1.Interpretation of 2024 ESC guidelines for the management of elevated blood pressure and hypertension
Yu CHENG ; Yiheng ZHOU ; Yao LÜ ; ; Dongze LI ; Lidi LIU ; Peng ZHANG ; Rong YANG ; Yu JIA ; Rui ZENG ; Zhi WAN ; Xiaoyang LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):31-40
The European Society of Cardiology (ESC) released the "2024 ESC guidelines for the management of elevated blood pressure and hypertension" on August 30, 2024. This guideline updates the 2018 "Guidelines for the management of arterial hypertension." One notable update is the introduction of the concept of "elevated blood pressure" (120-139/70-89 mm Hg). Additionally, a new systolic blood pressure target range of 120-129 mm Hg has been proposed for most patients receiving antihypertensive treatment. The guideline also includes numerous additions or revisions in areas such as non-pharmacological interventions and device-based treatments for hypertension. This article interprets the guideline's recommendations on definition and classification of elevated blood pressure and hypertension, and cardiovascular disease risk assessment, diagnosing hypertension and investigating underlying causes, preventing and treating elevated blood pressure and hypertension. We provide a comparison interpretation with the 2018 "Guidelines for the management of arterial hypertension" and the "2017 ACC/AHA guideline on the prevention, detection, evaluation, and management of high blood pressure in adults."
2.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
3.Evaluation Value of Blood Biomarker Tests for Efficacy of EGFR-TKI in Advanced NSCLC Treatment
Rui FAN ; Yonghui WU ; Zhan GU ; Yanbin PENG ; Lixin WANG
Cancer Research on Prevention and Treatment 2025;52(5):382-387
Objective To analyze the levels of serum CTCs and ctDNA in NSCLC patients receiving first-line EGFR-TKI treatment, and to explore the clinical value of CTCs and ctDNA detection in assessing the efficacy of treatment for advanced lung cancer. Methods A total of 109 NSCLC patients receiving first-line EGFR-TKI treatment were enrolled. Serum tumor markers CEA, CTCs, and ctDNA were detected at baseline and after one month of treatment. Chest CT scans were performed, and treatment efficacy was evaluated based on RECIST1.1 criteria. CTCs were counted by enrichment-staining-computational algorithm to analyze malignant features, while ctDNA was assessed using digital PCR. Results Survival rate was low in patients with abnormal CEA and ctDNA tests at baseline and in patients with reduced serum CTCs after treatment. In the SD subgroup of patients with brain metastases and advanced stage, the PFS benefit was low. Conclusion Patients in the SD subgroup have significantly higher recurrence risks than those in the PR or CR subgroups. Therefore, CTC and ctDNA testing should be applied to patients in the SD subgroup to identify high-risk patients with poor response to EGFR-TKI treatment, intervene with additional treatment promptly, and obtain long progression-free survival.
4.Characteristic volatile organic compounds in exhaled breath of coal workers' pneumoconiosis patients by thermal desorption gas chromatography-mass spectrometry
Yazhen HE ; Chunguang DING ; Junyun WANG ; Yuzhen FENG ; Fangda PENG ; Gaisheng LIU ; Fan YANG ; Chunmin ZHANG ; Rui GAO ; Qingyu MENG ; Zhijun WU ; Jingguang FAN
Journal of Environmental and Occupational Medicine 2025;42(5):571-577
Background Coal workers' pneumoconiosis is a serious occupational disease in China. Exhaled volatile organic compounds (VOCs) can serve as the "breath fingerprint" of internal pathological processes, which provides a theoretical basis for exhaled VOCs to be used as potential non-invasive biomarkers for early diagnosis of coal workers' pneumoconiosis. Objective To screen out the characteristic VOCs and important characteristic VOCs of exhaled air in patients with coal workers' pneumoconiosis, and to explore the potential of these VOCs as biomarkers for early non-invasive diagnosis of the disease. Methods In this study, 27 VOCs in the exhaled breath of 22 patients with stage I coal workers' pneumoconiosis, 77 workers exposed to dust, and 92 healthy controls were quantitatively detected by thermal desorption gas chromatography-mass spectrometry (TD-GC-MS). Substances with P<0.05 in univariate analysis and variable importance projection (VIP) >1 in supervised orthogonal partial least squares discriminant analysis (OPLS-DA) model were selected as the characteristic VOCs for early diagnosis of coal workers' pneumoconiosis. Age was included in the LASSO regression model as a covariate to screen out important characteristic VOCs, and the diagnostic performance was evaluated by receiver operating characteristic (ROC) curve. Spearman correlation was further used to explore the correlation between important characteristic VOCs and clinical lung function indicators. Results Through univariate analysis and OPLS-DA modeling, 8 VOCs were selected, including 2-methylpentane, 3-methylpentane, n-hexane, methylcyclopentane, n-heptane, methylcyclohexane, 4-methyl-2-pentanone, and 2-hexanone, in exhaled breath of patients with coal workers' pneumoconiosis. The concentrations of 4 VOCs, including 3-methylpentane, n-hexane, 4-methyl-2-pentanone, and 2-hexanone, showed a decreasing trend with the increase of dust exposure years. By LASSO regression, the important characteristic VOCs of the coal workers' pneumoconiosis group and the dust exposure group were n-hexane, methylcyclohexane and 4-methyl-2-pentanone, and the important characteristic VOCs of the coal workers' pneumoconiosis group and the healthy group were 2-methyl-pentane and 4-methyl-2-pentanone. The ROC analysis showed that the area under the curve (AUC) of n-hexane, methylcyclohexane, and 4-methyl-2-pentanone were 0.969, 0.909, and 0.956, respectively, and the AUC of combined diagnosis was 0.988 and its Youden index was 0.961, suggesting that these results can serve as a valuable reference for further research on early diagnosis. The Correlation analysis found that there was a positive correlation between n-hexane and lung function indicators in the important characteristic VOCs, indicating that it could indirectly reflect the obstruction of lung function ventilation, further proving that important characteristic VOCs have the potential to monitor lung function decline. Conclusion Three important characteristic VOCs selected in this study have the potential to be used as non-invasive biomarkers for early diagnosis and disease monitoring of coal workers' pneumoconiosis, and are worthy of further study and verification.
5.Construction and Application Evaluation of an Integrated Traditional Chinese and Western Medicine Risk Prediction Model for Readmission in Patients with Stable Angina of Coronary Heart Disease:A Prospective Study Based on Real-World Clinical Data
Wenjie HAN ; Mingjun ZHU ; Xinlu WANG ; Rui YU ; Guangcao PENG ; Qifei ZHAO ; Jianru WANG ; Shanshan NIE ; Yongxia WANG ; Jingjing WEI
Journal of Traditional Chinese Medicine 2025;66(6):604-611
