1.Role and mechanism of probiotics in peri-implantitis
Jie WANG ; Rui HUANG ; Ye ZHANG ; Zhaoxi SHOU ; Jie YAO ; Chenxi LIU ; Jian LIAO
Chinese Journal of Tissue Engineering Research 2026;30(4):901-907
BACKGROUND:Studies have found that probiotics have a certain preventive and therapeutic effect on peri-implantitis,and there are further explorations in the mechanism against peri-implantitis.OBJECTIVE:To review the mechanism and clinical application of probiotics in the treatment of peri-implantitis.METHODS:Relevant literature was searched on PubMed,Web of Science,CNKI,and WanFang Data,using the search terms of"probiotics,peri-implantitis,flora imbalance,immunoregulation,inflammatory reaction,mechanism of action"in Chinese and English.A total of 90 articles were finally included.RESULTS AND CONCLUSION:Probiotics have the following mechanisms.They can activate the anti-inflammatory mechanism by inhibiting the secretion of inflammatory factors and promoting the production of anti-inflammatory factors.They can destroy the cell wall of pathogenic bacteria by secreting microbial complexes and bacteriocins,reduce the pH value of biofilms,improve the composition of microorganisms in microecology,induce the change of bacterial community structure,and restore the balance of microbial population around implants.They have immunomodulatory effects and can enhance the resistance of the host oral mucosa to pathogenic bacteria in the surrounding area of the implant.In addition,probiotics can produce antibacterial compounds,offset the adhesion of pathogenic microorganisms,and regulate immune function.Through the above mechanisms,probiotics have certain potential in the adjuvant treatment of peri-implantitis,which can improve the clinical parameters of peri-implantitis and affect the microbiota.Probiotic therapy provides a new treatment option,but more long-term prospective studies are needed to further verify its effect.
2.Role and mechanism of probiotics in peri-implantitis
Jie WANG ; Rui HUANG ; Ye ZHANG ; Zhaoxi SHOU ; Jie YAO ; Chenxi LIU ; Jian LIAO
Chinese Journal of Tissue Engineering Research 2026;30(4):901-907
BACKGROUND:Studies have found that probiotics have a certain preventive and therapeutic effect on peri-implantitis,and there are further explorations in the mechanism against peri-implantitis.OBJECTIVE:To review the mechanism and clinical application of probiotics in the treatment of peri-implantitis.METHODS:Relevant literature was searched on PubMed,Web of Science,CNKI,and WanFang Data,using the search terms of"probiotics,peri-implantitis,flora imbalance,immunoregulation,inflammatory reaction,mechanism of action"in Chinese and English.A total of 90 articles were finally included.RESULTS AND CONCLUSION:Probiotics have the following mechanisms.They can activate the anti-inflammatory mechanism by inhibiting the secretion of inflammatory factors and promoting the production of anti-inflammatory factors.They can destroy the cell wall of pathogenic bacteria by secreting microbial complexes and bacteriocins,reduce the pH value of biofilms,improve the composition of microorganisms in microecology,induce the change of bacterial community structure,and restore the balance of microbial population around implants.They have immunomodulatory effects and can enhance the resistance of the host oral mucosa to pathogenic bacteria in the surrounding area of the implant.In addition,probiotics can produce antibacterial compounds,offset the adhesion of pathogenic microorganisms,and regulate immune function.Through the above mechanisms,probiotics have certain potential in the adjuvant treatment of peri-implantitis,which can improve the clinical parameters of peri-implantitis and affect the microbiota.Probiotic therapy provides a new treatment option,but more long-term prospective studies are needed to further verify its effect.
3.Development and validation of a nomogram model for predicting the risk of H-type hypertension with pulse diagram parameters
Siman WANG ; Mengchu ZHANG ; Minghui YAO ; Tianxiao XIE ; Rui GUO ; Yiqin WANG ; Haixia YAN
Digital Chinese Medicine 2025;8(2):174-182
Objective:
o develop an onset risk prediction nomogram for patients with homocysteine-type (H-type) hypertension (HTH) based on pulse diagram parameters to assist early clinical prediction and diagnosis of HTH.
