1.Annual review of basic research on lung transplantation of China in 2024
Jier MA ; Junmin ZHU ; Lan ZHANG ; Xiaohan JIN ; Xiangyun ZHENG ; Senlin HOU ; Zengwei YU ; Yaling LIU ; Haoji YAN ; Dong TIAN
Organ Transplantation 2025;16(3):386-393
Lung transplantation is the optimal treatment for end-stage lung diseases and can significantly improve prognosis of the patients. However, postoperative complications such as infection, rejection, ischemia-reperfusion injury, and other challenges (like shortage of donor lungs) , limit the practical application of lung transplantation in clinical practice. Chinese research teams have been making continuous efforts and have achieved breakthroughs in basic research on lung transplantation by integrating emerging technologies and cutting-edge achievements from interdisciplinary fields, which has strongly propelled the development of this field. This article will comprehensively review the academic progress made by Chinese research teams in the field of lung transplantation in 2024, with a focus on the achievements of Chinese teams in basic research on lung transplantation. It aims to provide innovative ideas and strategies for key issues in the basic field of lung transplantation and to help China's lung transplantation cause reach a higher level.
2.Construction of an evaluation index system for community visual health services in Shanghai
Chengyuan ZHANG ; Yuting WU ; Yajun PENG ; Tao YU ; Yi XU ; Senlin LIN ; Haidong ZOU ; Lina LU
Shanghai Journal of Preventive Medicine 2025;37(3):282-287
ObjectiveTo improve the quality and service performance of community visual health services in Shanghai, and to establish a set of reasonable and effective evaluation index system for community visual health services. MethodsCentered on the national and Shanghai-based visual health policies and based on the current status and development trends of community visual health service program in Shanghai, the candidate indicators were formed through literature review and expert interviews, firstly. The framework of an evaluation index system was formulated through qualitative research successively, which was further revised and perfected using the Delphi method. Coefficient weights were calculated using the analytic hierarchy process (AHP), culminating in the establishment of the community visual health evaluation index system, lastly. ResultsA total of 22 visual health experts from district-level center for disease control, hospital ophthalmology and leaders in charging of visual health service in community health centers participated in the Delphi questionnaire survey, with a questionnaire recovery rate of 100% and an expert authority coefficient of 0.86, indicating high credibility. After a round of correspondence to experts’ importance ratings and discussions, a comprehensive evaluation index system comprising 3 primary indicators, 12 secondary indicators, and 47 tertiary indicators, along with 5 additional indicators, was finalized. ConclusionAn index system tailored to effective evaluation for community visual health initiatives was drawn up in this study, which can promote the capacity building in community eye health services, facilitating the high-quality development of visual health courses, and enhancing residents’ eye health.
3.Practice of pre-basic course teaching in the standardized training of clinical pathology residents
Yong LIN ; Shanshan SUN ; Xi ZHANG ; Youli WU ; Shuanghui YE ; Senlin XU ; Xiaohong YAO ; Xiaochu YAN ; Xiuwu BIAN ; Guangjie DUAN
Chinese Journal of Medical Education Research 2024;23(4):563-567
In order to explore the role of pre-basic course teaching in the standardized training of residents in clinical pathology, we have independently designed and constructed a pre-basic course teaching system mainly focusing on anatomy and histoembryology, consisting of two levels of theoretical teaching (small lectures by students and systematic lectures by instructors) and two dimensions of practical training (sample collection teaching and case teaching). This teaching model centering on participatory lecturing, practice, summarization, assessment, and feedback has been demonstrated effective. The results showed that the theoretical and practical assessment scores of the experimental group [(458.80±17.60) and (415.40±19.30), respectively] were significantly higher than those of the control group [(444.50±20.90) and (398.80±23.70), respectively]. Among 28 students of grades 2019 to 2021 surveyed for teaching effectiveness, 96.43% were satisfied with the teaching model. The established teaching model provides new ideas for the reform of teaching methods in the standardized training of residents in clinical pathology.
