1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Strategic Optimization of CHO Cell Expression Platforms for Biopharmaceutical Manufacturing
Rui-Ming ZHANG ; Meng-Lin LI ; Hong-Wei ZHU ; Xing-Xiao ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):327-341
Chinese hamster ovary (CHO) cells are the most established and versatile mammalian expression system for the large-scale production of recombinant therapeutic proteins, owing to their genetic stability, adaptability to serum-free suspension culture, and ability to perform human-like post-translational modifications. More than 70% of biologics approved by the U.S. Food and Drug Administration rely on CHO-based production platforms, underscoring their central role in modern biopharmaceutical manufacturing. Despite these advantages, CHO systems continue to face three persistent bottlenecks that limit their potential for high-yield, reproducible, and cost-efficient production: excessive metabolic burden during high-density culture, heterogeneity of glycosylation patterns, and progressive loss of long-term expression stability. This review provides an integrated analysis of recent advances addressing these challenges and proposes a forward-looking framework for constructing intelligent and sustainable CHO cell factories. In terms of metabolic regulation, excessive lactate and ammonia accumulation disrupts energy balance and reduces recombinant protein synthesis efficiency. Optimization of culture parameters such as temperature, pH, dissolved oxygen, osmolarity, and glucose feeding can effectively alleviate metabolic stress, while supplementation with modulators including sodium butyrate, baicalein, and S-adenosylmethionine promotes specific productivity (qP) by modulating apoptosis and chromatin structure. Furthermore, genetic engineering strategies—such as overexpression of MPC1/2, HSP27, and SIRT6 or knockout of Bax, Apaf1, and IGF-1R—have demonstrated significant improvements in cell viability and product yield. The combination of multi-omics metabolic modeling with artificial intelligence (AI)-based prediction offers new opportunities for building self-regulating CHO systems capable of dynamic adaptation to environmental stress. Regarding glycosylation uniformity, which determines therapeutic efficacy and immunogenicity, gene editing-based glycoengineering (e.g., FUT8 knockdown or ST6Gal1 overexpression) has enabled the humanization of CHO glycan profiles, minimizing non-human sugar residues and enhancing drug stability. Process-level strategies such as galactose or manganese co-feeding and fine control of temperature or osmolarity further allow rational regulation of glycosyltransferase activity. Additionally, in vitro chemoenzymatic remodeling provides a complementary route to construct human-type glycans with defined structures, though industrial applications remain constrained by cost and scalability. The integration of model-driven process design and AI feedback control is expected to enable real-time prediction and correction of glycosylation deviations, ensuring batch-to-batch consistency in continuous biomanufacturing. Long-term expression stability, another critical challenge, is often impaired by promoter silencing, chromatin condensation, and random genomic integration. Molecular optimization—such as the use of improved promoters (CMV, EF-1α, or CHO endogenous promoters), Kozak and signal peptide refinement, and incorporation of chromatin-opening elements (UCOE, MAR, STAR)—helps maintain durable transcriptional activity, while site-specific integration systems including Cre/loxP, Flp/FRT, φC31, and CRISPR/Cas9 can enable single-copy, position-independent gene insertion at genomic safe-harbor loci, ensuring stable, predictable expression. Collectively, this review highlights a paradigm shift in CHO system optimization driven by the convergence of genome editing, synthetic biology, and artificial intelligence. The transition from empirical optimization to rational, data-driven design will facilitate the development of programmable CHO platforms capable of autonomous regulation of metabolic flux, glycosylation fidelity, and transcriptional activity. Such intelligent cell factories are expected to accelerate the transformation from laboratory-scale research to industrial-scale, high-consistency, and economically sustainable biopharmaceutical manufacturing, thereby supporting the next generation of efficient and customizable biologics manufacturing.
