1.Real-time core competency assessment by mobile terminal in the standardized training of internal medicine residents
Aiwei LI ; Guan WANG ; Xiaoyan SUN ; Yuanmei LIU ; Dan LI ; Shan YE ; Changqing CUI ; Rui WU ; Yan LI ; Jiangli HAN ; Ning SHEN
Chinese Journal of Medical Education Research 2025;24(1):121-125
Objective:To assess the core competencies of internal medicine residents undergoing standardized residency training and to explore the effectiveness of core competency evaluation on mobile devices.Methods:The mobile formative evaluation module was developed based on the "Xueyiku" teaching management platform. From January to December 2023, clinical teachers were asked to evaluate 150 internal medicine residents based on the "Resident Core Competency Milestone Evaluation System in China Consortium of Elite Teaching Hospitals", and the results were analyzed using non-parametric tests.Results:Among the six core competencies of internal medicine residents, professionalism received the highest score, whereas teaching skill received a lower score (97.50 vs. 90.00; H=167.31, P<0.001). Second-year residents had significantly higher scores than first-year residents (93.00 vs. 90.00; P<0.001), but similar scores to third-year residents (93.00 vs. 93.00; P>0.05). In addition, there was no significant difference in score among residents with different medical education backgrounds ( P>0.05). Conclusions:More emphasis should be placed on improving the teaching skills of internal medicine residents, along with the implementation of tiered progressive training. The mobile core competency evaluation is an effective means for assessing the comprehensive skills of residents in a timely manner.
2.A study of the accuracy and radiation dose of the use of portable X-ray machine for orientation of foreign body in navigation surgery
Dan MA ; Rui XIE ; Xin WANG ; Chen LIU ; Wei WU ; Yimin ZHAO ; Shizhu BAI
Journal of Practical Stomatology 2025;41(1):16-20
Objective:To assess the feasibility and security the orientation of foreign bodies using a portable X-ray machine in computer-aided navigation surgery.Methods:A model with a metallic foreign body was constructed.Under the fluoroscopy of a portable X-ray machine,4 points on 2 straight lines passing through the tip of the foreign body were recorded by the navigation e-quipment,and subsequently,the midpoints of the common perpendicular segments of the 2 lines were calculated as the coordinates of the foreign body(Bilinear Method).2 operators measured the coordinates of the foreign body 10 times and compared the measured coordinates of the foreign body with the actual coordinates of the foreign body in order to analyze the accuracy of the Bilinear Method.Radiation doses to model area and operators at different locations were measured using ionizing radiation detectors.Results:The ac-curacy of the Bilinear Method for measuring foreign body coordinates was(1.98±0.77)mm,and that of the 2 operators was 1.55±0.68 and 2.40±0.36 respectively(P=0.02).The radiation dose was(221.45±50.15)μSv in the model and(4.44±1.35)μSv in the operator's chest.Conclusion:The accuracy of the coordinates of the foreign body intraoperation measured by Bilinear Method meets general clinical needs,and different operators may produce different accuracy.The radiation dose is small.
