1.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
2.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
3.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
4.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
5.Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Ki-Han YOU ; Samuel K. CHO ; Jae-Yeun HWANG ; Sun-Ho CHA ; Min-Seok KANG ; Sang-Min PARK ; Hyun-Jin PARK
Neurospine 2024;21(3):973-983
Objective:
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods:
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results:
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
6.Transient postoperative inferior subluxation of the shoulder after surgical stabilization of recurrent anterior dislocation in a patient with myasthenia gravis: a case report
Samuel BAEK ; Geum-Ho LEE ; Myung Ho SHIN ; Tae Min KIM ; Kyung-Soo OH ; Seok Won CHUNG
Clinics in Shoulder and Elbow 2023;26(3):302-305
The authors present a case of transient postoperative inferior subluxation of the shoulder after arthroscopic surgical stabilization for recurrent anterior dislocation. The patient was a 61-year-old woman with myasthenia gravis (MG). The first anterior shoulder dislocation occurred because of a fall to the ground. Despite a successful closed reduction, two more dislocations occurred in 3 weeks. Magnetic resonance imaging revealed an anterior labroligamentous periosteal sleeve avulsion (ALPSA) lesion, an engaging Hill-Sachs lesion, and large tears of the supraspinatus and infraspinatus tendons. The patient underwent arthroscopic rotator cuff repair and ALPSA repair with a remplissage procedure. Intraoperatively, no tendency for instability was found; however, a widened glenohumeral joint space and inferior subluxation of the humeral head without functional compromise was observed on the day after surgery and disappeared spontaneously on radiographs 2 weeks later. To the authors’ knowledge, this is the first report documenting the occurrence of transient postoperative inferior subluxation of the shoulder in a patient with MG.
7.Can a Two Simple Stitches Method Provide Secure Fixation Strength in Biceps Tenodesis?:Biomechanical Evaluation of Various Suture Techniques
Tae Min KIM ; Myung Ho SHIN ; Samuel BAEK ; Dong Ryun LEE ; Seok Won CHUNG
Clinics in Orthopedic Surgery 2022;14(3):426-433
Background:
The purpose of this study was to compare the initial fixation strength between four different suture methods for the long head of the biceps.
Methods:
Forty-eight fresh frozen porcine flexor hallucis longus tendons (mean width at suture site, 8.5 ± 0.9 mm) and phalanx bones were randomly assigned to one of the four arthroscopic biceps tenodesis techniques: simple stitch (SS), mattress suture (MS), lasso-loop (LL), and two simple stitches (2SS). A biceps tenodesis was performed according to the four techniques using all-suture type suture anchors (1.9-mm SUTUREFIX anchor with No. 1 ULTRABRAID sutures). Biomechanical evaluations were performed to test load to failure (N), stiffness (N/mm), stress (N/m 2 ), and mode of failure.
Results:
As for the SS, MS, LL, and 2SS, the mean load to failure was 50.9 ± 14.61 N, 82.3 ± 24.8 N, 116.2 ± 26.7 N, and 130.8 ± 22.5 N (p < 0.001), respectively; mean stiffness was 6.1 ± 1.3 N/mm, 6.7 ± 2.6 N/mm, 7.8 ± 1.4 N/mm, and 8.1 ± 4.2 N/mm, respectively (p = 0.258); and mean stress was 0.7 ± 0.3 N/m 2 , 1.4 ± 0.8 N/m 2 , 2.9 ± 0.7 N/m 2 , and 2.7 ± 0.8 N/m 2 , respectively (p < 0.001). All the failures happened by the suture cutting through the tendon along its longitudinal fibers.
Conclusions
Neither the SS nor the MS method was enough to securely fix the biceps tendon with a significantly lower mechanical strength; however, the 2SS method showed similar initial fixation strength as the LL technique.
8.Causes, functional outcomes and healthcare utilisation of people with cerebral palsy in Singapore.