ObjectiveBy exploring the influencing factors of readmission in patients with stable angina of coronary heart disease (CHD) based on real-world clinical data, to establish a risk prediction model of integrated traditional Chinese and western medicine, in order to provide a basis for early identification of high-risk populations and reducing readmission rates. MethodsA prospective clinical study was conducted involving patients with stable angina pectoris of CHD, who were divided into a training set and a validation set at a 7∶3 ratio. General information, traditional Chinese medicine (TCM)-related data, and laboratory test results were uniformly collected. After a one-year follow-up, patients were classified into a readmission group and a non-readmission group based on whether they were readmitted. Univariate and multivariate logistic regression analyses were performed to identify independent risk factors for readmission. A risk prediction model of integrated traditional Chinese and western medicine was constructed and visualized using a nomogram. The model was validated and evaluated in terms of discrimination, calibration, and clinical decision curve analysis. ResultsA total of 682 patients were included, with 477 in the training set and 205 in the validation set, among whom 89 patients were readmitted. Multivariate logistic regression analysis identified heart failure history [OR = 6.93, 95% CI (1.58, 30.45)], wiry pulse [OR = 2.58, 95% CI (1.42, 4.72)], weak pulse [OR = 3.97, 95% CI (2.06, 7.67)], teeth-marked tongue [OR = 4.38, 95% CI (2.32, 8.27)], blood stasis constitution [OR = 2.17, 95% CI (1.06, 4.44)], phlegm-stasis mutual syndrome [OR = 3.64, 95% CI (1.87, 7.09)], and elevated non-high-density lipoprotein cholesterol [OR = 1.30, 95% CI (1.01, 1.69)] as influencing factors of readmission. These factors were used as predictors to construct a nomogram-based risk prediction model for readmission in patients with stable angina. The model demonstrated moderate predictive capability, with an area under the receiver operating characteristic curve (AUC) of 0.818 [95% CI (0.781, 0.852)] in the training set and 0.816 [95% CI (0.779, 0.850)] in the validation set. The Hosmer-Lemeshow test showed good calibration (χ² = 4.55, P = 0.80), and the model's predictive ability was stable. When the threshold probability exceeded 5%, the clinical net benefit of using the model to predict readmission risk was significantly higher than intervening in all patients. ConclusionHistory of heart failure, teeth-marked tongue, weak pulse, wiry pulse, phlegm-stasis mutual syndrome, blood stasis constitution, and non-high-density lipoprotein cholesterol are influencing factors for readmission in patients with stable angina of CHD. A clinical prediction model was developed based on these factors, which showed good discrimination, calibration, and clinical utility, providing a scientific basis for predicting readmission events in patients with stable angina.
6.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
7.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
8.Research Progress on Obesity-Associated Kidney Diseases.
Rui-Feng YANG ; Wen WU ; Peng ZHANG
Acta Academiae Medicinae Sinicae 2025;47(1):77-85
The pathogenesis of obesity-associated kidney disease (OAKD) involves many aspects,including the overactivation of the renin-angiotensin-aldosterone system,insulin resistance,chronic inflammation,disorder of lipid metabolism and imbalance of gut microecology.Treatment strategies for OAKD focus on lifestyle adjustments,pharmacotherapy,bariatric surgery,and fecal microbiota transplantation.A deeper understanding of the hazards of OAKD and its pathogenesis will contribute to the development of personalized and precise strategies for prevention,diagnosis and treatment of OAKD in the future.
Humans
;
Obesity/complications*
;
Kidney Diseases/therapy*
;
Renin-Angiotensin System
;
Insulin Resistance
9.Effects of MTHFR and GGH gene polymorphisms on plasma concentrations and toxicity following high-dose methotrexate therapy in children with acute lymphoblastic leukemia.
Lin-Xiao TENG ; Qi AN ; Lei WANG ; Nan WANG ; Qing-Ling KONG ; Rui HAN ; Yuan WANG ; Lu LIU ; Yan WANG ; Shu-Mei XU ; Kun-Peng SHI ; Fang-Shan QIU ; Xi-Xi DU ; Jin-Rui SHI
Chinese Journal of Contemporary Pediatrics 2025;27(7):802-807
OBJECTIVES:
To investigate the effects of methylenetetrahydrofolate reductase (MTHFR) rs1801133 and γ-glutamyl hydrolase (GGH) rs11545078 gene polymorphisms on plasma concentrations and toxicity following high-dose methotrexate (MTX) therapy in children with acute lymphoblastic leukemia (ALL).
METHODS:
Children with ALL treated at the Xuzhou Children's Hospital of Xuzhou Medical University from January 2021 to April 2024 were selected for this study. Genotypes of MTHFR rs1801133 and GGH rs11545078 were determined using multiplex polymerase chain reaction. MTX plasma concentrations were measured by enzyme-multiplied immunoassay technique, and toxicity was graded according to the Common Terminology Criteria for Adverse Events version 5.0. The relationships between MTHFR rs1801133 and GGH rs11545078 genotypes and both MTX plasma concentrations and associated toxicities were analyzed.
