1.Incidence and Clinical Course of Post-infectious Irritable Bowel Syndrome in Patients Admitted to University Hospitals: 1-year Prospective Follow-up Study
Jae Gon LEE ; Sang Pyo LEE ; Hyun Joo JANG ; Sea Hyub KAE ; Woon Geon SHIN ; Seung In SEO ; Hyun LIM ; Ho Suk KANG ; Jae Seung SOH ; Chang Seok BANG ; Young Joo YANG ; Gwang Ho BAIK ; Jin Bae KIM ; Yu Jin KIM ; Chang Kyo OH ; Hallym Gastrointestinal Study Group
Journal of Neurogastroenterology and Motility 2025;31(1):110-118
Background/Aims:
Post-infectious irritable bowel syndrome (PI-IBS) is characterized by chronic gastrointestinal symptoms that arise following an episode of infectious enteritis. The incidence rates vary, ranging from 5% to 32% and the risk factors are not well known. We aim to investigate the incidence and risk factors of PI-IBS in enteritis patients admitted to university hospitals in Korea.
Methods:
This multi-center prospective study was conducted in patients hospitalized for infectious enteritis. Each patient underwent 1 outpatient visit and 3 telephone surveys during the first year after discharge to determine if PI-IBS occurred within the follow-up period.
Results:
In the 3-month survey, 7 out of 354 patients (2%) were diagnosed with PI-IBS, and after 1 year, only 1 patient met the criteria for IBS.No statistically significant difference was found between the PI-IBS group and the non-PI-IBS group in terms of age, sex, underlying diseases, medication history, gastrointestinal symptoms, enteritis location, causative strain, hospitalization and treatment periods, and laboratory findings. Female sex (P = 0.003), enteropathogenic Escherichia coli (EPEC) infection (P = 0.044), and a longer total treatment period (P = 0.018) were independent risk factors for diarrhea lasting ≥ 3 months after enteritis.
Conclusions
The incidence of PI-IBS in Korea was relatively low, and most cases improved over time. No risk factors associated with the development of PI-IBS were found. However, persistent diarrhea after enteritis was associated with female sex, EPEC infection, and severe or long-lasting enteritis. IBS symptoms may persist after severe enteritis but usually improve with time.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Comparing 1-L and 2-L Polyethylene Glycol with Ascorbic Acid for Small Bowel Capsule Endoscopy: A Randomized Controlled Trial
Chang Kyo OH ; Sang Pyo LEE ; Jae Gon LEE ; Young Joo YANG ; Seung In SEO ; Chang Seok BANG ; Yu Jin KIM ; Woon Geon SHIN ; Jin Bae KIM ; Hyun Joo JANG ; Sea Hyub KAE ; Gwang Ho BAIK ; Hallym Gastrointestinal Study Group
Gut and Liver 2025;19(1):87-94
Background/Aims:
Small bowel capsule endoscopy (SBCE) has become the standard for initial evaluation in the diagnosis of small bowel lesions. Although optimal visualization of the mucosa is important, patients experience difficulty in consuming a large volume of bowel preparation agents. This study aimed to compare the efficacy and safety of 1-L polyethylene glycol (PEG) with ascorbic acid (AA) and 2-L PEG with AA.
Methods:
In this prospective, multicenter, non-inferiority study, patients who received SBCE were randomly assigned to consume 1-L PEG with AA or 2-L PEG with AA for small bowel preparation. The primary outcome was adequate small bowel visibility quality (SBVQ). The secondary outcomes included diagnostic yield, cecal complete rate, and adverse events.
Results:
One hundred and forty patients were enrolled in this study, 70 patients per group. In the per-protocol analysis, there were no significant differences in the adequate SBVQ rate (94.0% vs 94.3%; risk difference, –0.3; 95% confidence interval, –8.1 to 7.6; p=1.000), diagnostic yield rate (49.3% vs 48.6%, p=0.936), or cecal complete rate (88.1% vs 92.9%, p=0.338) between the 1-L PEG with AA group and 2-L PEG with AA group. The incidence of adverse events did not differ significantly between the groups (12.9% vs 11.9%, p=0.871).
