1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Characterization of Yersinia enterocolitis in patients with diarrhea in a district of Beijing
Yu-wei LIU ; Hai-rui WANG ; Yan-chun ZHANG ; Shou-fei LI ; Luo-tong WANG ; Miao WANG ; Ai-xia YAN ; Ying LI ; Mao-jun ZHANG
Chinese Journal of Zoonoses 2025;41(6):609-616
This study was aimed at providing basic data for the control and prevention of Yersinia enterocolitica(Ye)infections.Ye isolates from stool samples collected from patients with diarrhea in a Beijing district between January 2019 and June 2024 were studied.Basic patient information and stool samples were collected,and quantitative polymerase chain reaction(qPCR)was applied to enriched cultures.Further analyses included virulence gene detection,whole-genome sequencing,and drug resistance detection.The detection rate of Ye was 0.76%(11/1 439),according to culture methods,thus yielding 12 Ye strains from distinct patients:11 isolated during the study period and 1 from 2017.The 12 Ye positive patients were 6-41 years of age,and their clinical presentations predominantly featured watery stools(66.67%,8/12)and loose stools(33.33%,4/12).The frequencies of nausea,vomiting,and fever were 41.67%(5/12),41.67%(5/12),and 8.33%(1/12),respectively.The drug resistance rates of Ye to TET,AMP,and NAL were 50.00%(6/12),33.33%(4/12),and 25.00%(3/12),respectively.One Ye strain exhibited multidrug resistance to ETP,MEM,TET,CIP,NAL,and AMP.According to qPCR detection of five common virulence genes,two Ye strains were identified as ystA+/ystB-type(ystA+/ystB-/ail+/yadA+/virF+),whereas ten strains were identified as ystA-/ystB+type(ystA-/ystB+/ail-/yadA-/virF-).VFDB database analysis based on genome sequences indicated that 12 Ye strains carried an average of 11 key virulence genes associated with adhesion,invasion,protease activity,and flagellar movement,and predicted 106 virulence genes and 12 virulence gene profiles.Only the two ystA+/ystB-Ye strains contained elements related to the TTSS and ABC transporter function.Detection of ystA-/ystB+Ye in stool isolation and culture of diarrhea cases might potentially have been missed in some cases,thus highlighting the importance of fluorescence PCR screening of fecal growth solutions to enhance isolation efficiency.Moreover,our findings revealed the genetic diversity of Ye isolated from diarrhea cases,thereby indicating the presence of multiple types of virulence genes within this pathogen.
4.Granulocyte colony-stimulating factor in neutropenia management after CAR-T cell therapy: A safety and efficacy evaluation in refractory/relapsed B-cell acute lymphoblastic leukemia.
Xinping CAO ; Meng ZHANG ; Ruiting GUO ; Xiaomei ZHANG ; Rui SUN ; Xia XIAO ; Xue BAI ; Cuicui LYU ; Yedi PU ; Juanxia MENG ; Huan ZHANG ; Haibo ZHU ; Pengjiang LIU ; Zhao WANG ; Yu ZHANG ; Wenyi LU ; Hairong LYU ; Mingfeng ZHAO
Chinese Medical Journal 2025;138(1):111-113
5.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
6.Quality evaluation of Bidentis Herba derived from different original plants based on HPLC fingerprints, characteristic chromatograms, multi-component content determination combined with chemical pattern recognition.
Guo-Li SHI ; Yun MA ; Feng-Xia SHEN ; Han-Wen DU ; Cong-Min LIU ; Rui-Xia WEI ; Yan-Fang LI ; Jian-Wei FAN ; Yong-Xia GUAN
China Journal of Chinese Materia Medica 2025;50(15):4284-4292
This study established the HPLC fingerprints, characteristic chromatograms, and a multi-component content determination method for Bidens bipinnata and B. biternata. The chemical pattern recognition analysis was then employed to clarify the characteristic indexes of quality differences between the two original plants of Bidentis Herba, providing a reference for establishing the quality standards of Bidentis Herba. HPLC was launched on an Agilent Poroshell 120 EC-C_(18) chromatographic column(4.6 mm×250 mm, 4 μm) by gradient elution with a mobile phase of 0.1% aqueous phosphoric acid-acetonitrile at a flow rate of 0.7 mL·min~(-1), detection wavelength of 270 nm, column temperature of 25 ℃, and an injection volume of 5 μL. The similarity between the fingerprints of 18 batches of Bidentis Herba samples and the common pattern(R) ranged from 0.572 to 0.933. A total of 23 chromatographic peaks were calibrated. Through comparison with the reference substances, six components(neochlorogenic acid, chlorogenic acid, isochlorogenic acid A, isochlorogenic acid B, rutin, and hyperoside) were identified and subjected to quantitative analysis. The characteristic fingerprints of B. bipinnata and B. biternata were calibrated with 20 and 17 characteristic peaks, respectively. Among them, peaks 8, 9, 22, and 23 were the characteristic peaks of B. bipinnata, and peak 7 was the characteristic peak of B. biternata, which can be used to distinguish the two original plants of Bidentis Herba. The relative standard deviation of the content of the above-mentioned six components ranged from 36% to 123%. The cluster analysis, principal component analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) classified the 18 batches of Bidentis Herba samples into two categories. Additionally, through the analysis of variable importance in projection(VIP) under OPLS-DA, three characteristic indexes, rutin, isochlorogenic acid A, and isochlorogenic acid B, were identified. The analytical method established in this study can comprehensively evaluate the consistency of Bidentis Herba samples derived from different original plants, specifically identify the differential components between them, and effectively distinguish the two original plants of Bidentis Herba, providing a basis for the differentiation between different original plants and the quality control of Bidentis Herba.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Bidens/chemistry*
7.Association between ABO Blood Types and the Risk of Gestational Diabetes Mellitus: A Prospective Cohort Study.