RESULTS:
In the low-risk ALL group, the MTHFR rs1801133 genotype was associated with increased MTX plasma concentrations at 72 hours (P<0.05). In the intermediate- to high-risk group, the MTHFR rs1801133 genotype was associated with increased MTX plasma concentrations at 48 hours (P<0.05), and the GGH rs11545078 genotype was associated with increased MTX plasma concentrations at 48 hours (P<0.05). In the intermediate- to high-risk group, the MTHFR rs1801133 genotype was associated with the occurrence of reduced hemoglobin (P<0.05), and the GGH rs11545078 genotype was associated with the occurrence of thrombocytopenia (P<0.05).
CONCLUSIONS
Detection of MTHFR rs1801133 and GGH rs11545078 genotypes can be used to predict increased MTX plasma concentrations and the occurrence of toxic reactions in high-dose MTX treatment of ALL, enabling timely interventions to enhance safety.
Humans
;
Methotrexate/toxicity*
;
Methylenetetrahydrofolate Reductase (NADPH2)/genetics*
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/blood*
;
Male
;
Female
;
Child
;
Child, Preschool
;
gamma-Glutamyl Hydrolase/genetics*
;
Antimetabolites, Antineoplastic/adverse effects*
;
Infant
;
Polymorphism, Genetic
;
Adolescent
;
Genotype
;
Polymorphism, Single Nucleotide
10.Chain mediating role of family care and emotional management between social support and anxiety in primary school students.
Zhan-Wen LI ; Jian-Hui WEI ; Ke-Bin CHEN ; Xiao-Rui RUAN ; Yu-Ting WEN ; Cheng-Lu ZHOU ; Jia-Peng TANG ; Ting-Ting WANG ; Ya-Qing TAN ; Jia-Bi QIN
Chinese Journal of Contemporary Pediatrics 2025;27(10):1176-1184
OBJECTIVES:
To investigate the chain mediating role of family care and emotional management in the relationship between social support and anxiety among rural primary school students.
METHODS:
A questionnaire survey was conducted among students in grades 4 to 6 from four counties in Hunan Province. Data were collected using the Social Support Rating Scale, Family Care Index Scale, Emotional Intelligence Scale, and Generalized Anxiety Disorder -7. Logistic regression analysis was used to explore the influencing factors of anxiety symptoms. Mediation analysis was conducted to assess the chain mediating effects of family care and emotional management between social support and anxiety.
RESULTS:
A total of 4 141 questionnaires were distributed, with 3 874 valid responses (effective response rate: 93.55%). The prevalence rate of anxiety symptoms among these students was 9.32% (95%CI: 8.40%-10.23%). Significant differences were observed in the prevalence rates of anxiety symptoms among groups with different levels of social support, family functioning, and emotional management ability (P<0.05). The total indirect effect of social support on anxiety symptoms via family care and emotional management was significant (β=-0.137, 95%CI: -0.167 to -0.109), and the direct effect of social support on anxiety symptoms remained significant (P<0.05). Family care and emotional management served as significant chain mediators in the relationship between social support and anxiety symptoms (β=-0.025,95%CI:-0.032 to -0.018), accounting for 14.5% of the total effect.
CONCLUSIONS
Social support can directly affect anxiety symptoms among rural primary school students and can also indirectly influence anxiety symptoms through the chain mediating effects of family care and emotional management. These findings provide scientific evidence for the prevention of anxiety in primary school students from multiple perspectives.
Humans
;
Female
;
Male
;
Social Support
;
Anxiety/etiology*
;
Child
;
Students/psychology*
;
Emotions
;
Logistic Models

Result Analysis
Print
Save
E-mail