1.Three-year outcomes of a prospective, multicenter study of rotational atherectomy with antirestenotic therapy for infrainguinal arterial disease
Sungsin CHO ; Hyung-Kee KIM ; Woo-Sung YUN ; Ui Jun PARK ; Sang Su LEE ; Jaehoon LEE ; Hong-Pil HWANG ; Jin Hyun JOH
Annals of Surgical Treatment and Research 2026;110(3):180-187
Purpose:
Atherosclerotic plaques in peripheral arterial disease (PAD) include fatty, mixed, and calcified types. Plaque burden is significantly associated with restenosis, reintervention, and amputation-free survival. Rotational and aspirational atherectomy (RAA) may effectively remove such plaques. This study aimed to evaluate long-term outcomes of RAA for infrainguinal PAD.
Methods:
Patients with infrainguinal lesions underwent revascularization using the Jetstream Atherectomy System (Boston Scientific). This 60-month extension assessed primary patency rate (PPR) and clinically driven target lesion revascularization (CD-TLR). Kaplan-Meier curves were used for survival analysis; P < 0.05 was considered statistically significant.
Results:
A total of 150 patients (mean age, 70.9 years; male, 86.0%; 65.4% with diabetes) were enrolled. The mean lesion length was 15.8 cm, with 74.0% occlusions and 47.3% severe calcification. Lesions were sclerotic (72.4%), thrombosclerotic (13.4%), thrombotic (9.4%), or in-stent (4.7%). A drug-coated balloon (DCB) was used in 85.5% of cases. PPR at 1, 3, and 5 years was 84.1%, 68.1%, and 58.5%, respectively. CD-TLR rates were 93.0%, 81.5%, and 67.4%, respectively. The benefit of DCB was sustained through 3 years but attenuated thereafter, highlighting the need for extended follow-up in infrainguinal interventions.
Conclusion
RAA demonstrated durable 5-year patency and safety outcomes. Device type, DCB use, lesion morphology, and calcium grade did not significantly influence long-term results. Lesion complexity remains the primary predictor of clinical outcome. Despite the complexity of infrainguinal lesions, the use of RAA demonstrated sustained patency through 3 years, with lesion complexity (particularly TASC classification) emerging as the most critical predictor of long-term success.
2.Maxillary complete denture fabrication using CAD-based digital tooth arrangement in a patient with wide arch:a case report
Chaerin KIM ; Sang-Won PARK ; Hyun-Pil LIM ; Kwi-Dug YUN ; Chan PARK ; Woohyung JANG
The Journal of Korean Academy of Prosthodontics 2026;64(1):27-35
This case report describes the use of CAD-based digital tooth arrangement to overcome the limitations of conventional methods in a patient with a maxillary arch wider than the average Korean morphology. In such wide arches, average-based tooth arrangement often restricts the ability to adjust the occlusal plane and cusp positions, thereby limiting functional and esthetic reproduction.In this case, virtual tooth arrangement and occlusal analysis were performed using CAD software, and a putty index was fabricated on a 3D-printed reference model to guide the final arrangement. The fabricated maxillary cast metal complete denture and mandibular distal extension removable partial denture successfully achieved bilateral balanced occlusion, and the patient reported high satisfaction in both functional and esthetic aspects. This case highlights the clinical utility of digital tooth arrangement in atypically wide arches and suggests that CAD-assisted workflows can enhance accuracy and reproducibility in clinical prosthodontics.
3.Fabrication of removable partial denture using CAD-CAM customized artificial teeth: a case report
Seohyun KIM ; Sang-Won PARK ; Hyun-Pil LIM ; Kwi-Dug YUN ; Chan PARK ; Woohyung JANG
The Journal of Korean Academy of Prosthodontics 2026;64(1):95-103
With the advancement of digital technology, the clinical application of CAD-CAM systems in dentistry has been expanding. CAD-CAM technology is now being utilized not only for fixed dental prostheses but also in the fabrication of removable dentures. However, its use in removable partial dentures has primarily focused on fabricating metal frameworks, with insufficient research on intraoral fitness and long-term prognosis. Recently, CAD-CAM technology has enabled the fabrication of customized artificial teeth, offering several advantages such as the establishment of precise occlusal relationships, reduced laboratory time, and ease of reproduction. This case reports on a patient who presented with discomfort due to mobility of the mandibular anterior teeth and multiple missing posterior teeth. Given the patient’s economic and systemic conditions, fabrication of a mandibular removable partial denture was chosen as the treatment option.Clinical examination revealed occlusal wear and supraeruption in the maxillary dentition, resulting in an uneven occlusal plane. To achieve a more precise occlusal relationship and accurate tooth arrangement, customized artificial teeth were fabricated using CAD-CAM technology. Despite the uneven and non-ideal occlusal plane, a removable partial denture incorporating these CAD-CAM customized artificial teeth was successfully delivered, resulting in satisfactory functional and esthetic outcomes.
