1.Traditional Chinese Exercise Improves Lung Function and Exercise Capacity in Patients with Preserved Ratio Impaired Spirometry.
Yan-Yi LIU ; Gai-Hua HOU ; Kun XIA ; Xiao-Yan YAO ; Yi WANG ; Guang-Xi LI
Chinese journal of integrative medicine 2025;31(12):1113-1118
OBJECTIVE:
To investigate the effect of traditional Chinese Five-body balance exercise on patients with preserved ratio impaired spirometry (PRISm).
METHODS:
Fifteen patients with PRISm and 15 patients diagnosed with chronic obstructive pulmonary disease (COPD) were recruited from the Outpatient Department of Guang'anmen Hospital and Beijing Niujie Health Service Center from April to December, 2023. Participants in both groups attended supervised Five-body balance exercise training twice a week for 12 weeks. Patients with COPD continued their regular medication regimen during the intervention period. The endpoints were mean changes in the 6-min walk test (6MWT), St. George's Respiratory Questionnaire (SGRQ) score, cardiopulmonary exercise testing (CPET), pulmonary function, and scores of COPD assessment test (CAT), modified British Medical Research Council, Self-Rating Anxiety Scale, and Self-Rating Depression Scale from baseline to 12 weeks. Adverse events were monitored throughout the study.
RESULTS:
The PRISm group showed a significant improvement from baseline to week 12 in 6MWT, SGRQ symptom score, and forced vital capacity (FVC) compared to the COPD group (P<0.05). No significant between-group changes were observed in other outcome measurements (P>0.05). In addition, compared with baseline, both groups exhibited improvements in 6MWT, SGRQ score, and CPET at week 12 (P<0.05). The PRISm group also showed a significant increase in forced expiratory volume in 1 s and FVC, as well as a significant decrease in CAT score at week 12 (P<0.05). No adverse events were reported.
CONCLUSION
Patients with PRISm may benefit from Five-body balance exercise training, which can improve the exercise capacity, health-related quality of life, and lung function. (Registration No. ChiCTR2200059290).
Humans
;
Spirometry
;
Male
;
Female
;
Pulmonary Disease, Chronic Obstructive/therapy*
;
Lung/physiopathology*
;
Middle Aged
;
Exercise Tolerance/physiology*
;
Exercise Therapy
;
Aged
;
Medicine, Chinese Traditional
;
Respiratory Function Tests
;
East Asian People
2.Analysis of clinical features of ruccrent interstitial lung disease in patients with anti-EJ positive antisynthetase syndrome.
Yujing ZHU ; Lei WANG ; Chengyin LYU ; Wenfeng TAN ; Miaojia ZHANG
Journal of Peking University(Health Sciences) 2024;56(6):980-986
OBJECTIVE:
To summarize the clinical characteristics of 57 patients diagnosed with anti-glycyl tRNA synthetase (anti-EJ) positive antisynthetase syndrome (ASS), a subtype of anti-glycyl tRNA positive ASS, complicated by interstitial lung disease (ILD), and to investigate the factors asso-ciated with ILD recurrence.
METHODS:
A retrospective analysis was conducted on the clinical data of 57 anti-EJ positive ASS patientswho were treated at the First Affiliated Hospital of Nanjing Medical University from January 1, 2020 to June 30, 2024. The data collected included demographic information, clinical characteristics, laboratory test results, chest CT findings, and pulmonary function tests. The characteristics of ILD recurrence were also analyzed.
