1.Comparative study of orthopaedic robot-assisted minimally invasive surgery and open surgery for limb osteoid osteoma.
Junwei FENG ; Weimin LIANG ; Yue WANG ; Zhi TANG ; MuFuSha A ; Baoxiu XU ; Niezhenghao HE ; Peng HAO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):40-45
OBJECTIVE:
To compare the accuracy and effectiveness of orthopaedic robot-assisted minimally invasive surgery versus open surgery for limb osteoid osteoma.
METHODS:
A clinical data of 36 patients with limb osteoid osteomas admitted between June 2016 and June 2023 was retrospectively analyzed. Among them, 16 patients underwent orthopaedic robot-assisted minimally invasive surgery (robot-assisted surgery group), and 20 patients underwent tumor resection after lotcated by C-arm X-ray fluoroscopy (open surgery group). There was no significant difference between the two groups in the gender, age, lesion site, tumor nidus diameter, and preoperative pain visual analogue scale (VAS) scores ( P>0.05). The operation time, lesion resection time, intraoperative blood loss, intraoperative fluoroscopy frequency, lesion resection accuracy, and postoperative analgesic use frequency were recorded and compared between the two groups. The VAS scores for pain severity were compared preoperatively and at 3 days and 3 months postoperatively.
RESULTS:
Compared with the open surgery group, the robot-assisted surgery group had a longer operation time, less intraoperative blood loss, less fluoroscopy frequency, less postoperative analgesic use frequency, and higher lesion resection accuracy ( P<0.05). There was no significant difference in lesion resection time ( P>0.05). All patients were followed up after surgery, with a follow-up period of 3-24 months (median, 12 months) in the two groups. No postoperative complication such as wound infection or fracture occurred in either group during follow-up. No tumor recurrence was observed during follow-up. The VAS scores significantly improved in both groups at 3 days and 3 months after surgery when compared with preoperative value ( P<0.05). The VAS score at 3 days after surgery was significantly lower in robot-assisted surgery group than that in open surgery group ( P<0.05). However, there was no significant difference in VAS scores at 3 months between the two groups ( P>0.05).
CONCLUSION
Compared with open surgery, robot-assisted resection of limb osteoid osteomas has longer operation time, but the accuracy of lesion resection improve, intraoperative blood loss reduce, and early postoperative pain is lighter. It has the advantages of precision and minimally invasive surgery.
Humans
;
Robotics
;
Osteoma, Osteoid/surgery*
;
Orthopedics
;
Blood Loss, Surgical
;
Retrospective Studies
;
Neoplasm Recurrence, Local
;
Minimally Invasive Surgical Procedures
;
Bone Neoplasms/surgery*
;
Analgesics
;
Treatment Outcome
2.Feasibility analysis of puncture robot technology for the application of acupuncture robot.
Wen-Yin YANG ; Guo-Jie WANG ; Ming-Xia TANG ; Qi QIAN ; Xiao-Tong HE ; Tian-Cheng XU
Chinese Acupuncture & Moxibustion 2023;43(4):463-468
The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.
Animals
;
Humans
;
Robotics
;
Feasibility Studies
;
Acupuncture Therapy
;
Punctures
;
Acupuncture
;
Needles
3.Robotic solution for orthopedic surgery.
Mingxing FAN ; Qi ZHANG ; Yanming FANG ; Wei TIAN
Chinese Medical Journal 2023;136(12):1387-1389
4.Clinical effects of robot-assisted esophageal hiatal hernia repair and laparoscopic esophageal hiatal hernia repair: a retrospective comparative study.
