1.Association between core symptoms and biological markers in children with autism spectrum disorders
FEI Xianyan, WANG Rui, CHAI Yangyang, HE Xianming, ZHENG Shizhu
Chinese Journal of School Health 2026;47(1):125-128
Objective:
To explore the relationship between serum homocysteine (Hcy), interleukin-5 (IL-5), folate and core symptoms in children with autism spectrum disorders, so as to provide potential biomarkers for early diagnosis and intervention of diseases.
Methods:
A total of 106 children with autism spectrum disorders and 106 healthy children with matched sex and age in Lu an People s Hospital were enrolled as autism group and healthy group between May 2020 to December 2023. On the day of admission, levels of serum Hcy, IL-5 and folate were detected. The core symptoms in autism group were evaluated by Autism Behavior Checklist (ABC), Wechsler Preschool and Primary Scale of Intelligence-fourth edition(WPPSI-IV), Childhood Autism Rating Scale (CARS) and Social Responsiveness Scale (SRS). The levels of serum Hcy, IL-5 and folate in the two groups were compared by t- test. The relationship between serum Hcy, IL-5, folate and core symptoms in children with autism spectrum disorders was determined by Pearson correlation analysis.
Results:
The levels of serum Hcy and IL-5 in autism group were (7.48±0.32) μmol/L and (345.77±32.51) pg/mL, higher than those in healthy group [(6.11±0.54) μmol/L, (274.04±25.17) pg/mL], while folate level was lower than that in healthy group [(15.24±3.47) ng/mL, (22.51±4.69) ng/mL], the differences were statistically significant ( t =22.47, 17.96, 12.83, all P < 0.05 ). In autism group, levels of serum Hcy and IL-5 were positively correlated with scores of ABC, CARS and SRS ( r =0.29, 0.53 , 0.54; 0.45, 0.41, 0.50), while negatively correlated with WPPSI-IV score ( r =-0.28, -0.26)(all P <0.05). The folate level was negatively correlated with scores of ABC, CARS and SRS ( r =-0.55, -0.40, -0.25), while positively correlated with WPPSI-IV score ( r =0.41) (all P <0.05).
Conclusion
Children with ASD show elevated serum Hcy and IL-5 alongside decreased folate,and three markers correlate with core symptoms and intellectual level.
2.Antibody levels of diphtheria and tetanus in healthy population in Pudong New Area, Shanghai, 2018-2024
Yu BAI ; Dandan YANG ; Wanran CHENG ; Rui ZHANG ; Pengfei DENG ; Caoyi XUE ; Laibao YANG ; Yi FEI
Journal of Public Health and Preventive Medicine 2026;37(3):52-55
Objective To understand the antibody levels of diphtheria and tetanus among healthy population in Shanghai Pudong New Area, and to provide a scientific basis for improving the vaccine immunization strategy. Methods Random sampling was used to select healthy people of all ages in 16 communities in Shanghai Pudong New Area from 2018 to 2024, and serum samples were collected and tested for serum anti-diphtheria and tetanus toxin IgG antibodies by enzyme-linked immunosorbent assay (ELISA) method to analyze the antibody positivity rate (≥0.1 IU/ml) and the geometric mean concentration (GMC) of antibodies. Results A total of 3 312 serum samples were included, with a male-to-female ratio of 0.76:1, and 53.77% were local residents. The seropositivity rates and geometric mean concentrations (GMC) of both diphtheria and tetanus antibodies generally declined with increasing age, but exhibited a transient rebound in the 7y-. A total of 1 175 individuals (35.48%) were seropositive for diphtheria, with a GMC of 0.054 IU/mL. For tetanus, 988 individuals (29.83%) were seropositive, with a GMC of 0.033 IU/mL. Significant differences in seropositivity rates (χ2diphtheria=950.005,χ2tetanus=1 324.393) and GMC (Hdiphtheria=1027.160,Htetanus=1 142.007) were observed among different age groups (P<0.001). Significant differences in seropositivity rates (χ2diphtheria=950.005,χ2tetanus=1324.393) and GMC (Hdiphtheria=1027.160,Htetanus=1142.007) were also found across different years (P<0.001). Conclusion The prevalence of diphtheria and tetanus antibodies in the healthy population of Pudong New Area is relatively low, particularly among adults over 20 years of age with inadequate immunization. This underscores the need to reinforce the National Immunization Program (NIP) vaccine specifications for children under 6 years of age and implement an immunization strategy for adolescents or adults against diphtheria and tetanus.