RESULTS:
All the 57 patients with anti-EJ positive ASS were diagnosed with ILD. The mean age at disease onset was (58.18±10.27) years, with a mean disease duration of 3.00 (2.00, 16.00) months. Among the patients, 70. 18% were female, 87.72% experienced a cough, 70. 18% had expectoration, 89.47% reported respiratory difficulties, and 14.04% developed respiratory failure. The results of pulmonary function test showed that the percentage of forced vital capacity (FVC) in the normal predicted value (FVC%), the percentage of forced expiratory volume in the first second (FEV1) in the normal predicted value (FEV1%) and the percentage of diffusion lung carbon monoxide (DLCO) in the normal predicted value (DLCO%) were 59.36±21.41, 58.34±19.46 and 58.17±27.95, respectively. The oxygenation index was (363.24±99.42) mmHg. Chest CT imaging showed that nonspecific interstitial pneumonia (NSIP) was the most common radiographic pattern. Among the 46 patients who completed a follow-up of more than 12 months, 21 cases (45.65%) showed recurrence of ILD. The average age of onset for the recurrence group was (61.38±8.63) years, while that for the non-recurrence group was (55.28±11.85) years, with a difference approaching statistical significance (P=0.056). Further analysis showed that the ESR (erythrocyte sedimentation rate) level was significantly higher in the recurrence group than in the non-recurrence group [(50.48±29.64) mm/h vs. 30.28±23.97) mm/h, P=0.025], and the IgM (immune globulin M) level was also significantly higher in the recurrence group (P=0.042). Moreover, the CD8+T proportion was significantly higher in the recurrence group than in the non-recurrence group (25.48±11.81 vs. 18.59± 8.53, P=0.027). Despite the fact that the recurrence group had a higher baseline age, higher ESR, IgM, and CD8+T proportion, multivariate binary logistic regression analysis showed that these indicators were not independent risk factors for ILD recurrence.
CONCLUSION
ILD is the most common clinical manifestation in patients with anti-EJ positive ASS, with a significant impact on pulmonary function. Although the patients responded well to a combination of glucocorticoid and immunosuppressive therapies, the recurrence rate remains high, particularly in those with increased sputum production, and elevated ESR. Close monitoring and early intervention for high-risk patients are essential to improving long-term outcomes.
Humans
;
Lung Diseases, Interstitial
;
Female
;
Male
;
Middle Aged
;
Retrospective Studies
;
Myositis/diagnosis*
;
Respiratory Function Tests
;
Glycine-tRNA Ligase
;
Recurrence
;
Aged
;
Tomography, X-Ray Computed
;
Autoantibodies/blood*
3.Effect of respiratory filter on pulmonary function in occupational health examination.
Yi Ming SHI ; Liu DENG ; Jia Hui LI ; Ai Chu YANG ; Kai Sheng HUANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(1):35-38
Objective: To explore the influence and significance of respiratory filter on the judgment of pulmonary function and the conclusion of occupational health examination in occupational health examination. Methods: From August to November 2020, 252 occupational health examinees were randomly selected as the research objects, and the lung function was examined with the respiratory filter bite and the straight cylinder bite without filter, respectively. The lung function examination indexes and the qualification rate of lung function examination were analyzed and compared between the two groups, and the diagnostic criteria of lung function examination was corrected. Results: 252 subjects were 36 (30, 42) years old. The qualified rate of lung function examination with respiratory filter bite (28.17%, 71/252) was lower than that with straight cylinder bite (34.92%, 88/252) , the difference was statistically significant (P<0.05) . The percentage of forced vital capacity in normal predicted value (FVC%) , percentage of forced expiratory volume in the first second in normal predicted value (FEV(1)%) , and percentage of forced expiratory volume in the first second in forced vital capacity (FEV(1)/FVC%) of subjects using respiratory filter bite were lower than those using the straight cylinder bite (P<0.05) . The corrected diagnostic criteria of pulmonary function were FVC%>78%, FEV(1)%>77%, FEV(1)/FVC%>68%. There was no significant difference between the qualified rate of the respiratory filter bite lung function test calculated according to the corrected diagnostic criteria (35.71%, 90/252) and the qualified rate of the straight cylinder bite lung function test calculated according to the original diagnostic criteria (34.92%, 88/252) (P>0.05) . Conclusion: In occupational health examination, the use of respiratory filter may affect the results of pulmonary function examination. The diagnostic criteria of pulmonary function can be corrected according to different filtering effects to ensure the accuracy of the conclusions of occupational health examination.
