1.CT-guided fine-needle assisted localization for puncturing difficult lung or liver lesions
Jian ZHANG ; Zhongbao TAN ; Zhenhai DI ; Xuequn MAO ; Rong ZOU ; Qingqing WANG ; Zhuang HAN
Chinese Journal of Interventional Imaging and Therapy 2024;21(8):482-485
Objective To observe the feasibility and safety of CT-guided fine-needle assisted localization for puncturing difficult lung or liver lesions.Methods Data of 30 patients with single difficult lung or liver lesion,i.e.lesion located at difficult part for puncturing or deep lesion with diameter of 0.5-2.0 cm who underwent CT-guided 22G needle assisted localization before puncturing were retrospectively analyzed.The success rate of fine-needle assisted localization,the success rate of the first-time puncturing and the occurrence of complications were recorded.Results Among 30 difficult lesions,there were 27 lung lesions and 3 hepatic lesions,with a mean diameter of(1.0±0.4)cm.Assisted localization of difficult lesions were successfully performed with 22G needle under CT guidance at the edge of lesion,1 cm adjacent to lesion or at the puncture path,with success rate of fine-needle assisted localization of 100%,and no obvious complication happened.The followed operations included preoperative localization of 14 lung nodules,biopsy of 10 lung nodules and 3 liver nodules,as well as microwave ablation of 3 liver nodules,with the success rate of the first-time puncturing of 100%.Mild pneumothorax was observed in 3 cases(3/27,11.11%)of difficult lung lesions after biopy.No other obvious complication occurred.Conclusion CT-guided fine-needle assisted localization for percutaneous puncturing difficult lung or liver lesions was feasible and safe.
2.Association between variation of WFS1 gene and early-onset type 2 diabetes mellitus in Chinese population
Chanwei LIU ; Xiaoxu GE ; Ming LI ; Tiantian LI ; Langen ZHUANG ; Rong ZHANG ; Juan ZHANG ; Yating CHEN ; Fusong JIANG ; Limei LIU
Chinese Journal of Diabetes 2024;32(7):481-487
Objective To explore the association between R611H(G/A,rs734312)variation of WFS1 gene and early-onset type 2 diabetes mellitus(T2DM).Methods A total of 181 Chinese patients with early-onset T2DM(T2DM group)and 196 non-diabetic controls(NC group)were enrolled in this study.The rs734312 variation was detected by PCR-direct sequencing.Genotypic and allelic frequencies of rs734312 and clinical variables were compared and analyzed between the two groups.Results Compared with the NC group,the frequencies of AA genotype and A allele in R611H(G→A)variation were significantly elevated in the early-onset T2DM group,AA vs GA+GG(OR 1.720,95%CI 1.100~2.680,P<0.05).A vs G(OR 1.500,95%CI 1.020~2.220,P<0.05).The remarkable differences of frequencies of genotype and allele in rs734312(G/A)were observed between Asians(China,Japan and Korea)and Caucasians(Denmark,Britain,Spain,France and Russia,P<0.01 for each).Compared with AA genotype,fasting and 2 hours postprandial insulin(FIns and 2 hIns)as well as HOMA-β were significantly rise in GG+GA genotype carriers of early-onset T2DM group(P<0.05).Conclusions The a allele of rs734312 in WFS1 may be a risk factor for early-onset T2DM in Chinese population,and the variation might be a potential genetic marker for predicting the islet β-cell dysfunction in early-onset T2DM in Chinese population.