Shuang Hua XIE ; Shuang Ying LI ; Shao Fei SU ; En Jie ZHANG ; Shen GAO ; Yue ZHANG ; Jian Hui LIU ; Min Hui HU ; Rui Xia LIU ; Wen Tao YUE ; Cheng Hong YIN
Biomedical and Environmental Sciences 2025;38(6):678-692
OBJECTIVE:
To investigate the association between ABO blood types and gestational diabetes mellitus (GDM) risk.
METHODS:
A prospective birth cohort study was conducted. ABO blood types were determined using the slide method. GDM diagnosis was based on a 75-g, 2-h oral glucose tolerance test (OGTT) according to the criteria of the International Association of Diabetes and Pregnancy Study Groups. Logistic regression was applied to calculate the odds ratios ( ORs) and 95% confidence intervals ( CIs) between ABO blood types and GDM risk.
RESULTS:
A total of 30,740 pregnant women with a mean age of 31.81 years were enrolled in this study. The ABO blood types distribution was: type O (30.99%), type A (26.58%), type B (32.20%), and type AB (10.23%). GDM was identified in 14.44% of participants. Using blood type O as a reference, GDM risk was not significantly higher for types A ( OR = 1.05) or B ( OR = 1.04). However, women with type AB had a 19% increased risk of GDM ( OR = 1.19, 95% CI = 1.05-1.34; P < 0.05), even after adjusting for various factors. This increased risk for type AB was consistent across subgroup and sensitivity analyses.
CONCLUSION
The ABO blood types may influence GDM risk, with type AB associated with a higher risk. Incorporating it-either as a single risk factor or in combination with other known factors-could help identify individuals at risk for GDM before or during early pregnancy.
Humans
;
Female
;
Pregnancy
;
Diabetes, Gestational/etiology*
;
ABO Blood-Group System
;
Adult
;
Prospective Studies
;
Risk Factors
;
Young Adult
8.Development of Benchtop Low-Field Nuclear Magnetic Resonance Technology and Its Application in Drug Control Field
Qi LIAO ; Yong-Hong LIU ; Ying JIAO ; Xiao-Ying YANG ; Yi-Hua YANG ; Cui-Mei LIU ; Rui-Xia GAO
Journal of Forensic Medicine 2025;41(3):267-276
At present,the drug substitutes represented by new psychoactive substances are gradually be-coming popular,leading to an increasing demand for identifying novel drugs with unknown structures in drug investigation.Nuclear magnetic resonance(NMR)spectroscopy is an important tool for ana-lyzing molecular structures.In the absence of standard substances,quantitative NMR(qNMR)can un-dertake the quantitative analysis of target substances in complex mixtures and has unique advantages in the research of new drugs and their precursor drugs.Due to the limitations of the site and mainte-nance costs,as well as relatively complex operation,high-field superconducting NMR is less com-monly applied in drug research.The desktop low-field NMR developed in recent years provides a new alternative solution.Due to the use of permanent magnets,its size is reduced,and the operation and maintenance costs are lowered.It has been widely used in various research fields.This article reviews the development of low-field NMR technology,summarizes the application of desktop low-field NMR in screening and identification of suspicious substances,rapid content determination,analysis of drug manufacturing processes and synthetic routes,and correlation traceability.It also looks forward to the prospects and development directions of this technology in drug research,aiming to provide a reference for researchers who work in analytical chemistry and drug research.
