1.Emphysematous pyelonephritis in a nonfunctional graft kidney:a case for early nephrectomy?
Yeshwanth Mohan YELAVARTHY ; Anish Kumar SAHA ; Vinay RATHORE ; Jyoti AGGARWAL ; Shubham MAJUMDAR ; Amit SHARMA ; Sunil Kumar BEHERA ; Sandeep DESAI ; Rahul BHATIA
Clinical Transplantation and Research 2026;40(1):158-161
Emphysematous pyelonephritis (EPN) is a severe necrotizing kidney infection characterized by gas formation. While EPN is recognized in native kidneys and occasionally in functional renal allografts, its occurrence in nonfunctional allografts is extremely rare.We present a case of EPN in a 38-year-old female with a history of renal transplantation who developed EPN in a nonfunctional graft 1 year after returning to hemodialysis.The patient initially demonstrated excellent graft function posttransplant but later developed chronic antibody-mediated rejection and calcineurin inhibitor toxicity, which led to graft failure and resumption of hemodialysis. One year later, she presented with fever and graft site tenderness. Imaging revealed stage 3 EPN in the allograft. Empirical broad-spectrum antibiotics and percutaneous drainage were initiated, followed by graft nephrectomy due to persistent fever spikes. This case highlights the occurrence of EPN in a nonfunctional graft, even after cessation of immunosuppression. The presence of a nonfunctioning graft with impaired blood supply may have provided a nidus for infection. It underscores the importance of considering nephrectomy as a primary therapeutic approach in such cases. This case also emphasizes the need for heightened clinical suspicion and prompt intervention in transplant recipients with suspected EPN, even in the absence of a functioning graft.
2.Oxidative stress and inflammation in the pathogenesis of neurological disorders: Mechanisms and implications.
Umesh Chandra DASH ; Nitish Kumar BHOL ; Sandeep Kumar SWAIN ; Rashmi Rekha SAMAL ; Prabhat Kumar NAYAK ; Vishakha RAINA ; Sandeep Kumar PANDA ; Rout George KERRY ; Asim K DUTTAROY ; Atala Bihari JENA
Acta Pharmaceutica Sinica B 2025;15(1):15-34
Neuroprotection is a proactive approach to safeguarding the nervous system, including the brain, spinal cord, and peripheral nerves, by preventing or limiting damage to nerve cells and other components. It primarily defends the central nervous system against injury from acute and progressive neurodegenerative disorders. Oxidative stress, an imbalance between the body's natural defense mechanisms and the generation of reactive oxygen species, is crucial in developing neurological disorders. Due to its high metabolic rate and oxygen consumption, the brain is particularly vulnerable to oxidative stress. Excessive ROS damages the essential biomolecules, leading to cellular malfunction and neurodegeneration. Several neurological disorders, including Alzheimer's, Parkinson's, Amyotrophic lateral sclerosis, multiple sclerosis, and ischemic stroke, are associated with oxidative stress. Understanding the impact of oxidative stress in these conditions is crucial for developing new treatment methods. Researchers are exploring using antioxidants and other molecules to mitigate oxidative stress, aiming to prevent or slow down the progression of brain diseases. By understanding the intricate interplay between oxidative stress and neurological disorders, scientists hope to pave the way for innovative therapeutic and preventive approaches, ultimately improving individuals' living standards.
3.Use of combined spinal epidural technique with milrinone nebulization in a patient with pulmonary stenosis posted for elective cesarean section - A case report -
Gade SANDEEP ; Subrata Kumar SINGHA ; Sarita RAMCHANDANI ; Sai MAHITHA ; Swati VIJAPURKAR
Anesthesia and Pain Medicine 2025;20(3):242-245
Background:
Anesthetic management in pregnant women with congenital heart disease is complex due to physiological changes during pregnancy and the specific hemodynamic challenges posed by different cardiac anomalies. A multidisciplinary approach is essential to optimize maternal and fetal outcomes. Pregnancy induces significant cardiovascular changes to meet the increased metabolic demands of the mother and growing fetus. Cardiovascular changes may aggravate the underlying pathology during pregnancy, leading to hemodynamic instability.Case: A 27-year-old pregnant woman presented with severe pulmonary stenosis after pulmonary valve balloon dilatation for an elective cesarean section using a combined spinal-epidural technique (CSE) and milrinone nebulization to avoid right ventricular dysfunction.
Conclusions
CSE reduces the stress response to surgery, minimizes myocardial depression associated with anesthetic drugs, and improves postoperative pain control. Techniques such as milrinone nebulization may help lessen the hemodynamic perturbations associated with auto-transfusion post-delivery.
