1.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
2.An experimental study on distal locking of femoral intramedullary nail assisted by an intelligent orthopedic robot.
Kun WANG ; Cui XU ; Zhonghe WANG ; Junsong WANG ; Shaobo NIE ; Yanpeng ZHAO ; Wei ZHANG ; Ming HAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):129-133
OBJECTIVE:
To explore the advantages and effectiveness of the independently developed intelligent orthopedic robot-assisted distal locking of femoral intramedullary nails.
METHODS:
Thirty-two adult cadaveric femur specimens were randomly divided into two groups, with 16 specimens in each group. The experimental group used the intelligent orthopedic robot to assist in the distal locking of femoral intramedullary nail holes, while the control group used the traditional method of manual locking under X-ray fluoroscopy. The locking time, fluoroscopy times, and the success rate of first locking were recorded and compared between the two groups.
RESULTS:
The locking time of the experimental group was (273.94±38.67) seconds, which was shorter than that of the control group [(378.38±152.72) seconds], and number of fluoroscopies was (4.56±0.81) times, which was less than that of the control group [(8.00±3.98) times]. The differences were significant [ MD=73.054 (-37.187, 85.813), P=0.049; MD=1.969 (-1.437, 2.563), P=0.002]. The first locking success rate of the experimental group was 100% (16/16), which was significantly higher than that of the control group (68.75%, 11/16) ( P=0.043).
CONCLUSION
The efficiency of distal locking of femoral intramedullary nails assisted by the intelligent orthopedic robot is significantly higher than that of the traditional manual locking method under fluoroscopy, as it can markedly reduce the time required for distal locking of femoral intramedullary nails, decrease intraoperative radiation exposure, and increase the success rate of locking.
Humans
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Fluoroscopy
;
Femur/diagnostic imaging*
;
Femoral Fractures/surgery*
;
Robotic Surgical Procedures/instrumentation*
;
Cadaver
;
Adult
;
Robotics
;
Male
3.Effectiveness analysis of 5G remote robotic surgery in pelvic fracture treatment.
Yonghong DAI ; Kuangyang YANG ; Yanhui ZENG ; Wei HAN ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):391-398
OBJECTIVE:
To investigate the effectiveness of 5G remote robotic surgery in the treatment of pelvic fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 160 patients with pelvic fractures admitted between July 2023 and June 2024 who met the selection criteria. Among these patients, 80 underwent internal fixation surgery with the assistance of 5G remote robotic surgery (5G group), while 80 received local robotic surgical assistance (control group). Baseline characteristics, including gender, age, body mass index, disease duration, cause of injury, and fracture classification, were compared between the two groups, and no significant difference was found ( P>0.05). The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, maximum residual displacement postoperatively, quality of fracture reduction, incidence of complications, Majeed pelvic function score and classification at last follow-up were recorded and compared between the two groups.
RESULTS:
In the 5G group, 180 screws were implanted during surgery, while 213 screws were implanted in the control group. The 5G group demonstrated significantly reduced intraoperative blood loss and shorter incision length compared to the control group ( P<0.05). No significant difference was observed between the two groups in terms of operation time or hospital stay ( P>0.05). Radiographic evaluation revealed excellent and good reduction rates of 98.8% (79/80) in the 5G group and 97.5% (78/80) in the control group, while excellent and good screw placement accuracy rates were 98.3% (177/180) in the 5G group and 95.8% (204/213) in the control group. No significant difference was found between the two groups in maximum residual displacement, reduction quality, or screw placement accuracy ( P>0.05). All patients were followed up 7-16 months (mean, 11.3 months), with no significant difference in follow-up duration between the groups ( P>0.05). No perioperative or follow-up complication, such as wound infection, iatrogenic fractures, iatrogenic neurovascular injury, screw loosening or breakage, or nonunion, were observed in either group. The control group exhibited a worse degree of gait alteration compared to the 5G group ( P<0.05), while no significant difference was found in incidences of squatting limitation or persistent pain ( P>0.05). At last follow-up, no significant difference was observed between the groups in Majeed pelvic function scores or grading ( P>0.05).
CONCLUSION
Compared with the local surgery group, 5G remote robotic surgery supported by remote expert technical guidance demonstrated smaller incision lengths, less intraoperative blood loss, and fewer postoperative complications, and was shown to be a precise, minimally invasive, safe, and reliable surgical method.
