1.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
2.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
8.Biomarkers of hepatotoxicity in rats induced by aqueous extract of Dictamni Cortex based on urine metabolomics.
Hui-Juan SUN ; Rui GAO ; Meng-Meng ZHANG ; Ge-Yu DENG ; Lin HUANG ; Zhen-Dong ZHANG ; Yu WANG ; Fang LU ; Shu-Min LIU
China Journal of Chinese Materia Medica 2025;50(9):2526-2538
This paper aimed to use non-targeted urine metabolomics to reveal the potential biomarkers of toxicity in rats with hepatic injury induced by aqueous extracts of Dictamni Cortex(ADC). Forty-eight SD rats were randomly assigned to a blank group and high-dose, medium-dose, and low-dose ADC groups, with 12 rats in each group(half male and half female), and they were administered orally for four weeks. The hepatic injury in SD rats was assessed by body weight, liver weight/index, biochemical index, L-glutathione(GSH), malondialdehyde(MDA), and pathological alterations. The qPCR was utilized to determine the expression of metabolic enzymes in the liver and inflammatory factors. Differential metabolites were screened using principal component analysis(PCA) and partial least squares-discriminant analysis(PLS-DA), followed by a metabolic pathway analysis. The Mantel test was performed to assess differential metabolites and abnormally expressed biochemical indexes, obtaining potential biomarkers. The high-dose ADC group showed a decrease in body weight and an increase in liver weight and index, resulting in hepatic inflammatory cell infiltration and hepatic steatosis. In addition, this group showed elevated levels of MDA, cytochrome P450(CYP) 3A1, interleukin-1β(IL-1β), and tumor necrosis factor-α(TNF-α), as well as lower levels of alanine transaminase(ALT) and GSH. A total of 76 differential metabolites were screened from the blank and high-dose ADC groups, which were mainly involved in the pentose phosphate pathway, tryptophan metabolism, purine metabolism, pentose and glucuronic acid interconversion, galactose metabolism, glutathione metabolism, and other pathways. The Mantel test identified biomarkers of hepatotoxicity induced by ADC in SD rats, including glycineamideribotide, dIDP, and galactosylglycerol. In summary, ADC induced hepatotoxicity by disrupting glucose metabolism, ferroptosis, purine metabolism, and other pathways in rats, and glycineamideribotide, dIDP, and galactosylglycerol could be employed as the biomarkers of its toxicity.
Animals
;
Male
;
Rats, Sprague-Dawley
;
Rats
;
Metabolomics
;
Biomarkers/metabolism*
;
Liver/metabolism*
;
Drugs, Chinese Herbal/adverse effects*
;
Female
;
Chemical and Drug Induced Liver Injury/metabolism*
;
Glutathione/metabolism*
;
Humans
9.Quercetin Confers Protection against Sepsis-Related Acute Respiratory Distress Syndrome by Suppressing ROS/p38 MAPK Pathway.
Wei-Chao DING ; Juan CHEN ; Quan LI ; Yi REN ; Meng-Meng WANG ; Wei ZHANG ; Xiao-Hang JI ; Xin-Yao WU ; Shi-Nan NIE ; Chang-Bao HUANG ; Zhao-Rui SUN
Chinese journal of integrative medicine 2025;31(11):1011-1020
OBJECTIVE:
To identify the underlying mechanism by which quercetin (Que) alleviates sepsis-related acute respiratory distress syndrome (ARDS).
METHODS:
In vivo, C57BL/6 mice were assigned to sham, cecal ligation and puncture (CLP), and CLP+Que (50 mg/kg) groups (n=15 per group) by using a random number table. The sepsisrelated ARDS mouse model was established using the CLP method. In vitro, the murine alveolar macrophages (MH-S) cells were classified into control, lipopolysaccharide (LPS), LPS+Que (10 μmol/L), and LPS+Que+acetylcysteine (NAC, 5 mmol/L) groups. The effect of Que on oxidative stress, inflammation, and apoptosis in mice lungs and MH-S cells was determined, and the mechanism with reactive oxygen species (ROS)/p38 mitogen-activated protein kinase (MAPK) pathway was also explored both in vivo and in vitro.