3.Value of cystic fluid carcinoembryonic antigen combined with glucose detection in the diagnosis of mucinous cystadenoma of pancreas
Ying ZHUANG ; Jiayun CHEN ; Yan QIU ; Rong ZUO ; Dandan WANG ; Shihua LIU
Modern Interventional Diagnosis and Treatment in Gastroenterology 2024;29(7):794-798
Background and Objective Accurate diagnosis of mucous cystic lesion(PCL)remains a clinical difficult.Both Carcinoembryonic antigen(CEA)and glucose(GLU)are reported to have ability to distinguish mucinous PCL from non-mucinous PCL,but the accuracy was limited.The objective of this study was to evaluate the value of cystic CEA combined with GLU in the diagnosis of mucinous PCL.Methods PCL patients who underwent pancreatic surgery and endoscopic ultrasonography guided fine-needle aspiration(EUS-FNA)were retrospectively collected from the First Affiliated Hospital of Naval Medical University.Clinical data and cystic fluid analysis of included PCLs patients were analyzed using receiver operator(ROC)curves.ROC analysis,sensitivity and specificity analyses were used to evaluate the value of CEA combined with GLU in the diagnosis of mucinous PCL.Results From January 2015 to December 2021,a total of 84 patients underwent cyst fluid CEA and GLU analysis,of whom 44(52.4%)had mucinous PCL and 40(47.6%)had non-mucinous PCL.The AUC for distinguishing mucinous from non-mucinous PCL by CEA was 0.82[(95%confidence interval(CI):0.72-0.92)].When 192 ng/mL was used as the cutoff level,the diagnostic sensitivity and specificity were 50%and 93%,respectively.Using 20 ng/mL as cutoff level,the diagnostic sensitivity increased to 80%and the specificity decreased to 68%.The AUC for the cystic GLU to distinguish mucinous from non-mucinous PCL was 0.73(95%CI:0.99-0.87),and the diagnostic sensitivity and specificity were 100%and 60%,respectively.When the cutoff level of CEA was 192 ng/mL,the AUC of CEA combined with GLU in the diagnosis of mucinous PCLs was 0.94(95%Cl:0.86-0.99),while when the cutoff level of CEA was 20 ng/mL,the AUC of CEA combined with Glu in the diagnosis of mucinous PCLs was 0.94(95%CI:0.85-0.99).The AUCs were significantly higher than the AUC with single diagnostic indicators.Conclusion When using the cutoff level of 192 ng/mL,cyst fluid CEA combined with GLU has high sensitivity and specificity in differentiating mucinous PCL from non-mucinous PCL,so it can be considered for clinical application.Lower CEA cutoff level(20 ng/mL)can improve the sensitivity of diagnosis.
4.Evaluation on the effect of applying comprehensive interventions on pro-moting pathogen detection before antimicrobial therapy in hospitalized pa-tients
ZHUYi ; Jian-Wen ZHUANG ; Ying-Ying PAN ; Li-Na ZOU ; Yu-Rong HUANG
Chinese Journal of Infection Control 2024;23(5):600-604
Objective To explore the effect of applying comprehensive interventions on promoting pathogen detec-tion before antimicrobial therapy in hospitalized patients.Methods Hospitalized patients who received therapeutic use of antimicrobial agents in a tertiary first-class hospital from January 2020 to December 2021 were selected as the research subjects.Comprehensive intervention measures were implemented from January 2021.The pathogen detec-tion rates,detection classification,and detection rates of key monitored departments before antimicrobial therapy were compared between the pre-intervention group(January-December 2020)and the post-intervention group(Janu-ary-December 2021).Results A total of 10 239 hospitalized patients who received therapeutic use of antimicrobial agents were included in analysis,4 526 cases were in the pre-intervention group and 5 713 cases in the post-interven-tion group.The pathogen detection rates before antimicrobial therapy,before restricted grade antimicrobial therapy,and before special grade antimicrobial therapy after intervention were 94.56%,94.72%,and 96.03%,respective-ly,which were higher than 83.74%,84.47%,and 84.95%before intervention,with statistical significance(all P<0.05).The detection rate of targeted pathogens after intervention was 64.87%,higher than that before interven-tion(28.04%),with statistically significant difference(P<0.05).The pathogen detection rates before therapeutic use of antimicrobial agents in departments of critical care medicine,pulmonary and critical care medicine,pediatrics,neurosurgery,and general surgery after intervention were 93.20%,91.17%,92.20%,94.12%,and 91.15%,re-spectively,higher than the rates before intervention,namely 85.00%,82.19%,83.20%,83.33%,and 83.03%,respectively,with statistical significance(all P<0.05).Conclusion The application of comprehensive intervention measures can improve the pathogen detection rate before antimicrobial therapy of hospitalized patients.Close atten-tion should be paid to the pathogen detection indicators related to healthcare-associated infection diagnosis and for the detection of sterile body fluid.