Humans
;
Robotic Surgical Procedures/instrumentation*
;
Pelvic Bones/surgery*
;
Male
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Female
;
Fractures, Bone/surgery*
;
Middle Aged
;
Bone Screws
;
Adult
;
Operative Time
;
Treatment Outcome
;
Blood Loss, Surgical
;
Length of Stay
;
Postoperative Complications/epidemiology*
;
Aged
;
Young Adult
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.TiRobot-assisted minimally invasive treatment of geriatric fragility fractures of the pelvis.
Canhui LI ; Yonghong DAI ; Weiqiong CAI ; Xiaopeng SITU ; Yanhui ZENG ; Xuelian DU ; Shi HONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1421-1427
OBJECTIVE:
To investigate the effectiveness of TiRobot-assisted minimally invasive treatment for fragility fractures of the pelvis (FFP) in elderly patients.
METHODS:
A retrospective analysis was conducted on the clinical data of 176 patients with FFP who were admitted between July 2018 and July 2024 and met the selection criteria. Among them, 95 patients underwent TiRobot-assisted closed reduction and minimally invasive cannulated screw fixation (robot group), while 81 patients underwent traditional open reduction and plate screw fixation (control group). There was no significant difference in baseline data such as gender, age, fracture classification, disease duration, and preoperative visual analogue scale (VAS) pain scores between the two groups ( P>0.05). The following parameters were recorded and compared between the two groups, including operation time, intraoperative blood loss, intraoperative transfusion rate, volume of intraoperative blood transfusion, maximum incision length, hospital stay, maximum residual displacement, reduction quality, fracture healing time, incidence of complications, VAS scores, Majeed pelvic function scores, and functional grading.
RESULTS:
All surgeries in both groups successfully completed. The robot group exhibited significantly shorter operation time, reduced intraoperative blood loss, lower intraoperative transfusion rate, smaller volume of intraoperative blood transfusion, shorter maximum incision length, and shorter hospital stay compared to the control group ( P<0.05). In the robot group, a total of 14 INFIX internal fixation frames and 280 cannulated screws were implanted, among which 250 screws were rated as excellent, 17 as good, and 13 as poor, resulting in a screw placement excellent and good rate of 95.36%. Radiological review revealed that the excellent and good rate of reduction quality was in 91.58% (87/95) in the robot group and 81.48% (66/81) in the control group, with no significant difference in postoperative maximum residual fracture displacement or reduction quality between the two groups (P>0.05). All patients in both groups were followed up 12-66 months, with an average of 28.9 months, and there was no significant difference in follow-up time between the two groups ( P>0.05). The fracture healing time in the robot group was significantly shorter than that in the control group ( P<0.05). At last follow-up, both groups showed significant improvement in VAS scores compared to preoperative values ( P<0.05); the change values of VAS scores, Majeed scores, and the excellent and good rate of Majeed pelvic function were significantly higher in the robot group than in the control group ( P<0.05). Regarding postoperative complications, there was no significant difference between the two groups in terms of gait changes, secondary surgeries, heterotopic ossification, incision infections, walking difficulties, internal fixation failure, or mortality rates ( P>0.05); however, the incidence of delayed wound healing was significantly lower in the robot group than in the control group ( P<0.05).
CONCLUSION
TiRobot-assisted minimally invasive treatment of elderly FFP is superior to traditional open reduction and internal fixation in terms of surgical trauma control, postoperative rehabilitation speed, and functional recovery.
Humans
;
Male
;
Retrospective Studies
;
Female
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Fracture Fixation, Internal/instrumentation*
;
Pelvic Bones/surgery*
;
Aged
;
Bone Screws
;
Bone Plates
;
Robotic Surgical Procedures/methods*
;
Aged, 80 and over
;
Treatment Outcome
;
Osteoporotic Fractures/surgery*
;
Operative Time
;
Blood Loss, Surgical
;
Fracture Healing
;
Fractures, Bone/surgery*
6.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
7.Registration Method of Neurosurgical Robots Based on Ultra-Wideband Positioning Technology.