Methods:
Patients diagnosed with essential hypertension and admitted to Shanghai Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai Hospital of Traditional Chinese Medicine, and Shanghai Hospital of Integrated Traditional Chinese and Western Medicine from July 6th 2020 to June 16th 2021, and from August 11th 2023 to January 22nd 2024, were enrolled in this retrospective research. The baselines and clinical biochemical indicators of patients were collected. The SMART-I TCM pulse instrument was applied to gather pulse diagram parameters. Multivariate logistic regression was adopted to analyze the risk factors for HTH. RStudio was employed to construct the nomogram model, receiver operating characteristic (ROC) curve, and calibration curve (bootstrap self-sampling 200 times), and clinical decision curve were drawn to evaluate the model’s discrimination and clinical effectiveness.
Results:
A total of 168 hospitalized patients with essential hypertension were selected and divided into non-HTH group (n = 29) and HTH group (n = 139). Compared with non-HTH group, HTH group had a lower body mass index (BMI), and higher proportions of male patients and drinkers (P < 0.05). The ventricular wall thickening (VWT) could not be determined. The proportions of left common carotid intima-media wall thickness (LCCIMWT) and serum creatinine (SCR) were higher in HTH group (P < 0.05). The pulse diagram parameter As was significantly higher, and H4/H1 and T1/T were lower in HTH group (P < 0.05). Gender, alcohol consumption, serum creatinine, and the pulse diagram parameter H4/H1 were identified as independent risk factors for HTH (P < 0.05). The nomogram’s area under the ROC curve (AUC) was 0.795 [95% confidence interval (CI): (0.706 6, 0.882 8)], with a specificity of 0.724 and sensitivity of 0.799. After 200 times repeated bootstrap self-samplings, the calibration curve showed that the simulated curve fits well with the actual curve (x2 =
4.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
5.Feasibility study of a domestic fully automated NAT system for blood screening in blood donors
Fenglan YAO ; Rui WANG ; Jinghui HU ; Hongwei GE ; Chan LENG ; Yi ZHA ; Zifu ZHAO ; Zhengmin LIU
Chinese Journal of Blood Transfusion 2025;38(7):941-949
Objective: To validate the analytical performance, operational performance, and process control measures of a domestic fully automatic nucleic acid testing (NAT) system, thereby ensuring an efficient and orderly blood screening workflow. Methods: The concordance rate and sensitivity of WanTag-Vortex Plus system were verified using WHO standard reference panels of HIV-1, HCV and HBV, while precision was assessed using weak positive samples of HIV-1, HCV and HBV. As for its operational performance evaluation, cross-contamination resistance was assessed using strong positive samples, and throughput and stress testing were conducted using negative samples. Reagent stability was verified using weak positive samples, and inter-system performance consistency was assessed using verification panels. In addition, the process control measures were verified using the laboratory quality control demand scale. Results: 1) Verification of concordance rate: The detection results of negative and positive samples of HIV-1, HCV and HBV by WanTag-Vortex Plus system were all consistent with expectations, and the concordance rate was 100%. 2) Precision verification: the repeatability and intermediate precision were extremely high, and the coefficient of variation was less than 5%. 3) Verification of analytical sensitivity: The detection limit of 95% for standard strains of HIV-1, HCV and HBV by WanTag-Vortex Plus system in our laboratory was consistent with the analytical sensitivity provided by reagent manufacturers. 4) Verification of cross-contamination resistance: Five strong positive samples and 87 negative samples were placed according to the actual working conditions and equipment operation design, and the test results were consistent with expectations, with no cross-contamination in the testing system. 5) Throughput and stress testing: Each system completed the individual donor-nucleic acid amplification testing (ID-NAT) of 276 samples in three batches within 12 hours, and successfully completed the ID-NAT test of 828 samples in three consecutive days. 6) Verification of reagent stability: After extreme storage (unsealed storage for 1 week with 4 freeze-thaw cycles), the reagents maintained 100% detection rate in the weak positive samples of HIV-1, HCV, and HBV, showing no significant differences from the control group (Kappa=1). 7) Verification of inter-system performance consistency: The system has stable operation performance, and the performance comparison results across the four devices were consistent (Kappa=1). 8) Process control measures: WanTag-Vortex Plus system software accurately controlled the equipment operation process with strict quality control measures, and correctly interpreted and safely reported the test results. Conclusion: The analytical and operational performance of the WanTag-Vortex Plus system complies with manufacturer design standards and essential laboratory workflow requirements. Integrated with laboratory information system (LIS), the system's control software meets standard process control requirements, yet requires further improvement.
