1.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
2.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Comparative efficacy of different warming measures during the perioperative period of robotic-assisted total hip arthroplasty for femoral neck fracture in elderly patients
Ru GU ; Lei LEI ; Xu XU ; Wen WANG ; Geng ZHANG ; Tianle FAN ; Shuixia LI
Chinese Journal of Trauma 2025;41(9):852-857
Objective:To compare the efficacy of active warming versus conventional warming during the perioperative period of robotic-assisted total hip arthroplasty (THA) for femoral neck fracture in elderly patients.Methods:A retrospective cohort study was conducted to analyze the clinical data of 312 elderly patients with femoral neck fracture who underwent robot-assisted THA at Second Affiliated Hospital of Xi ′an Jiaotong University from January 2024 to January 2025, including 196 males and 116 females, aged 65-89 years [(77.0±7.3)years]. Among them, 156 patients received standardized thermal management (active warming group), involving the administration of pre-warmed intravenous fluids and use of an inflatable warming blanket preoperatively, combined application of a forced-air warming system and warmed fluids intraoperatively, and transfer to a temperature-controlled ward combined with a foot circulatory compression device postoperatively. The other 156 patients received conventional warming with cotton quilts (conventional warming group), involving no administration of pre-warmed intravenous fluids preoperatively, use of warmed fluids intraoperatively, and transfer to a standard ward without the use of a foot circulatory compression device postoperatively. Core body temperature was compared between the two groups at 30 minutes preoperatively, 30 minutes intraoperatively, immediately postoperatively, and at 1 hour, 1 day, 5 days, and 7 days postoperatively. Changes in the coagulation function, including prothrombin time (PT), thrombin time (TT), activated partial thromboplastin time (APTT), and the inflammatory marker C-reactive protein (CRP) were assessed at 1 day preoperatively and at 1, 5, and 7 days postoperatively. Length of hospital stay and incidence of postoperative complications (incision infection, deep vein thrombosis, cardiac complications, and unplanned reoperations) were also recorded. Results:The core body temperature at 30 minutes intraoperatively, immediately postoperatively and at 1 hour postoperatively was (36.77±0.17)℃, (36.29±0.14)℃, and (36.35±0.14)℃ in the active warming group, significantly higher than (36.12±0.27)℃, (35.49±0.25)℃, and (35.67±0.29)℃ in the conventional warming group ( P<0.01). No significant differences in body temperature were observed between the two groups at 30 minutes preoperatively, at 1, 5, or 7 days postoperatively ( P>0.05). At 1 day postoperatively, the PT, TT and APTT were (8.5±1.3)seconds, (10.0±0.9)seconds and (24.8±2.3)seconds, significantly lower than (9.7±1.3)seconds, (12.1±1.5)seconds and (29.2±2.7)seconds in the conventional warming group ( P<0.01). There were no significant differences in PT, TT, APTT or CRP levels between the two groups at 1 day preoperatively or at 5 and 7 days postoperatively ( P>0.05). The CRP level at 1 day postoperatively was (8.0±3.0)mg/L in the active warming group, significantly lower than (13.5±3.2)mg/L in the conventional warming group ( P<0.05). There were no significant differences in CRP between the two groups at 1 day preoperatively or at 5 and 7 days postoperatively ( P>0.05). The average length of hospital stay was (12.2±1.4)days in the active warming group, significantly shorter than (14.9±1.4)days in the conventional warming group ( P<0.01). The perioperative complication rate was 6.4% (10/156) in the active warming group, significantly lower than 17.9% (28/156) in the conventional warming group ( P<0.01). Conclusion:For elderly patients with femoral neck fracture operated via robot-assisted THA, active warming during the perioperative period can more effectively maintain intraoperative normothermia, improve early postoperative coagulation function, reduce inflammatory response, shorten the length of hospital stay, and decrease complication rate when compared with conventional warming.
