1.Efficacy and safety of high-power,short-duration radiofrequency catheter ablation for persistent atrial fibrillation
Guang-an LIU ; Wang-long WU ; Lin-xiao ZHOU ; Jing CUI ; Bo SHAO ; Ruo-xi ZHANG ; Feng LIU
Chinese Journal of Interventional Cardiology 2025;33(5):266-271
Objective To evaluate the efficacy and safety of high-power,short-duration radiofrequency catheter ablation for the treatment of persistent atrial fibrillation.Methods This retrospective study included 392 patients diagnosed with persistent atrial fibrillation who underwent catheter radiofrequency ablation at Suzhou Kowloon Hospital,Shanghai Jiao Tong University School of Medicine,from January 2019 to December 2023.Of these,256 patients were treated with high-power,short-duration ablation,and 136 patients with low-power,long-duration ablation.The following parameters were compared:radiofrequency ablation time,total procedure time,single-circle pulmonary vein isolation rate,immediate procedural success rate,number of ablation points,and perioperative complications(including pericardial tamponade,pseudoaneurysm,arteriovenous fistula,stroke,etc.).Follow-up assessments were conducted at 3,6,and 12 months post-surgery to evaluate the 12-month sinus rhythm maintenance rate.Results The ablation time in the high-power group was significantly shorter than that in the low-power group[(14.6±2.3)min vs.(30.3±4.2)min,P<0.001],as was the total procedure time[(113.8±24.8)min vs.(128.5±26.7)min,P=0.001].There were no significant differences between the two groups in terms of pulmonary vein isolation rate(97.7%vs.94.9%,P=0.823),number of ablation points[(71.2±8.0)vs.(74.3±14.3),P=0.168],or perioperative complications(3.1%vs.4.4%,P=0.571).Regarding the maintenance rate of sinus rhythm at 12 months post-operation,the high-power group showed a higher rate than the low-power group,but no statistically significant difference was observed(82.8%vs.79.4%,P=0.399).Conclusions High-power,short-duration radiofrequency catheter ablation can improve procedural efficiency in the treatment of persistent atrial fibrillation.Its efficacy and safety are similar to those of the low-power,long-duration technique.
2.Efficacy and safety of high-power,short-duration radiofrequency catheter ablation for persistent atrial fibrillation
Guang-an LIU ; Wang-long WU ; Lin-xiao ZHOU ; Jing CUI ; Bo SHAO ; Ruo-xi ZHANG ; Feng LIU
Chinese Journal of Interventional Cardiology 2025;33(5):266-271
Objective To evaluate the efficacy and safety of high-power,short-duration radiofrequency catheter ablation for the treatment of persistent atrial fibrillation.Methods This retrospective study included 392 patients diagnosed with persistent atrial fibrillation who underwent catheter radiofrequency ablation at Suzhou Kowloon Hospital,Shanghai Jiao Tong University School of Medicine,from January 2019 to December 2023.Of these,256 patients were treated with high-power,short-duration ablation,and 136 patients with low-power,long-duration ablation.The following parameters were compared:radiofrequency ablation time,total procedure time,single-circle pulmonary vein isolation rate,immediate procedural success rate,number of ablation points,and perioperative complications(including pericardial tamponade,pseudoaneurysm,arteriovenous fistula,stroke,etc.).Follow-up assessments were conducted at 3,6,and 12 months post-surgery to evaluate the 12-month sinus rhythm maintenance rate.Results The ablation time in the high-power group was significantly shorter than that in the low-power group[(14.6±2.3)min vs.(30.3±4.2)min,P<0.001],as was the total procedure time[(113.8±24.8)min vs.(128.5±26.7)min,P=0.001].There were no significant differences between the two groups in terms of pulmonary vein isolation rate(97.7%vs.94.9%,P=0.823),number of ablation points[(71.2±8.0)vs.(74.3±14.3),P=0.168],or perioperative complications(3.1%vs.4.4%,P=0.571).Regarding the maintenance rate of sinus rhythm at 12 months post-operation,the high-power group showed a higher rate than the low-power group,but no statistically significant difference was observed(82.8%vs.79.4%,P=0.399).Conclusions High-power,short-duration radiofrequency catheter ablation can improve procedural efficiency in the treatment of persistent atrial fibrillation.Its efficacy and safety are similar to those of the low-power,long-duration technique.
3.Analysis of epidemiological and clinical characteristics of 1247 cases of infectious diseases of the central nervous system
Jia-Hua ZHAO ; Yu-Ying CEN ; Xiao-Jiao XU ; Fei YANG ; Xing-Wen ZHANG ; Zhao DONG ; Ruo-Zhuo LIU ; De-Hui HUANG ; Rong-Tai CUI ; Xiang-Qing WANG ; Cheng-Lin TIAN ; Xu-Sheng HUANG ; Sheng-Yuan YU ; Jia-Tang ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(1):43-49
Objective To summarize the epidemiological and clinical features of infectious diseases of the central nervous system(CNS)by a single-center analysis.Methods A retrospective analysis was conducted on the data of 1247 cases of CNS infectious diseases diagnosed and treated in the First Medical Center of PLA General Hospital from 2001 to 2020.Results The data for this group of CNS infectious diseases by disease type in descending order of number of cases were viruses 743(59.6%),Mycobacterium tuberculosis 249(20.0%),other bacteria 150(12.0%),fungi 68(5.5%),parasites 18(1.4%),Treponema pallidum 18(1.4%)and rickettsia 1(0.1%).The number of cases increased by 177 cases(33.1%)in the latter 10 years compared to the previous 10 years(P<0.05).No significant difference in seasonal distribution pattern of data between disease types(P>0.05).Male to female ratio is 1.87︰1,mostly under 60 years of age.Viruses are more likely to infect students,most often at university/college level and above,farmers are overrepresented among bacteria and Mycobacterium tuberculosis,and more infections of Treponema pallidum in workers.CNS infectious diseases are characterized by fever,headache and signs of meningeal irritation,with the adductor nerve being the more commonly involved cranial nerve.Matagenomic next-generation sequencing improves clinical diagnostic capabilities.The median hospital days for CNS infectious diseases are 18.00(11.00,27.00)and median hospital costs are ¥29,500(¥16,000,¥59,200).The mortality rate from CNS infectious diseases is 1.6%.Conclusions The incidence of CNS infectious diseases is increasing last ten years,with complex clinical presentation,severe symptoms and poor prognosis.Early and accurate diagnosis and standardized clinical treatment can significantly reduce the morbidity and mortality rate and ease the burden of disease.
4.Discussion on the duration of needle retention.
Xin-Yun HUANG ; Jing LI ; Kan GU ; Hong XU ; Ruo-Lin CUI ; Wei-Jie YANG ; Jia-Wei YING ; Lei ZONG ; Ren ZHANG
Chinese Acupuncture & Moxibustion 2019;39(4):445-450
Needle retention is an important step in the acupuncture procedure. How to optimize scientifically the duration of needle retention according to individual case has been considered in the medical circle. In this paper, by collecting the literatures on needle retention from the early dynasty to the contemporary time, the evolution of the needle retention from a short duration to a long one with the productivity improvement was elaborated. On the base of the views of the medical scholars of all dynasties, it was concluded that the ultimate purpose of needle retention is to improve the effects of acupuncture on the premise of ensuring the safety of acupuncture. Hence, the clinical physician should optimize the duration of needle retention cautiously in compliance with the tolerance of patient so as to save the time cost of both physician and patient, avoid the occurrence of tolerable effect of acupuncture and reduce the potential safety hazard of acupuncture induced by the long duration of needle retention.
Acupuncture Therapy
;
Humans
;
Moxibustion
;
Needles
;
Physicians
;
Time Factors

Result Analysis
Print
Save
E-mail