Chinese Journal of Medical Instrumentation 2025;49(5):479-485
With the continuous progress of medical technology, the application of stereotactic surgical robots in the field of neurosurgical operations has become increasingly extensive and important. This paper focuses on the registration principle of ultra-wideband positioning technology in stereotactic surgical robots during neurosurgical operations. It elaborates in detail on the processes of positioning and navigation, and illustrates different registration algorithms with examples. In addition, this paper looks ahead to the future development directions of ultra-wideband positioning technology in surgical robots, aiming to provide references for further development of surgical robots.
Neurosurgical Procedures/instrumentation*
;
Robotic Surgical Procedures/methods*
;
Algorithms
;
Robotics/methods*
8.Ion Robot-Assisted Bronchoscopy System and Its Applications.
Fei LI ; Zaozao WANG ; Xueyi LIU ; Qiaoqiao WANG ; Yunyun LI
Chinese Journal of Medical Instrumentation 2025;49(5):486-493
The peripheral pulmonary lesions are located far from the central airway and close to the pleura, so it is a challenge for clinical diagnosis of their nature through biopsy. Therefore, the Ion robot-assisted bronchoscopy system which has started its commercialization in China is proposed to diagnose and treat peripheral pulmonary lesions. The Ion system can be used for navigation, registration, biopsy and treatment. In this paper, the structural principle of the Ion system is expounded, and its technical advantages such as shape perception, slender catheter and flexible operation are summarized. It represents the latest development direction of the diagnosis and treatment of peripheral pulmonary lesions. Then, the clinical application and development status of the Ion system are analyzed and discussed in detail. Finally, the development trend of the robot-assisted bronchoscopy system is prospected, which provides new ideas for realizing the "integrated and one-stop" diagnosis and treatment services for peripheral pulmonary lesions based on this system.
Bronchoscopy/instrumentation*
;
Humans
;
Robotics
;
Robotic Surgical Procedures
9.Clinical efficacy of robot-assisted single-position OLIF with lateral plate combined with posterior unilateral fixation for single-segment lumbar spinal stenosis.
Yuekun FANG ; Zhilin YANG ; Haotian LI ; Weizhou WANG ; Hangchuang BI ; Bing WANG ; Junjie DONG ; Jin YANG ; Zhiqiang GONG ; Lingqiang CHEN
Journal of Central South University(Medical Sciences) 2025;50(1):119-129
OBJECTIVES:
Oblique lateral interbody fusion (OLIF) has become a well-established treatment for lumbar spinal stenosis (LSS) due to its advantages of being minimally invasive, effective, and associated with fewer complications. However, relying solely on lateral fixation provides limited strength and uneven load distribution. Conventional posterior bilateral fixation after OLIF typically requires intraoperative repositioning, increases fluoroscopy frequency, and involves extensive dissection of posterior muscles and soft tissues, resulting in greater trauma, blood loss, and risks of dural tear, nerve root injury, and persistent postoperative low back pain. This study aims to compare the clinical efficacy of robot-assisted single-position OLIF with lateral plating and posterior unilateral fixation, OLIF with lateral fixation alone, and OLIF combined with posterior bilateral fixation for treating single-segment LSS, and to explore how to enhance fixation stability, reduce trauma, and achieve precise minimally invasive outcomes without changing patient positioning.
METHODS:
A retrospective analysis was conducted on the clinical data from patients treated for single-segment LSS between January 2020 and June 2023 at the First Affiliated Hospital of Kunming Medical University. Patients were divided into 3 groups: Robot group (robot-assisted single-position OLIF with lateral plate and posterior unilateral fixation, 33 cases), lateral group (OLIF with lateral fixation alone, 52 cases), and combined group (OLIF with posterior bilateral fixation, 45 cases). Surgical time, intraoperative blood loss, fluoroscopy frequency, hospital stay, pedicle screw placement accuracy, and complication rates were recorded. Pain visual analogue scale (VAS) scores and Oswestry disability index (ODI) scores were assessed preoperatively, postoperatively, and at the final follow-up. Radiological evaluations (X-ray, computed tomography, and magnetic resonance imaging) measured interbody disc height (IDH), intervertebral foraminal height (IFH), and cross-sectional area (CSA) of the dural sac. Differences between pre- and postoperative imaging indices were statistically analyzed, and complication rates, fusion rates, and cage subsidence rates were recorded.