3.Study on injury of vascular intima with hemostatic clamp and optimization of protective strategy
Lizhi REN ; Qianqian WANG ; Dan WANG ; Zepeng ZHANG ; Xiaofen WU ; Rui SUN
Chinese Journal of Stomatology 2025;60(5):501-508
Objective:To explore the intimal injury of two kinds of hemostatic clips under different clamping forces, and to optimize and verify the calculation formula of minimum occlusion force (MOF), so as to provide theoretical basis for selecting appropriate hemostatic clips to reduce vascular injury.Methods:A total of 96 male SD rats with body weight ranging from 280 to 300 g (Animal Experimental Center of Shanxi Medical University) were randomly assigned to metal hemostatic clip group ( n=48) and disposable hemostatic clip group ( n=48) by random number table method. Each group was further divided into four subgroups with clamping forces of 0.3, 0.6, 0.9 and 1.2 N for abdominal aortic injury experiments. The damage to the vascular intima was observed under a scanning electron microscope. A vascular closure model was established for mathematical analysis to derive the theoretical calculation formula of the arterial blood management factor (MOF). According to blood pressure (BP), blood vessel diameter (D) and hemostatic clamp width (W), the average values of theoretical and actual MOF data were analyzed by paired t test to verify the accuracy of the formula. From January 2021 to December 2022, six patients (with 12 branch arteries) who presented with oral and maxillofacial malignancies at the Department of Oral and Maxillofacial Surgery, Shanxi Medical University School and Hospital of Stomatology, were included to validate the accuracy of the MOF formula. Results:Under electron microscopy, when the clamping force was 0.3 N, the one-time hemostatic clip caused very little damage to the vascular intima (grade 1 injury), with only a few folds being flattened. When the clamping force was 0.6 N, both types of hemostatic clips caused partial peeling of the intima surface (grade 2-3 injury). However, when the clamping force was adjusted to 0.9 and 1.2 N, the damage caused by both types of hemostatic clips was more severe (grade 3-4 injury), with large areas of intima peeling or even disappearance. In some specimens of the metal hemostatic clip group, the damage even reached the muscular layer. Vascular closure model analysis showed that MOF=2×(1/2×π×D×W×BP), the mean diameter of abdominal aorta of 24 SD rats was (1.41±0.07) mm, the blood pressure was (83.29±11.56) mmHg (1 mmHg=0.133 kPa). The theoretical MOF value was (0.096±0.015) N, the actual clamping force (ACF) was (0.095±0.012) N, there was no statistical significance between the two groups ( t=-0.35, P=0.725). In clinical application, the MOF calculation formula was used to select the appropriate hemostatic clip for 12 arteries, successfully blocking the blood flow, verifying the accuracy of the formula. Conclusions:Hemostatic clips can cause damage to the inner membrane of blood vessels, and the greater the clamping force, the more severe the damage. Disposable hemostatic clips have certain advantages in avoiding excessive damage to the inner membrane of blood vessels. The theoretical MOF calculation formula has a certain degree of reliability and can be used as a reference to select the appropriate hemostatic clip with low damage.
4.Application of cymene care solution in prognostic management of chronic periodontitis
Bing HAN ; Dan WANG ; Hao GUO ; Tong ZUO ; Ya'nan SHI ; Juan TONG ; Huan ZHANG ; Rui LIU
Journal of Practical Stomatology 2025;41(3):417-419
40 patients with choronic periodontitis underwent periodontal basic treatment were randomly divided into 2 groups(n=20).The patients in control group used special toothpaste and toothbrush to brush their teeth after meals,those in the experimental group brushed their teeth with special toothpaste and toothbrush in the morning,evening and after meals,and wore personalized film pressing trays containing cymene care solution while sleeping at night.Gingival bleeding,periodontal pocket depth and attachment loss were ob-served after 4,6 and 10 weeks respectively.The personalized tray combined with cymbidium reduced the depth of periodontal pocket(P<0.05)and the rate of probing bleeding sites(P<0.05)more effectively,and showed no statistical significance in the change of attachment loss(P<0.05).Cymene care solution is effective in the improvement of periodontal health.