Humans
;
Adult
;
Occupational Health
;
Lung
;
Vital Capacity
;
Forced Expiratory Volume
;
Respiratory Function Tests/methods*
4.Development of a Multi-parameter Pulmonary Function Test System.
Xilin YE ; Yueming CHEN ; Jilun YE ; Bing LIU
Chinese Journal of Medical Instrumentation 2023;47(3):268-271
To comprehensively evaluate the human body's respiratory, circular metabolism and other functions, and to diagnose lung disease, an accurate and reliable pulmonary function test (PFT) is developed. The system is divided into two parts:hardware and software. It realizes the collection of respiratory, pulse oxygen, carbon dioxide, oxygen and other signals, and draws flow-volume curve (FV curve), volume-time curve (VT curve), respiratory waveform, pulse wave, carbon dioxide and oxygen waveform in real time on the upper computer of the PFT system, and conducts signal processing and parameter calculation for each signal. The experimental results prove that the system is safe and reliable, it can accurately measure the basic functions of human body, and provide reliable parameters, and has good application prospects.
Humans
;
Carbon Dioxide
;
Respiratory Function Tests
;
Oxygen
;
Heart Rate
5.Analysis of related factors for postoperative recurrence of antrochoanal polyps in children.
Yijun CHEN ; Yingqin GAO ; Jing MA ; Meilan WANG ; Guo LI ; Zhengcai LI ; Tiesong ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(6):463-468
Objective:To analyze the correlation between nasal resistance and lung function in children with allergic rhinitis(AR), and explore whether AR children with increased nasal resistance are accompanied by potential lower respiratory tract involvement. Methods:A total of 88 children diagnosed with AR from December 2021 to December 2022 were selected as the study group, while 20 normal children were selected as the control group during the same period. Both the study group and the control group children underwent lung function tests, bronchodilator tests, and nasal resistance measurements. Spearman correlation analysis and multiple linear regression analysis were performed on the results of nasal resistance and lung function tests to explore the relationship and influencing factors between the two groups.According to the results of nasal resistance measurement, children with increased nasal resistance and abnormal lung function were divided into a mild increase in nasal resistance with abnormal lung function group and a moderate to severe increase in nasal resistance with abnormal lung function group. The degree of increased nasal resistance was analyzed to determine whether it would affect lung function. Results:The FEF25, FEF50, and FEF75 levels in the study group were significantly lower than those in the control group(P<0.05). The FEV1of children with moderate to severe increase in AR nasal resistance was significantly lower than that of children with mild increase in AR nasal resistance(P<0.05). There was a correlation between nasal resistance and FEV1/FVC, R20 in AR children, and FEV1/FVC, R20 were the influencing factors of nasal resistance in AR children(P<0.05). There was no correlation between total serum IgE, lung function, and bronchodilation test in AR patients(P>0.05). Conclusion:The nasal ventilation function of AR patients has changed, and there is a downward trend in small airway function. Children with moderate to severe increase in AR nasal resistance have a more significant decrease in lung ventilation function than those with mild increase. The nasal resistance of AR children is influenced by FEV1/FVC and R20, and FEV1/FVC and R20 decrease as the nasal resistance value increases. The improvement rate of lung function and FEV1 are not influencing factors for the elevation of total serum IgE.
Humans
;
Child
;
Rhinitis, Allergic/diagnosis*
;
Nasal Polyps
;
Respiratory Function Tests
;
Nose
;
Immunoglobulin E
6.Performance of pulmonary function test in people aged 40 years and above in China, 2019-2020.
