1.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
2.Effect of respiratory filter on pulmonary function in occupational health examination.
Yi Ming SHI ; Liu DENG ; Jia Hui LI ; Ai Chu YANG ; Kai Sheng HUANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(1):35-38
Objective: To explore the influence and significance of respiratory filter on the judgment of pulmonary function and the conclusion of occupational health examination in occupational health examination. Methods: From August to November 2020, 252 occupational health examinees were randomly selected as the research objects, and the lung function was examined with the respiratory filter bite and the straight cylinder bite without filter, respectively. The lung function examination indexes and the qualification rate of lung function examination were analyzed and compared between the two groups, and the diagnostic criteria of lung function examination was corrected. Results: 252 subjects were 36 (30, 42) years old. The qualified rate of lung function examination with respiratory filter bite (28.17%, 71/252) was lower than that with straight cylinder bite (34.92%, 88/252) , the difference was statistically significant (P<0.05) . The percentage of forced vital capacity in normal predicted value (FVC%) , percentage of forced expiratory volume in the first second in normal predicted value (FEV(1)%) , and percentage of forced expiratory volume in the first second in forced vital capacity (FEV(1)/FVC%) of subjects using respiratory filter bite were lower than those using the straight cylinder bite (P<0.05) . The corrected diagnostic criteria of pulmonary function were FVC%>78%, FEV(1)%>77%, FEV(1)/FVC%>68%. There was no significant difference between the qualified rate of the respiratory filter bite lung function test calculated according to the corrected diagnostic criteria (35.71%, 90/252) and the qualified rate of the straight cylinder bite lung function test calculated according to the original diagnostic criteria (34.92%, 88/252) (P>0.05) . Conclusion: In occupational health examination, the use of respiratory filter may affect the results of pulmonary function examination. The diagnostic criteria of pulmonary function can be corrected according to different filtering effects to ensure the accuracy of the conclusions of occupational health examination.
Humans
;
Adult
;
Occupational Health
;
Lung
;
Vital Capacity
;
Forced Expiratory Volume
;
Respiratory Function Tests/methods*
3.Asthma management and asthma control level in children.
Chinese Journal of Contemporary Pediatrics 2023;25(1):73-79
OBJECTIVES:
To investigate the influencing factors for asthma management and asthma control level in children.
METHODS:
A total of 202 children with a confirmed diagnosis of asthma were enrolled. The questionnaire of asthma control level and family management was used to investigate the influencing factors for asthma control level and the indicators of family management. The awareness of childhood asthma and its management was analyzed among the parents, as well as the influence on asthma control level in children, and the association between them was analyzed.
RESULTS:
Compared with the non-complete control group, the complete control group had significantly longer course of asthma and treatment time (P<0.05). The proportions of asthma attacks ≥3 times and aerosol treatment for asthma attacks >3 times in one year in the complete control group were significantly lower than those in the non-complete control group (P<0.05). The complete control group had a significantly lower proportion of children with frequent respiratory infection, wheezing during respiratory infection, or a family history of allergic diseases (P<0.05). The parents in the complete control group had significantly stronger awareness of short-term escalation to asthma medication after respiratory infection and significantly enhanced management of maintenance medication (P<0.05). Compared with the complete control group, the non-complete control group had a significantly higher proportion of children with abnormal pulmonary function at the initial stage (P<0.05). The level of asthma control in children was associated with short-term escalation to asthma medication during respiratory infection and initial lung function (P<0.05).
CONCLUSIONS
The level of asthma control in children is closely associated with the severity of asthma and the comprehensive management of childhood asthma. Early treatment and family management, especially escalation to asthma medication during the early stage of respiratory infection, are of great importance in asthma control. Citation:Chinese Journal of Contemporary Pediatrics, 2023, 25(1): 73-79.
Child
;
Humans
;
Asthma/diagnosis*
;
Hypersensitivity/diagnosis*
;
Lung
;
Respiratory Tract Infections
;
Parents
;
Respiratory Sounds
4.Clinical characteristics and risk factors for bronchoscopic airway mucus hypersecretion in childhood pneumonia infected by different pathogens.