4.CBCT–IOS superimposition for integrated tissue analysis and emergence profile transfer from the provisional to the definitive prostheses in anterior esthetic restoration: case report
Chei HYUN ; Chan PARK ; Sang-Won PARK ; Hyun-Pil LIM ; Kwi-Dug YUN ; Woohyung JANG
The Journal of Korean Academy of Prosthodontics 2026;64(1):46-56
The integration of cone beam computed tomography (CBCT) and intraoral scanner (IOS) data through superimposition enables comprehensive evaluation of hard and soft tissue anatomy. While this technique has demonstrated clinical efficacy for implant and orthognathic surgery planning, its implementation in prosthetic treatment design and diagnosis remains limited. Through precise registration of CBCT and IOS data sets, clinicians can quantitatively assess alveolar bone dimensions, interproximal bone levels, and soft tissue biotype. This information enables establishment of patient-specific design criteria for prosthetic contours and interproximal contact areas. Additionally, this integrated approach facilitates evaluation of midline discrepancies, jaw asymmetries, and available restorative space for long-span fixed dental prostheses. Furthermore, the immediate gingival displacement that occurs following removal of the provisional prostheses necessitates standardized protocols for precise transfer of the subgingival emergence profile established by provisional prostheses to definitive prostheses. This clinical report describes CBCT-IOS superimposition-based digital analysis for anterior esthetic restorations, with successful transfer of subgingival emergence profile from the provisional to the definitive prostheses.
5.Anterior esthetic implant-supported fixed prostheses with customized PEEK healing abutments: a case report
Min-Jung SON ; Sang-Won PARK ; Hyun-Pil LIM ; Kwi-Dug YUN ; Chan PARK ; Woohyung JANG
The Journal of Korean Academy of Prosthodontics 2026;64(1):36-45
This case report describes a customized PEEK healing abutment fabricated using CAD-CAM technology to ensure the aesthetics of an anterior implant prosthesis.A 3-dimensional surgical guide was designed and printed to plan the ideal placement of implant, and the healing abutment was designed by CAD software to ensure the appropriate peri-gingival tissue at that location. The CAD-CAM Ti-base PEEK abutment was tightened right after the installation of implant fixture. After approximately 2 ‒ 3 months of observation, soft tissue healing and implant fixture stability were confirmed. The intraoral scanning before removing a healing abutment, after removing it which is for sub-gingival tissue, and with scan body were performed separately for the final prosthesis and all scan files were superimposed to design and fabricate the final prosthesis to ensure both aesthetic and functional performance. The final prosthesis fit comfortably without compressing the surrounding soft tissue, and the patient was functionally and esthetically satisfied with the outcome.
6.Ethnic Heterogeneity in Reproductive Risk Factors for Breast Cancer, With a Focus on Asian Populations:A Meta-analysis
Youjin HONG ; Soseul SUNG ; Woojin LIM ; Sungji MOON ; Kwang-Pil KO ; Jung Eun LEE ; Inah KIM ; Sun Ha JEE ; Sun-Seog KWEON ; Min-Ho SHIN ; Sangmin PARK ; Seung-Ho RYU ; Sun Young YANG ; Jeongseon KIM ; Sang-Wook YI ; Sue K. PARK
Journal of Cancer Prevention 2026;31(1):20-27
suggest that some reproductive factors associated with BC differ across ethnicities and time trends, perhaps due to the prevalence of reproductive factors and the baseline hazard of BC.
7.Adjusted Global Antiphospholipid Syndrome Score Is Associated with End-Stage Kidney Disease in Patients with ANCA-Associated Vasculitis:A Single-Centre Pilot Study
Pil Gyu PARK ; Hyun Joon CHOI ; Yong-Beom PARK ; Sang-Won LEE
Yonsei Medical Journal 2025;66(6):337-345
Purpose:
The adjusted Global Antiphospholipid Syndrome (APS) Score (aGAPSS) was developed for assessing the probability of thrombotic events in APS patients. This study investigated whether the aGAPSS at diagnosis was associated with poor outcomes during follow-up in patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV).