RESULTS:
All patients exhibited good positioning of internal fixation devices and cages, with significant symptom relief and no cases of spinal cord injury or symptom worsening. The follow-up time was (15.2±3.6) months. The operation time of the robot group was (70.62±8.99) min, which was longer than that of the lateral group (45.90±6.09) min and shorter than that of the combined group (110.12±8.44) min. The intraoperative blood loss of the robot group was (44.27±6.87) mL, which was more than that of the lateral group (33.58±9.73) mL and less than that of the combined group (79.19±10.35) mL. The number of intraoperative fluoroscopy times of the robot group was (9.49±2.25), which was comparable to that of the lateral group (7.45±2.02) but less than that of the combined group (12.24±4.25). The hospital stay of the robot group was (9.28±2.10) days, which was longer than that of the lateral group (7.95±1.91) days and shorter than that of the combined group (12.49±5.07) days. The screw placement accuracy of the robot group was 98.48%, which was higher than that of the combined group (90.55%). Postoperative and final follow-up VAS and ODI scores were significantly lower than preoperative scores in all 3 groups (all P<0.05), and there were no significant differences in preoperative VAS and ODI scores among the groups (all P>0.05). Radiologically, IDH, IFH, and CSA at the surgical segment were significantly increased postoperatively and at final follow-up compared to preoperatively and at final follow-up compared to preoperative values (all P<0.05), with no significant differences among the groups postoperatively (all P>0.05). Internal fixation remained stable during the follow-up period, and all cages achieved fusion at final follow-up. The intervertebral fusion rate of the robot-assisted group was 93.40%, which was similar to that of the combined group (95.56%) and higher than that of the lateral approach group (90.34%). The complication rate of the robot-assisted group was 6.1%, which was comparable to that of the combined group (8.9%) and lower than that of the lateral approach group (15.4%) (P<0.05). No cases of fixation loosening or breakage were observed throughout the follow-up period.
CONCLUSIONS
Robot-assisted single-position OLIF with lateral plate combined with posterior unilateral fixation effectively achieves indirect decompression and excellent spinal stability without the need for intraoperative repositioning. It provides high pedicle screw accuracy, reduces intraoperative blood loss, fluoroscopy times, and complication rates, offering a fully minimally invasive new treatment option for single-segment LSS.
Humans
;
Spinal Stenosis/surgery*
;
Robotic Surgical Procedures/methods*
;
Lumbar Vertebrae/surgery*
;
Spinal Fusion/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Bone Plates
;
Minimally Invasive Surgical Procedures/methods*
;
Adult
10.Application of domestic single-port robotic surgical system in thyroid cancer.
Qian MA ; Sicheng ZHANG ; Longyue ZHANG ; Jinyuan LIU ; Ronghao SUN ; Yuqiu ZHOU ; Linjie MA ; Chunyan SHUI ; Yongcong CAI ; Chao LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1044-1047
Objective:To explore the feasibility and preliminary efficacy of domestic single-port robotic surgical system in the surgical treatment of thyroid cancer. Methods:Thyroid cancer patients who underwent domestic single-port robotic surgery in the Department of Head and Neck Surgery of Sichuan Cancer Hospital from June 2024 to January 2025 were prospectively included. Clinical data, oncological characteristics, and perioperative indicators were systematically collected. Results:A total of 7 patients were included, including 3 males and 4 females, with an age of (34.57±10.26) years. All procedures were successfully completed without conversion to open surgery. Operative time was(180.00±30.41) minutes. Blood loss was(5.00[15.00 ])mL. Postoperative drainage volume was (167.86±130.95) mL. The postoperative pathological results were all thyroid papillary carcinoma. There were no system failures, no device-related complications and adverse events were observed during the operation and perioperative period. No tumor recurrence or metastasis was observed during the follow-up period. Conclusion:Preliminary data indicate that the domestic single-port robotic surgical system is safe and feasible for the surgical treatment of thyroid cancer, providing a practical basis for subsequent multi-disease, multi-center, and large-sample studies.
Humans
;
Thyroid Neoplasms/surgery*
;
Robotic Surgical Procedures/instrumentation*
;
Male
;
Female
;
Adult
;
Thyroidectomy/methods*
;
Operative Time
;
Middle Aged
;
Prospective Studies

Result Analysis
Print
Save
E-mail