1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
6.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
7.2025 Seoul Consensus on Clinical Practice Guidelines for Irritable Bowel Syndrome
Yonghoon CHOI ; Young Hoon YOUN ; Seung Joo KANG ; Jeong Eun SHIN ; Young Sin CHO ; Yoon Suk JUNG ; Seung Yong SHIN ; Cheal Wung HUH ; Yoo Jin LEE ; Hoon Sup KOO ; Kwangwoo NAM ; Hong Sub LEE ; Dong Hyun KIM ; Ye Hyun PARK ; Min Cheol KIM ; Hyo Yeop SONG ; Sung-Hoon YOON ; Sang Yeol LEE ; Miyoung CHOI ; Moo-In PARK ; In-Kyung SUNG ;
Journal of Neurogastroenterology and Motility 2025;31(2):133-169
Irritable bowel syndrome (IBS) is a chronic, disabling, and functional bowel disorder that significantly affects social functioning and reduces quality of life and increases social costs. The Korean Society of Neurogastroenterology and Motility published clinical practice guidelines on the management of IBS based on a systematic review of the literature in 2017, and planned to revise these guidelines in light of new evidence on the pathophysiology, diagnosis, and management of IBS. The current revised version of the guidelines is consistent with the previous version and targets adults diagnosed with or suspected of having IBS. These guidelines were developed using a combination of de novo and adaptation methods, with analyses of existing guidelines and discussions within the committee, leading to the identification of key clinical questions. Finally, the guidelines consisted of 22 recommendations, including 3 concerning the definition and risk factors of IBS, 4 regarding diagnostic modalities and strategies, 2 regarding general management, and 13 regarding medical treatment. For each statement, the advantages, disadvantages, and precautions were thoroughly detailed. The modified Delphi method was used to achieve expert consensus to adopt the core recommendations of the guidelines. These guidelines serve as a reference for clinicians (including primary care physicians, general healthcare providers, medical students, residents, and other healthcare professionals) and patients, helping them to make informed decisions regarding IBS management.
8.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
9.A Phase II Study to Evaluate the Efficacy of Bortezomib in Combination with Thalidomide in Treatment-Naïve Waldenstrom Macroglobulinemia Patients
Ja Min BYUN ; Junghoon SHIN ; Sang-A KIM ; Hyunkyung PARK ; Jiyun LEE ; Dong-Yeop SHIN ; Junshik HONG ; Jeong-Ok LEE ; Soo-Mee BANG ; Inho KIM ; Sung-Soon YOON ; Youngil KOH
Cancer Research and Treatment 2024;56(2):675-680
Purpose:
Despite the recent success of Bruton’s tyrosine kinase (BTK) inhibitors for the treatment of Waldenstrom macroglobulinemia (WM), their indefinite treatment duration ultimately tantamount to substantial financial and emotional burden. On the other hand, fixed duration of proteasome inhibitors (PI) have shown rapid and reasonable response in WM treatment. Despite the well-known synergism between PI and immunomodulatory drugs (IMiD), there is no trials evaluating such combination in WM.
Materials and Methods:
Based on above, we designed this phase II study to investigate the efficacy and safety of 6 cycles of 28-day bortezomib-thalidomide-dexamethasone (VTD) regimen for treatment-naïve WM.
Results:
A total of 15 patients were enrolled: major response rate was 64.3%, and overall response rate was 78.6%. During the median follow-up of 41 months, median progression-free survival (PFS) was 13 months and overall survival 40 months. For responders, median duration of response was 13 months and median PFS 19 months. The most common adverse event (AE) of any grade was constipation (57.1%). The most common grade ≥ 3 AE was anemia (21.4%).
Conclusion
All in all, we hereby provide proof-of-concept that PI + IMiD may be an attractive backbone for fixed duration treatment. It should be noted that granting the same level of access to newer drugs globally is virtually impossible. Thus efforts to develop regimens using readily available drugs to yield similar or adequate treatment outcomes should not be disregarded. In this sense, we believe our study holds its place for its novelty and eloquently addresses achieving the daunting societal quest of health equity.
10.Differences in Type 2 Fiber Composition in the Vastus Lateralis and Gluteus Maximus of Patients with Hip Fractures
Jingwen TIAN ; Minchul SONG ; Kyu Jeong CHO ; Ho Yeop LEE ; Sang Hyeon JU ; Jung Ryul LIM ; Ha Thi NGA ; Thi Linh NGUYEN ; Ji Sun MOON ; Hyo Ju JANG ; Jung-Mo HWANG ; Hyon-Seung YI
Endocrinology and Metabolism 2024;39(3):521-530
Background:
Aging leads to sarcopenia, which is characterized by reduced muscle mass and strength. Many factors, including altered muscle protein turnover, diminished neuromuscular function, hormonal changes, systemic inflammation, and the structure and composition of muscle fibers, play a crucial role in age-related muscle decline. This study explored differences in muscle fiber types contributing to overall muscle function decline in aging, focusing on individuals with hip fractures from falls.
Methods:
A pilot study at Chungnam National University Hospital collected muscle biopsies from hip fracture patients aged 20 to 80 undergoing surgical treatment. Muscle biopsies from the vastus lateralis and gluteus maximus were obtained during hip arthroplasty or internal fixation. Handgrip strength, calf and thigh circumference, and bone mineral density were evaluated in individuals with hip fractures from falls. We analyzed the relationships between each clinical characteristic and muscle fiber type.
Results:
In total, 26 participants (mean age 67.9 years, 69.2% male) were included in this study. The prevalence of sarcopenia was 53.8%, and that of femoral and lumbar osteoporosis was 19.2% and 11.5%, respectively. Vastus lateralis analysis revealed an age-related decrease in type IIx fibers, a higher proportion of type IIa fibers in women, and an association between handgrip strength and type IIx fibers in men. The gluteus maximus showed no significant correlations with clinical parameters.
Conclusion
This study identified complex associations between age, sex, handgrip strength, and muscle fiber composition in hip fracture patients, offering insights crucial for targeted interventions combating age-related muscle decline and improving musculoskeletal health.

Result Analysis
Print
Save
E-mail