1.The SMAD-Pathway Mediates HMGB1-Induced Proliferation and Metastatic Progression in Cutaneous Squamous Cell Carcinoma Cells
De-De LIAN ; Xue Mei LI ; Yu-Xi JIA ; Ming-Wei ZHOU ; Xiang-Ru CHEN ; Yang-Yang TIAN ; Min LI ; Ming-Hui SUN ; Ye ZHAO ; Hong-Jun LI ; Qing-Ling ZHANG
Annals of Dermatology 2026;38(1):51-58
Background:
High-mobility group box protein 1 (HMGB1) is a chromatin-binding protein involved in arthritis, ischemia, sepsis, atherosclerosis, neurodegenerative disorders, meningitis, and cancer. HMGB1 exhibits dual roles in cancer, acting as either a tumor suppressor or oncoprotein depending on context.
Objective:
This research aimed to elucidate HMGB1’s functional significance in cutaneous squamous cell carcinoma (cSCC).
Methods:
We overexpressed HMGB1 in cSCC cell lines using recombinant adenovirus and examined its effects on cell proliferation, colony formation, and cell migration.
Results:
Immunohistochemical analysis revealed elevated HMGB1 expression levels in cSCC tissue relative to normal epidermis. To assess the influence of HMGB1, we employed recombinant adenoviruses expressing HMGB1 to transduce SCC cell lines (SCC12 and SCC13). Enhanced HMGB1 expression significantly promoted cellular proliferation and colony formation capacity.Notably, HMGB1 overexpression elevated the levels of proliferation regulators, including P63, SOX2, CDK4 and CDK6. Furthermore, HMGB1 overexpression substantially enhanced tumor invasiveness, accompanied by upregulation of epithelial-mesenchymal transition (EMT) biomarkers. Mechanistically, overexpression of HMGB1 enhanced transforming growth factor-β signaling by increasing phosphorylation of SMAD2/3, the key mediators of EMT.
Conclusion
These data imply that HMGB1 acts as a tumor-promoting factor in cSCC.
2.Teaching practice of movable virtual reality equipment in human anatomy classroom teaching
Ping LIU ; Xuan FANG ; Hui-Ru DING ; Li-Ju LUAN ; Yan ZHANG ; Jun WANG ; Huai-Cun LIU ; Wei-Guang ZHANG
Acta Anatomica Sinica 2025;56(5):607-611
Objective To explore the integration value of mobile virtual reality devices in the classroom teaching of human anatomy,and to evaluate their potential impact on the in-depth construction of human anatomy knowledge,the cultivation of spatial cognitive ability,and the transformation of teaching paradigms from the perspectives of cognitive load theory and situated learning.Methods The undergraduate students majoring in clinical medicine in Peking University were selected as the research objects.Among them,students in grade 2019 were the control group,and students in grade 2022 were the experimental group,introducing movable virtual anatomy equipment and other teaching auxiliary method in theory and practice courses.The final exam scores of the two groups of students were compared,and a questionnaire survey was conducted for the experimental group after the course,and the survey result were statistically analyzed.Results The final examination result showed that the average score of the experimental group was 82.47±10.19,and the average score of the control group was 74.82±16.56,which was significantly higher in the experimental group than in the control group,with statistical significance(P<0.05).The questionnaire survey result showed that compared with traditional classroom teaching,94.62%of students preferred the new auxiliary teaching mode such as VR,96.77%of students believed that VR assisted teaching could achieve the traditional teaching effect or better,95.7%of them think that it improved students' interest in learning human anatomy,and 98.92%thought that it improved students' knowledge of anatomy.Conclusion The application of mobile virtual reality devices in anatomy classroom teaching provides immersive and interactive 3D visualization teaching scenarios,effectively reducing students' cognitive load on abstract and complex anatomical structures,promoting spatial understanding and knowledge internalization,significantly improving teaching effectiveness and self-learning ability,thus changing the traditional anatomy teaching mode and laying a solid foundation for the development of future medical education and the cultivation of medical talents.