5.Study on injury of vascular intima with hemostatic clamp and optimization of protective strategy
Lizhi REN ; Qianqian WANG ; Dan WANG ; Zepeng ZHANG ; Xiaofen WU ; Rui SUN
Chinese Journal of Stomatology 2025;60(5):501-508
Objective:To explore the intimal injury of two kinds of hemostatic clips under different clamping forces, and to optimize and verify the calculation formula of minimum occlusion force (MOF), so as to provide theoretical basis for selecting appropriate hemostatic clips to reduce vascular injury.Methods:A total of 96 male SD rats with body weight ranging from 280 to 300 g (Animal Experimental Center of Shanxi Medical University) were randomly assigned to metal hemostatic clip group ( n=48) and disposable hemostatic clip group ( n=48) by random number table method. Each group was further divided into four subgroups with clamping forces of 0.3, 0.6, 0.9 and 1.2 N for abdominal aortic injury experiments. The damage to the vascular intima was observed under a scanning electron microscope. A vascular closure model was established for mathematical analysis to derive the theoretical calculation formula of the arterial blood management factor (MOF). According to blood pressure (BP), blood vessel diameter (D) and hemostatic clamp width (W), the average values of theoretical and actual MOF data were analyzed by paired t test to verify the accuracy of the formula. From January 2021 to December 2022, six patients (with 12 branch arteries) who presented with oral and maxillofacial malignancies at the Department of Oral and Maxillofacial Surgery, Shanxi Medical University School and Hospital of Stomatology, were included to validate the accuracy of the MOF formula. Results:Under electron microscopy, when the clamping force was 0.3 N, the one-time hemostatic clip caused very little damage to the vascular intima (grade 1 injury), with only a few folds being flattened. When the clamping force was 0.6 N, both types of hemostatic clips caused partial peeling of the intima surface (grade 2-3 injury). However, when the clamping force was adjusted to 0.9 and 1.2 N, the damage caused by both types of hemostatic clips was more severe (grade 3-4 injury), with large areas of intima peeling or even disappearance. In some specimens of the metal hemostatic clip group, the damage even reached the muscular layer. Vascular closure model analysis showed that MOF=2×(1/2×π×D×W×BP), the mean diameter of abdominal aorta of 24 SD rats was (1.41±0.07) mm, the blood pressure was (83.29±11.56) mmHg (1 mmHg=0.133 kPa). The theoretical MOF value was (0.096±0.015) N, the actual clamping force (ACF) was (0.095±0.012) N, there was no statistical significance between the two groups ( t=-0.35, P=0.725). In clinical application, the MOF calculation formula was used to select the appropriate hemostatic clip for 12 arteries, successfully blocking the blood flow, verifying the accuracy of the formula. Conclusions:Hemostatic clips can cause damage to the inner membrane of blood vessels, and the greater the clamping force, the more severe the damage. Disposable hemostatic clips have certain advantages in avoiding excessive damage to the inner membrane of blood vessels. The theoretical MOF calculation formula has a certain degree of reliability and can be used as a reference to select the appropriate hemostatic clip with low damage.
6.A convenient research strategy for functional verification of epigenetic regulators during spermatogenesis.
Shan LI ; Ying YUAN ; Ke-Yu ZHANG ; Yi-Dan GUO ; Lu-Tong WANG ; Xiao-Yuan ZHANG ; Shu ZHANG ; Qi YAN ; Rong ZHANG ; Jie CHEN ; Feng-Tang YANG ; Jing-Rui LI
Asian Journal of Andrology 2025;27(2):261-267
Spermatogenesis is a fundamental process that requires a tightly controlled epigenetic event in spermatogonial stem cells (SSCs). The mechanisms underlying the transition from SSCs to sperm are largely unknown. Most studies utilize gene knockout mice to explain the mechanisms. However, the production of genetically engineered mice is costly and time-consuming. In this study, we presented a convenient research strategy using an RNA interference (RNAi) and testicular transplantation approach. Histone H3 lysine 9 (H3K9) methylation was dynamically regulated during spermatogenesis. As Jumonji domain-containing protein 1A (JMJD1A) and Jumonji domain-containing protein 2C (JMJD2C) demethylases catalyze histone H3 lysine 9 dimethylation (H3K9me2), we firstly analyzed the expression profile of the two demethylases and then investigated their function. Using the convenient research strategy, we showed that normal spermatogenesis is disrupted due to the downregulated expression of both demethylases. These results suggest that this strategy might be a simple and alternative approach for analyzing spermatogenesis relative to the gene knockout mice strategy.
Spermatogenesis/physiology*
;
Animals
;
Male
;
Mice
;
Epigenesis, Genetic
;
Jumonji Domain-Containing Histone Demethylases/metabolism*
;
Histones/metabolism*
;
RNA Interference
;
Testis/metabolism*
;
Methylation
;
Mice, Knockout
;
Histone Demethylases
7.Body fat distribution and semen quality in 4304 Chinese sperm donors.