5.Short-term results of sleeve wrapping technique using remnant aortic wall in modified Bentall procedure
MENG Maolong ; Yao WANG ; Pingfan LU ; Huapeng LI ; Rong REN ; Wen ZHANG ; Fengjie CHEN ; Xianmian ZHUANG ; Xiang WANG ; Gang LI ; Hongwei GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):283-287
Objective To evaluate the short-term results of sleeve wrapping technique using remnant aortic wall in modified Bentall procedure. Methods The patients undergoing modified Bentall procedure with the remnant aortic wall as a sleeve to cover the sewing area of composite valved graft and the aortic annulus for proximal hemostasis between March 2021 and March 2022 in Shenzhen Fuwai Hospital were enrolled. Short-term results were assessed by cardiopulmonary bypass time, aortic clamping time, mechanical ventilation time, ICU stay, postoperative hospital stay, effusion drainage on the first postoperative day, left ventricular ejection fraction (LVEF), left ventricular end diastolic diameter (LVEDD), and follow-up results. Results A total of 14 patients were collected, including 12 males and 2 females, with a mean age of 55.33±10.57 years. There was no postoperative or follow-up death. Cardiopulmonary bypass time was 147.90±21.29 min, aortic clamping time was 115.70±15.23 min, mechanical ventilation time was 19.42±8.98 h, ICU stay was 99.08±49.42 h, and postoperative hospital stay was 16.33±2.74 d. Thoracic drainage volume was 333.33±91.98 mL on the first postoperative day. Only 2 patients required blood transfusion (4.5 U and 2 U, respectively). During the follow-up of 6.17±3.69 months, there was no death, no aortic or valve-related complications. There was statistical difference in the LVEDD between preoperation and before discharge after surgery (P<0.001), and between half a year after surgery and before discharge after surgery (P<0.001). There was a little decrease of LVEF before discharge after surgery compared with preoperative LVEF, but there was no statistical difference (P=0.219). There was no statistical difference in the LVEF half a year after operation compared with that before operation (P=1.000). Conclusion Sleeve wrapping technique using remnant aortic wall in modified Bentall procedure has good short-term results. This modification may be a simple, effective way in controlling proximal bleeding.
6.Drug metabolism and excretion of14Cbirociclib in Chinese male healthy subjects
Quan-Kun ZHUANG ; Hui-Rong FAN ; Shi-Qi DONG ; Bin-Ke FAN ; Ming-Ming LIU ; Ling-Mei XU ; Li WANG ; Xue-Mei LIU ; Fang HOU
The Chinese Journal of Clinical Pharmacology 2024;40(14):2118-2123
Objective To evaluate the characteristics of the mass balance and pharmacokinetics of[14 C]birociclib in Chinese male healthy volunteers after a single oral administration.Methods This study used a 14 C labeled method to investigate the mass balance and biological transformation of birociclib in human.Subjects were given a single oral dose of 360 mg/50 pCi of[14 C]birociclib suspension after meals.The blood,urine,and fecal samples were collected at specified time points/intervals after administration.The radiation levels of 14 C labeled birociclib-related compounds in the blood,plasma,urine,and feces were analyzed using liquid scintillation counting.In addition,a combination of high-performance liquid chromatography and on-line/off-line isotope detectors was used to obtain radioactive isotope metabolite spectra of plasma,urine,and fecal samples,and high-resolution mass spectrometry was used to identify the main metabolites.Results A total of 6 healthy male subjects were enrolled in this study.The median peak time of radioactive components in plasma was 5.00 h and the average terminal elimination half-life was 43.70 h after administration.The radioactive components were basically excreted and cleared from the body within 288.00 hours after administration,and average cumulative recovery rate of radioactive drugs was(94.10±8.19)%.The radioactive drugs were mainly excreted through feces,accounting for(84.60±7.10)%of the dose of radioactive drugs administered.Urine was the secondary excretory pathway,accounting for 9.41%of the dose of radioactive drugs administered.Metabolic analysis indicated that the prototype drug was the main radioactive components in plasma samples.The main metabolites in plasma were RM4(XZP-5286),RM6(XZP-3584),and RM7(XZP-5736).The drugs were mainly cleared from the body in the form of prototype drugs and metabolites.In addition to prototype drugs,a total of 9 metabolites were identified and analyzed in plasma,urine,and fecal samples,all of which were phase 1 metabolites.The main metabolic and clearance pathways of drugs in the body were deethylation,diisopropylat ion,oxidation,etc.Conclusion After a single oral administration of[14C]birociclib suspension to healthy subjects,it was mainly cleared from the body in the form of prototype drugs and metabolites,with feces as the main excretory pathway and urine as the secondary excretory pathway.Drugs mainly undergo metabolic reactions in the body,such as deethylation,diisopropylation,and oxidation.The subjects were well tolerance after administration.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail