1.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
2.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
3.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
4.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
5.Evaluation of Radioactivity in Therapeutic Radiopharmaceutical Waste
Jung Ju JO ; Su Hyoung LEE ; Beom Hoon KI ; Ho Jin RYU ; Tae Hwan KIM ; Gi Sub KIM ; Sang Kyu LEE ; Dong Wook KIM ; Kum Bae KIM ; Sangrok KIM ; Sang Hyoun CHOI
Progress in Medical Physics 2024;35(4):163-171
Purpose:
This study aims to systematically analyze the radioactive waste generated from treatments using radioactive Iodine-131 (I-131), Lutetium-177 (Lu-177), and Actinium-225 (Ac-225) to facilitate safe waste management practices.
Methods:
I-131 is primarily used in thyroid cancer treatment, while Lu-177 and Ac-225 are used to treat prostate cancer. Radioactive waste generated after these treatments was collected from patients at the Korea Cancer Center Hospital and categorized into clothing, slippers, syringes, and other items. The radioactivity concentration of each item was measured using a calibrated highpurity germanium detector. Using measurements, the self-disposal date of each waste item was calculated according to the permissible disposal levels defined by the Nuclear Safety and Security Commission (NSSC) under domestic nuclear safety regulations.
Results:
For the I-131 radioactive waste, clothing, towels, and tableware exhibited high radioactivity concentrations, with most items exceeding the permissible self-disposal levels.Conversely, the type and quantity of waste generated from Lu-177 and Ac-225 that were intravenously injected were relatively minimal, with certain items below the self-disposal thresholds, enabling immediate disposal. For Ac-225, no permissible self-disposal concentration is specified by the NSSC, unlike other therapeutic nuclides. Hence, additional studies are required to establish clear guidelines.
Conclusions
These findings provide valuable data for optimizing radioactive waste management, potentially reducing disposal time and costs, minimizing radiation exposure, and enhancing hospital safety practices.
6.Impact of User’s Background Knowledge and Polyp Characteristics in Colonoscopy with Computer-Aided Detection
Jooyoung LEE ; Woo Sang CHO ; Byeong Soo KIM ; Dan YOON ; Jung KIM ; Ji Hyun SONG ; Sun Young YANG ; Seon Hee LIM ; Goh Eun CHUNG ; Ji Min CHOI ; Yoo Min HAN ; Hyoun-Joong KONG ; Jung Chan LEE ; Sungwan KIM ; Jung Ho BAE
Gut and Liver 2024;18(5):857-866
Background/Aims:
We investigated how interactions between humans and computer-aided detection (CADe) systems are influenced by the user’s experience and polyp characteristics.
Methods:
We developed a CADe system using YOLOv4, trained on 16,996 polyp images from 1,914 patients and 1,800 synthesized sessile serrated lesion (SSL) images. The performance of polyp detection with CADe assistance was evaluated using a computerized test module. Eighteen participants were grouped by colonoscopy experience (nurses, fellows, and experts). The value added by CADe based on the histopathology and detection difficulty of polyps were analyzed.
Results:
The area under the curve for CADe was 0.87 (95% confidence interval [CI], 0.83 to 0.91). CADe assistance increased overall polyp detection accuracy from 69.7% to 77.7% (odds ratio [OR], 1.88; 95% CI, 1.69 to 2.09). However, accuracy decreased when CADe inaccurately detected a polyp (OR, 0.72; 95% CI, 0.58 to 0.87). The impact of CADe assistance was most and least prominent in the nurses (OR, 1.97; 95% CI, 1.71 to 2.27) and the experts (OR, 1.42; 95% CI, 1.15 to 1.74), respectively. Participants demonstrated better sensitivity with CADe assistance, achieving 81.7% for adenomas and 92.4% for easy-to-detect polyps, surpassing the standalone CADe performance of 79.7% and 89.8%, respectively. For SSLs and difficult-to-detect polyps, participants' sensitivities with CADe assistance (66.5% and 71.5%, respectively) were below those of standalone CADe (81.1% and 74.4%). Compared to the other two groups (56.1% and 61.7%), the expert group showed sensitivity closest to that of standalone CADe in detecting SSLs (79.7% vs 81.1%, respectively).
Conclusions
CADe assistance boosts polyp detection significantly, but its effectiveness depends on the user’s experience, particularly for challenging lesions.
7.High vegetable consumption and regular exercise are associated with better quality of life in patients with gout
Hyunsue DO ; Hyo Jin CHOI ; Byoongyong CHOI ; Chang-Nam SON ; Sang-Hyon KIM ; You-Jung HA ; Ji Hyoun KIM ; Min Jung KIM ; Kichul SHIN ; Hyun-Ok KIM ; Ran SONG ; Sung Won LEE ; Joong Kyong AHN ; Seung-Geun LEE ; Chang Hoon LEE ; Kyeong Min SON ; Ki Won MOON
The Korean Journal of Internal Medicine 2024;39(5):845-854
Background/Aims:
The Gout Impact Scale (GIS), a part of the Gout Assessment Questionnaire 2.0, is used to measure gout-specific health-related quality of life (HRQOL). Although several studies have been conducted on the factors affecting the HRQOL of patients with gout, few have focused on lifestyle factors. This study aimed to investigate the correlation between lifestyle habits and HRQOL using the GIS in patients with gout.
Methods:
We used data from the Urate-Lowering TheRApy in Gout (ULTRA) registry, a prospective cohort of Korean patients with gout treated at multiple centers nationwide. The patients were aged ≥18 years and met the 2015 American College of Rheumatology/European League Against Rheumatism gout classification criteria. They were asked to complete a GIS and questions regarding their lifestyle habits at enrollment.
Results:
The study included 232 patients. ‘Gout concern overall’ scores in the GIS were significantly lower in patients who exercised more frequently and consumed soft drinks and meat less, and ‘well-being during attack’ scores were significantly lower in patients who consumed vegetables and exercised more frequently. The frequency of vegetable consumption had a negative linear relationship with the ‘well-being during attack’ and ‘gout concern during attack’ scores (p = 0.01, p = 0.001, respectively). The frequency of exercise had a negative linear relationship with the ‘gout concern overall’ and ‘gout concern during attack’ scores (p = 0.04 and p = 0.002, respectively).
Conclusions
Patients with gout who frequently consumed vegetables and exercised regularly experienced less impact of gout, exhibiting a better GIS that represented HRQOL.
8.Various Three-Dimensional Culture Methods and Cell Types for Exosome Production
Dong-Hyun LEE ; Dae Won YUN ; Yeong Hwan KIM ; Gwang-Bum IM ; Jiyu HYUN ; Hyun Su PARK ; Suk Ho BHANG ; Sang Hyoun CHOI
Tissue Engineering and Regenerative Medicine 2023;20(4):621-635
Cell-based therapies have been used as promising treatments for several untreatable diseases. However, cellbased therapies have side effects such as tumorigenesis and immune responses. To overcome these side effects, therapeutic effects of exosomes have been researched as replacements for cell-based therapies. In addition, exosomes reduced the risk that can be induced by cell-based therapies. Exosomes contain biomolecules such as proteins, lipids, and nucleic acids that play an essential role in cell–cell and cell–matrix interactions during biological processes. Since the introduction of exosomes, those have been proven perpetually as one of the most effective and therapeutic methods for incurable diseases. Much research has been conducted to enhance the properties of exosomes, including immune regulation, tissue repair, and regeneration. However, yield rate of exosomes is the critical obstacle that should be overcome for practical cell-free therapy. Three-dimensional (3D) culture methods are introduced as a breakthrough to get higher production yields of exosomes. For example, hanging drop and microwell were well known 3D culture methods and easy to use without invasiveness. However, these methods have limitation in mass production of exosomes. Therefore, a scaffold, spinner flask, and fiber bioreactor were introduced for mass production of exosomes isolated from various cell types. Furthermore, exosomes treatments derived from 3D cultured cells showed enhanced cell proliferation, angiogenesis, and immunosuppressive properties. This review provides therapeutic applications of exosomes using 3D culture methods.
