2.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
3.A Case of a Cataract Patient with Equatorial and Posterior Zonular Weakness in Both Eyes
Jeong Woo KWON ; In Seok JEONG ; In Young CHUNG ; Seong Wook SEO ; Seong Jae KIM
Journal of the Korean Ophthalmological Society 2025;66(4):209-213
Purpose:
We present a case of equatorial and posterior zonular weakness observed during cataract surgery in both eyes with no prior history of trauma or surgery.Case summary: A 73-year-old woman visited out clinic and reported decreased visual acuity. She was found to have a best corrected visual acuity of 0.5 in both eyes. Cataracts were noted during a slit lamp examination and cataract surgery was subsequently performed. During the left eye surgery, although there was no evident weakening during the anterior capsulotomy, the equatorial and posterior zonules were damaged during phacoemulsification. This led to consistent aspiration of the equatorial and posterior capsule (PC) into the phaco-handpiece tip during epinucleus and cortex removal. The PC eventually ruptured necessitating anterior vitrectomy and a 3-piece intraocular lens insertion into the ciliary sulcus. Two weeks later, the right eye surgery encountered similar challenges in removing the epinucleus and cortex. The surgery was completed successfully by elevating the irrigation bottle, frequently injecting an ophthalmic viscoelastic device (OVD), and removing the remaining lens material using a bimanual irrigator/aspirator.
Conclusions
This case highlights that equatorial and posterior zonular weakness can occur in the absence of trauma or prior to surgery. To manage such cases, it is advisable to elevate the irrigation bottle height, continuously inject OVD during surgery, and use a bimanual irrigator/aspirator.
4.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
5.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
8.Nuclear Medicine Imaging in Differentiated Thyroid Cancer: Summary of the Korean Thyroid Association Guidelines 2024 from Nuclear Medicine Perspective, Part‑I
So Won OH ; Sohyun PARK ; Ari CHONG ; Keunyoung KIM ; Ji‑In BANG ; Youngduk SEO ; Chae Moon HONG ; Sang‑Woo LEE
Nuclear Medicine and Molecular Imaging 2025;59(1):1-7
Thyroid cancer, one of the most common endocrine tumors, generally has a favorable prognosis but remains a significant medical and societal concern due to its high incidence. Early diagnosis and treatment of differentiated thyroid cancer (DTC) significantly affect long-term outcomes, requiring the selection and application of appropriate initial treatments to improve prognosis and quality of life. Recent advances in technology and health information systems have enhanced our understanding of the molecular genetics of thyroid cancer, facilitating the identification of aggressive subgroups and enabling the accumulation of research on risk factors through big data. The Korean Thyroid Association (KTA) has revised the “KTA Guidelines on the Management of Differentiated Thyroid Cancers 2024” to incorporate these advances, which were developed by a multidisciplinary team and underwent extensive review and approval processes by various academic societies. This article summarizes the 2024 KTA guidelines for nuclear medicine imaging in patients with DTC, written by the Nuclear Medicine members of the KTA Guideline Committee, and covers 18 F-FDG PET/CT and radioiodine imaging with SPECT/CT in the management of DTC.
9.Radioactive Iodine Therapy in Differentiated Thyroid Cancer: Summary of the Korean Thyroid Association Guidelines 2024 from Nuclear Medicine Perspective, Part-II
So Won OH ; Sohyun PARK ; Ari CHONG ; Keunyoung KIM ; Ji‑In BANG ; Youngduk SEO ; Chae Moon HONG ; Sang‑Woo LEE
Nuclear Medicine and Molecular Imaging 2025;59(1):8-26
Thyroid cancer, one of the most common endocrine tumors, generally has a favorable prognosis but remains a significant medical and societal concern due to its high incidence. Early diagnosis and treatment of differentiated thyroid cancer (DTC) significantly affect long-term outcomes, requiring the selection and application of appropriate initial treatments to improve prognosis and quality of life. Recent advances in technology and health information systems have enhanced our understanding of the molecular genetics of thyroid cancer, facilitating the identification of aggressive subgroups and enabling the accumulation of research on risk factors through big data. The Korean Thyroid Association (KTA) has revised the “KTA Guidelines on the Management of Differentiated Thyroid Cancers 2024” to incorporate these advances, which were developed by a multidisciplinary team and underwent extensive review and approval processes by various academic societies.This article summarizes the 2024 KTA guidelines for radioactive iodine (RAI) therapy in patients with DTC, written by the Nuclear Medicine members of the KTA Guideline Committee, and covers RAI therapy as initial management of DTC and RAI therapy in advanced thyroid cancer.
10.Observer-Blind Randomized Control Trial for the Effectiveness of Intensive Case Management in Seoul: Clinical and Quality-of-Life Outcomes for Severe Mental Illness
Hye-Young MIN ; Seung-Hee AHN ; Jeung Suk LIM ; Hwa Yeon SEO ; Sung Joon CHO ; Seung Yeon LEE ; Dohhee KIM ; Kihoon YOU ; Hyun Seo CHOI ; Su-Jin YANG ; Jee Eun PARK ; Bong Jin HAHM ; Hae Woo LEE ; Jee Hoon SOHN
Psychiatry Investigation 2025;22(5):513-521
Objective:
In South Korea, there is a significant gap in systematic, evidence-based research on intensive case management (ICM) for individuals with severe mental illness (SMI). This study aims to evaluate the effectiveness of ICM through a randomized controlled trial (RCT) comparing ICM with standard case management (non-ICM).
Methods:
An RCT was conducted to assess the effectiveness of Seoul-intensive case management (S-ICM) vs. non-ICM in individuals with SMI in Seoul. A total of 78 participants were randomly assigned to either the S-ICM group (n=41) or the control group (n=37). Various clinical assessments, including the Brief Psychiatric Rating Scale (BPRS), Montgomery–Åsberg Depression Rating Scale, Health of the Nation Outcome Scale, and Clinical Global Impression-Improvement (CGI-I), along with quality-of-life measures such as the WHO Disability Assessment Schedule, WHO Quality of Life scale, and Multidimensional Scale of Perceived Social Support (MSPSS) were evaluated over a 3-month period. Statistical analyses, including analysis of covariance and logistic regression, were used to determine the effectiveness of S-ICM.
Results:
The S-ICM group had significantly lower odds of self-harm or suicidal attempts compared to the control group (adjusted odds ratio [aOR]=0.30, 95% confidence interval [CI]: 0.21–1.38). Psychiatric symptoms measured by the BPRS and perceived social support measured by the MSPSS significantly improved in the S-ICM group. The S-ICM group also had significantly higher odds of CGI-I compared to the control group (aOR=8.20, 95% CI: 2.66–25.32).
Conclusion
This study provides inaugural evidence on the effectiveness of S-ICM services, supporting their standardization and potential nationwide expansion.

Result Analysis
Print
Save
E-mail