Jiang Yu CAI ; Chun Yu YAN ; Xiao Qing WANG ; Zheng Xiu LUO ; Jian LUO ; Qu Bei LI ; En Mei LIU ; Yu DENG
Chinese Journal of Pediatrics 2023;61(8):719-725
Objective: To investigate the risk factors for airway mucus hypersecretion in childhood pneumonia infected by different pathogens. Method: A retrospective cohort included 968 children who were hospitalized for Mycoplasma pneumoniae pneumonia (MPP), respiratory syncytial virus (RSV) pneumonia, adenovirus pneumonia and underwent bronchoscopy in Respiratory Department of Children's Hospital of Chongqing Medical University from January 2019 to December 2021 was conducted. The children were divided into two groups distinguished by airway mucus secretion according to the airway mucus hypersecretion score which were scored according to the mucus secretion under the bronchoscope. The demographic characteristics, clinical characteristics, laboratory tests and disease severity of the two groups were compared. And the risk factors for the development of airway mucus hypersecretion in two groups were analyzed. Chi square test, Mann-Whithey U test and Fisher exact test were used to analyze the differences between the two groups, and multivariate Logistic regression was used to analyze the influencing factors. Result: There were 559 males and 409 females in the 968 children, with an age of 4.0 (1.4, 6.0) years. Among the 642 children with MPP, 185 cases were in the hypersecretion group and 457 cases were in the non-hypersecretion group. There were 41 cases in the hypersecretion group and 160 cases in the non-hypersecretion group of 201 children with RSV pneumonia. In the 125 children with adenovirus pneumonia, there were 39 cases in the hypersecretion group and 86 cases in the non-hypersecretion group. In these children, the age of children in the hypersecretion group was older than that in the non-hypersecretion group (6.0 (4.0, 7.0) vs. 5.0 (3.0, 7.0) years old, 1.5 (0.5, 3.6) vs. 0.8 (0.4, 1.6) years old, 2.0 (1.2, 4.5) vs. 1.3 (0.8, 2.0) years old, U=35 295.00, 2 492.00, 1 101.00, all P<0.05). Through multivariate Logistic regression analysis it found that increased risk of airway mucus hypersecretion was present in childhood MPP with increase in peripheral blood white blood cell count (OR=3.30, 95%CI 1.51-7.93, P=0.004) or increase in neutrophil ratio (OR=2.24, 95%CI 1.16-4.33, P=0.016) or decrease in lymphocyte count (OR=3.22, 95%CI 1.66-6.31, P<0.001) or decrease in serum albumin (OR=2.00, 95%CI 1.01-3.98, P=0.047). The risk of airway mucus hypersecretion was increased in children with RSV pneumonia combined with elevated peripheral blood eosinophils (OR=3.04, 95%CI 1.02-8.93, P=0.043). Meanwhile, airway mucus hypersecretion was associated with severe pneumonia (OR=2.46, 95%CI 1.03-6.15, P=0.047) in children with RSV pneumonia. Older age was associated with increased risk of airway mucus hypersecretion in children with adenovirus pneumonia (OR=1.02, 95%CI 1.00-1.04, P=0.026). In these children with occurrence of pulmonary rales, wheezes or sputum sounds (OR=3.65, 95%CI 1.22-12.64, P=0.028) had an increased risk of airway mucus hypersecretion. Neutrophils in bronchoalveolar lavage fluid (BALF) demonstrated higher ratio in hypersecretion group from children with MPP (0.65 (0.43, 0.81) vs. 0.59 (0.34, 0.76), U=24 507.00, P<0.01), while the proportion of macrophages in BALF was lower (0.10 (0.05, 0.20) vs. 0.12 (0.06, 0.24), U=33 043.00, P<0.05). Nucleated cell count and neutrophil ratio in BALF were higher in hypersecretion group of children with RSV pneumonia (1 210 (442, 2 100)×106 vs. 490 (210, 1 510)×106/L, 0.43 (0.26, 0.62) vs. 0.30 (0.13, 0.52), U=2 043.00, 2 064.00, all P<0.05). Conclusions: The increase in peripheral blood white blood cell count, neutrophil ratio and decrease in lymphocyte count, serum albumin in children with MPP is related to the development of airway mucus hypersecretion. In children with RSV pneumonia, the abnormal increase of eosinophils in peripheral blood has relationship with hypersecretion. The appearance of lung rale, wheezing, and sputum rale are associated with airway mucus hypersecretion in children with adenovirus pneumonia. In addition, local neutrophil infiltration in the respiratory tract is closely related to the occurrence of airway mucus hypersecretion caused by Mycoplasma pneumoniae and RSV infection.
Child
;
Male
;
Female
;
Humans
;
Infant
;
Child, Preschool
;
Retrospective Studies
;
Respiratory Sounds
;
Pneumonia, Mycoplasma
;
Lung
;
Respiratory Syncytial Virus Infections
;
Mucus
;
Pneumonia, Viral
;
Risk Factors
6.Development of a Multi-parameter Pulmonary Function Test System.
