1.Wenyang Lishui Formula Ameliorates Symptoms of Ovarian Hyperstimulation Syndrome: A Prospective Cohort Study.
Xi-Yan XIN ; Yang WANG ; Hua ZHANG ; Jia-Cheng ZHANG ; Meng-Jie FAN ; Xi ZHANG ; Jing XU ; Yang YE ; Xin-Yu HAO ; Dong LI ; Rong LI
Chinese journal of integrative medicine 2025;31(12):1059-1068
OBJECTIVE:
To study the clinical efficacy of Wenyang Lishui Formula (WYLSF) in preventing ovarian hyperstimulation syndrome (OHSS) and explore the suitable range of estradiol (E2) on the human chorionic gonadotropin (HCG) day in patients with OHSS using WYLSF.
METHODS:
Part I: eligible patients at high risk for OHSS undergoing ovulation induction between January and December, 2023 were randomized into 2 groups based on the actual treatment. The treatment group received 200 mL WYLSF formula twice daily for 5 days after oocyte retrieval in a combination of lifestyle coaching (LC) intervention including regular diet and exercise, whereas the LC group received LC intervention alone. The incidence of OHSS, OHSS self-assessment scales, changes in E2 levels on HCG day and 5 days after oocyte retrieval, ovarian morphology changes, and menstrual recovery were compared between the two groups. Part II: patients at high risk for OHSS treated with WYLSF were studied. The optimal E2 threshold on the HCG day was determined using the maximum selection test, and a multivariate analysis was adopted to compare the relationship between different E2 levels on HCG day and hospitalization rate, incidence of moderate to severe OHSS, and self-assessment scales, to explore the preventive effect of WYLSF on OHSS in patients with varying E2 levels.
RESULTS:
A total of 120 patients were included in the Part I analysis. The treatment group (60 cases) showed a significant reduction in the incidence, duration, and severity of abdominal distension, as well as the incidence of vomiting compared with the LC group (P<0.05). The post-retrieval E2 levels in the treatment group decreased significantly more (P=0.032). Among 1,652 patients treated with WYLSF in the Part II, 90 patients with ⩽ 10092 pmol/L, 159 with >31074 pmol/L, and 1,403 in the middle range group were formed based on E2 levels on HCG day in Part two analysis. Univariate and regression analyses showed that patients with E2 levels >31073 pmol/L had a significantly higher incidence of moderate to severe OHSS compared to those with E2 levels ⩽ 10092 pmol/L (P<0.05).
CONCLUSIONS
WYLSF can effectively reduce specific symptoms in high-risk OHSS patients after ovulation induction and significantly lower E2 levels. It may be more suitable for high-risk OHSS patients with E2 levels <31073 pmol/L on HCG day. (Registration No. MR-11-23-032493, https://www.medicalresearch.org.cn/login ).
Humans
;
Ovarian Hyperstimulation Syndrome/blood*
;
Female
;
Adult
;
Prospective Studies
;
Drugs, Chinese Herbal/pharmacology*
;
Estradiol/blood*
;
Ovulation Induction
;
Chorionic Gonadotropin
2.Construction of a Prognostic Model for Lysosome-dependent Cell Death in Gastric Cancer Based on Single-cell RNA-seq and Bulk RNA-seq Data.
Peng NI ; Kai Xin GUO ; Tian Yi LIANG ; Xin Shuang FAN ; Yan Qiao HUA ; Yang Ye GAO ; Shuai Yin CHEN ; Guang Cai DUAN ; Rong Guang ZHANG
Biomedical and Environmental Sciences 2025;38(4):416-432
OBJECTIVE:
To identify prognostic genes associated with lysosome-dependent cell death (LDCD) in patients with gastric cancer (GC).
METHODS:
Differentially expressed genes (DEGs) were identified using The Cancer Genome Atlas - Stomach Adenocarcinoma. Weighted gene co-expression network analysis was performed to identify the key module genes associated with LDCD score. Candidate genes were identified by DEGs and key module genes. Univariate Cox regression analysis, and least absolute shrinkage and selection operator regression and multivariate Cox regression analyses were performed for the selection of prognostic genes, and risk module was established. Subsequently, key cells were identified in the single-cell dataset (GSE183904), and prognostic gene expression was analyzed. Cell proliferation and migration were assessed using the Cell Counting Kit-8 assay and the wound healing assay.
RESULTS:
A total of 4,465 DEGs, 95 candidate genes, and 4 prognostic genes, including C19orf59, BATF2, TNFAIP2, and TNFSF18, were identified in the analysis. Receiver operating characteristic curves indicated the excellent predictive power of the risk model. Three key cell types (B cells, chief cells, and endothelial/pericyte cells) were identified in the GSE183904 dataset. C19orf59 and TNFAIP2 exhibited predominant expression in macrophage species, whereas TNFAIP2 evolved over time in endothelial/pericyte cells and chief cells. Functional experiments confirmed that interfering with C19orf59 inhibited proliferation and migration in GC cells.
CONCLUSION
C19orf59, BATF2, TNFAIP2, and TNFSF18 are prognostic genes associated with LDCD in GC. Furthermore, the risk model established in this study showed robust predictive power.