9.Predictive analysis of NLR and TNF-α level for the efficacy of TACE combined with microwave ablation therapy in patients with massive liver cancer
Hui XING ; Ying TAN ; Xiuzhen WANG ; Rui LI ; Xia LIU
Journal of International Oncology 2025;52(2):101-106
Objective:To explore the predictive value of neutrophil-to-lymphocyte ratio (NLR) and tumor necrosis factor -α (TNF-α) level on the therapeutic effect of transcatheter arterial chemoembolization (TACE) combined with microwave ablation in patients with massive liver cancer.Methods:The medical records of 106 patients with massive liver cancer who underwent TACE combined with microwave ablation treatment in the Affiliated Hospital of Weifang Medical University from February 2020 to February 2023 were retrospectively analyzed. The efficacy was evaluated 6 weeks after surgery, and the patients were divided into remission group and non-remission group according to the therapeutic effect. The levels of NLR and TNF-α in the two groups were detected before surgery, 3 days after surgery and 7 days after surgery. Point two column correlation was used to analyze the relationship between the levels of NLR and TNF-α in different time periods and the therapeutic effect of TACE combined with microwave ablation in patients with massive liver cancer. The receiver operator characteristic (ROC) curve was drawn to analyze the predictive value of NLR and TNF-α levels in different time periods for the therapeutic effect of TACE combined with microwave ablation in patients with massive liver cancer.Results:Six weeks after surgery, out of 106 patients with massive liver cancer, 13 achieved complete remission, 48 achieved partial remission, 20 experienced disease progression, and 25 remained stable. The overall remission rate was 57.55% (61/106). Before surgery, the levels of NLR [ (2.26±0.13) vs. (2.43±0.12), t=6.87, P<0.001] and TNF-α [ (36.20±4.38) pg/ml vs. (42.74±5.74) pg/ml, t=6.66, P<0.001] in the remission group ( n=61) were lower than those in the non-remission group ( n=45), with statistically significant differences. At 3 days after surgery, there were no statistically significant difference in the levels of NLR [ (6.16±3.22) vs. (6.22±3.30), t=0.09, P=0.925] or TNF-α [ (48.84±7.22) pg/ml vs. (49.13±7.34) pg/ml, t=0.20, P=0.840] between the remission group and the non-remission group. At 7 days after surgery, the levels of NLR [ (2.60±0.18) vs. (2.82±0.26), t=5.15, P<0.001] and TNF-α [ (38.20±6.30) pg/ml vs. (45.57±5.79) pg/ml, t=6.16, P<0.001] in the remission group were lower than those in the non-remission group, with statistically significant differences. There were statistically significant differences in NLR and TNF-α levels before surgery, 3 days and 7 days after surgery between the remission group and the non-remission group ( F=82.43, P<0.001; F=54.45, P<0.001; F=76.23, P<0.001; F=15.61, P<0.001). Further pair-to-pair comparison showed that the levels of NLR and TNF-α were higher in both groups 3 and 7 days after surgery than before surgery, but the levels of NLR and TNF-α were lower in both groups 7 days after surgery than 3 days after surgery, with statistically significant differences (all P<0.005). Point two column correlation analysis showed that NLR level, TNF-α level and the efficacy of TACE combined with microwave ablation in patients with massive liver cancer were significantly positively correlated before and 7 days after surgery ( r=0.42, P<0.001; r=0.49, P<0.001; r=0.43, P<0.001; r=0.46, P<0.001). ROC curve showed that the area under the curve (AUC) of NLR and TNF-α alone in predicting the efficacy of TACE combined with microwave ablation in patients with massive liver cancer before and 7 days after surgery was 0.750 (95% CI: 0.656-0.844), 0.788 (95% CI: 0.699-0.877), 0.751 (95% CI: 0.652-0.850), 0.788 (95% CI: 0.700-0.876), respectively. The AUC of combined prediction of NLR and TNF-α before and 7 days after surgery were 0.818 (95% CI: 0.736-0.900) and 0.813 (95% CI: 0.730-0.897), respectively. There were no statistically significant differences in the AUC values of NLR and TNF-α alone or in combination for predicting the therapeutic effect of TACE combined with microwave ablation in patients with massive liver cancer before and 7 days after surgery (all P>0.05) . Conclusions:The levels of NLR and TNF-α before and 7 days after surgery are related to the effect of TACE combined with microwave ablation in patients with massive liver cancer, and the combination of NLR and TNF-α levels before and 7 days after surgery has certain value in predicting the effect of TACE combined with microwave ablation in patients with massive liver cancer.
10.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.

Result Analysis
Print
Save
E-mail