Zhi Min NG ; Jeremy B LIN ; Poh Choo KHOO ; Victor Samuel RAJADURAI ; Derrick W S CHAN ; Hian Tat ONG ; Janice WONG ; Chew Thye CHOONG ; Kim Whee LIM ; Kevin B L LIM ; Tong Hong YEO
Annals of the Academy of Medicine, Singapore 2021;50(2):111-118
INTRODUCTION:
A voluntary cerebral palsy (CP) registry was established in 2017 to describe the clinical characteristics and functional outcomes of CP in Singapore.
METHODS:
People with CP born after 1994 were recruited through KK Women's and Children's Hospital, National University Hospital and Cerebral Palsy Alliance Singapore. Patient-reported basic demographics, service utilisation and quality of life measures were collected with standardised questionnaires. Clinical information was obtained through hospital medical records.
RESULTS:
Between 1 September 2017 and 31 March 2020, 151 participants were recruited. A majority (n=135, 89%) acquired CP in the pre/perinatal period, where prematurity (n=102, 76%) and the need for emergency caesarean section (n=68, 50%) were leading risk factors. Sixteen (11%) of the total participants had post-neonatally acquired CP. For predominant CP motor types, 109 (72%) had a spastic motor type; 32% with spastic mono/hemiplegia, 41% diplegia, 6% triplegia and 21% quadriplegia. The remaining (42, 27.8%) had dyskinetic CP. Sixty-eight (45.0%) participants suffered significant functional impairment (Gross Motor Functional Classification System levels IV-V). Most participants (n=102, 67.5%) required frequent medical follow-up (≥4 times a year).
CONCLUSION
Optimisation of pre- and perinatal care to prevent and manage prematurity could reduce the burden of CP and their overall healthcare utilisation.
9.Metastasis of renal cell carcinoma around suture anchor implants
Samuel BAEK ; Myung Ho SHIN ; Tae Min KIM ; Kyung-Soo OH ; Dong Ryun LEE ; Seok Won CHUNG
Clinics in Shoulder and Elbow 2021;24(2):110-113
We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.
10.Incidence and management of mandibular fractures in a low-resource health facility in Ghana
Paul FRIMPONG ; Truc Thi Hoang NGUYEN ; Buyanbileg SODNOM-ISH ; Edinam Salia NIMATU ; Nana Yaa Asantewaa DAMPARE ; Roberta ROCKSON ; Samuel Baffour AWUAH ; Emmanuel Kofi AMPONSAH ; Cardinal NEWTON ; Soung Min KIM
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2021;47(6):432-437
Objectives:
The mandible and other parts of the maxillofacial region suffer significant morbid injuries following road traffic accidents. Our studygives epidemiological description of mandibular fractures in Ghana and also evaluates the relevance of closed reduction and indirect fixation for managing mandibular fractures in low-resource health facilities in low-income countries like Ghana.
Patients and Methods:
This is a retrospective study involving 268 patients who reported to the Department of Oral and Maxillofacial Surgery of the Sunyani Regional Hospital with mandibular fractures from January 2010 to December 2019. Patient medical records were assessed for information on age, sex, fracture etiology, anatomic location of fracture, time of day of road traffic accident, and other associated injuries.
Results:
A total of 268 patients were included in this study (males, 216 [80.6%]; females, 52 [19.4%]). Motor vehicular accident (MVA) was the lead-ing cause of mandibular fractures (202 injuries, 75.4%). Other etiologies included assault (39, 14.6%), gunshot (13, 4.9%), falls (12, 4.5%), and indus-trial accidents (2, 0.7%). Of the 161 male cases caused by MVA, 121 (75.2%) occurred at night and in the evening while the remaining 40 (24.8%) oc-curred in the morning and afternoon. Among all managed 222 patients, 212 (79.1%) were treated with closed reduction and indirect fixation technique while 10 (3.7%) were treated with open reduction and direct fixation.
Conclusion
Closed reduction with indirect fixation could successfully be used to manage mandibular fractures in low resourced health facilities, es-pecially in low-income countries. The poor lightening system on roads in Ghana is a major contributory factor to motor vehicular accidents.

Result Analysis
Print
Save
E-mail