He TONG ; Shu CONG ; Li Wen FANG ; Jing FAN ; Ning WANG ; Qing Qing ZHAO ; Jing WU
Chinese Journal of Epidemiology 2023;44(5):727-734
Objective: To understand the performance of pulmonary function tests in people aged ≥40 years and its changes in China, and provide evidence for the evaluation of the effect of chronic obstructive pulmonary disease (COPD) prevention and control in China. Methods: The subjects of the survey were from COPD surveillance during 2014-2015 and during 2019-2020, which covered 31 provinces (autonomous regions and municipalities) in China. The survey used multi-stage stratified cluster random sampling method, the trained investigators conducted face-to-face interview to know whether subjects had previous pulmonary function testing or not. Complex sampling weighting was used to estimate the rate of pulmonary function testing in people aged ≥40 years, and the pulmonary function testing rates of the two COPD surveillance periods were compared. Results: A total of 148 427 persons were included in the analysis, including 74 591 persons during 2014-2015 and 73 836 persons during 2019-2020. In 2019-2020, the pulmonary function testing rate in Chinese residents aged ≥40 years was 6.7% (95%CI: 5.2%-8.2%), the rate in men (8.1%, 95%CI: 6.7%-9.6%) was higher than that in women (5.4%, 95%CI: 3.7%- 7.0%), and the rate in urban residents (8.3%, 95%CI: 6.1%-10.5%) was higher than that in rural residents (4.4%, 95%CI: 3.8%-5.1%). The rate of pulmonary function testing increased with the increase of education level. During 2019-2020, the residents with history of chronic respiratory diseases had the highest rate of pulmonary function testing (21.2%, 95%CI: 16.8%-25.7%), followed by the residents with respiratory symptoms (15.1%, 95%CI: 11.8%-18.4%) , the pulmonary function testing rate in those who knew the name of chronic respiratory disease was higher than that in those who did not knew the name of respiratory disease, and the pulmonary function testing rate in former smokers was higher than that in current smokers and non-smokers. Those exposed to occupational dust and/or harmful gases had a higher rate of pulmonary function testing compared with those who were not exposed, and those who used polluted fuels indoors had a lower rate of pulmonary function testing than those who did not use polluted fuels indoors (all P<0.05). Compared with 2014-2015, the pulmonary function testing rate in residents aged ≥40 years in China increased by 1.9 percentage points during 2019-2020, and the rate of pulmonary function testing in groups with different characteristics all increased, and the rates of pulmonary function testing increased by 7.4 percentage points and 7.1 percentage points in residents with respiratory symptoms and in those with history of chronic respiratory diseases (all P<0.05). Conclusions: Compared with 2014-2015, the rate of pulmonary function testing increased in China during 2019-2020 and the increase in residents with history of chronic respiratory diseases and respiratory symptoms was relatively obvious, but the overall pulmonary function testing rate was still at a low level. Effective measures should be taken to further increase the rate of pulmonary function testing.
Female
;
Humans
;
Male
;
Asian People
;
China
;
Dust
;
Pulmonary Disease, Chronic Obstructive
;
Respiratory Function Tests
;
Adult
7.Relationship between cadmium exposure and pulmonary function level and chronic obstructive pulmonary disease.
Hong Xia KE ; Jian Ping ZHANG ; Si Hui JIN ; Li ZHOU ; Shou Fan CHAI ; Li MA
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(4):241-246
Objective: To analyze the levels and distribution characteristics of blood cadmium and urinary cadmium in American adults, to analyze the relationship between blood cadmium and urinary cadmium and pulmonary function dose response, and to explore the effect of this index on the risk of chronic obstructive pulmonary disease. Methods: In March 2022, 3785 patients from 2007 to 2012 in NHANES database were selected as the subjects. Collect demography data such as gender and age, and test data such as lung function, blood cadmium concentration and Urine cadimium concentration. The relationship between blood and urine cadmium levels and lung function and pulmonary function and chronic obstructive pulmonary diease (COPD) was analyzed by Mann-Whitney U test or Kruskal-Wallis H test, multivariate linear regression and restricted cubic spline method. Results: The geometric mean of blood cadmium and urine cadmium in American adults was 0.37 g/L and 0.28 g/L, FEV(1) and FEV(1)/FVC among different cadmium exposure groups was statistically significant, and there was a negative linear dose-response relationship between serum Cd and urine Cd concentrations and FEV(1)/FVC levels (P(overall)<0.001, P(non-linear)=0.152; P(overall)<0.001, P(non-linear)=0.926). Compared with the lowest quartile concentration (Q1), the highest quartile blood cadmium concentration (Q4) (OR=1.934, P(trend)=0.000) and urinary cadmium concentration (OR=1.683, P(trend)=0.000) may increased the risk of chronic obstructive pulmonary disease. Conclusion: There is a negative correlation between blood cadmium, urinary cadmium levels and lung function in American adults, and cadmium may increase the risk of chronic obstructive pulmonary disease.