Maimaitiaili MAIMAITIMING ; Duolikun YASHENG ; Yierxiatijiang AINIWAER ; Y L LI ; Aikebaier AILI ; J WANG ; Ke LIMU
Chinese Journal of Surgery 2023;61(6):498-502
Objective: To analyze the short-term clinical effects of robot-assisted and laparoscopic repair of the hiatal hernia. Methods: The clinical data of 56 patients underwent minimally invasive hiatal hernia repair from January 2021 to January 2022 in the Department of Minimally Invasive Surgery, Hernias and Abdominal Wall Surgery, People's Hospital of Xinjiang Uygur Autonomous Region were retrospectively analyzed. There were 32 males and 24 females, aging (59.7±10.7) years (range: 28 to 75 years). All patients were divided into laparoscopy group (n=27) and robot group (n=29) according to surgical procedures. Perioperative conditions, hospital stay, and improvement in symptoms before and after surgery were compared between the two groups by the t test, Wilcoxon rank-sum test and χ2 test. Results: All surgical procedures were successfully completed, without conversion to laparotomy or change in operation mode. There were no serious complications related to the operation. The intraoperative blood loss of the robot group was less than that of the laparoscopic group (M (IQR)): (20 (110) ml vs. 40 (80) ml, Z=-4.098, P<0.01). The operation time ((111.7±33.6) minutes vs. (120.4±35.0) minutes, t=-0.943, P=0.350) and hospitalization time ((3.9±1.4) days vs. (4.7±1.9) days, t=-1.980, P=0.053) of the robot group and the laparoscopic group were similar. Follow-up for 12 months after the operation showed no postoperative complications and recurrence. The score of the health-related quality of life questionnaire for gastroesophageal reflux disease in the robot group decreased from 10.8±2.8 before the operation to 6.5±0.6 after the operation, and that in the laparoscopic group decreased from 10.6±2.1 before the operation to 6.3±0.6 after the operation. There was no difference in the influence of different surgical methods on the change in score (t=0.030,P=0.976). Conclusion: Compared with laparoscopic repair of the hiatal hernia, robot-assisted hiatal hernia repair has the advantages of less bleeding, rapid postoperative recovery and good short-term effect.
Male
;
Female
;
Humans
;
Hernia, Hiatal/complications*
;
Retrospective Studies
;
Robotics
;
Herniorrhaphy/methods*
;
Quality of Life
;
Laparoscopy/methods*
;
Recurrence
;
Fundoplication/methods*
5.Development of a flexible embedded neurostimulator for animal robots.
Zhenling SU ; Dongyun WANG ; Xiaomin QI ; Chenguang YANG ; Yexin ZHANG ; Kaige LIU ; Yue QIN ; Xinyu LIU
Journal of Biomedical Engineering 2023;40(2):327-334
The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.
Animals
;
Robotics
6.A comparative study of short-term effectiveness of "SkyWalker" robot-assisted versus traditional total knee arthroplasty.
Haoming AN ; Hangyu PING ; Haifeng LI ; Wei CHAI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):404-409
OBJECTIVE:
To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.
METHODS:
A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.
RESULTS:
The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).
CONCLUSION
The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Treatment Outcome
7.Treatment of stage Ⅱ-Ⅲ Kümmell disease with robot-assisted bone cement-augmented pedicle screw fixation.
Jian-Qiao ZHANG ; Xiao ZHOU ; Hui-Gen LU ; Bao CHEN ; Ye-Feng YU ; Xu-Qi HU ; Min-Jie HU ; Xue-Kang PAN
China Journal of Orthopaedics and Traumatology 2023;36(5):465-472
OBJECTIVE:
To evaluate the early clinical efficacy of robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation in the treatment of stageⅡ-Ⅲ Kümmell disease.
METHODS:
The clinical data of 20 patients with stageⅡ-Ⅲ Kümmell's disease who underwent robot-assisted percutaneous bone cement-augmented pedicle screw fixation between June 2017 and January 2021 were retrospectively analyzed. There were 4 males and 16 females, aged from 60 to 81 years old with an average age of (69.1±8.3) years. There were 9 cases of stageⅡand 11 cases of stage Ⅲ, all of which were single vertebral lesions, including 3 cases of T11, 5 cases of T12, 8 cases of L1, 3 cases of L2, and 1 case of L3. These patients did not exhibit symptoms of spinal cord injury. The operation time, intraoperative blood loss, and complications were recorded. The position of pedicle screws and the filling and leakage of bone cement in gaps were observed using postoperative CT 2D reconstruction. The data of the visual analogue scale (VAS), Oswestry disability index (ODI), kyphosis Cobb angle, wedge angle of the diseased vertebra, and anterior and posterior vertebral height on lateral radiographs were statistically analyzed preoperatively, 1 week postoperatively, and at the final follow-up.