Si-Han LIANG ; Qi-Ling WANG ; Dan LI ; Gui-Fang YE ; Ying-Xin LI ; Wei ZHOU ; Rui-Jun XU ; Xin-Yi DENG ; Lu LUO ; Si-Rong WANG ; Xin-Zong ZHANG ; Yue-Wei LIU
Asian Journal of Andrology 2025;27(4):524-530
Extensive studies have identified potential adverse effects on semen quality of obesity, based on body mass index, but the association between body fat distribution, a more relevant indicator for obesity, and semen quality remains less clear. We conducted a longitudinal study of 4304 sperm donors from the Guangdong Provincial Human Sperm Bank (Guangzhou, China) during 2017-2021. A body composition analyzer was used to measure total and local body fat percentage for each participant. Generalized estimating equations were employed to assess the association between body fat percentage and sperm count, motility, and morphology. We estimated that each 10% increase in total body fat percentage (estimated change [95% confidence interval, 95% CI]) was significantly associated with a 0.18 × 10 6 (0.09 × 10 6 -0.27 × 10 6 ) ml and 12.21 × 10 6 (4.52 × 10 6 -19.91 × 10 6 ) reduction in semen volume and total sperm count, respectively. Categorical analyses and exposure-response curves showed that the association of body fat distribution with semen volume and total sperm count was stronger at higher body fat percentages. In addition, the association still held among normal weight and overweight participants. We observed similar associations for upper limb, trunk, and lower limb body fact distributions. In conclusion, we found that a higher body fat distribution was significantly associated with lower semen quality (especially semen volume) even in men with a normal weight. These findings provide useful clues in exploring body fat as a risk factor for semen quality decline and add to evidence for improving semen quality for those who are expected to conceive.
Humans
;
Male
;
Adult
;
Semen Analysis
;
China
;
Body Fat Distribution
;
Longitudinal Studies
;
Sperm Count
;
Sperm Motility
;
Body Mass Index
;
Tissue Donors
;
Obesity/complications*
;
Spermatozoa
;
Young Adult
;
Middle Aged
;
East Asian People
8.A large family of Nascimento form of syndromic X-linked intellectual developmental disorder caused by large segment deletion of the UBE2A gene: a case report and literature review.
Dan XU ; Jia-Yang XIE ; Xiao-Li ZHANG ; Meng-Yue WANG ; Man-Man CHU ; Rui HAN ; Jun-Ling WANG ; Xiao-Li LI ; Tian-Ming JIA
Chinese Journal of Contemporary Pediatrics 2025;27(7):859-863
This article reports the clinical features and gene mutation types of a large family with Nascimento form of syndromic X-linked intellectual developmental disorder (MRXSN), involving 9 individuals across 3 generations, and a literature review was conducted. In this family, 9 individuals had similar manifestations including mental retardation and unusual facies, and 4 of them had passed away. Genetic testing showed that the proband had the deletion of exons 2-3 of the UBE2A gene, which was inherited from the mother. Fluorescent quantitative polymerase chain reaction showed that the proband and his uncle had the deletion of exons 2-3 of the UBE2A gene; the proband's mother, grandmother, and great-aunt had a heterozygous deletion of exons 2-3 of the UBE2A gene; the proband's father, sister, and aunt had a normal copy number of exons 2-3 of the UBE2A gene. The 34 patients reported in the literature had diverse clinical phenotypes, and UBE2A gene mutations (22/34, 65%) and large fragment deletions (12/34, 35%) were the main mutation types. Moderate to severe mental retardation (34/34, 100%), speech and language impairment (33/34, 97%), and unusual facies (32/34, 94%) were the main clinical manifestations of MRXSN patients. The disease has obvious phenotypic heterogeneity, and early diagnosis facilitates optimal prenatal and postnatal management to improve reproductive outcomes.
Humans
;
Male
;
Ubiquitin-Conjugating Enzymes/genetics*
;
Female
;
X-Linked Intellectual Disability/genetics*
;
Gene Deletion
;
Child
;
Pedigree
;
Child, Preschool
;
Adult
9.Ultra-early administration of eculizumab in a child with atypical hemolytic uremic syndrome: a case report.