Xilin YE ; Yueming CHEN ; Jilun YE ; Bing LIU
Chinese Journal of Medical Instrumentation 2023;47(3):268-271
To comprehensively evaluate the human body's respiratory, circular metabolism and other functions, and to diagnose lung disease, an accurate and reliable pulmonary function test (PFT) is developed. The system is divided into two parts:hardware and software. It realizes the collection of respiratory, pulse oxygen, carbon dioxide, oxygen and other signals, and draws flow-volume curve (FV curve), volume-time curve (VT curve), respiratory waveform, pulse wave, carbon dioxide and oxygen waveform in real time on the upper computer of the PFT system, and conducts signal processing and parameter calculation for each signal. The experimental results prove that the system is safe and reliable, it can accurately measure the basic functions of human body, and provide reliable parameters, and has good application prospects.
Humans
;
Carbon Dioxide
;
Respiratory Function Tests
;
Oxygen
;
Heart Rate
7.Research and Development Trend of Medical Oxygen Production Equipment.
Hangduo NIU ; Zifu ZHU ; Dandan HU ; Shengcai MA ; Ruowei LI ; Sinian YUAN ; Jilun YE ; Hao JIN
Chinese Journal of Medical Instrumentation 2023;47(3):294-297
Oxygen therapy is an effective clinical method for the treatment of respiratory disorders, oxygen concentrator as a necessary medical auxiliary equipment in hospitals, its research and development has been a hot spot. The study reviewed the development history of the ventilator, introduced the two preparation technique of the oxygen generator pressure swing absorption (PSA) and vacuum pressure swing adsorption (VPSA), and analyzed the core technology development of the oxygen generator. In addition, the study compared some major brands of oxygen concentrators on the market and prospected the development trend of oxygen concentrators.
Oxygen
;
Oxygen Inhalation Therapy
;
Hospitals
;
Ventilators, Mechanical
;
Equipment Design
8.Design and application of decompression fixator to prevent HFNC facial pressure injury.
Chinese Critical Care Medicine 2023;35(7):762-763
As a new respiratory support technique, high-flow nasal cannula oxygen therapy (HFNC) has been widely used in clinical practice in recent years. During HFNC treatment, due to the long time and continuous wearing of nasal stopper and fasteners on the patient face, it is easy to cause medical device-related pressure injury on multiple facial skin. Moreover, when the patient's position changes greatly, because there is no good fixed design at the HFNC nasal stopper, it is easy to shift or turn the nasal stopper outward, causing abnormal ventilation and failure to achieve the purpose of clinical oxygen therapy. To overcome above problems, medical staff in the intensive care unit of department of infectious diseases, Tongji Hospital Tongji Medical College of HUST designed a new type of decompression fixator to prevent HFNC face pressure injury, and obtained national utility model patent (ZL 2022 2 0754626.1). The integrated design structure of the device has the functions of decompression of facial skin and fixation of nasal stopper, which can ensure the effect of oxygen therapy and improve the oxygen therapy experience and patient comfort, which is suitable for clinical promotion.
Humans
;
Cannula
;
Pressure Ulcer/prevention & control*
;
Oxygen Inhalation Therapy/methods*
;
Oxygen
;
Decompression
;
Respiratory Insufficiency/therapy*
;
Noninvasive Ventilation
9.Consensus recommendations on the evaluation and treatment of laryngotracheal anomalies in infants and young children.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(6):403-408
Infants with laryngotracheal anomalies are clinically manifested as stridor or noisy breathing, choking, hoarseness, feeding difficulties, and cyanotic spells, followed by developmental and growth retardation and other health issues; in severe cases, patients may present with severe dyspnea, which is associated with high mortality. A timely diagnosis as well as appropriate strategy for laryngotracheal anomalies is still challenging for pediatric otolaryngologists. This consensus statement, evolved from expert opinion by the members of the Pediatric Otorhinolaryngology Professional Committee of the Pediatrician Branch of the Chinese Medical Doctor Association, provides comprehensive recommendations and standardized guidance for otolaryngologists who manage infants and young children with laryngotracheal anomalies in evaluation and treatment based on symptomatology, physical and laboratory examinations.
Humans
;
Child
;
Infant
;
Child, Preschool
;
Laryngostenosis/surgery*
;
Airway Obstruction/complications*
;
Hoarseness/complications*
;
Consensus
;
Respiratory Sounds

Result Analysis
Print
Save
E-mail