6.Establishment of a rapid fluorescence immunochromatographic assay for avian influenza virus subtype H5N6
Hui LI ; Li LIU ; Yi-sheng ZHOU ; Zhi-hong ZHANG ; Qian-qian SI ; Ru-xia WANG ; Zhi-qiang DENG ; Yi-bing FAN ; Liang JIN ; Jie SUN ; Chun-hua YANG
Chinese Journal of Zoonoses 2025;41(3):243-248,283
In view of the characteristics of H5N6 subtype avian influenza virus(AIV)that it has both high pathogenicity and the risk of cross-species transmission,posing a serious threat to the poultry farming industry and public health security,in order to effectively prevent and control the spread of H5N6 avian influenza,a rapid,sensitive and specific detection technolo-gy was established in this study.The specific monoclonal antibodies against the neuraminidase N6 protein of avian influenza A virus subtype H5N6 were obtained through hybridoma and monoclonal antibody technology.These antibodies were coupled and labeled with carboxyl-functionalized fluorescent quantum dots,along with previously prepared specific antibodies against the hemagglutinin H5 protein.A rapid fluorescence immunochromatographic detection method for the H5N6 subtype of avian influ-enza virus was established according to the principle of double-antibody sandwich immunochromatography.This method a-chieved a detection sensitivity of 1 ng/mL for recombinant hemagglutinin H5 subtype protein and 0.1 ng/mL for recombinant neuraminidase N6 subtype protein.Moreover,the method exhibited no cross-reactivity with other influenza subtypes or patho-gens,such as Newcastle disease(ND),infectious bronchitis(IB),and infectious laryngotracheitis(ILT),thus demonstrating good specificity.The method effectively identified the highly pathogenic avian influenza virus H5 subtype and directly distin-guished the H5N6 subtype with good accuracy.The fluorescent quantum dot immunochromatographic typing detection method established herein met the sensitivity,specificity,and accuracy requirements for H5N6 subtype detection,and can be further used for rapid detection of the H5 and H5N6 subtypes of avian influenza virus.
7.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
8.Feasibility study of using clinical trial individual-level data sample bank as external control to support drug and device development:taking transcatheter aortic valve replacement device as an example
Xiao-ying LIN ; Chi-lie DANZENG ; Duo-er WANG ; Ying-xuan ZHU ; Ye LU ; Fan GAO ; Yuan-xin LI ; Meng-zhu SU ; Zi-long ZHANG ; Min CHEN ; Qi-ze LI ; Ru JIANG ; Yan-yan ZHAO ; Yang WANG
Chinese Journal of Interventional Cardiology 2025;33(8):459-466
Objective To explore the feasibility and corresponding implementation methods of constructing a sample resource bank based on individual-level data of completed clinical trials and using it to construct external controls for drug/device clinical trials.Methods Taking the pre-marketing clinical trial of transcatheter active valve replacement(TAVR)for the treatment of aortic valve stenosis as an example,the individual-level databases of multiple trials were standardized to form a sample bank.The original data of any trial in the sample bank were selected as the experimental group,and the remaining samples were selected as the control group.The potential confounding was handled by using the propensity score matching and stratification methods to clarify the process of constructing external controls based on the sample bank of individual-level data of clinical trials.Results This study included individual-level data of single-group trials of 4 TAVR devices,with a total of 569 subjects(59.2%male).The number of subjects in Trials 1 to 4 was 120,120,163,and 166,respectively.Propensity score matching enabled the matching of 113,117,125,and 147 subjects with comparable or similar characteristics from individual-level data from other trials,respectively,demonstrating a high matching success rate.The PS score distribution plot after stratification showed that the proportions of subjects in the experimental and control groups in strata 1 to 5 in scheme 1 were 4/103,11/103,22/92,32/87,and 51/64,respectively.For all constructed external controlled trials,a certain number of control samples with similar baseline characteristics to the experimental groups were distributed within each propensity score stratum.The results of the simulation test also reflected the potential differences between different devices in the 12-month all-cause mortality rate.Conclusions The sample bank constructed with individual-level data from clinical trials,as a high-quality data source,can serve as a source of external control for single-arm trials in the same field,and as a useful supplement to the external control scenario of real-world evidence to support drug and device development.At the same time,targeted research on research methods and bias control measures in related fields is also needed.
9.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
10.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]

Result Analysis
Print
Save
E-mail