Materials and Methods:
This study included 170 AAV patients who had the results of APS-related antibodies at diagnosis but were not diagnosed with APS. All-cause mortality, end-stage kidney disease (ESKD), cerebrovascular accident, and acute coronary syndrome were considered poor AAV outcomes. The aGAPSS comprises five items, with 5, 4, 4, 3, and 1 points assigned to anticardiolipin antibodies, anti-β2-glycoprotein 1 antibodies, lupus anticoagulants, hyperlipidaemia, and arterial hypertension at AAV diagnosis, respectively.
Results:
The median age of the 170 patients [93 microscopic polyangiitis (MPA), 44 granulomatosis with polyangiitis (GPA), and 33 eosinophilic GPA (EGPA)] was 63.0 years. The optimal cut-off of the aGAPSS at diagnosis for ESKD during follow-up was set as two using the receiver operating characteristic curve. AAV patients with an aGAPSS ≥2 at diagnosis exhibited a significantly reduced ESKD-free survival rate compared to those with an aGAPSS <2 at diagnosis (p=0.045). Additionally, MPA and GPA patients, excluding EGPA patients for whom the median aGAPSS at diagnosis was close to 0, also showed similar patterns to the results among the 170 patients with AAV (p=0.021).
Conclusion
This study is the first to demonstrate that the aGAPSS at diagnosis was significantly associated with ESKD during follow-up in AAV patients without APS.
8.A customized guide device for single needle arthrocentesis on temporomandibular joint
Jun-Hyung JEON ; Sang-Hee PARK ; Pil-Young YUN ; Jeong-Kui KU
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(2):95-101
Objectives:
This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures.
Materials and Methods:
A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis.
Results:
Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure.
Conclusion
The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.
9.Adjusted Global Antiphospholipid Syndrome Score Is Associated with End-Stage Kidney Disease in Patients with ANCA-Associated Vasculitis:A Single-Centre Pilot Study
Pil Gyu PARK ; Hyun Joon CHOI ; Yong-Beom PARK ; Sang-Won LEE
Yonsei Medical Journal 2025;66(6):337-345
Purpose:
The adjusted Global Antiphospholipid Syndrome (APS) Score (aGAPSS) was developed for assessing the probability of thrombotic events in APS patients. This study investigated whether the aGAPSS at diagnosis was associated with poor outcomes during follow-up in patients with antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV).
Materials and Methods:
This study included 170 AAV patients who had the results of APS-related antibodies at diagnosis but were not diagnosed with APS. All-cause mortality, end-stage kidney disease (ESKD), cerebrovascular accident, and acute coronary syndrome were considered poor AAV outcomes. The aGAPSS comprises five items, with 5, 4, 4, 3, and 1 points assigned to anticardiolipin antibodies, anti-β2-glycoprotein 1 antibodies, lupus anticoagulants, hyperlipidaemia, and arterial hypertension at AAV diagnosis, respectively.
Results:
The median age of the 170 patients [93 microscopic polyangiitis (MPA), 44 granulomatosis with polyangiitis (GPA), and 33 eosinophilic GPA (EGPA)] was 63.0 years. The optimal cut-off of the aGAPSS at diagnosis for ESKD during follow-up was set as two using the receiver operating characteristic curve. AAV patients with an aGAPSS ≥2 at diagnosis exhibited a significantly reduced ESKD-free survival rate compared to those with an aGAPSS <2 at diagnosis (p=0.045). Additionally, MPA and GPA patients, excluding EGPA patients for whom the median aGAPSS at diagnosis was close to 0, also showed similar patterns to the results among the 170 patients with AAV (p=0.021).
Conclusion
This study is the first to demonstrate that the aGAPSS at diagnosis was significantly associated with ESKD during follow-up in AAV patients without APS.
10.A customized guide device for single needle arthrocentesis on temporomandibular joint
Jun-Hyung JEON ; Sang-Hee PARK ; Pil-Young YUN ; Jeong-Kui KU
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(2):95-101
Objectives:
This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures.
Materials and Methods:
A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis.
Results:
Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure.
Conclusion
The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.

Result Analysis
Print
Save
E-mail