RESULTS:
Que alleviated lung injury in mice, as reflected by a reversal of pulmonary histopathologic changes as well as a reduction in lung wet/dry weight ratio and neutrophil infiltration (P<0.05 or P<0.01). Additionally, Que improved the survival rate and relieved gas exchange impairment in mice (P<0.01). Que treatment also remarkedly reduced malondialdehyde formation, superoxide dismutase and catalase depletion, and cell apoptosis both in vivo and in vitro (P<0.05 or P<0.01). Moreover, Que treatment diminished the release of inflammatory factors interleukin (IL)-1β, tumor necrosis factor-α, and IL-6 both in vivo and in vitro (P<0.05 or P<0.01). Mechanistic investigation clarifified that Que administration led to a decline in the phosphorylation of p38 MAPK in addition to the suppression of ROS expression (P<0.01). Furthermore, in LPS-induced MH-S cells, ROS inhibitor NAC further inhibited ROS/p38 MAPK pathway, as well as oxidative stress, inflammation, and cell apoptosis on the basis of Que treatment (P<0.05 or P<0.01).
CONCLUSION
Que was found to exert anti-oxidative, anti-inflammatory, and anti-apoptotic effects by suppressing the ROS/p38 MAPK pathway, thereby conferring protection for mice against sepsis-related ARDS.
Animals
;
Sepsis/drug therapy*
;
Quercetin/therapeutic use*
;
Respiratory Distress Syndrome/enzymology*
;
p38 Mitogen-Activated Protein Kinases/metabolism*
;
Mice, Inbred C57BL
;
Reactive Oxygen Species/metabolism*
;
Apoptosis/drug effects*
;
Male
;
Oxidative Stress/drug effects*
;
MAP Kinase Signaling System/drug effects*
;
Lung/drug effects*
;
Mice
;
Lipopolysaccharides
;
Macrophages, Alveolar/pathology*
;
Inflammation/pathology*
;
Protective Agents/therapeutic use*
10.Exploring the Efficacy of BMSC Transplantation via Various Pathways for Treating Cholestatic Liver Fibrosis in Mice.
Jun Jie REN ; Zi Xu LI ; Xin Rui SHI ; Ting Ting LYU ; Xiao Nan LI ; Min GE ; Qi Zhi SHUAI ; Ting Juan HUANG
Biomedical and Environmental Sciences 2025;38(4):447-458
OBJECTIVE:
To compare the therapeutic efficacy of portal and tail vein transplantation of bone marrow-derived mesenchymal stem cells (BMSCs) against cholestatic liver fibrosis in mice.
METHODS:
BMSCs were isolated and co-cultured with starvation-activated hepatic stellate cells (HSCs). HSC activation markers were identified using immunofluorescence and qRT-PCR. BMSCs were injected into the liver tissues of bile duct ligation (BDL) mice via the tail and portal veins. Histomorphology, liver function, inflammatory cytokines, and the expression of key proteins were all determined in the liver tissues.
RESULTS:
BMSCs inhibited HSC activation by reducing α-SMA and collagen I expression. Compared to tail vein injection, DIL-labeled BMSCs injected through the portal vein maintained a high homing rate in the liver. Moreover, BMSCs transplanted through the portal vein resulted in greater improvement in liver color, hardness, and gallbladder size than did those transplanted through the tail vein. Furthermore, BMSCs injected by portal vein, but not tail vein, markedly ameliorated liver function, reduced the secretion of inflammatory cytokines, including TNF-α, IL-6, and IL-1β, and decreased α-SMA + hepatic stellate cell (HSC) activation and collagen fiber formation.
CONCLUSION
The therapeutic effect of BMSCs on cholestatic liver fibrosis in mice via portal vein transplantation was superior to that of tail vein transplantation. This comparative study provides reference information for further BMSC studies focused on clinical cholestatic liver diseases.
Animals
;
Mice
;
Mesenchymal Stem Cell Transplantation
;
Liver Cirrhosis/etiology*
;
Male
;
Cholestasis/therapy*
;
Mice, Inbred C57BL
;
Hepatic Stellate Cells
;
Mesenchymal Stem Cells

Result Analysis
Print
Save
E-mail