3.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
4.Strategic Optimization of CHO Cell Expression Platforms for Biopharmaceutical Manufacturing
Rui-Ming ZHANG ; Meng-Lin LI ; Hong-Wei ZHU ; Xing-Xiao ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):327-341
Chinese hamster ovary (CHO) cells are the most established and versatile mammalian expression system for the large-scale production of recombinant therapeutic proteins, owing to their genetic stability, adaptability to serum-free suspension culture, and ability to perform human-like post-translational modifications. More than 70% of biologics approved by the U.S. Food and Drug Administration rely on CHO-based production platforms, underscoring their central role in modern biopharmaceutical manufacturing. Despite these advantages, CHO systems continue to face three persistent bottlenecks that limit their potential for high-yield, reproducible, and cost-efficient production: excessive metabolic burden during high-density culture, heterogeneity of glycosylation patterns, and progressive loss of long-term expression stability. This review provides an integrated analysis of recent advances addressing these challenges and proposes a forward-looking framework for constructing intelligent and sustainable CHO cell factories. In terms of metabolic regulation, excessive lactate and ammonia accumulation disrupts energy balance and reduces recombinant protein synthesis efficiency. Optimization of culture parameters such as temperature, pH, dissolved oxygen, osmolarity, and glucose feeding can effectively alleviate metabolic stress, while supplementation with modulators including sodium butyrate, baicalein, and S-adenosylmethionine promotes specific productivity (qP) by modulating apoptosis and chromatin structure. Furthermore, genetic engineering strategies—such as overexpression of MPC1/2, HSP27, and SIRT6 or knockout of Bax, Apaf1, and IGF-1R—have demonstrated significant improvements in cell viability and product yield. The combination of multi-omics metabolic modeling with artificial intelligence (AI)-based prediction offers new opportunities for building self-regulating CHO systems capable of dynamic adaptation to environmental stress. Regarding glycosylation uniformity, which determines therapeutic efficacy and immunogenicity, gene editing-based glycoengineering (e.g., FUT8 knockdown or ST6Gal1 overexpression) has enabled the humanization of CHO glycan profiles, minimizing non-human sugar residues and enhancing drug stability. Process-level strategies such as galactose or manganese co-feeding and fine control of temperature or osmolarity further allow rational regulation of glycosyltransferase activity. Additionally, in vitro chemoenzymatic remodeling provides a complementary route to construct human-type glycans with defined structures, though industrial applications remain constrained by cost and scalability. The integration of model-driven process design and AI feedback control is expected to enable real-time prediction and correction of glycosylation deviations, ensuring batch-to-batch consistency in continuous biomanufacturing. Long-term expression stability, another critical challenge, is often impaired by promoter silencing, chromatin condensation, and random genomic integration. Molecular optimization—such as the use of improved promoters (CMV, EF-1α, or CHO endogenous promoters), Kozak and signal peptide refinement, and incorporation of chromatin-opening elements (UCOE, MAR, STAR)—helps maintain durable transcriptional activity, while site-specific integration systems including Cre/loxP, Flp/FRT, φC31, and CRISPR/Cas9 can enable single-copy, position-independent gene insertion at genomic safe-harbor loci, ensuring stable, predictable expression. Collectively, this review highlights a paradigm shift in CHO system optimization driven by the convergence of genome editing, synthetic biology, and artificial intelligence. The transition from empirical optimization to rational, data-driven design will facilitate the development of programmable CHO platforms capable of autonomous regulation of metabolic flux, glycosylation fidelity, and transcriptional activity. Such intelligent cell factories are expected to accelerate the transformation from laboratory-scale research to industrial-scale, high-consistency, and economically sustainable biopharmaceutical manufacturing, thereby supporting the next generation of efficient and customizable biologics manufacturing.
5.Clinical efficacy of single branch stent-graft treatment for retrograde type A intramural hematoma: A retrospective cohort study
Bailang CHEN ; Zanxin WANG ; Xianmian ZHUANG ; Haibing LIU ; Yao CHEN ; Rui ZHANG ; Minxin WEI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1166-1172
Objective To explore the efficacy of using a single branch stent-graft to treat primary intramural hematoma located at the distal arch or descending aorta in Stanford A type aortic intramural hematoma. Methods From July 2020 to November 2022, 10 patients with primary intramural hematoma of Stanford A type aortic intramural hematoma were treated with endovascular repair using a single branch stent-graft in the Department of Cardiovascular Surgery at The University of Hong Kong-Shenzhen Hospital. There were 9 males and 1 female, aged from 32 to 66 years, with a mean age of (47.0±10.4) years. All patients had intramural hematoma involving the ascending aorta and aortic arch, diagnosed as type A intramural hematoma, with the tear located in the descending aorta. Among them, 6 patients were complicated by ulceration of the descending aorta with intramural hematoma, and 4 patients had changes of the descending aortic dissection. All patients underwent endovascular stent repair, with 8 patients undergoing emergency surgery (≤14 days) and 2 patients undergoing subacute surgery (15 days to 3 months). Results There were no neurological complications, paraplegia, stent fracture or displacement, or limb or visceral ischemia during the perioperative period in all patients. One patient had continuous chest pain after surgery, and the stent had a new tear at the proximal end, requiring ascending aorta and partial arch replacement. As of the latest follow-up, all patients had obvious absorption or complete absorption of the intramural hematoma in the ascending aorta and aortic arch compared with before the operation. Conclusion Single branch stent-graft treatment of retrograde ascending aortic intramural hematoma is safe and effective, with good short-term results.
6.Expert consensus on clinical application of Suhuang Zhike Capsules in treatment of respiratory diseases.