Dan-Dan GUO ; Yi-Xin XIAO ; Wei-Rui WANG ; Xiao-Lu DENG ; Ye-Hong HUANG
Chinese Journal of Contemporary Pediatrics 2025;27(11):1408-1413
A 10-year-old girl was admitted with a 38-hour history of widespread subcutaneous petechiae and hematuria and a 6-hour history of jaundice and oliguria. Physical examination revealed widespread subcutaneous petechiae and jaundice of the skin and sclera. Laboratory tests showed anemia, thrombocytopenia, acute kidney injury, and markedly elevated lactate dehydrogenase. Thrombotic microangiopathy was initially diagnosed, with a high suspicion of atypical hemolytic uremic syndrome (aHUS). Eculizumab was initiated within 9 hours of admission (within 48 hours of onset). After the first infusion, hemolysis rapidly ceased, and the platelet count and renal function gradually returned to normal. Whole-exome sequencing identified homozygous deletions of CFHR1 exon 2 and CFHR4 exon 1. aHUS typically has abrupt onset and rapid progression. Clinicians should maintain high suspicion for aHUS when the triad of thrombocytopenia, microangiopathic hemolytic anemia, and acute kidney injury is present. Ultra-early eculizumab (within 48 hours of onset) rapidly blocks complement-mediated thrombotic microangiopathy, reverses organ injury, and improves long-term prognosis. Additionally, complement-related genetic testing is important for etiological clarification and individualized determination of eculizumab treatment duration.
Humans
;
Antibodies, Monoclonal, Humanized/administration & dosage*
;
Female
;
Atypical Hemolytic Uremic Syndrome/drug therapy*
;
Child
;
Complement C3b Inactivator Proteins
10.Causal Associations between Particulate Matter 2.5 (PM 2.5), PM 2.5 Absorbance, and Inflammatory Bowel Disease Risk: Evidence from a Two-Sample Mendelian Randomization Study.
Xu ZHANG ; Zhi Meng WU ; Lu ZHANG ; Bing Long XIN ; Xiang Rui WANG ; Xin Lan LU ; Gui Fang LU ; Mu Dan REN ; Shui Xiang HE ; Ya Rui LI
Biomedical and Environmental Sciences 2025;38(2):167-177
OBJECTIVE:
Several epidemiological observational studies have related particulate matter (PM) exposure to Inflammatory bowel disease (IBD), but many confounding factors make it difficult to draw causal links from observational studies. The objective of this study was to explore the causal association between PM 2.5 exposure, its absorbance, and IBD.
METHODS:
We assessed the association of PM 2.5 and PM 2.5 absorbance with the two primary forms of IBD (Crohn's disease [CD] and ulcerative colitis [UC]) using Mendelian randomization (MR) to explore the causal relationship. We conducted two-sample MR analyses with aggregated data from the UK Biobank genome-wide association study. Single-nucleotide polymorphisms linked with PM 2.5 concentrations or their absorbance were used as instrumental variables (IVs). We used inverse variance weighting (IVW) as the primary analytical approach and four other standard methods as supplementary analyses for quality control.
RESULTS:
The results of MR demonstrated that PM 2.5 had an adverse influence on UC risk (odds ratio [ OR] = 1.010; 95% confidence interval [ CI] = 1.001-1.019, P = 0.020). Meanwhile, the results of IVW showed that PM 2.5 absorbance was also causally associated with UC ( OR = 1.012; 95% CI = 1.004-1.019, P = 0.002). We observed no causal relationship between PM 2.5, PM 2.5 absorbance, and CD. The results of sensitivity analysis indicated the absence of heterogeneity or pleiotropy, ensuring the reliability of MR results.
CONCLUSION
Based on two-sample MR analyses, there are potential positive causal relationships between PM 2.5, PM 2.5 absorbance, and UC.
Humans
;
Mendelian Randomization Analysis
;
Particulate Matter/analysis*
;
Polymorphism, Single Nucleotide
;
Inflammatory Bowel Diseases/genetics*
;
Air Pollutants/analysis*
;
Crohn Disease/genetics*
;
Colitis, Ulcerative/genetics*
;
Genome-Wide Association Study
;
Risk Factors
;
Environmental Exposure

Result Analysis
Print
Save
E-mail