1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
4.Clinicopathologic characteristics, imaging features and prognosis analysis of hepatic epithelioid hemangioendothelioma
Xiaopeng WANG ; Peijie LYU ; Rui LI ; Ping HOU ; Xiaoxue LIANG ; Jianbo GAO
Chinese Journal of Hepatobiliary Surgery 2025;31(3):214-218
Objective:Analyze the clinicopatholocical and imaging characteristics of hepatic epithelioid hemangioendothelioma (HEHE) and the related factors of survival prognosis.Methods:Clinical data of 32 patients diagnosed with HEHE at the First Affiliated Hospital of Zhengzhou University from January 2013 to December 2023 retrospectively analyzed, including 11 males and 21 females, aged (46.8±3.6) years. The clinical manifestations, pathological findings, CT and MRI features of the patients were analyzed and the living conditions of the patients were followed up. Kaplan-Meier method was used for survival analysis, and log-rank test was used for survival rate comparison.Results:Among the 32 patients, 17 (53.1%) had no obvious symptoms, 10 (31.3%) had abdominal pain, 6 (18.8%) had abdominal distension, and 4 (12.5%) had lost weight. Under the microscope, HEHE was composed of mucous matrix and epithelioid endothelial cells, with dense surrounding cells and relatively sparse center. Small blood vessels can be seen invading the junction with normal liver tissue. The positive rates of endothelial marker CD34 in immunohistochemically staining was 100%(32/32), the positive rates of CD31 were 100% (32/32). The positive rates of erythroblast transformation specific related gene were 100% (28/28), and the positive rates of Friend leukemia virus integration protein 1 (22/22) were 100%. CT and MRI scan showed that the lesion were mainly multiple nodules and in diffuse formality. In arterial phase, the lesion showed slight homogeneous or ring-like enhancement, while in portal phase, the lesion showed progressive enhancement. Some lesions may exhibit more specific "lollipop sign" ( n=9) and "target ring sign" ( n=15). The median overall survival time of the 32 patients was 47 months, and the cumulative 1-, 3-, and 5-year survival were 100%, 95.0% and 72.7%, respectively. The cumulative survival rate of patients with "target ring sign" ( n=15), extrahepatic organ involvement or metastasis ( n=8) and Ki-67 positive rate >5% ( n=10) were lower than those without the above characteristics (all P<0.05). Conclusion:The clinical manifestations of HEHE were not typical, and the tumor was rich in mucus matrix and epithelioid endothelial cells, expressing endothelial markers. CT and MRI scan mainly showed multiple nodules or diffused lesion, and the "lollipop sign" and "target ring sign" were helpful for diagnosis. HEHE patients with Ki-67 positivity rate >5%, "target ring sign", and extrahepatic organs involvement or metastasis had a poor prognosis.
5.Kitchen Ventilation Attenuate the Association of Solid Fuel Use with Sarcopenia: A Cross-Sectional and Prospective Study.
Ying Hao YUCHI ; Wei LIAO ; Jia QIU ; Rui Ying LI ; Ning KANG ; Xiao Tian LIU ; Wen Qian HUO ; Zhen Xing MAO ; Jian HOU ; Lei ZHANG ; Chong Jian WANG
Biomedical and Environmental Sciences 2025;38(4):511-515
6.Pharmacokinetics study of Dayuanyin in normal and febrile rats.
Yu-Jie HOU ; Kang-Ning XIAO ; Jian-Yun BI ; Xin-Jun ZHANG ; Xin-Rui LI ; Yu-Qing WANG ; Ming SU ; Xin-Ru SUN ; Hui ZHANG ; Bo-Yang WANG ; Li-Jie WANG ; Shan-Xin LIU
China Journal of Chinese Materia Medica 2025;50(2):527-533
Based on the pharmacokinetics theory, this study investigated the pharmacokinetic characteristics of albiflorin, paeoniflorin, wogonoside, and wogonin in normal and febrile rats and summarized absorption and elimination rules of Dayuanyin in them to provide reference for further development and clinical application of Dayuanyin. Blood samples were taken from the fundus venous plexus of normal and model rats after intragastric administration of Dayuanyin at different time points. The concentration of each substance in blood was determined by ultra performance liquid chromatography-triple quadrupole mass spectrometry(UPLC-MS/MS) technique at different time points. DAS 2.0, a piece of pharmacokinetics software, was used to calculate the pharmacokinetic parameters of each component. The results show that the 4 components had good linear relationship in their respective ranges, and the results of methodological investigation met the requirements. The pharmacokinetic parameters of C_(max), T_(max), t_(1/2), AUC_(0-t), AUC_(0-∞), and MRT_(0-t) were calculated by the DAS 2.0 non-compartmental model. Compared with those in the normal group, C_(max) and AUC_(0-t) of the 4 components in the model group were significantly increased. There were significant differences in the pharmacokinetic characteristics between the normal and model groups, suggesting that the absorption and elimination of Dayuanyin may be affected by the changes of internal environment of the body in different physiological states.