Yu MING ; Chang-Rui HUANG ; Bang YU ; Wen-Jing CHANG ; Zeng-Tao SUN ; Wei CHEN ; Hong-Chun ZHANG
China Journal of Chinese Materia Medica 2025;50(3):817-823
Suhuang Zhike Capsules are widely used in clinical practice for the treatment of respiratory diseases and have been included in Medicine Catalogue for National Basic Medical Insurance, Work Injury Insurance, and Maternity Insurance and National Essential Medicines List. However, problems remain, such as unclear definitions of treatment courses and unidentified contraindications for certain populations. Therefore, this consensus was developed collaboratively by clinical experts in traditional Chinese medicine(TCM) related to pulmonary diseases, respiratory, and critical care medicine, as well as methodology and pharmacy experts, adhering strictly to the consensus development procedures established by the China Association of Chinese Medicine for clinical application of Chinese patent medicines, with the aim to guide the correct clinical use of Suhuang Zhike Capsules for the treatment of cough variant asthma, post-infectious cough, and other respiratory diseases. This consensus employed questionnaire surveys and expert interviews to identify clinical concerns based on the PICOS principle and conduct evidence evaluation and GRADE grading. Utilizing nominal group techniques and GRADE networking methods, it resulted in 17 recommendations and consensus suggestions. The consensus further clarifies the indications, TCM syndromes, usage, and clinical safety of Suhuang Zhike Capsules in the treatment of cough variant asthma and post-infectious cough, aiming to promote standardized medication use and facilitate the rational clinical application of Suhuang Zhike Capsules.
Humans
;
Drugs, Chinese Herbal/administration & dosage*
;
Consensus
;
Capsules
;
Respiratory Tract Diseases/drug therapy*
;
Medicine, Chinese Traditional
7.Comparison between sinking and floating fresh Rehmanniae Radix samples by UHPLC-Q-Orbitrap HRMS, fingerprinting, and chemometrics.
Shi-Long LIU ; Hong-Wei ZHANG ; Zhen-Ling ZHANG ; Han-Ting JIA ; Zhi-Jun GUO ; Rui-Sheng WANG ; Hong-Wei ZHANG ; Shuo WANG ; Yi-Jian ZHONG
China Journal of Chinese Materia Medica 2025;50(14):3918-3929
This study aims to explore the scientific connotation of sinking Rehmanniae Radix has the best quality and compare the quality between floating and sinking fresh Rehmanniae Radix samples. Ultra-performance liquid chromatography tandem quadrupole electrostatic field Orbitrap high-resolution mass spectrometry(UHPLC-Q-Orbitrap HRMS) was employed to detect the chemical components in floating and sinking fresh Rehmanniae Radix samples. The fingerprint of fresh Rehmanniae Radix was established by high performance liquid chromatography(HPLC), and four index components were determined simultaneously. The cluster analysis, principal component analysis(PCA), and orthogonal partial least squares-discriminant analysis(OPLS-DA) were conducted to compare the quality of floating and sinking fresh Rehmanniae Radix samples. An evaporative light-scattering detector was used to compare the content of five sugars. The extract yield and drying rate were determined, and the quality connotation of sinking Rehmanniae Radix has the best quality was explained by multiple indicators. A total of 41 components were preliminarily identified from fresh Rehmanniae Radix by UHPLC-Q-Orbitrap HRMS, including 7 iridoid glycosides, 9 phenylethanol glycosides, 6 amino acids, 4 sugars, 3 phenolic acids, 5 nucleosides, 3 organic acids, 1 ionone, 1 furan, 1 coumarin, and 1 phenylpropanoid. The results showed that the main chemical components were consistent between floating and sinking fresh Rehmanniae Radix. Nine common peaks were identified in the fingerprints of 15 batches of floating and sinking fresh Rehmanniae Radix samples, and the similarity of fingerprints was greater than 0.9. The cluster analysis, PCA, and OPLS-DA classified floating and sinking fresh Rehmanniae Radix sasmples into two categories, indicating differences in the quality between them. The total content of catalpol, rehmannioside D, ajugol, and verbascoside in sinking fresh Rehmanniae Radix samples was higher than that in floating samples of the same batch and specification, and the main differential component was catalpol. The total content of fructose, glucose, sucrose, raffinose, and stachyose in sinking fresh Rehmanniae Radix samples was higher than that in floating samples of the same batch and specification, and the main differential component was stachyose. The extract yield and drying rate of the sinking samples were higher than those of floating samples. This study preliminarily showed that floating and sinking fresh Rehmanniae Radix samples had the same components but great differences in the content of medicinal substance basis. The total content of four glycosides and five sugars, extract yield, and drying rate of sinking fresh Rehmanniae Radix samples is higher than that of floating samples of the same batch and specification. These findings, to a certain extent, explains the scientificity of sinking Rehmanniae Radix has the best quality recorded in ancient books and provide a reference for the quality control and clinical application of fresh Rehmanniae Radix.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Rehmannia/chemistry*
;
Chemometrics
;
Mass Spectrometry/methods*
;
Quality Control
;
Principal Component Analysis
;
Plant Extracts
8.Modified Sini Powder in treating mild to moderate generalized anxiety disorder in patients with syndrome of liver depression transforming into fire: a single-center, randomized, double-blind, dose-controlled trial.