3.Application effect of a non-contact sleep monitoring mattress based on body movement characteristics during sleep
Yanchun ZHANG ; Yan LIU ; Rui WANG ; Feilong WANG ; Yue ZHAO ; Fei LI ; Tunan CHEN ; Jishu XIAN
Journal of Army Medical University 2025;47(4):326-334
Objective To verify the accuracy of a Non-Contact Sleep Monitoring Mattress(NCSMM)based on body movement during sleep in assessing sleep quality of patients before neurosurgery in order to provide a more portable and efficient assessment tool for clinical staff.Methods A single-arm trial was conducted on 114 inpatients admitted in our department selected with convenience sampling.Sleep quality data of 1 night were collected through 5 sleep quality assessment tools,including NCSMM,polysomnography(PSG),Patient-Reported Outcome Measurement Information System(PROMIS)Sleep Disturbance scale,Richards-Campbell Sleep Scale(RCSQ),and a wearable device(smart watch for body movements and sleep quality monitoring).The sleep efficiency(≤85%)obtained by PSG was used as the diagnostic standard for sleep disorders.The area under the receiver operating characteristic curve(AUC),sensitivity,specificity,positive predictive value,negative predictive value,and Youden index were calculated for the other 4 tools to evaluate and compare their diagnostic effectiveness.Results The AUC value for NCSMM,PROMIS,RCSQ and smart watch was 0.788(95%CI:0.687~0.888,P<0.001),0.664(95%CI:0.543~0.784,P=0.02),0.723(95%CI:0.600~0.846,P=0.001)and 0.750(95%CI:0.654~0.846,P<0.001),respectively.The diagnostic accuracy rate was 0.774,0.559,0.742 and 0.602,with corresponding Youden index value of 0.488,0.321,0.456,and 0.459.NCSMM demonstrated the best AUC value,sensitivity and Youden index when compared with the other 3 tools.Conclusion NCSMM shows high accuracy in assessing sleep quality in pre-neurosurgery inpatients,and it is a viable portable and efficient assessment tool in clinical practice.
4.Synthesis and Identification of Saturated Arsenic-containing Hydrocarbons
Jia-Jia CHEN ; Ying-Xiong ZHONG ; Xin-Huang KANG ; Chun-Mei DENG ; Bing-Bing SONG ; Xiao-Fei LIU ; Zhuo WANG ; Rui LI ; Jian-Ping CHEN ; Xue-Jing JIA ; Sai-Yi ZHONG
Chinese Journal of Analytical Chemistry 2025;53(3):472-480
Arsenic is a semi-metal,and lipid-soluble arsenic compounds are one of the widespread forms in the environment and food chain,but there is a lack of standards for lipid-soluble arsenic compounds,which is one of the bottlenecks in the current analytical detection and toxicological studies of organic arsenic.In this study,four saturated arsenic-containing hydrocarbons,AsHC 318,AsHC 332,AsHC 346,and AsHC 374(The number is relative molecular mass),were successfully synthesized in three steps by using dimethylarsinic acid,potassium iodide,sodium hydroxide,and four brominated alkanes(1-Bromotetradecane,1-bromopentadecane,1-bromohexadecane,and 1-bromooctadecane)as raw materials.The structures of these four saturated arsenic-containing hydrocarbons were characterized by proton nuclear magnetic resonance(1H NMR)spectroscopy,13C nuclear magnetic resonance(13C NMR)spectroscopy,and high-resolution mass spectrometry(HR-MS).The yields of the method were 8%-10%,and the synthesized compounds could be used in subsequent toxicity evaluation experiments to assess the toxic effects and mechanisms of action of arsenic-containing hydrocarbons.This study provided an effective method for synthesis of arsenic-containing hydrocarbons,enriching the synthesis methods of arsenic-containing hydrocarbons,and provided raw materials for the subsequent toxicological studies of arsenic-containing hydrocarbons.
5.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
6.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
7.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
8.Protective effect of total glucosides of paeony on glucocorticoid-induced liver inj ury and preliminary mechanisms
Qinxiang Deng ; Fei Ma ; Rui Shi ; Chun Wang ; Bingfa Xu
Acta Universitatis Medicinalis Anhui 2025;60(8):1463-1469,1477
Objective :
To investigate the protective effect of total glucosides of paeony ( TGP) on dexamethasone(DEX) ⁃induced liver injury in rats.
Methods:
Thirty SD rats were randomly divided into normal ( N) , DEX ,DEX + TGP (50 mg/kg) , DEX + TGP ( 100 mg/kg) , and DEX + TGP (200 mg/kg) groups , with 6 rats in each group. A rat model of liver injury was established by intraperitoneal injection of DEX ( 17. 5 mg/kg) . Serum levels of alanine aminotransferase ( ALT) , aspartate aminotransferase ( AST) , and alkaline phosphatase ( ALP) were measured , and the liver⁃to⁃body weight ratio was calculated. HE staining was performed to observe histopathological changes in the liver. The contents of malondialdehyde ( MDA) , superoxide dismutase ( SOD) , and glutathione (GSH) in liver tissues were determined. Western blot analysis was conducted to detect the expression levels of NADPH oxidase 4 ( NOX4 ) and endoplasmic reticulum stress⁃related proteins : glucose regulatory protein 94 homologous protein (CHOP) expression level in liver tissues.