9.Tauroursodeoxycholic Acid Inhibits Nuclear Factor Kappa B Signaling in Gastric Epithelial Cells and Ameliorates Gastric Mucosal Damage in Mice
Su Hwan KIM ; Ji Won KIM ; Seong-Joon KOH ; Sang Gyun KIM ; Jeong Mo BAE ; Jung Ho KIM ; Jeong Hwan PARK ; Mee Soo CHANG ; Kee Don CHOI ; Hyoun Woo KANG ; Byeong Gwan KIM ; Kook Lae LEE
The Korean Journal of Gastroenterology 2022;79(4):161-169
Background/Aims:
Previous studies have reported the protective effects of tauroursodeoxycholic acid (TUDCA) on gastric epithelial cells in some animal models, but the precise mechanisms are unclear. This study examined the effects of TUDCA on NF-κB signaling in gastric epithelial cells. Moreover, the protective effects of TUDCA in experimental gastritis models induced by ethanol and NSAID were evaluated and compared with ursodeoxycholic acid (UDCA).
Methods:
After a pretreatment with TUDCA or UDCA, human gastric epithelial MKN-45 cells were stimulated with tumor necrosis factor (TNF)-α to activate NF-κB signaling. A real-time PCR (RT-PCR) for human interleukin (IL)-1 mRNA was performed. An electrophoretic mobility shift assay (EMSA) and immunoblot analyses were carried out. In murine models, after a pretreatment with TUDCA or UDCA, ethanol and indomethacin were administered via oral gavage. Macroscopic and microscopic assessments were performed to evaluate the preventive effects of TUDCA and UDCA on murine gastritis.
Results:
A pretreatment with TUDCA downregulated the IL-1α mRNA levels in MKN-45 cells stimulated with TNF-α, as assessed by RT-PCR. As determined using EMSA, a pretreatment with TUDCA reduced the TNF-α-induced NF-κB DNA binding activity. A pretreatment with TUDCA inhibited IκBα phosphorylation induced by TNF-α, as assessed by immunoblot analysis. TUDCA attenuated the ethanol-induced and NSAID-induced gastritis in murine models, as determined macroscopically and microscopically.
Conclusions
TUDCA inhibited NF-κB signaling in gastric epithelial cells and ameliorated ethanol- and NSAID-induced gastritis in murine models. These results support the potential of TUDCA for the prevention of gastritis in humans.
10.Prevalence of osteoporosis in patients with systemic lupus erythematosus: A multicenter comparative study of the World Health Organization and fracture risk assessment tool criteria
Ju-Yang JUNG ; Sang Tae CHOI ; Sung-Hoon PARK ; Seong-Ryul KWON ; Hyoun-Ah KIM ; Sung-Soo KIM ; Sang Hyon KIM ; Chang-Hee SUH
Osteoporosis and Sarcopenia 2020;6(4):173-178
Objectives:
Osteoporosis and fracture are known complications of systemic lupus erythematosus (SLE). We assessed the prevalence and risk factors for osteoporosis in patients with SLE.
Methods:
A total of 155 female SLE patients were recruited retrospectively in 5 university hospitals. The bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry, and the fracture risk assessment tool (FRAX) for high-risk osteoporotic fractures was calculated with and without BMD.
Results:
The mean age was 53.7 ± 6.8 years, and osteoporotic fractures were detected in 19/127 (15.0%) patients. The proportion of patients having a high-risk for osteoporotic fractures in the FRAX with and without BMD, and osteoporosis by the World Health Organization (WHO) criteria were 25 (16.1%), 24 (15.5%), and 51 (32.9%), respectively, and 48.0–68.6% of them were receiving treatment. On multivariate logistic analysis, nephritis (odds ratio [OR] 11.35) and cumulative dose of glucocorticoid (OR 1.1) were associated with high-risk by the FRAX with BMD, and low complement levels (OR 4.38), erythrocyte sedimentation rate (ESR) (OR 1.04), and cumulative dose of glucocorticoid (OR 1.05) were associated with osteoporosis by the WHO criteria in patients with SLE.
Conclusions
Among Korean female patients with SLE, the proportion of patients having a high-risk of osteoporotic fractures by the FRAX tool was 15.5%–16.1% and the proportion of patients having osteoporosis by the WHO criteria was 32.9%. In SLE, nephritis, low level of complement, ESR, and cumulative dose of glucocorticoids may contribute to fracture risk.