4.Similar Outcomes between Monoblock and Modular Femoral Stems in Total Hip Arthroplasty with Shortening Osteotomy for Dysplastic Hips at Five Years: A Systematic Review with Meta-analysis
Alok RAI ; Sandeep Kumar NEMA ; Arkesh MADEGOWDA ; Dushyant CHOUHAN ; Ankit Kumar GARG
Hip & Pelvis 2025;37(1):1-16
We aimed to examine the outcomes of arthritic congenital dislocation of hip in adults after subtrochanteric shortening derotation osteotomy (SSDO) with cementless hip arthroplasty at a minimum follow-up period of five years. Bibliographic databases were searched and isolated studies were divided into three groups (1, 2, and 3) based on the femoral stem type (modular, monoblock, or mixed). We pooled 931 hips/737 patients from 20 studies. The mean difference in the Harris hip score (HHS) before and after the operation was 47.55 (95% confidence interval [CI] 43.16, 51.94). On subgroup analysis the mean differences of 46.59 (95% CI 41.67, 51.51), 48.24 (95% CI 41.37, 55.11), and 47.30 (95% CI 43.85, 50.75), respectively in HHS were noted in groups 1, 2, and 3. The incidence of uncontrolled proximal femur fractures was comparable at 7.9% and 4.2% in groups 1 and 2; however, it was 0% and 16.6% for controlled fractures. The incidences of nonunion, dislocation, nerve paralysis, heterotopic ossification and revision due to any cause were 0.3%, 6.5%, 1.7%, 2.1%, and 7.9% for group 1 and 1.9%, 4.3%, 1.6%, 5.6%, and 7.4% for group 2. Similar improvements in functional outcome for both monoblock and modular stems can be expected. An increased incidence of controlled proximal femur fractures was observed with use of modular stems. The nonunion at the SSDO site was sporadic.
5.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
6.Modified Transiliac Plating Technique for Complex Posterior Pelvic Ring Injuries
Abhay ELHENCE ; Sandeep Kumar YADAV ; Jeshwanth NETAJI
Hip & Pelvis 2025;37(1):79-84
Pelvic ring injuries with rotational and translational instability are complex and often result from high-energy trauma, posing significant challenges in management. Internal fixation has emerged as the preferred approach, with traditional methods such as iliosacral screw fixation exhibiting drawbacks like implant-related morbidity and hardware complications. This paper presents a modified minimally invasive transiliac plating technique aimed at addressing these challenges. The surgical technique involves careful preoperative planning, precise patient positioning, and meticulous exposure of the posterior pelvic structures. Key steps include osteotomy of the posterior superior iliac spine (PSIS), formation of a subcutaneous tunnel, contouring and placement of the plate, and fixation with strategically positioned screws. Additionally, the modified technique incorporates the replacement of the osteotomized PSIS bony fragment, providing secondary stability and minimizing the risk of implant back out. This modification aims to enhance biomechanical stability, reduce implant-related morbidity, and ensure optimal functional outcomes. The technique’s efficacy is supported by biomechanical principles and clinical studies, indicating its potential as a promising alternative in the management of unstable pelvic ring injuries. Overall, this modified approach offers improved patient comfort, reduced surgical risks, and enhanced long-term outcomes, contributing to advancements in pelvic ring fracture management.
7.Posterior-only fixation in pelvic fractures: Is it sufficient in lateral compression injuries?
Sameer AGGARWAL ; Sandeep PATEL ; Lav MEHTA ; Mohak KATARIA ; Vishal KUMAR ; Prasoon KUMAR
Chinese Journal of Traumatology 2025;28(3):226-230
PURPOSE:
Lateral compression (LC) injuries account for more than two-thirds of all pelvic fractures. The goal of surgical treatment is to provide adequate stability and early mobilization. The consensus on posterior fixation of such injuries is strong in the literature; however, the necessity of anterior ring fixation is not clear. Therefore, this study was formulated to determine the practicability of posterior-only fixation in LC injuries.
METHODS:
Between March 2015 and May 2020, all patients with LC type pelvic ring fractures who were admitted and operated upon in a single level 1 trauma center were included in this cross-sectional observational study. Demographic data, co-morbidities, treatment, types of surgical fixation, concomitant injuries and surgeries, surgical complications, length of hospital stay, injury to weight bearing duration, and follow-up period were documented. Functional outcome and quality of life were assessed using Majeed score and SF-36 questionnaire. Non-normally distributed data were presented as median (Q1, Q3) and normally distributed data were presented as mean ± standard deviation (SD). Spearman's rank correlation coefficient was used for correlation analysis.