Conclusions
One liter-PEG with AA is not inferior to 2-L PEG with AA in terms of adequate SBVQ for SBCE. One liter-PEG with AA can be recommended as the standard method for bowel cleansing for SBCE.
4.Re-do laparoscopic common bile duct exploration for recurrent common bile duct stones: a single-center retrospective cohort study
In Ho LEE ; Seung Jae LEE ; Ju Ik MOON ; Sang Eok LEE ; Nak Song SUNG ; Seong Uk KWON ; In Eui BAE ; Seung Jae RHO ; Sung Gon KIM ; Min Kyu KIM ; Dae Sung YOON ; Won Jun CHOI ; In Seok CHOI
Annals of Surgical Treatment and Research 2025;108(5):310-316
Purpose:
Common bile duct (CBD) stone recurrence after laparoscopic CBD exploration (LCBDE) is relatively common. No studies have been conducted evaluating the safety and feasibility of re-do LCBDE in the treatment of recurrent CBD stones.
Methods:
This single-center retrospective study reviewed 340 consecutive patients who underwent LCBDE for CBD stones between January 2004 and December 2020. Patients with pancreatobiliary malignancies and those who underwent other surgical procedures were excluded.
Results:
Of the 340 included patients, 45 experienced a recurrence after a mean follow-up period of 24.2 months. Of them, 18 underwent re-do LCBDE, 20 underwent endoscopic intervention, 2 underwent radiologic intervention, and 5 underwent observation. Re-do LCBDE and initial LCBDE showed similar surgical outcomes in terms of operative time (113.1 minutes vs. 107.5 minutes, P = 0.515), estimated blood loss (42.5 mL vs. 49.1 mL, P = 0.661), open conversion rate (2.9% vs. 0%, P = 0.461), postoperative complication (15.3% vs. 22.2%, P = 0.430), and postoperative hospital stay (6.5 days vs. 6.4 days, P = 0.921). Comparing re-do LCBDE and nonsurgical treatment (endoscopic or radiologic), no statistically significant differences were noted in posttreatment complication (22.2% vs. 13.6%, P = 0.477), hospital stay (6.4 days vs.7.3 days, P = 0.607), and recurrence (50.0% vs. 36.4%, P = 0.385). The clearance rate was higher in the re-do LCBDE group than in the nonsurgical group (100% vs. 81.8%, P = 0.057).
Conclusion
Compared to initial LCBDE and endoscopic or radiological treatments, re-do LCBDE for recurrent CBD stones is a treatment option worth considering in selected patients.
5.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
6.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Impact of the National Early Warning Score-based sepsis response system on hospital-onset sepsis in a tertiary hospital in South Korea
Dong-gon HYUN ; Sohyeon LEE ; Sunhui CHOI ; Jeongsuk SON ; So-Hee PARK ; Sang-Bum HONG ; Chae-Man LIM
Acute and Critical Care 2025;40(2):186-196
Background:
The effectiveness of electronic medical record-based alert systems, response protocols for sepsis diagnosis, and treatment in hospitalized patients remains unclear. This study aimed to determine whether the introduction of an electronic medical record-based sepsis response protocol (SRP) along with a 24/7 operating rapid response system affects the prognosis for patients with hospital-onset sepsis.
Methods:
In August 2022, a SRP based on the National Early Warning Score was implemented in the electronic medical record system at Asan Medical Center. We retrospectively analyzed patients screened by the detection system for 1 year after the SRP implementation. Patients of the first 6 months (preliminary group) and those of the second 6 months (SRP group) were matched 1:1 based on propensity scores. The primary outcome was 30-day mortality.
Results:
Of the 608 hospitalized patients screened by the system, 176 were assigned to each group after 1:1 propensity score matching. Patients in the SRP group were significantly more likely to receive blood cultures (58.5%) compared with the preliminary group (45.5%) (P=0.019). The SRP group showed a lower 30-day mortality risk (hazard ratio, 0.56; 95% CI, 0.36–0.86; P=0.017) compared to the preliminary group. A restricted cubic spline curve showed that SRP survival benefit began to manifest after the first 4 months (P=0.036).
Conclusions
Alongside an existing rapid response system, the National Early Warning Score-based SRP in the electronic medical record reduced mortality for hospital-onset sepsis within 1 year.