Stomach Neoplasms/pathology*
;
Humans
;
Prognosis
;
Lysosomes/physiology*
;
RNA-Seq
;
Cell Death
;
Single-Cell Analysis
;
Gene Expression Regulation, Neoplastic
;
Cell Proliferation
;
Single-Cell Gene Expression Analysis
3.Mechanism of Morinda officinalis iridoid glycosides alleviates bone deterioration in type II collagen-induced arthritic rats through down-regulating GSK-3β to inhibit JAK2/STAT3 and NF-κ B signaling pathway
Yi SHEN ; Yi-qi SUN ; He-ming LI ; Xin-yuan YE ; Jin-man DU ; Rong-hua BAO ; Quan-long ZHANG ; Lu-ping QIN ; Qiao-yan ZHANG
Acta Pharmaceutica Sinica 2024;59(10):2763-2772
This study aimed to investigate the therapeutic effects of
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
9.Influence of early blood glucose fluctuations after acute multiple injuries on post-traumatic stress disorder
Jingjing WANG ; Wenjia JIANG ; Yanze LI ; Ting XUE ; Ying YE ; Xianliang YAN ; Tie XU ; Rong HUA
Chinese Journal of Emergency Medicine 2024;33(5):623-629
Objective:To investigate the impact of early blood glucose fluctuations after acute multiple injuries on post-traumatic stress disorder (PTSD).Methods:This study was a case-control study. From March 2022 to March 2023, patients with acute multiple injuries who were admitted to the ICU of the Affiliated Hospital of Xuzhou Medical University were selected. According to whether complicated with traumatic brain injury (TBI), the patients were divided into TBI group and non-TBI group. Early post-traumatic blood glucose fluctuations were observed, including stress-induced hyperglycemia (SIH), initial blood glucose value on admission, blood glucose extreme, short-term glycemic variability (GV) and other related indicators. The 72-hour glucose coefficient of variation (Glu-CV) was used to reflect short-term GV. After 1 month, the PTSD checklist for DSM-5 (PCL-5) was used to assess the patient's symptoms of PTSD. The patients were divided into PTSD group and non-PTSD group according to PCL-5 score ≥38. The differences in short-term glucose fluctuations in each groups were compared; the risk factors of PTSD were analyzed by logistic regression; the receiver operating characteristic (ROC) curve was plotted to evaluate the predictive value of related indicators on the incidence of PTSD.Results:159 patients with acute multiple injuries were selected and defined as the TBI group ( n=94) and non-TBI group ( n=65). The incidence of PTSD, PCL-5 scale scores, the incidence of SIH and 72 h Glu-CV in the TBI group were significantly higher than the non-TBI group (all P<0.05). The incidence of SIH and 72 h Glu-CV in the PTSD group were significantly higher than the non-PTSD group (both P<0.05). Multivariate logistic regression analysis showed that 72 h Glu-CV ( OR=1.333, 95% CI: 1.028-1.727, P=0.030) was the independent risk factor for PTSD after acute multiple injuries, and the area under the ROC curve was 0.861 (95% CI: 0.789-0.933, P<0.001), the sensitivity was 62.9% and the specificity was 93.5%. Conclusion:Patients with acute multiple injuries with TBI are more likely to have early glucose fluctuations and develop PTSD, and increased short-term glucose variability is the independent risk factor for PTSD after acute multiple injuries.
10.Development and Reliability and Validity Analysis of the Knowledge,Attitude,and Practice Evaluation Scale for Teachers'Early Childhood Sex Education
Run YAN ; Ying YU ; Rong ZHANG ; Hua XIA ; Yunli YE
Acta Academiae Medicinae Sinicae 2024;46(5):666-670
Objective To develop the knowledge,attitude,and practice evaluation scale for teach-ers'early childhood sex education and analyze the reliability and validity of the scale,providing evaluation tools for the research on teachers'early childhood sex education.Methods On the basis of relevant guidelines,pub-lications,and the theory of knowledge,attitude,and practice,a preliminary pool of items for the scale was formed by group discussions.The scale was drafted after two rounds of Delphi expert consultation.In May 2023,stratified cluster sampling was conducted,and 535 preschool teachers from Changshou District,Chongqing were selected for a survey.Cronbach's α coefficient,split-half reliability,exploratory factor analysis,and content validity were adopted to assess the reliability and validity of the scale.Results An evaluation scale for teachers'early childhood sex education was formulated,involving 27 items in 3 dimensions of knowledge,attitude,and practice.The total Cronbach's α coefficient of the scale was 0.875,and that of the knowledge,attitude,and practice dimensions were 0.902,0.743,and 0.879,respectively.The total split-half reliability of the scale was 0.937,and that of the knowledge,attitude,and practice dimensions were 0.934,0.821,and 0.912,re-spectively.The content validity of the scale was good,with a factor loading range of 0.500-0.836 and a cumu-lative variance contribution rate of 61.57.The average score of teachers'knowledge,attitude,and practice in sex education was 72.85±7.13,with a good rate of 70.84%.Conclusions The developed scale for evaluating teacher's early childhood sex education demonstrates good reliability and validity,and it can be used to evaluate the teachers'knowledge,attitude,and practice in early childhood sex education.The evaluation results indicate that teachers have low levels of knowledge,attitude,and practice in sex education,and relevant departments need to carry out training on the sex education for young children.

Result Analysis
Print
Save
E-mail