Adult
;
Humans
;
Cadmium
;
Nutrition Surveys
;
Lung
;
Pulmonary Disease, Chronic Obstructive
;
Respiratory Function Tests
8.Thumb-tack needles based on "Biaoben acupoint compatibility" for sequela of COVID-19 during recovery period.
Zhi-Hui LUO ; Kun-Xiu WANG ; Yan-Lin ZHANG ; Zi-Qin CHEN ; Bei CHEN ; Jia CHEN ; Ting ZHOU ; Xiao-Lei GU ; Chong-Li LI ; Peng YAN ; Ling-Ling TIAN ; Chi-Cheng XU ; Bo-Lin CHEN ; Song CHEN
Chinese Acupuncture & Moxibustion 2022;42(3):281-286
OBJECTIVE:
To observe the effect of thumb-tack needles based on "Biaoben acupoint compatibility" on sequela symptoms, mental state and pulmonary ventilation function in patients with coronavirus disease 2019 (COVID-19) during recovery period.
METHODS:
Fifty cases of COVID-19 during recovery period were randomly divided into an observation group and a control group, 25 cases in each group. The patients in the observation group were treated with thumb-tack needles at Guanyuan (CV 4), Zusanli (ST 36) and Taiyuan (LU 9). The patients in the control group were treated with sham thumb-tack needles at identical acupoints as the observation group. The treatment in the two groups was given once a day, 7-day treatment was taken as a course of treatment, and totally two courses of treatment were given. The TCM symptom score, Hamilton anxiety scale (HAMA) score, Hamilton depression scale (HAMD) score, pulmonary function (forced vital capacity [FVC], forced expiratory volume in the first second [FEV1], peak expiratory flow [PEF]), the severity of pulmonary ventilation dysfunction and pulmonary imaging changes in the two groups were compared before and after treatment.
RESULTS:
Compared before treatment, the total scores and each item scores of TCM symptom scale, HAMA scores and HAMD scores in the two groups were reduced after treatment (P<0.05). Except for the symptom scores of dry throat and dry stool, the total score and each item score of TCM symptom scale, HAMA score and HAMD score in the observation group were lower than those in the control group (P<0.05). Compared before treatment, FVC, FEV1 and PEF in the two groups were increased after treatment (P<0.05), and those in the observation group were higher than the control group (P<0.05). The severity of pulmonary ventilation dysfunction in the two groups was reduced after treatment (P<0.05), and the severity in the observation group was better than that in the control group (P<0.05). After treatment, the lung shadow area in the two groups was decreased (P<0.05), and that in the observation group was smaller than the control group (P<0.05). The improvement of imaging change in the observation group was better than that in the control group (P<0.05).
CONCLUSION
The thumb-tack needles based on "Biaoben acupoint compatibility" could significantly reduce the sequela symptoms, anxiety and depression in patients with COVID-19 during recovery stage, and improve the pulmonary ventilation function.
Acupuncture Points
;
Anxiety/etiology*
;
COVID-19/therapy*
;
Depression/etiology*
;
Humans
;
Needles
;
Respiratory Function Tests
;
Thumb
9.Meta-analysis of efficacy and safety of Suhuang Zhike Capsules in treatment of chronic obstructive pulmonary disease.