RESULTS:
Twenty patients were followed up for 10 to 26 months, with an average follow-up of (16.0±5.1) months. All operations were successfully completed. The surgical duration ranged from 98 to 160 minutes, with an average of (122±24) minutes. The intraoperative blood loss ranged from 25 to 95 ml, with an average of (45±20) ml. There were no intraoperative vascular nerve injuries. A total of 120 screws were inserted in this group, including 111 screws at grade A and 9 screws at grade B according to the Gertzbein and Robbins scales. Postoperative CT indicated that the bone cement was well-filled in the diseased vertebra, and cement leakage occurred in 4 cases. Preoperative VAS and ODI were (6.05±0.18) points and (71.10±5.37)%, respectively, (2.05±0.14) points and (18.57±2.77)% at 1 week after operation, and (1.35±0.11) points and (15.71±2.12) % at final follow-up. There were significant differences between postoperative 1 week and preoperative, and between final follow-up and postoperative 1 week(P<0.01). Anterior and posterior vertebral height, kyphosis Cobb angle, and wedge angle of the diseased vertebra were(45.07±1.06)%, (82.02±2.11)%, (19.49±0.77) °, and (17.56±0.94) ° preoperatively, respectively, (77.00±0.99)%, (83.04±2.02)%, (7.34±0.56) °, and (6.15±0.52) ° at 1 week postoperatively, and (75.13±0.86)%, (82.39±0.45)%, (8.38±0.63) °, and (7.09±0.59) ° at the final follow-up.
CONCLUSION
Robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation demonstrates satisfactory short-term efficacy in treating stageⅡ-Ⅲ Kümmell's disease as an effective minimally invasive alternative. However, longer operation times and strict patient selection criteria are necessary, and long-term follow-up is required to determine its lasting effectiveness.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Pedicle Screws
;
Bone Cements
;
Robotics
;
Blood Loss, Surgical
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Lumbar Vertebrae/injuries*
;
Treatment Outcome
;
Kyphosis
;
Thoracic Vertebrae/injuries*
;
Fracture Fixation, Internal
8.Comparison of the learning curve of robot -assisted and laparoscopic -assisted gastrectomy.
Jingmao XIE ; Yang LEI ; Hao ZHANG ; Yihui LIU ; Bo YI
Journal of Central South University(Medical Sciences) 2023;48(5):716-724
OBJECTIVES:
Da Vinci robot technology is widely used in clinic,with minimally invasive surgery development. This study aims to explore the possible influence of advanced surgical robotics on the surgery learning curve by comparing the initial clinical learning curves of 2 different surgical techniques: robotic-assisted gastrectomy (RAG) and laparoscopic-assisted gastrectomy (LAG).
METHODS:
From September 2017 to December 2020, a chief surgeon completed a total of 108 cases of radical gastric cancer from the initial stage, including 27 cases of RAG of the Da Vinci Si robotic system (RAG group) and 81 cases of LAG (LAG group). The lymph node of gastric cancer implemented by the Japanese treatment guidelines of gastric cancer. The surgical results, postoperative complications, oncology results and learning curve were analyzed.
RESULTS:
There was no significant difference in general data, tumor size, pathological grade and clinical stage between the 2 groups (P>0.05). The incidence of serious complications in the RAG group was lower than the LAG group (P=0.003). The intraoperative blood loss in the RAG group was lower than that in the LAG group (P=0.046). The number of lymph nodes cleaned in the RAG group was more (P=0.003), among which there was obvious advantage in lymph node cleaning in the No.9 group (P=0.038) and 11p group (P=0.015). The operation time of the RAG group was significantly longer than the LAG group (P=0.015). The analysis of learning curve found that the cumulative sum analysis (CUSUM) value of the RAG group decreased from the 10th case, while the CUSUM of the LAG group decreased from the 28th case. The learning curve of the RAG group had fewer closing cases than that of the LAG group. The unique design of the surgical robot might help to improve the surgical efficiency and shorten the surgical learning curve.
CONCLUSIONS
Advanced robotics helps experienced surgeons quickly learn to master RAG skills. With the help of robotics, RAG are superior to LAG in No.9 and 11p lymph node dissection and surgical trauma reduction. RAG can clear more lymph nodes than LAG, and has better perioperative effect.
Humans
;
Robotics
;
Robotic Surgical Procedures/methods*
;
Learning Curve
;
Stomach Neoplasms/pathology*
;
Retrospective Studies
;
Laparoscopy/methods*
;
Lymph Node Excision/methods*
;
Gastrectomy/methods*
;
Treatment Outcome
9.Robot-assisted laparoscopic enucleation in the treatment of leiomyosarcoma of urinary bladder: A case report.
Zhongyi ZENG ; Xiao WU ; Kai PENG ; Da REN ; Xuan ZHU ; Lei ZHANG
Journal of Central South University(Medical Sciences) 2023;48(5):782-788
Leiomyosarcoma of urinary bladder (LMS-UB) is a highly malignant mesenchymal tumor, accounting for less than 0.5% of all bladder malignancies, with a predominant clinical presentation of hematuria. Here we report a case of low-grade LMS-UB. A 44-year-old male patient was admitted to the hospital with urodynia for 2 weeks. The patient's pelvis CT showed a mass on the right part of the bladder. For this reason, he was initially diagnosed with bladder cancer. We performed a robot-assisted laparoscopic enucleation of the bladder tumor and low-grade LMS-UB was diagnosed with the histopathological examination. He underwent 5 cycles of adjuvant chemotherapy after surgery. At 19months postoperative follow-up, the patient had no symptoms, recurrence, or distant metastasis. There is no report on the treatment of LMS-UB with minimally invasive enucleation worldwide. This case provides a new comprehensive treatment method of enucleation combined with adjuvant chemotherapy for early low-grade LMS-UB to reduce complications and improve patients' quality of life after surgery.
Male
;
Humans
;
Adult
;
Urinary Bladder/surgery*
;
Leiomyosarcoma/secondary*
;
Robotics
;
Quality of Life
;
Pelvis/pathology*
;
Urinary Bladder Neoplasms/pathology*
;
Laparoscopy/methods*
10.Network meta-analysis comparing the clinical outcomes and safety of robotic, laparoscopic, and transanal total rectal mesenteric resection for rectal cancer.
Yuan LIU ; Wei SHEN ; Zhi Qiang TIAN ; Yin Chao ZHANG ; Guo Qing TAO ; Yan Fei ZHU ; Guo Dong SONG ; Jia Cheng CAO ; Yu Kang HUANG ; Chen SONG
Chinese Journal of Gastrointestinal Surgery 2023;26(5):475-484
Objective: To methodically assess the clinical effectiveness and safety of robot-assisted total rectal mesenteric resection (RTME), laparoscopic-assisted total rectal mesenteric resection (laTME), and transanal total rectal mesenteric resection (taTME). Methods: A computer search was conducted on PubMed, Embase, Cochrane Library, and Ovid databases to identify English-language reports published between January 2017 and January 2022 that compared the clinical efficacy of the three surgical procedures of RTME, laTME, and taTME. The quality of the studies was evaluated using the NOS and JADAD scales for retrospective cohort studies and randomized controlled trials, respectively. Direct meta-analysis and reticulated meta-analysis were performed using Review Manager software and R software, respectively. Results: Twenty-nine publications comprising 8,339 patients with rectal cancer were ultimately included. The direct meta-analysis indicated that the length of hospital stay was longer after RTME than after taTME, whereas according to the reticulated meta-analysis the length of hospital stay was shorter after taTME than after laTME (MD=-0.86, 95%CI: -1.70 to -0.096, P=0.036). Moreover, the incidence of anastomotic leak was lower after taTME than after RTME (OR=0.60, 95%CI: 0.39 to 0.91, P=0.018). The incidence of intestinal obstruction was also lower after taTME than after RTME (OR=0.55, 95%CI: 0.31 to 0.94, P=0.037). All of these differences were statistically significant (all P<0.05). There were no statistically significant differences between the three surgical procedures regarding the number of lymph nodes cleared, length of the inferior rectal margin, or rate of positive circumferential margins (all P>0.05). An inconsistency test using nodal analysis revealed no statistically significant differences between the results of direct and indirect comparisons of the six outcome indicators (all P>0.05). Furthermore, we detected no significant overall inconsistency between direct and indirect evidence. Conclusion: taTME has advantages over RTME and laTME, in terms of radical and surgical short-term outcomes in patients with rectal cancer.
Humans
;
Robotics
;
Robotic Surgical Procedures/adverse effects*
;
Network Meta-Analysis
;
Retrospective Studies
;
Postoperative Complications/etiology*
;
Transanal Endoscopic Surgery/methods*
;
Rectum/surgery*
;
Rectal Neoplasms/pathology*
;
Laparoscopy/methods*
;
Treatment Outcome

Result Analysis
Print