4.Safety of high-carbohydrate fluid diet 2 h versus overnight fasting before non-emergency endoscopic retrograde cholangiopancreatography: A single-blind, multicenter, randomized controlled trial
Wenbo MENG ; W. Joseph LEUNG ; Zhenyu WANG ; Qiyong LI ; Leida ZHANG ; Kai ZHANG ; Xuefeng WANG ; Meng WANG ; Qi WANG ; Yingmei SHAO ; Jijun ZHANG ; Ping YUE ; Lei ZHANG ; Kexiang ZHU ; Xiaoliang ZHU ; Hui ZHANG ; Senlin HOU ; Kailin CAI ; Hao SUN ; Ping XUE ; Wei LIU ; Haiping WANG ; Li ZHANG ; Songming DING ; Zhiqing YANG ; Ming ZHANG ; Hao WENG ; Qingyuan WU ; Bendong CHEN ; Tiemin JIANG ; Yingkai WANG ; Lichao ZHANG ; Ke WU ; Xue YANG ; Zilong WEN ; Chun LIU ; Long MIAO ; Zhengfeng WANG ; Jiajia LI ; Xiaowen YAN ; Fangzhao WANG ; Lingen ZHANG ; Mingzhen BAI ; Ningning MI ; Xianzhuo ZHANG ; Wence ZHOU ; Jinqiu YUAN ; Azumi SUZUKI ; Kiyohito TANAKA ; Jiankang LIU ; Ula NUR ; Elisabete WEIDERPASS ; Xun LI
Chinese Medical Journal 2024;137(12):1437-1446
Background::Although overnight fasting is recommended prior to endoscopic retrograde cholangiopancreatography (ERCP), the benefits and safety of high-carbohydrate fluid diet (CFD) intake 2 h before ERCP remain unclear. This study aimed to analyze whether high-CFD intake 2 h before ERCP can be safe and accelerate patients’ recovery.Methods::This prospective, multicenter, randomized controlled trial involved 15 tertiary ERCP centers. A total of 1330 patients were randomized into CFD group ( n = 665) and fasting group ( n = 665). The CFD group received 400 mL of maltodextrin orally 2 h before ERCP, while the control group abstained from food/water overnight (>6 h) before ERCP. All ERCP procedures were performed using deep sedation with intravenous propofol. The investigators were blinded but not the patients. The primary outcomes included postoperative fatigue and abdominal pain score, and the secondary outcomes included complications and changes in metabolic indicators. The outcomes were analyzed according to a modified intention-to-treat principle. Results::The post-ERCP fatigue scores were significantly lower at 4 h (4.1 ± 2.6 vs. 4.8 ± 2.8, t = 4.23, P <0.001) and 20 h (2.4 ± 2.1 vs. 3.4 ± 2.4, t= 7.94, P <0.001) in the CFD group, with least-squares mean differences of 0.48 (95% confidence interval [CI]: 0.26–0.71, P <0.001) and 0.76 (95% CI: 0.57–0.95, P <0.001), respectively. The 4-h pain scores (2.1 ± 1.7 vs. 2.2 ± 1.7, t = 2.60, P = 0.009, with a least-squares mean difference of 0.21 [95% CI: 0.05–0.37]) and positive urine ketone levels (7.7% [39/509] vs. 15.4% [82/533], χ2 = 15.13, P <0.001) were lower in the CFD group. The CFD group had significantly less cholangitis (2.1% [13/634] vs. 4.0% [26/658], χ2 = 3.99, P = 0.046) but not pancreatitis (5.5% [35/634] vs. 6.5% [43/658], χ2 = 0.59, P = 0.444). Subgroup analysis revealed that CFD reduced the incidence of complications in patients with native papilla (odds ratio [OR]: 0.61, 95% CI: 0.39–0.95, P = 0.028) in the multivariable models. Conclusion::Ingesting 400 mL of CFD 2 h before ERCP is safe, with a reduction in post-ERCP fatigue, abdominal pain, and cholangitis during recovery.Trail Registration::ClinicalTrials.gov, No. NCT03075280.
5.A controlled study on the impacts of different scanning protocols on image quality and radiation dose in chest CT
Chulin XU ; Wentao MA ; Yongxian ZHANG ; Yunfu LIU ; Tianliang KANG ; Senlin GUO ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2024;44(9):789-796
Objective:To explore and compare the impacts of different scanning protocols on image quality and radiation dose in chest computed tomography (CT) scans.Methods:A retrospective analysis was conducted for the data of 65 randomly selected patients who underwent chest CT scans using a tube voltage of 120 kV, the automatic modulation technique for tube current, and z-axis radiation dose modulation at the Emergency Department of our hospital from June to July 2023. The enrolled cases were divided into two groups: the high-resolution group ( n = 34) and the conventional group ( n = 31), with the settings for scanning protocols identical to those for phantom scans. For patients in both groups, thin-layer images of the cross-sections in the lung and mediastinal windows were reconstructed using thickness/intervals of 1 mm/1 mm and 2 mm/1 mm, respectively. Meanwhile, high-resolution and conventional CT scans were conducted using a Catphan500 phantom under a tube voltage of 120 kV and a tube current of 150 mAs. Of both scanning protocols, the high-resolution CT scan utilized the lung nodule-orientated scanning mode, pitch of 1.5, and a detector combination providing a collimation of 16 × 0.75 mm. In contrast, the conventional CT scan was performed using the body-orientated scanning mode, pitch of 0.813, and a detector combination providing a collimation of 16 × 1.5 mm. Then, the high-contrast resolutions of the phantom images obtained using the two scanning protocols were objectively evaluated. Both coronal chest images in the lung window and cross-sectional images in the mediastinal window were reconstructed with a thickness/interval of 5 mm/5 mm for both groups. Then, the obtained images were imported into the Radimetrics system to compare the body size-specific dose estimation (SSDE), doses to sensitive organs on the body surface, and scanning time of both groups. For the cross-sectional images in the mediastinal window, the contrast-noise-ratio (CNR), signal-to-noise ratio (SNR), and figure-of-merit (FOM) were measured and calculated at the fixed anatomical parts. For the cross-sectional images in the lung window, their quality was subjectively evaluated by two senior diagnostic radiologists. Results:The result of phantom scans indicated that high-resolution CT scans yielded images with an approximately 5% increase in the spatial resolution in the xy-plane and a nearly 20% increase in the spatial resolution along the z-axis compared to conventional CT scans. The result of clinical data demonstrated that the conventional group exhibited significantly higher doses to the thyroid and the female breast ( t = 2.8, 2.3, P < 0.05), along with notably elevated SNR, CNR, and FOM values of the right trapezius, compared to the high-resolution group ( t = 4.1, 5.8, z=4.4, P < 0.001). However, the high-resolution group manifested significantly higher SNR, CNR, and FOM values of the thoracic aorta compared to the conventional group ( t = 3.4, 4.4, z=3.4, P < 0.001). In addition, the cross-sectional and coronal images in the lung window of the clinical cases in the high-resolution group exhibited more stable quality, with subjective scores exceeding 4 and the average scores of both groups not statistically significantly different. Conclusions:For chest CT examination, high-resolution CT scans are more suitable for observations focusing on the details of the lungs and mediastinum, while conventional CT is more suitable for those centering on soft tissues on the body surface.
6.Analysis of the trend of radiological diagnostic examination frequency and the related influencing factors
Yongxian ZHANG ; Yantao NIU ; Tianliang KANG ; Yunfu LIU ; Liping XU ; Lin XU ; Senlin GUO ; Dandan LIU ; Binbin YU ; Junfang XIAN
Chinese Journal of Radiological Medicine and Protection 2024;44(1):29-35
Objective:To investigate the trend of radiological diagnostic examination frequency and the related influencing factors in a general hospital in recent four years.Methods:The hospital information system and the radiology information system were used to collect the information on the numbers of the outpatients, the emergency patients, and the inpatients and the radiology examination information from 2019 to 2022. The examination frequency and proportion of various imaging equipment were counted by using the perspective table of data, and the examination items and the proportion of the radiological diagnostic examinations were calculated. The positive rates of the radiological examinations were measured from 2019 to 2022. The gender and age distribution of the patients were analyzed. Spearman correlation analysis was used to analyze the relationships between the numbers of the patients undergoing radiological examinations and the numbers of the outpatients, emergency patients and the inpatients.Results:The annual frequency of radiological diagnostic examinations from 2019 to 2022 were 307 306, 245 418, 317 250 and 325 625, respectively, with a total of 1 195 599. Among them, the proportions of CT, X-rays, bedside X-rays, bone density, gastrointestinal imaging and mammography were 59.74%, 38.04%, 1.39%, 0.42%, 0.21% and 0.19%, respectively. In each year, the proportion of CT in all radiological diagnostic examinations was 49.58%, 63.40%, 60.40% and 65.20%, respectively. The frequency of emergency CT and emergency chest CT was correlated with the number of emergency patients( r =0.63, 0.61, P<0.05), and the frequency of non-emergency CT was correlated with the number of outpatients and inpatients ( r =0.61, 0.66, P<0.05). The positive rates of the CT examinations were higher than 80% except the lowest of 79.95% in 2021. Conclusions:Radiological examinations especially CT examinations have increased significantly, and played an important role in the diagnosis of diseases. However, attention should be paid to the Justification of the CT examinations. Timely statistical analysis of radiological examination information can provide data supports and references for scientific management of radiological examinations.
7.Concurrent silencing of TBCE and drug delivery to overcome platinum-based resistance in liver cancer.
Senlin LI ; Siyu CHEN ; Zhihui DONG ; Xingdong SONG ; Xiuling LI ; Ziqi HUANG ; Huiru LI ; Linzhuo HUANG ; Ganyuan ZHUANG ; Ran LAN ; Mingyan GUO ; Wende LI ; Phei Er SAW ; Lei ZHANG
Acta Pharmaceutica Sinica B 2023;13(3):967-981
Platinum-based chemotherapy resistance is a key factor of poor prognosis and recurrence in hepatocellular carcinoma (HCC). Herein, RNAseq analysis revealed that elevated tubulin folding cofactor E (TBCE) expression is associated with platinum-based chemotherapy resistance. High expression of TBCE contributes to worse prognoses and earlier recurrence among liver cancer patients. Mechanistically, TBCE silencing significantly affects cytoskeleton rearrangement, which in turn increases cisplatin-induced cycle arrest and apoptosis. To develop these findings into potential therapeutic drugs, endosomal pH-responsive nanoparticles (NPs) were developed to simultaneously encapsulate TBCE siRNA and cisplatin (DDP) to reverse this phenomena. NPs (siTBCE + DDP) concurrently silenced TBCE expression, increased cell sensitivity to platinum treatment, and subsequently resulted in superior anti-tumor effects both in vitro and in vivo in orthotopic and patient-derived xenograft (PDX) models. Taken together, NP-mediated delivery and the co-treatment of siTBCE + DDP proved to be effective in reversing chemotherapy resistance of DDP in multiple tumor models.
8.Study on the effect of virtual grid on chest X-ray image quality
Tianliang KANG ; Yunfu LIU ; Yongxian ZHANG ; Senlin GUO ; Wentao MA ; Yantao NIU
Chinese Journal of Radiology 2023;57(5):547-552
Objective:To explore the image quality and its evaluation method using virtual grid under different tube voltages in the clinical chest X-ray exam.Methods:According to the conditions of chest X-ray photography commonly used in clinical practice, the corresponding thickness of plexiglass (20 cm, including CDRAD phantom) was determined as the experimental object. With a fixed tube loading of 4 mAs and the tube voltage from 60 to 125 kV, the experimental object was imaged in three ways: physical grid, none grid and virtual grid. The common physical parameters (CNR, σ, C, SNR), texture analysis (Angular second moment, texture Contrast, Correlation, Inverse difference moment, Entropy) and CDRAD phantom score (IQF inv) were evaluated. Two-way ANOVA test was used for each group of common physical parameters, and further pairwise comparisons were made. At the same time, applying virtual grids on the obtained images with chest anthropomorphic model and texture indexing the images with and without virtual grids, then rank sum test of paired sample can be conducted. Results:There were differences in image quality among the three groups of grid mode( P<0.05), and the physical grid delivered the best image quality. The tube voltage had an impact on all image quality evaluation indexes ( P<0.05). The tube voltage was positively correlated with CNR, SNR, angular second moment, inverse difference moment and IQF inv ( P<0.05), and negatively correlated with σ, C, texture contrast and entropy ( P<0.05). There was no significant correlation between the tube voltage and Correlation ( P>0.05). The chest anthropomorphic model images were used to evaluate the virtual grids, and the texture indexes (Angle second moment, Contrast, Correlation, Inverse difference moment, Entropy) were statistically significant (P<0.05). Conclusions:The virtual grid can improve the image quality of chest X-ray photography, and the image texture analysis method can be a useful supplement to the image quality evaluation parameters.
9.The effect of CT detector width and signal acquisition positions on image quality
Senlin GUO ; Yue REN ; Yongxian ZHANG ; Tianliang KANG ; Yunfu LIU ; Lei ZHU ; Yantao NIU
Chinese Journal of Radiology 2023;57(6):684-688
Objective:To evaluate the influence of different detector widths and signal acquisition positions of wide-detector CT in different scanning modes on CT number and noise, and to provide a basis for reasonable selection of scanning modes and related parameters in clinical practice.Methods:The body dose phantom was scanned by GE Revolution CT. The scan was performed with detector widths of 40, 80 and 160 mm in sequential scanning mode and with detector width/pitch combinations of 40 mm/0.516, 40 mm/0.984, 80 mm/0.508 and 80 mm/0.992 in spiral scanning mode. The phantom was placed at the central and peripheral of the selected detector widths, and the adjacent positions between two axial scans. The images of the phantom were evaluated subjectively and the CT numbers and SDs were measured. The differences between the measured values at different imaging parameters were compared. The multi-group Friedman test was used to compare CT numbers and SD under different scanning parameters in sequential scanning mode, and the Wilcoxon test was used to compare CT numbers and SD in spiral scanning mode.Results:There was no statistically significant difference in the geometric shapes of the phantom images obtained at any combination of parameters. In sequential scanning mode, the differences at different detector widths were statistically significant (χ 2=14.00, P=0.001) with CT numbers at 40 mm and 160 mm greater than CT numbers at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=12.04, P=0.002) with CT numbers at peripheral and adjacent greater than CT numbers at central ( P<0.05). In spiral scanning mode CT numbers at detector width at 80 mm were greater than CT numbers at 40 mm ( Z=-2.10, P=0.036). For SD, the differences at different detector widths were statistically significant in sequential scanning modes (χ 2=8.17, P=0.017) with SD at 160 mm greater than SD at 80 mm ( P<0.05). The differences at different signal acquisition positions were statistically significant (χ 2=13.50, P=0.001) with SD at peripheral greater than SD at central ( P<0.05). In spiral scanning mode SDs at pitches 0.984 and 0.992 were greater than SDs at 0.516 and 0.508 ( Z=-2.66, P=0.008). There were no significant differences among other groups. Conclusion:The selection of scanning mode, detector width and signal acquisition position of wide-detector CT will affect the image CT numbers and SDs.
10.Effect of neck CT arteriovenous simultaneous enhancement methods on image quality and radiation dose
Yunfu LIU ; Tianliang KANG ; Yongxian ZHANG ; Senlin GUO ; Lin FU ; Qinggang XU ; Yingying CAO ; Junfang XIAN ; Yantao NIU
Chinese Journal of Radiology 2023;57(7):756-761
Objective:To investigate the feasibility of simultaneous arteriovenous enhancement of neck CT with two-stage injection of contrast agent and its effect on image quality and radiation dose.Methods:A total of 30 patients undergoing neck CT enhancement scan due to space-occupying lesions in Beijing Tongren Hospital, Capital Medical University from February to April 2022 were prospectively included as the experimental group. The neck CT enhancement scan was performed with two-stage injection of contrast agent and arteriovenous simultaneous enhancement. The dosage of contrast agent was calculated according to the patient′s body weight, and the method of two-stage injection was adopted. The dosage of contrast agent in the first stage was 0.7 ml/kg, with normal saline in the middle stage, and the second stage (began at 35 s) was 0.3 ml/kg. A total of 30 patients with gender and age matching with the experimental group from December 2021 to January 2022 were retrospectively collected as the control group. The control group was treated with the traditional arterial phase and venous phase scanning method with the dosage of 1.0 ml/kg contrast agent. The arterial phase was scanned at the 30 s and the venous phase was scanned at the 60 s. The CT values of bilateral carotid arteries and jugular veins in the experimental group were measured, the CT values of bilateral carotid arteries in the arterial phase were measured in the control group, and the CT values of bilateral carotid arteries and jugular veins in the venous phase were measured. Carotid artery enhancement score was performed for images of experimental group and control group in arterial and venous phase, and jugular vein and lesion enhancement score was performed for images of experimental group and control group in venous phase. The effective dose was calculated for both groups. The difference of carotid artery CT values between images was compared by one-way analysis of variance, and LSD method was used for pairwise comparison. The CT values of jugular vein were compared using independent sample t test. Kruskal-Wallis test was used to compare carotid artery enhancement scores, and Nemenyi method was used for pairwise comparison. Jugular vein and lesion enhancement scores and effective dose were compared by Mann-Whitney U test. Results:The CT value of carotid artery of experimental group [left (276±24) HU, right (273±25) HU] was lower than that of control group in arterial phase [left (329±33) HU, right (327±32) HU], and higher than that in the venous phase [left (147±15) HU, right (148±16) HU]. All the differences were statistically significant ( P<0.001). The CT value of jugular vein of experimental group [left (206±18) HU, right (203±19)] was higher than that of control group in the venous phase [left (154±15) HU, right (151±15)], the difference was statistically significant ( t=11.88, 11.76, both P<0.001). There was no significant difference in carotid artery enhancement score between experimental group and control group in arterial phase ( P=0.624), but the carotid artery enhancement score of the experimental group was higher than that of the control group in the venous phase, and the difference was statistically significant ( P<0.001). The scores of jugular vein and lesion enhancement in experimental group were higher than those of control group in venous phase, and the difference was statistically significant ( Z=5.01, P<0.001). The effective dose of the experimental group [2.41(2.04, 2.72) mSv] was decreased by 52.2% compared with the control group [5.04(4.18, 5.44) mSv], and the difference was statistically significant ( Z=-6.24, P<0.001). Conclusions:The neck CT enhanced scan with two-stage injection of contrast agent and arteriovenous simultaneous enhancement method can obtain comprehensive images of arterial and venous phases, and realize simultaneous enhancement of carotid artery, jugular vein and lesions, and reduce radiation dose.

Result Analysis
Print
Save
E-mail