1.Efficacy and Safety of Latanoprostene Bunod 0.024% Ophthalmic Solution in Korean Patients
Jaehoon JUNG ; Heesuk KIM ; Sang Yeop LEE ; Hyoung Won BAE ; Chan Yun KIM ; Wungrak CHOI
Journal of the Korean Ophthalmological Society 2026;67(3):88-93
Purpose:
To evaluate the efficacy and safety of latanoprostene bunod 0.024% (LBN) in Korean patients with glaucoma or ocular hypertension in a real-world clinical setting.
Methods:
This retrospective study included patients who initiated LBN treatment between March 1, 2022, and December 31, 2024. Patients were categorized into monotherapy, switched therapy, and concomitant therapy groups. Changes in intraocular pressure (IOP) were assessed at baseline, month 1, and month 6 according to treatment group and diagnosis. The type and frequency of adverse events were also analyzed.
Results:
Among the 138 patients initially identified, 129 were included in the analysis. The mean IOP for all patients was 17.4 ± 4.9 mmHg at baseline, 16.0 ± 4.6 mmHg at month 1, and 14.6 ± 3.7 mmHg at month 6. The mean IOP reduction was -1.4 ± 2.8 mmHg at month 1 (p < 0.001) and -2.2 ± 3.3 mmHg at month 6 (p < 0.001). Subgroup analyses by treatment type (monotherapy, switched, and concomitant) and diagnosis revealed significant IOP reductions at both time points across all groups. Adverse events occurred in 22 patients (17.1%), with eye pain being the most frequent. No serious adverse events were observed, including systemic side effects, severe visual impairment, or significant ocular complications.
Conclusions
LBN significantly reduced IOP in Korean patients with glaucoma and ocular hypertension, irrespective of prior IOP-lowering medication use and was well tolerated with a favorable safety profile. These findings support the use of LBN as an effective treatment option for Korean patients with glaucoma or ocular hypertension in diverse clinical settings.
2.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
6.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
7.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
8.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
9.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
10.Ataxin-3 Overexpression via Adeno-associated Viral Vector Injection in the Primate Cerebellum: A Novel Model of Spinocerebellar Ataxia Type 3
Keonwoo KIM ; Aryun KIM ; Jinyoung WON ; Junghyung PARK ; Kyung Seob LIM ; Chang-Yeop JEON ; Jisun MIN ; Jee-Hyun CHO ; Youngkyu SONG ; Bon-Sang KOO ; Gyu-Seo BAE ; Eunsu JEON ; Kang-Jin JEONG ; Sung-Hyun PARK ; Hwal-Yong LEE ; Won Seok CHOI ; Dong-Seok LEE ; Youngjeon LEE
Experimental Neurobiology 2025;34(6):248-262
Spinocerebellar ataxia type 3 (SCA3) is an autosomal-dominant neurodegenerative disorder caused by an expanded polyglutamine repeat in the ataxin-3 gene. The resulting mutant ataxin-3 protein forms intraneuronal inclusions that lead to neurodegeneration in the cerebellum and other brain regions. This study aimed to develop a novel nonhuman primate model of SCA3 to address the limitations of existing knock-in and transgenic models using an adeno-associated virus (AAV) to deliver the mutant gene. AAV viral vectors carrying mutant ataxin-3 were stereotaxically injected into the cerebellum of monkeys. The animals were monitored over an 8-week period, during which behavioral and neuroimaging assessments were conducted. This was followed by a detailed pathological examination. The AAV vector successfully spread throughout the cerebellum, and the expression of mutant ataxin-3 was confirmed. Neuroimaging revealed a reduction in N-acetylaspartate (NAA) levels, whereas histological analysis showed significant damage to the Purkinje cell layer. Notably, the monkeys exhibited sleep disturbances, a prodromal symptom commonly observed in human patients with SCA3. AAV-mediated delivery of mutant ataxin-3 can effectively replicate the key pathological and clinical features of SCA3 in primates. This approach offers a promising new model for studying disease mechanisms and evaluating potential therapies.

Result Analysis
Print
Save
E-mail