Rui-Heng ZHAO ; Jing HAN ; Ze-Lu HAN ; Shu-Hua ZHANG ; Jiang-Tao LIN
China Journal of Chinese Materia Medica 2022;47(4):1095-1102
This study aims to evaluate the effectiveness and safety of Suhuang Zhike Capsules in treating chronic obstructive pulmonary disease. The Chinese and English databases were searched(from the establishment to July 2021) for randomized controlled trials(RCTs) on the treatment of chronic obstructive pulmonary disease with Suhuang Zhike Capsules, yielding 130 articles and finally 12 eligible RCTs. The 12 RCTs enrolled a total of 1 159 patients(579 in experimental group, 580 in control group), with 728 males(62.8%) and 431 females(37.2%). Meta-analysis showed that the conventional western medicine combined with Suhuang Zhike Capsules increased clinical efficacy(OR=4.31, 95%CI[2.88, 6.46], Z=7.08, P<0.000 01), forced expiratory volume in one second(FEV1)(SMD=0.88, 95%CI[0.60, 1.16], Z=6.24, P<0.000 01), forced vital capacity(FVC)(SMD=0.96, 95%CI[0.38, 1.55], Z=3.22, P=0.001), forced vital capacity rate of one second(FEV1/FVC%)(SMD=0.85, 95%CI[0.51, 1.19], Z=4.92, P<0.000 01), and maximum voluntary ventilation(MVV)(SMD=0.61, 95%CI[0.39, 0.83], Z=5.40, P<0.000 01) compared with the conventional western medicine alone. The differences in residual volume/total lung capacity(RV/TLC)(SMD=-0.93, 95%CI[-3.38, 1.53], Z=0.74, P=0.46) and adverse reactions(OR=1.39, 95%CI[0.76, 2.56], Z=1.07, P=0.28) are insignificant. The study showed that the conventional western medicine combined with Suhuang Zhike Capsules could improve clinical efficacy and lung functions in the treatment of chronic obstructive pulmonary disease. In addition, the combination had been verified to be safe. However, in view of the uneven method quality, small sample size, and inconsistent outcome indicators of the included studies, higher-quality, multi-center, and large-sample RCTs are needed for further verification.
Capsules
;
Female
;
Forced Expiratory Volume
;
Humans
;
Lung
;
Male
;
Pulmonary Disease, Chronic Obstructive/drug therapy*
;
Respiratory Function Tests
10.Correlation Analysis of the Lung Volume Reduction and the Lung Function Loss after the Thoracoscopic Lobectomy.
Zhenzhou ZHAI ; Jun ZHAO ; Chang LI ; Cheng DING ; Chun XU
Chinese Journal of Lung Cancer 2022;25(1):21-25
BACKGROUND:
To investigate the correlation between the reduction of lung volume and the degree of lung function damage after lobectomy.
METHODS:
A total of 131 patients (72 males and 59 females) who underwent thoracoscopic lobectomy in the First Affiliated Hospital of Suzhou University from January 2019 to July 2020 (including thoracoscopic resection of left upper lobe, left lower lobe, right upper lobe, right middle lobe and right lower lobe). In order to compare the difference between postoperative pulmonary function and preoperative pulmonary function, the pulmonary function measurements were recorded at 7 days before operation, and 3 months, 6 months and 1 year after operation. Forced expiratory volume in 1 second (FEV1) was used as the main evaluation parameter of pulmonary function. The original lung volume and the remaining lung volume at each stage were calculated by Mimics Research 19.0 software. The correlation between lung volume and lung function was analyzed.
RESULTS:
FEV1 in postoperative patients was lower than that before operation, and the degree of decline was positively correlated with the resection volume of lung lobes (the maximum value was shown in the left lower lobe group). Significantly, there was no significant difference in the degree of pulmonary function reduction between 3 months, 6 months and 1 year after operation.
CONCLUSIONS
The decrease of lung tissue volume after lobectomy is the main reason for the decrease of lung function, especially in the left lower lobe. And 3 months after lobectomy can be selected as the evaluation node of residual lung function.
Carcinoma, Non-Small-Cell Lung/surgery*
;
Female
;
Forced Expiratory Volume
;
Humans
;
Lung/surgery*
;
Lung Neoplasms/surgery*
;
Male
;
Pneumonectomy/adverse effects*
;
Respiratory Function Tests

Result Analysis
Print
Save
E-mail