6.Construction and application of the "Huaxi Hongyi" large medical model
Rui SHI ; Bing ZHENG ; Xun YAO ; Hao YANG ; Xuchen YANG ; Siyuan ZHANG ; Zhenwu WANG ; Dongfeng LIU ; Jing DONG ; Jiaxi XIE ; Hu MA ; Zhiyang HE ; Cheng JIANG ; Feng QIAO ; Fengming LUO ; Jin HUANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):587-593
Objective To construct large medical model named by "Huaxi HongYi"and explore its application effectiveness in assisting medical record generation. Methods By the way of a full-chain medical large model construction paradigm of "data annotation - model training - scenario incubation", through strategies such as multimodal data fusion, domain adaptation training, and localization of hardware adaptation, "Huaxi HongYi" with 72 billion parameters was constructed. Combined with technologies such as speech recognition, knowledge graphs, and reinforcement learning, an application system for assisting in the generation of medical records was developed. Results Taking the assisted generation of discharge records as an example, in the pilot department, after using the application system, the average completion times of writing a medical records shortened (21 min vs. 5 min) with efficiency increased by 3.2 time, the accuracy rate of the model output reached 92.4%. Conclusion It is feasible for medical institutions to build independently controllable medical large models and incubate various applications based on these models, providing a reference pathway for artificial intelligence development in similar institutions.
7.Clinical efficacy of single branch stent-graft treatment for retrograde type A intramural hematoma: A retrospective cohort study
Bailang CHEN ; Zanxin WANG ; Xianmian ZHUANG ; Haibing LIU ; Yao CHEN ; Rui ZHANG ; Minxin WEI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1166-1172
Objective To explore the efficacy of using a single branch stent-graft to treat primary intramural hematoma located at the distal arch or descending aorta in Stanford A type aortic intramural hematoma. Methods From July 2020 to November 2022, 10 patients with primary intramural hematoma of Stanford A type aortic intramural hematoma were treated with endovascular repair using a single branch stent-graft in the Department of Cardiovascular Surgery at The University of Hong Kong-Shenzhen Hospital. There were 9 males and 1 female, aged from 32 to 66 years, with a mean age of (47.0±10.4) years. All patients had intramural hematoma involving the ascending aorta and aortic arch, diagnosed as type A intramural hematoma, with the tear located in the descending aorta. Among them, 6 patients were complicated by ulceration of the descending aorta with intramural hematoma, and 4 patients had changes of the descending aortic dissection. All patients underwent endovascular stent repair, with 8 patients undergoing emergency surgery (≤14 days) and 2 patients undergoing subacute surgery (15 days to 3 months). Results There were no neurological complications, paraplegia, stent fracture or displacement, or limb or visceral ischemia during the perioperative period in all patients. One patient had continuous chest pain after surgery, and the stent had a new tear at the proximal end, requiring ascending aorta and partial arch replacement. As of the latest follow-up, all patients had obvious absorption or complete absorption of the intramural hematoma in the ascending aorta and aortic arch compared with before the operation. Conclusion Single branch stent-graft treatment of retrograde ascending aortic intramural hematoma is safe and effective, with good short-term results.
8.Comparison of chemical constituents in traditional decoction and formula granule decoction of Wendan Decoction
Tan XUE ; Man-wen XU ; Xue-hua FAN ; Feng-yu DONG ; Yan MIAO ; Jia-ning SUN ; Jun-han SHI ; Lu ZHANG ; Jing YAO ; Rui-xin LIU
Chinese Traditional Patent Medicine 2025;47(2):384-394
AIM To compare the chemical constituents in traditional decoction and formula granule decoction of classical famous prescription Wendan Decoction.METHODS The HPLC fingerprints were established,after which the contents of adenosine,synephrine,liquiritin,naringin,hesperidin,6-gingerol and adenosine cyclophosphate were determined,cluster analysis,principal component analysis and multidimensional scaling analysis were adopted in the investigation of component differences,and the equivalent of formula granules was adjusted.RESULTS The similarities of HPLC fingerprints for 10 batches of traditional decoctions were higher than those of HPLC fingerprints for 9 batches of formula granule decoctions(P<0.01).Adenosine,synephrine,liquiritin,hesperidin and cyclic adenosine monophosphate demonstrated higher contents in traditional decoctions than those in formula granule decoctions(P<0.05),6-gingerol displayed lower content than that in the latter produced by manufacturers A,C(P<0.05),which was higher than that in the latter produced by manufacturer B(P<0.01).Various batches of traditional decoctions and formula granule decoctions could be obviously distinguished,adenosine,synephrine and hesperidin exhibited great influences on the classification of principal component analysis,and the quality of formula granule decoctions produced by manufacturer C was closer to that of traditional decoctions.After equivalent correction,the contents of various constituents in formula granule decoctions produced by manufacturers A,C showed no significant differences as compared with those in traditional decoction(P>0.05).CONCLUSION The formula granules of Wendan Decoction from different manufacturers exist quality differences,so the preparation process and extraction process of this preparation should be optimized to improve quality,and equivalent ratio should be adjusted according to actual requirements to ensure its scientific and rational clinical application.
9.Epidemiological analysis of imported malaria in Yunnan Province,2020-2023
Chun-li DING ; Yao-wu ZHOU ; Zu-rui LIN ; Xiao-dong SUN ; Chun WEI ; Jian-wei XU ; Ya-ming YANG
Chinese Journal of Zoonoses 2025;41(2):193-199
This study analyzed the epidemiological characteristics of imported malaria in Yunnan Province from 2020 to 2023,to provide scientific evidence for formulating measures to decrease imported malaria and prevent re-establishment of malaria transmission.Malaria data reported by the China Disease Prevention and Control Information System were analyzed to determine parasite species;sources of infection;temporal,spatial,and population distributions;and importation routes.A total of 828 malaria cases were reported in the province.Plasmodium vivax and Plasmodium falciparum accounted for 89.98%and 8.33%of cases,respectively.A total of 47.58%of cases were imported from Myanmar,and all P.falciparum malaria ca-ses were from Africa.Thirteen(81.25%)prefectures or municipalities reported malaria,among which Dehong,Baoshan,Kunming,and Lincang reported 94.32%of cases.A total of 52.54%of cases were in young men.The proportion of cross-bor-der personnel flow,land input,and aircraft input were 88.89%and 11.11%respectively.A total of 98.19%of patients sought medical care within 7 days after fever onset,and 82.85%initiated diagnosis for malaria,and 84.90%of diagnoses were con-firmed by health facilities at or below the county level.Imported malaria is a major challenge in preventing re-establishment of transmission in Yunnan.Most imported cases involved cross-border malaria transmission of mainly Plasmodium vivax between China and Myanmar.To achieve malaria elimination,vigilance of health staff in malaria diagnosis and treatment should be pro-moted,and intensive malaria health education should be provided to people traveling to malaria endemic territories,to enable individual protection,and timely diagnosis and treatment after return from endemic countries.
10.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]

Result Analysis
Print
Save
E-mail