1.Dehydrocostus lactone ameliorates renal interstitial fibrosis in rats with unilateral ureteral obstruction by inhibiting the TGF-β1/Smad2/3 pathway
Zhongda LI ; Shuhong WANG ; Hongwei TAN ; Xiao WANG ; Jinyang ZHUANG ; Sheng SHEN ; Qipeng SUN
Organ Transplantation 2025;16(5):763-770
Objective To explore the action mechanism of dehydrocostus lactone(DHL)on renal interstitial fibrosis(RIF)in rats with unilateral ureteral obstruction(UUO).Methods Forty-four male SD rats were randomly divided into four groups:the sham surgery group(Sham group),the pure drug intervention group(Sham+DHL group),the experimental group(UUO+Vehicle group)and the DHL treatment group(UUO+DHL group),with 11 rats in each group.The rats underwent sham surgery,sham surgery+DHL[10 mg/(kg·d)],UUO modeling+the same volume of solvent and UUO modeling+DHL[10 mg/(kg·d)],respectively.After surgery,DHL or the same volume of solvent was administered by gavage for 14 days starting from day 2 post-surgery.Hematoxylin-eosin(HE)and Masson staining were used to observe the pathological changes in renal tissue.Immunohistochemical staining was performed to detect the expression levels of collagen I,collagen III and α-smooth muscle actin(α-SMA).Western blotting was used to detect the protein levels of the transforming growth factor(TGF)-β1/Smad2/3 pathway.Results Compared with the UUO+Vehicle group,DHL treatment alleviated renal interstitial pathological damage,reduced collagen fiber deposition,and decreased the expression of collagen I,collagen III and α-SMA.It also inhibited the expression of TGF-β1 and Smad2/3 proteins.Conclusions DHL mitigates RIF in rats by inhibiting the TGF-β1/Smad2/3 pathway,providing a new strategy for the treatment of chronic kidney disease.
2.Dehydrocostus lactone ameliorates renal interstitial fibrosis in rats with unilateral ureteral obstruction by inhibiting the TGF-β1/Smad2/3 pathway
Zhongda LI ; Shuhong WANG ; Hongwei TAN ; Xiao WANG ; Jinyang ZHUANG ; Sheng SHEN ; Qipeng SUN
Organ Transplantation 2025;16(5):763-770
Objective To explore the action mechanism of dehydrocostus lactone(DHL)on renal interstitial fibrosis(RIF)in rats with unilateral ureteral obstruction(UUO).Methods Forty-four male SD rats were randomly divided into four groups:the sham surgery group(Sham group),the pure drug intervention group(Sham+DHL group),the experimental group(UUO+Vehicle group)and the DHL treatment group(UUO+DHL group),with 11 rats in each group.The rats underwent sham surgery,sham surgery+DHL[10 mg/(kg·d)],UUO modeling+the same volume of solvent and UUO modeling+DHL[10 mg/(kg·d)],respectively.After surgery,DHL or the same volume of solvent was administered by gavage for 14 days starting from day 2 post-surgery.Hematoxylin-eosin(HE)and Masson staining were used to observe the pathological changes in renal tissue.Immunohistochemical staining was performed to detect the expression levels of collagen I,collagen III and α-smooth muscle actin(α-SMA).Western blotting was used to detect the protein levels of the transforming growth factor(TGF)-β1/Smad2/3 pathway.Results Compared with the UUO+Vehicle group,DHL treatment alleviated renal interstitial pathological damage,reduced collagen fiber deposition,and decreased the expression of collagen I,collagen III and α-SMA.It also inhibited the expression of TGF-β1 and Smad2/3 proteins.Conclusions DHL mitigates RIF in rats by inhibiting the TGF-β1/Smad2/3 pathway,providing a new strategy for the treatment of chronic kidney disease.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Multiomics profiling reveals VDR as a central regulator of mesenchymal stem cell senescence with a known association with osteoporosis after high-fat diet exposure
Chen JIAYAO ; Kuang SHUHONG ; Cen JIETAO ; Zhang YONG ; Shen ZONGSHAN ; Qin WEI ; Huang QITING ; Wang ZIFENG ; Gao XIANLING ; Huang FANG ; Lin ZHENGMEI
International Journal of Oral Science 2024;16(4):695-710
The consumption of a high-fat diet(HFD)has been linked to osteoporosis and an increased risk of fragility fractures.However,the specific mechanisms of HFD-induced osteoporosis are not fully understood.Our study shows that exposure to an HFD induces premature senescence in bone marrow mesenchymal stem cells(BMSCs),diminishing their proliferation and osteogenic capability,and thereby contributes to osteoporosis.Transcriptomic and chromatin accessibility analyses revealed the decreased chromatin accessibility of vitamin D receptor(VDR)-binding sequences and decreased VDR signaling in BMSCs from HFD-fed mice,suggesting that VDR is a key regulator of BMSC senescence.Notably,the administration of a VDR activator to HFD-fed mice rescued BMSC senescence and significantly improved osteogenesis,bone mass,and other bone parameters.Mechanistically,VDR activation reduced BMSC senescence by decreasing intracellular reactive oxygen species(ROS)levels and preserving mitochondrial function.Our findings not only elucidate the mechanisms by which an HFD induces BMSC senescence and associated osteoporosis but also offer new insights into treating HFD-induced osteoporosis by targeting the VDR-superoxide dismutase 2(SOD2)-ROS axis.
8.Multiomics profiling reveals VDR as a central regulator of mesenchymal stem cell senescence with a known association with osteoporosis after high-fat diet exposure
Chen JIAYAO ; Kuang SHUHONG ; Cen JIETAO ; Zhang YONG ; Shen ZONGSHAN ; Qin WEI ; Huang QITING ; Wang ZIFENG ; Gao XIANLING ; Huang FANG ; Lin ZHENGMEI
International Journal of Oral Science 2024;16(4):695-710
The consumption of a high-fat diet(HFD)has been linked to osteoporosis and an increased risk of fragility fractures.However,the specific mechanisms of HFD-induced osteoporosis are not fully understood.Our study shows that exposure to an HFD induces premature senescence in bone marrow mesenchymal stem cells(BMSCs),diminishing their proliferation and osteogenic capability,and thereby contributes to osteoporosis.Transcriptomic and chromatin accessibility analyses revealed the decreased chromatin accessibility of vitamin D receptor(VDR)-binding sequences and decreased VDR signaling in BMSCs from HFD-fed mice,suggesting that VDR is a key regulator of BMSC senescence.Notably,the administration of a VDR activator to HFD-fed mice rescued BMSC senescence and significantly improved osteogenesis,bone mass,and other bone parameters.Mechanistically,VDR activation reduced BMSC senescence by decreasing intracellular reactive oxygen species(ROS)levels and preserving mitochondrial function.Our findings not only elucidate the mechanisms by which an HFD induces BMSC senescence and associated osteoporosis but also offer new insights into treating HFD-induced osteoporosis by targeting the VDR-superoxide dismutase 2(SOD2)-ROS axis.
9.Ultrasonic follow-up observation on size changes of 4C type thyroid micronodule classified by C-TIRADS
Guangxiang YANG ; Weihong SHEN ; Hong GUO ; Shuhong LIU ; Dan LIU
Chinese Journal of Health Management 2023;17(1):47-51
Objective:To observe the size changes under ultrasound of 4C type thyroid micronodules classified by 2020 Chinese Thyroid Imaging Reporting and Data System (C-TIRADS)during follow-up.Methods:In this cross-sectional study, the data of thyroid ultrasonography in physical examination center in the Affiliated Zhongshan Hospital of Dalian University between December 2017 and December 2021 were retrospectively included, thyroid nodules were classified according to C-TIRADS, to observe the changes by ultrasound of maximum diameter and volume of 4C type thyroid micronodules during follow-up.Results:A total of 102 subjects receiving physical examinations with 103 thyroid micronodules were enrolled in this study. The maximum diameter and volume of thyroid micronodules at initial examination was 5.0 (4.0, 7.0) mm and 52.5 (25.2, 113.4) mm 3 respectively, and it was 6.0 (4.0,7.0) mm、65.6 (25.2,147.0) mm 3 at the last examination, respectively. Of the thyroid micronodules, 79 (76.7%) remained stable, 14 (13.6%) magnified and 10 (9.7%) shrunk during the follow-up. The cervical lymph nodes in all physical examiners were normal. There were significant changes in the maximum diameter and volume in the thyroid micronodules between the initial and last examination in subjects whose micronodules shrunk or magnified during the follow-up (all P<0.05). Conclusion:Size of most C-TIRADS 4C thyroid micronodules remains stable or even decreases during ultrasound follow-up observation, for such thyroid nodules, follow-up observation appears to be a safe and feasible way to postpone surgery.
10.Venous thromboembolism in children with acute lymphoblastic leukemia in China: a report from the Chinese Children's Cancer Group-ALL-2015.
Mengmeng YIN ; Hongsheng WANG ; Xianmin GUAN ; Ju GAO ; Minghua YANG ; Ningling WANG ; Tianfeng LIU ; Jingyan TANG ; Alex W K LEUNG ; Fen ZHOU ; Xuedong WU ; Jie HUANG ; Hong LI ; Shaoyan HU ; Xin TIAN ; Hua JIANG ; Jiaoyang CAI ; Xiaowen ZHAI ; Shuhong SHEN ; Qun HU
Frontiers of Medicine 2023;17(3):518-526
Venous thromboembolism (VTE) is a complication in children with acute lymphoblastic leukemia (ALL). The Chinese Children's Cancer Group-ALL-2015 protocol was carried out in China, and epidemiology, clinical characteristics, and risk factors associated with VTE were analyzed. We collected data on VTE in a multi-institutional clinical study of 7640 patients with ALL diagnosed in 20 hospitals from January 2015 to December 2019. First, VTE occurred in 159 (2.08%) patients, including 90 (56.6%) during induction therapy and 108 (67.92%) in the upper extremities. T-ALL had a 1.74-fold increased risk of VTE (95% CI 1.08-2.8, P = 0.022). Septicemia, as an adverse event of ALL treatment, can significantly promote the occurrence of VTE (P < 0.001). Catheter-related thrombosis (CRT) accounted for 75.47% (n = 120); and, symptomatic VTE, 58.49% (n = 93), which was more common in patients aged 12-18 years (P = 0.023), non-CRT patients (P < 0.001), or patients with cerebral thrombosis (P < 0.001). Of the patients with VTE treated with anticoagulation therapy (n = 147), 4.08% (n = 6) had bleeding. The VTE recurrence rate was 5.03% (n = 8). Patients with VTE treated by non-ultrasound-guided venous cannulation (P = 0.02), with residual thrombus (P = 0.006), or with short anticoagulation period (P = 0.026) had high recurrence rates. Thus, preventing repeated venous puncture and appropriately prolonged anticoagulation time can reduce the risk of VTE recurrence.
Humans
;
Child
;
Venous Thromboembolism/etiology*
;
East Asian People
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/epidemiology*
;
Risk Factors
;
Thrombosis/chemically induced*
;
China/epidemiology*
;
Anticoagulants/adverse effects*
;
Recurrence

Result Analysis
Print
Save
E-mail