RESULTS:
A total of 25 patients were included, with a mean age of 29.8 years. All patients were managed operatively with posterior-only fixation. The median Majeed score was 90 (76, 95). The median physical component summary score was 69.37 (38.75, 85.62). The median mental component summary score was 63.95 (39.25, 87.87). There was no significant difference compared to population norms of both physical component summary and mental component summary. Injury to weight bearing time correlated significantly (p = 0.002) with Majeed score as well as SF-36 score (p = 0.044). No other variable had a significant association with outcomes.
CONCLUSION
Posterior-only fixation is sufficient for fixing LC injuries with up to 80% of cases having good to excellent functional outcomes. However, comparative studies with larger sample sizes are needed for further validation.
Humans
;
Male
;
Female
;
Adult
;
Cross-Sectional Studies
;
Pelvic Bones/surgery*
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
;
Middle Aged
;
Young Adult
;
Quality of Life
;
Adolescent
;
Length of Stay
8.Similar Outcomes between Monoblock and Modular Femoral Stems in Total Hip Arthroplasty with Shortening Osteotomy for Dysplastic Hips at Five Years: A Systematic Review with Meta-analysis
Alok RAI ; Sandeep Kumar NEMA ; Arkesh MADEGOWDA ; Dushyant CHOUHAN ; Ankit Kumar GARG
Hip & Pelvis 2025;37(1):1-16
We aimed to examine the outcomes of arthritic congenital dislocation of hip in adults after subtrochanteric shortening derotation osteotomy (SSDO) with cementless hip arthroplasty at a minimum follow-up period of five years. Bibliographic databases were searched and isolated studies were divided into three groups (1, 2, and 3) based on the femoral stem type (modular, monoblock, or mixed). We pooled 931 hips/737 patients from 20 studies. The mean difference in the Harris hip score (HHS) before and after the operation was 47.55 (95% confidence interval [CI] 43.16, 51.94). On subgroup analysis the mean differences of 46.59 (95% CI 41.67, 51.51), 48.24 (95% CI 41.37, 55.11), and 47.30 (95% CI 43.85, 50.75), respectively in HHS were noted in groups 1, 2, and 3. The incidence of uncontrolled proximal femur fractures was comparable at 7.9% and 4.2% in groups 1 and 2; however, it was 0% and 16.6% for controlled fractures. The incidences of nonunion, dislocation, nerve paralysis, heterotopic ossification and revision due to any cause were 0.3%, 6.5%, 1.7%, 2.1%, and 7.9% for group 1 and 1.9%, 4.3%, 1.6%, 5.6%, and 7.4% for group 2. Similar improvements in functional outcome for both monoblock and modular stems can be expected. An increased incidence of controlled proximal femur fractures was observed with use of modular stems. The nonunion at the SSDO site was sporadic.
9.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
10.Modified Transiliac Plating Technique for Complex Posterior Pelvic Ring Injuries
Abhay ELHENCE ; Sandeep Kumar YADAV ; Jeshwanth NETAJI
Hip & Pelvis 2025;37(1):79-84
Pelvic ring injuries with rotational and translational instability are complex and often result from high-energy trauma, posing significant challenges in management. Internal fixation has emerged as the preferred approach, with traditional methods such as iliosacral screw fixation exhibiting drawbacks like implant-related morbidity and hardware complications. This paper presents a modified minimally invasive transiliac plating technique aimed at addressing these challenges. The surgical technique involves careful preoperative planning, precise patient positioning, and meticulous exposure of the posterior pelvic structures. Key steps include osteotomy of the posterior superior iliac spine (PSIS), formation of a subcutaneous tunnel, contouring and placement of the plate, and fixation with strategically positioned screws. Additionally, the modified technique incorporates the replacement of the osteotomized PSIS bony fragment, providing secondary stability and minimizing the risk of implant back out. This modification aims to enhance biomechanical stability, reduce implant-related morbidity, and ensure optimal functional outcomes. The technique’s efficacy is supported by biomechanical principles and clinical studies, indicating its potential as a promising alternative in the management of unstable pelvic ring injuries. Overall, this modified approach offers improved patient comfort, reduced surgical risks, and enhanced long-term outcomes, contributing to advancements in pelvic ring fracture management.

Result Analysis
Print
Save
E-mail