Results:
Compared with the normal group , the DEX group exhibited significantly elevated serum levels of ALT , AST , ALP and liver⁃to⁃body weight ratio ( t = 14. 96 ,ing, degeneration , and necrosis ( t = 15. 49 , P < 0. 01) . Compared with the DEX group , there was no significant change in liver function biochemical indexes and liver histopathology in the TGP (50 mg/kg) treatment group. TGP treatment at 100 mg/kg and 200 mg/kg significantly attenuated these effects : both doses reduced ALT , AST , ALP and liver⁃to⁃body weight ratio( t = 3. 30 , 4. 13 , 7. 45 , 2. 97 , P < 0. 05 ; t = 8. 92 , 6. 45 , 8. 65 , 7. 47 , P < 0. 01) ,vealed that DEX administration significantly increased hepatic MDA levels ( t = 7. 06 , P < 0. 01) and NOX4 ex⁃pression ( t = 4. 23 , P < 0. 01) , whereas SOD activity ( t = 7. 78 , P < 0. 01) and GSH content ( t = 7. 92 , P <0. 01) were markedly suppressed. There was no significant change in the TGP (50 mg/kg) treatment group , TGP intervention at 100 mg/kg and 200 mg/kg effectively reversed these changes , lowering MDA and NOX4 levels( t = 3. 35 , 4. 30 , P < 0. 05 ; t = 5. 44 , 7. 44 , P < 0. 01) , while restoring SOD ( t200 mg/kg = 4. 04 , P < 0. 05) and GSH ( t = 4. 70 , P < 0. 05 ; t = 5. 50 , P < 0. 01) . Endoplasmic reticulum stress markers , including GRP94、GRP78、p- elF2α、CHOP ( t = 3. 31 , 6. 53 , 5. 18 , 3. 09 ; P < 0. 05 , 0. 01 , 0. 01 , 0. 05 ) , were significantly upregulated in the DEX group compared to the normal group. However, TGP treatment at 100 mg/kg and 200 mg/kg dose-dependent- ly suppressed the expression of GRP94、GRP78、p-elF2α、CHOP ( t = 3. 14 ,4. 95 , 3. 13 ,4. 25 , P < 0. 05 ; t = 4. 03 , 7. 48 ,4. 68 ,5. 10 ,P < 0. 01) expression levels were significantly reduced compared to the DEX group , and there was no significant change in the TGP (50 mg/kg) treatment group.
Conclusion
TGP exerts protective effects a- gainst DEX-induced liver injury , and its mechanism is likely mediated by suppressing hepatic oxidative stress and endoplasmic reticulum stress triggered by DEX in rats.
9.Treatment response to nucleos(t)ide analogs in chronic hepatitis B with mildly elevated alanine aminotransferase: Letter to the editor on “Antiviral therapy for chronic hepatitis B with mildly elevated aminotransferase: A rollover study from the TORCH-B trial”
Jian WANG ; Fei CAO ; Chuanwu ZHU ; Chao WU ; Rui HUANG
Clinical and Molecular Hepatology 2025;31(2):e140-e142
10.Comprehensive evaluation of powder-liquid double-chamber bag products: a systematic review
Fei SHU ; Rui SUN ; Kai SONG ; Yuanlin ZHANG ; Jiaming YAN ; Lixin SHU
Journal of Pharmaceutical Practice and Service 2025;43(2):92-96
Objective To evaluate the advantages of powder-liquid double-chamber bag products compared with traditional powder injection. Methods The systematic review method was used to collect the literature on powder-liquid double-chamber bag, extract common evaluation indicators, evaluate the use value of powder-liquid double-chamber bag products, and conduct a comprehensive comparison with traditional powder injection products. Results A total of 23 articles were included in the literature. The effectiveness indicators used for evaluation were the stability of the liquid medicine, the accuracy of the preparation concentration, and the residual amount of the liquid medicine; the safety indicators were the incidence of insoluble particles and the incidence of punctures and scratches. The economic indicators were preparation cost, occupied volume of preparation supplies, waste weight, hospitalization cost and incidence of blood infection. The applicability indicators were preparation time, average occupation of medical staff, packaging weight and storage and transportation volume, environmental adaptability, and ease of waste disposal. Accessibility indicators are the number of manufacturers, raw material supply capacity, and patient affordability. Through the evaluation of literature evidence, it was found that the stability and concentration accuracy of the powder-liquid double-chamber bag were higher than those of the traditional powder injection, and the domestic supply had been achieved. The double-chamber bag method can reduce the infusion reaction and shorten the preparation time of the liquid medicine. Conclusion Compared with traditional powder injectabler products, powder-liquid double-chamber bags have advantages in the dimensions of effectiveness, safety, economy, suitability and innovation, and the accessibility dimension meets the requirements.


Result Analysis
Print
Save
E-mail