9.Development and Validation of a Novel Isotope Dilution-Ultraperformance Liquid ChromatographyTandem Mass Spectrometry Method for Serum C-Peptide
Sung-Eun CHO ; Jungsun HAN ; Juyoung YOU ; Jun Hyung LEE ; Ahram YI ; Sang Gon LEE ; Eun Hee LEE
Annals of Laboratory Medicine 2025;45(1):62-69
Background:
Mass spectrometry (MS) methods exhibit higher accuracy and comparability in measuring serum C-peptide concentrations than immunoassays. We developed and validated a novel isotope dilution-ultraperformance liquid chromatography-tandem MS (IDUPLC-MS/MS) assay to measure serum C-peptide concentrations.
Methods:
Sample pretreatment involved solid-phase extraction, ion-exchange solid-phase extraction, and derivatization with 6-aminoquinolyl-N-hydroxysuccinimidylcarbamate (Cayman Chemical, Ann Arbor, Michigan, USA). We used an ExionLC UPLC system (Sciex, Framingham, MA, USA) and a Sciex Triple Quad 6500 + MS/MS system (Sciex) for electrospray ionization in positive-ion mode with multiple charge states of [M+3H]3+ and multiple reaction monitoring transitions. The total run time was 50 mins, and the flow rate was 0.20 mL/min. We evaluated the precision, trueness, linearity, lower limit of quantitation (LLOQ), carryover, and matrix effects. Method comparison with electrochemiluminescence immunoassay (ECLIA) was performed in 138 clinical specimens.
Results:
The intra- and inter-run precision coefficients of variation were < 5% and the bias values for trueness were < 4%, which were all acceptable. The verified linear interval was 0.050–15 ng/mL, and the LLOQ was 0.050 ng/mL. No significant carryover or matrix effects were observed. The correlation between this ID-UPLC-MS/MS method and ECLIA was good (R = 0.995, slope = 1.564); however, the ECLIA showed a positive bias (51.8%).
Conclusions
The developed ID-UPLC-MS/MS assay shows acceptable performance in measuring serum C-peptide concentrations. This will be useful in situations requiring accurate measurement of serum C-peptide in clinical laboratories.
10.Pancreatic Cancer Detection and Differentiation from Chronic Pancreatitis: Potential Biomarkers Identified Through a High-throughput Multiplex Proteomic Assay and Machine Learning-based Analysis
Young-gon KIM ; Sang-Mi KIM ; Soo-Youn LEE
Annals of Laboratory Medicine 2025;45(4):399-409
Background:
Pancreatic cancer (PC)-screening methods have limited accuracy despite their high clinical demand. Differential diagnosis of chronic pancreatitis (CP) poses another challenge for PC diagnosis. Therefore, we aimed to identify blood protein biomarkers for PC diagnosis and differential diagnosis of CP using high-throughput multiplex proteomic analysis.
Methods:
Two independent cohorts (N = 88 and 80) were included, and residual serum samples were collected from all individuals (N = 168). Each cohort consisted of four groups: healthy (H) individuals and those with CP, stage I/II PC (PC1), or stage III/IV PC (PC2). Protein expression in the first cohort was quantified using the Olink Immuno-Oncology and Oncology 3 proximity extension assay (PEA) panels and was analyzed using machine-learning (ML)-based analyses. Samples in the second cohort were utilized to verify candidate biomarkers in immunoassays.
Results:
Both the PEA and immunoassay results confirmed that previously recognized biomarkers, such as the mucin-16 and interleukin-6 proteins, were more highly expressed in the PC (PC1 and PC2) groups than in the non-PC (CP and H) groups. Several novel biomarkers for PC diagnosis were identified via ML-based feature extraction, including C1QA and CDHR2, whereas pro-neuropeptide Y (NPY) appeared to be a promising biomarker for the differential diagnosis of CP. Applying XGBoost classification incorporating the selected features resulted in an area under the curve of 0.92 (0.85–0.98) for differentiating the PC group from the CP and H groups.
Conclusions
Promising blood biomarkers for PC diagnosis and differential diagnosis of CP were identified using a PEA platform and ML techniques.

Result Analysis
Print
Save
E-mail