Jia-Xin XU ; Hong-Jun YANG ; Hong-Wei WU ; Li-Jun MAO ; Jian-Xin WANG ; Zong-Liang YU ; Yang ZHAO ; Xiao-Nan HAO ; Rui GAO
China Journal of Chinese Materia Medica 2025;50(14):4063-4070
A single-center, randomized, double-blind, dose-controlled trial of modified Sini Powder in treating mild to moderate generalized anxiety disorder(GAD) in the patients with syndrome of liver depression transforming into fire was conducted at Xiyuan Hospital, China Academy of Chinese Medical Sciences. A total of 80 patients with mild to moderate GAD and the syndrome of liver depression transforming into fire were included. Patients were assigned by the central randomization system at a ratio of 3∶1 into an observation group(n=60, receiving a conventional-dose of granules of modified Sini Powder) and a control group(n=20, receiving low-dose granules with the active ingredients being 50% of that in observation group). Assessments were conducted before treatment(baseline), after 2 weeks of introduction, after 2/4/8 weeks of treatment, and after 4 weeks of follow-up. The results were summarized as follows. In terms of primary outcome indicators, the observation group(62.2%) showed higher total response rate than the control group(26.6%)(P<0.05), and greater Hamilton anxiety scale(HAMA) score reduction after 8 weeks of treatment(P<0.05). In terms of secondary outcome indicators, the HAMA score(somatic anxiety score), traditional Chinese medicine(TCM) syndrome scores, Pittsburgh sleep quality index(PSQI) scale, and clinical global impression(CGI) scale score in the observation group showed a significant compared to the control group at each visit points(P<0.05). Adverse events occurred in 10 cases, including 9(16.9%) cases in the observation group and 1(6.6%) case in the control group. No adverse reaction was observed. In conclusion, conventional-dose modified Sini Powder demonstrated superior efficacy and favorable safety for mild and moderate GAD in the patients with the syndrome of liver depression transforming into fire over low-dose treatment.
Humans
;
Male
;
Female
;
Adult
;
Middle Aged
;
Double-Blind Method
;
Drugs, Chinese Herbal/administration & dosage*
;
Anxiety Disorders/drug therapy*
;
Treatment Outcome
;
Young Adult
;
Powders
;
Aged
;
Liver/drug effects*
;
Generalized Anxiety Disorder
9.Ultra-early administration of eculizumab in a child with atypical hemolytic uremic syndrome: a case report.
Dan-Dan GUO ; Yi-Xin XIAO ; Wei-Rui WANG ; Xiao-Lu DENG ; Ye-Hong HUANG
Chinese Journal of Contemporary Pediatrics 2025;27(11):1408-1413
A 10-year-old girl was admitted with a 38-hour history of widespread subcutaneous petechiae and hematuria and a 6-hour history of jaundice and oliguria. Physical examination revealed widespread subcutaneous petechiae and jaundice of the skin and sclera. Laboratory tests showed anemia, thrombocytopenia, acute kidney injury, and markedly elevated lactate dehydrogenase. Thrombotic microangiopathy was initially diagnosed, with a high suspicion of atypical hemolytic uremic syndrome (aHUS). Eculizumab was initiated within 9 hours of admission (within 48 hours of onset). After the first infusion, hemolysis rapidly ceased, and the platelet count and renal function gradually returned to normal. Whole-exome sequencing identified homozygous deletions of CFHR1 exon 2 and CFHR4 exon 1. aHUS typically has abrupt onset and rapid progression. Clinicians should maintain high suspicion for aHUS when the triad of thrombocytopenia, microangiopathic hemolytic anemia, and acute kidney injury is present. Ultra-early eculizumab (within 48 hours of onset) rapidly blocks complement-mediated thrombotic microangiopathy, reverses organ injury, and improves long-term prognosis. Additionally, complement-related genetic testing is important for etiological clarification and individualized determination of eculizumab treatment duration.
Humans
;
Antibodies, Monoclonal, Humanized/administration & dosage*
;
Female
;
Atypical Hemolytic Uremic Syndrome/drug therapy*
;
Child
;
Complement C3b Inactivator Proteins
10.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*

Result Analysis
Print
Save
E-mail