaluated their impact on treatment modification.
Methods:
Direct AST results for 106 Enterobacterales isolates were retrospectively reviewed. Conventional broth microdilution was used to calculate categorical agreement (CA), very major error (VME), major error (ME), and minor error (mE). For isolates showing high VMEs in both methods, supplementary tests were performed. Clinical impact was evaluated by calculating the time required to obtain AST results (time-to-result) and observing changes in antibiotics prescribed after performing ASTs.
Results:
Both systems showed acceptable overall CA, VME, ME, and mE values (QMACdRAST: 93.6%, 1.6%, 0.9%, and 5.3%, respectively; dPhoenix: 93.1%, 0.9%, 0.6%, and 6.2%, respectively). Piperacillin–tazobactam showed high VMEs with QMAC-dRAST (4/20, 20.0%) and dPhoenix (3/20, 15.0%). Colony AST on 13 isolates revealed that QMACdRAST testing yielded lower minimal inhibitory concentrations (MICs) for piperacillin–tazobactam with three isolates, whereas dPhoenix testing yielded higher MICs with two isolates and lower MICs with two isolates. The average time-to-result was 20.8 hr and 30.1 hr for QMAC-dRAST and dPhoenix, respectively (P < 0.001). After AST, the number of optimal treatments increased from 43 (46.7%) to 72 (78.3%) (P < 0.001).
Conclusions
The QMAC-dRAST and dPhoenix systems provided reliable AST results with a short time-to-result. However, we recommend performing complementary tests, such as the disk diffusion test, for piperacillin–tazobactam.
6.Acute Lymphoblastic Leukemia Presenting as a Sinonasal Mass:A Case Report
Eun-Ha KOH ; Dae Seob CHOI ; Hwa Seon SHIN ; Jong-Sil LEE ; Eun-Sil PARK
Investigative Magnetic Resonance Imaging 2026;30(1):68-73
Acute lymphoblastic leukemia (ALL) primarily affects the bone marrow and peripheral blood. Extramedullary manifestations, especially in the sinonasal cavity, are rare and difficult to diagnose. We report a case of B-cell ALL in a 4-year-old girl who initially presented with a sinonasal mass mimicking a primary malignant neoplasm. The patient developed right eye protrusion upon nasal blowing over a period of 2 weeks. Imaging studies revealed an aggressive-appearing mass in the right maxillary sinus with extensive local invasion. The radiologic differential diagnosis included rhabdomyosarcoma, lymphoma, and other pediatric sinonasal malignancies. Histopathologic examination of the biopsy specimen and subsequent bone marrow evaluation established the diagnosis of B-cell ALL with BCR/ABL1 fusion. This case highlights the importance of including ALL in the differential diagnosis of sinonasal masses in pediatric patients, particularly when imaging features suggest an aggressive malignancy accompanied by hematologic abnormalities. A comprehensive evaluation, including imaging studies, routine laboratory tests, tissue biopsy, and bone marrow examination, is crucial for establishing an accurate diagnosis and initiating appropriate treatment.
7.Surface Functionalization of Three-Dimensional Printed Scaffold for Biomedical Application
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):53-57
Three-dimensional (3D) printing is one of the most effective scaffold manufacturing techniques which might revolutionize the realm of tissue engineering and regenerative medicine. The scaffolds, one of the major elements of tissue engineering, along with growth factors and cells, are still one of the most promising approaches for developing organ regeneration. However, the applications of 3D-printed hard scaffolds might have limitations due to their poor surface properties, which play a crucial role in cell recruitment and infiltration, tissue-scaffold integration, and anti-inflammatory properties. Various prerequisites have been suggested for clinical applications of 3D-printed substitute for human body. Consequently, continuous amendment has been made to modify the surface properties, porosities and mechanical properties of these scaffolds. The techniques that modify the surfaces through chemical and material modifications can also be applied to facilitate the efficacy of these scaffolds. In this review, we summarized the characteristics of 3D printing technology and discuss the development direction of the latest 3D printing technology toward meeting the unmet needs in the clinic.
8.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
9.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
10.Surface Functionalization of Three-Dimensional Printed Scaffold for Biomedical Application
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(2):53-57
Three-dimensional (3D) printing is one of the most effective scaffold manufacturing techniques which might revolutionize the realm of tissue engineering and regenerative medicine. The scaffolds, one of the major elements of tissue engineering, along with growth factors and cells, are still one of the most promising approaches for developing organ regeneration. However, the applications of 3D-printed hard scaffolds might have limitations due to their poor surface properties, which play a crucial role in cell recruitment and infiltration, tissue-scaffold integration, and anti-inflammatory properties. Various prerequisites have been suggested for clinical applications of 3D-printed substitute for human body. Consequently, continuous amendment has been made to modify the surface properties, porosities and mechanical properties of these scaffolds. The techniques that modify the surfaces through chemical and material modifications can also be applied to facilitate the efficacy of these scaffolds. In this review, we summarized the characteristics of 3D printing technology and discuss the development direction of the latest 3D printing technology toward meeting the unmet needs in the clinic.

Result Analysis
Print
Save
E-mail