Animals
;
Rats
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Rats, Sprague-Dawley
;
Fever/metabolism*
;
Tandem Mass Spectrometry
;
Chromatography, High Pressure Liquid
;
Glucosides/pharmacokinetics*
;
Monoterpenes
7.Identification of tissue distribution components and mechanism of antipyretic effect of famous classical formula Dayuanyin.
Yu-Jie HOU ; Kang-Ning XIAO ; Jian-Yun BI ; Xin-Rui LI ; Ming SU ; Li-Jie WANG ; Yu-Qing WANG ; Dan-Dan SUN ; Hui ZHANG ; Xin-Jun ZHANG ; Shan-Xin LIU
China Journal of Chinese Materia Medica 2025;50(10):2810-2824
Based on the ultra performance liquid chromatography-quadrupole Exactive Orbitrap mass spectrometry(UPLC-Q-Exactive Orbitrap-MS) technology, combined with related literature, databases, and reference material information, this study qualitatively analyzed the components of Dayuanyin in the tissue of rats after gavage and employed molecular docking technology to predict the rationality of the mechanism behind the antipyretic effect of the in vivo components in Dayuanyin. A total of 21, 26, 20, 21, 14, and 31 prototype components and 3, 16, 3, 7, 5, and 24 metabolites were identified from the heart, liver, spleen, lung, kidney, and hypothalamus of the rats, respectively, and the binding ability of key components and targets was further verified by molecular docking. The results showed that all components had good binding ability with targets. The established UPLC-Q-Exactive Orbitrap-MS could effectively and quickly identify the Dayuanyin components distributed in tissue and preliminarily identify their metabolites. Many components were identified in the hypothalamus, which suggested that the components delivered to the brain should be focused on in the study on Dayuanyin in the treatment of febrile diseases. The molecular docking technology was used to predict the rationality of the mechanism behind its antipyretic effect, which lays the foundation for the clarification of the material basis and action mechanism of Dayuanyin, the development of new preparations, and the prediction of quality markers.
Animals
;
Drugs, Chinese Herbal/administration & dosage*
;
Rats
;
Molecular Docking Simulation
;
Male
;
Antipyretics/metabolism*
;
Rats, Sprague-Dawley
;
Tissue Distribution
;
Mass Spectrometry
;
Chromatography, High Pressure Liquid
;
Hypothalamus/metabolism*
8.Two new taraxerane triterpenoids from mastic.
Zhi-Qiang ZHAO ; Xue-Rui AN ; Tian-Zhi LI ; Ting HE ; Hao-Kun HOU ; Wei LIU ; Tao YUAN
China Journal of Chinese Materia Medica 2025;50(13):3723-3743
Three taraxerane nortriterpenoids were isolated from mastic by using various modern chromatographic separation techniques. They were identified as(5R,8R,9R,10S,11S,12R,13S,17R,18R)-28-norlupa-11,12-epoxy-14-taraxerene-3,16-dione(1),(5R,8R,9R,10S,11S,12R,13S,17S,18S)-17-hydroxy-28-norlupa-11,12-epoxy-14-taraxerene-3-one(2), and(5R,8R,9R,10R,11S,12R,13R,14S,17S,18S)-14,17-epoxy-28-norlupa-11,12-oxidotaraxerone(3) through the high-resolution electrospray ionization mass spectrometry(HR-ESI-MS), infrared(IR), ultraviolet(UV), nuclear magnetic resonance(NMR), and single-crystal X-ray diffraction techniques as well as comparison with literature data. Compounds 1-3 were C-28 nortriterpenoids and isolated from mastic for the first time, and compounds 1-2 were new ones. In the model for RAW264.7 cell anti-inflammation induced by lipopolysaccharide(LPS), compound 1 demonstrates an inhibitory effect on nitric oxide(NO) [IC_(50)=(13.38±0.68) μmol·L~(-1)], comparable to the activity of the positive control dexamethasone [IC_(50)=(14.59±1.49) μmol·L~(-1)]. Compounds 2 and 3 exhibit weaker inhibitory effects, with IC_(50) values of(24.17±2.56) and(22.25±2.84) μmol·L~(-1), respectively.
Animals
;
Mice
;
Triterpenes/isolation & purification*
;
Drugs, Chinese Herbal/isolation & purification*
;
Mastic Resin/chemistry*
;
Nitric Oxide
;
Molecular Structure
;
Macrophages/immunology*
;
RAW 264.7 Cells
9.CDH17-targeting CAR-NK cells synergize with CD47 blockade for potent suppression of gastrointestinal cancers.
Liuhai ZHENG ; Youbing DING ; Xiaolong XU ; Huifang WANG ; Guangwei SHI ; Yang LI ; Yuanqiao HE ; Yue GONG ; Xiaodong ZHANG ; Jinxi WEI ; Zhiyu DONG ; Jiexuan LI ; Shanchao ZHAO ; Rui HOU ; Wei ZHANG ; Jigang WANG ; Zhijie LI
Acta Pharmaceutica Sinica B 2025;15(5):2559-2574
Gastrointestinal (GI) cancers are a leading cause of cancer morbidity and mortality worldwide. Despite advances in treatment, cancer relapse remains a significant challenge, necessitating novel therapeutic strategies. In this study, we engineered nanobody-based chimeric antigen receptor (CAR) natural killer (NK) cells targeting cadherin 17 (CDH17) for the treatment of GI tumors. In addition, to enhance the efficacy of CAR-NK cells, we also incorporated CV1, a CD47-SIRPα axis inhibitor, to evaluate the anti-tumor effect of this combination. We found that CDH17-CAR-NK cells effectively eliminated GI cancers cells in a CDH17-dependent manner. CDH17-CAR-NK cells also exhibit potent in vivo anti-tumor effects in cancer cell-derived xenograft and patient-derived xenograft mouse models. Additionally, the anti-tumor activity of CDH17-CAR-NK cells is synergistically enhanced by CD47-signal regulatory protein α (SIRPα) axis inhibitor CV1, likely through augmented macrophages activation and an increase in M1-phenotype macrophages in the tumor microenvironment. Collectively, our findings suggest that CDH17-targeting CAR-NK cells are a promising strategy for GI cancers. The combination of CDH17-CAR-NK cells with CV1 emerges as a potential combinatorial approach to overcome the limitations of CAR-NK therapy. Further investigations are warranted to speed up the clinical translation of these findings.
10.Comparison of the Phoenix scoring system and commonly used pediatric sepsis scores in predicting mortality risk in pediatric patients with severe sepsis under traditional standards
Haonan WANG ; Yinglang HE ; Rui TAN ; Han LI ; Xian LI ; Nan HOU ; Chen JI ; Zhe LI ; Yue WANG ; Shuangshuang PENG ; Le JING ; Liye GU ; Junjie ZHAO ; Hongjun MIAO
Chinese Journal of Burns 2025;41(3):222-231
Objective:To explore the differences between the Phoenix sepsis scoring system including Phoenix sepsis score (PSS) and Phoenix-8 organ dysfunction score (hereinafter referred to as Phoenix-8) and the commonly used pediatric sepsis scores in evaluating clinical characteristics and prognostic analysis of pediatric patients with severe sepsis diagnosed under traditional standards, namely the diagnostic criteria from the 2005 International Pediatric Sepsis Consensus Conference.Methods:This study was a retrospective observational study. From December 2020 to March 2023, 202 pediatric patients with severe sepsis meeting the inclusion criteria were admitted to the Children's Hospital of Nanjing Medical University. Based on the sepsis diagnostic criteria outlined in the International Consensus Criteria for Pediatric Sepsis and Septic Shock (2024), the pediatric patients were categorized into a sepsis group and a non-sepsis group. Sepsis group was further subdivided into a death subgroup and a survival subgroup based on the outcomes. The age, hospitalization costs, disease outcome indicators (e.g., mortality rate and incidence of septic shock), major organ (e.g., heart, liver, lungs, and kidneys) damage and their correlations, as well as PSS, Phoenix-8 and commonly used pediatric sepsis scores (e.g., pediatric sequential organ failure assessment (pSOFA), pediatric risk of mortality score Ⅲ (PRISM Ⅲ), pediatric logistic organ dysfunction-2 score (PELOD-2), pediatric multiple organ dysfunction score (P-MODS), pediatric critical illness score (PCIS), and pediatric early warning score (PEWS)) were collected and compared. Receiver operating characteristic (ROC) curve and precision-recall curve were plotted to evaluate the predictive ability of PSS, Phoenix-8, and commonly used pediatric sepsis scores for mortality risk in pediatric patients with severe sepsis under traditional standards. Predictive performance was quantified using the area under the ROC curve (AUROC). Univariate logistic regression analysis was employed to quantify the odds ratios of PSS and Phoenix-8 for predicting mortality risk. Patients with severe sepsis under traditional standards were further stratified into subgroups based on complications and comorbidities, including central nervous system (CNS) diseases, multiple infections, cardiovascular system diseases, shock, and malignancies. The Hosmer-Lemeshow goodness-of-fit test was used to assess calibration of PSS and Phoenix-8, and the DeLong test was used to compare whether there were statistically significant differences in the AUROC of PSS and Phoenix-8 for predicting mortality risk among different subgroups of pediatric patients. Results:Compared with those in non-sepsis group, pediatric patients in sepsis group were significantly older ( Z=-2.92, P<0.05) with higher incidences of septic shock and mortality, hospitalization costs, PRISM Ⅲ, PEWS, pSOFA, PELOD-2, PSS, and Phoenix-8 (with χ2 values of 21.28 and 13.64, respectively, Z values of -1.99, -5.33, -5.10, -8.55, -6.91, -10.98, and -9.93, respectively, P<0.05), and lower PCIS ( Z=-3.34, P<0.05). Compared with those in survival subgroup, hospitalization costs, PSS, Phoenix-8, PRISM Ⅲ, PEWS, pSOFA, PELOD-2, and P-MODS of pediatric patients in death subgroup was significantly higher (with Z values of -2.50, -3.50, -2.47, -5.11, -3.84, -2.94, -3.61, and -3.04, respectively, P<0.05). Compared with those in survival subgroup, the incidences of lung damage and liver damage of pediatric patients in death subgroup were also significantly higher (with χ2 values of 6.20 and 10.94, respectively, P<0.05), and 64.7% (97/150) of patients exhibited two or more concurrent organ damage. For predicting mortality risk in pediatric patients with severe sepsis under traditional standards, the AUROC values for PRISM Ⅲ, PCIS, PEWS, pSOFA, PELOD-2, P-MODS, PSS, and Phoenix-8 were approximately 0.70, with optimal cutoff values of 17.5, 91.0, 5.5, 4.5, 2.5, 4.5, 3.5, and 4.5, respectively; PELOD-2 demonstrated the highest sensitivity (0.83); while PRISM Ⅲ, PSS, and Phoenix-8 showed high specificity (>0.80). Univariate logistic regression analysis showed that for every 1-point increase in the PSS within 24 hours of pediatric intensive care unit admission, the relative risk of mortality increased by 63.7% (with odds ratio of 1.64, 95% confidence interval of 1.34-1.99, P<0.05). Similarly, for every 1-point increase in the Phoenix-8, the relative risk of mortality increased by 37.5% (with odds ratio of 1.38, 95% confidence interval of 1.18-1.60, P<0.05). The AUROC values (around 0.80) of PSS and Phoenix-8 for predicting mortality risk in pediatric patients with severe sepsis combined with CNS diseases, multiple infections, and cardiovascular system diseases were relatively high. In contrast, the AUROC values (0.60-0.80) for predicting mortality risk in pediatric patients with severe sepsis combined with shock or malignant tumors were moderate. All models passed the Hosmer-Lemeshow goodness-of-fit test ( P>0.05). The DeLong test indicated no statistically significant differences in predictive ability between PSS and Phoenix-8 across subgroups of pediatric patients ( P>0.05). Conclusions:PSS and Phoenix-8 exhibited higher specificity than most of the commonly used pediatric sepsis scores in predicting mortality risk under traditional standards. Both scores performed much better in predicting the mortality risk in pediatric patients with severe sepsis combined with CNS diseases, multiple infections, and cardiovascular system diseases.

Result Analysis
Print
Save
E-mail