3.Preparation and in vitro evaluation of an erythrocyte-based butyrylcholinesterase delivery system
Zhe WANG ; Changwen NING ; Huaying AN ; Xingwei JIANG ; Jun MA ; Fenghua GAO ; Pengyu LIU ; Yanan SUN ; Ru LI ; Jinlong LI ; Yuanyuan YUAN ; Qun YU
Military Medical Sciences 2025;49(6):458-464
Objective To develop an erythrocyte-based delivery system for butyrylcholinesterase(BChE)that is capable of prophylaxis against organophosphorus nerve agents.Methods Recombinant BChE was produced and analyzed for oligomerization via polyacrylamide gel electrophoresis(PAGE)and Western blotting.A modified hypotonic preswelling method was employed to prepare BChE-loaded erythrocytes.The drug loading capacity and encapsulation efficiency were quantified using enzyme-linked immunosorbent assay(ELISA).Catalytic activity was assessed in vitro with an activity detection kit.The system was characterized via scanning electron microscopy(SEM),flow cytometry and a hematology analyzer.Results Recombinant BChE predominantly existed as dimers(85%dimer,15%monomer).The optimized volume ratio of erythrocytes to hypotonic solution was determined as 1:7.Compared with native and empty erythrocytes,BChE-loaded erythrocytes exhibited significantly higher catalytic activity(P<0.001).The mean corpuscular volume of BChE-loaded erythrocytes increased(P<0.001),while the mean content of corpuscular hemoglobin and hemoglobin in erythrocytes per 100 mL decreased(P<0.001).SEM revealed no morphological differences(biconcave disc shape).Hypotonic preswelling moderately increased erythrocyte apoptosis(P<0.001),but no statistical difference was observed between BChE-loaded and hypotonic-treated erythrocytes(P>0.05).CD47 expression remained unchanged compared to native erythrocytes(P>0.05).Conclusion The modified hypotonic preswelling method can generate BChE-loaded erythrocytes that retain the characteristics of native erythrocytes while conferring catalytic activity,offering a novel strategy for clinical intervention against organophosphorus poisoning.
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
7.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
8.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
9.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
10.Analysis of risk factors for adjacent vertebral fractures after conservative treatment of osteoporotic vertebral compression fractures in elderly women.
Qing-Qing LI ; Jun ZHANG ; Jun-Gao ZHU ; Xuan-Liang RU
China Journal of Orthopaedics and Traumatology 2025;38(2):147-151
OBJECTIVE:
To study the relevant factors affecting the occurrence of adjacent vertebral fractures in women with osteoporotic vertebral compression fractures after conservative treatments.
METHODS:
A total of 98 elderly female patients diagnosed with osteoporotic vertebral compression fractures and treated from January 2020 to January 2022 were retrospectively analyzed. The average age was (73.05±7.38) years old. Based on the follow-up results after two years of injury, the patients were divided into the adjacent vertebral fracture group (24 cases) and the non-adjacent vertebral fracture group (74 cases). The following factors were recorded for each patient:age, initial bone density, follow-up bone density, bone density changes, initial VAS score, degree of fracture compression, presence of old fractures, use of zoledronic acid, use of parathyroid hormone analogs, occurrence of complications, and further compression of the affected vertebrae. Univariate and multivariate Logistic regression analyses were performed to analyze the associated risk factors.
RESULTS:
Univariate analysis revealed that in elderly women undergoing conservative treatment for osteoporotic vertebral compression fractures, the degree of fracture compression, follow-up bone density, changes in bone density, use of zoledronic acid, and use of parathyroid hormone analogs were statistically significant(P<0.05). Multivariate Logistic regression analysis demonstrated that the degree of fracture compression 95%CI(0.040, 0.571), P=0.005, OR=0.151, changes in bone density 95%CI(1.264, 1 360.732), P=0.036, OR=41.477, and use of parathyroid hormone analogs 95%CI(1.638, 31.625), P=0.009, OR=7.196 were risk factors affecting the occurrence of adjacent vertebral fractures following vertebral compression fractures in elderly women with osteoporosis.
CONCLUSION
The degree of fracture compression, changes in bone density, and the use of parathyroid hormone analogs are factors influencing the occurrence of adjacent vertebral fractures following vertebral compression fractures in elderly women with osteoporosis. For patients with mild compression fractures (gradeⅠ), conservative treatment can be achieved by intensifying anti-osteoporosis therapy and using parathyroid hormone analogs.
Humans
;
Female
;
Aged
;
Fractures, Compression/etiology*
;
Spinal Fractures/therapy*
;
Osteoporotic Fractures/therapy*
;
Retrospective Studies
;
Risk Factors
;
Conservative Treatment
;
Aged, 80 and over
;
Bone Density

Result Analysis
Print
Save
E-mail