1.Multicenter evaluation of the diagnostic efficacy of jaundice color card for neonatal hyperbilirubinemia
Guochang XUE ; Huali ZHANG ; Xuexing DING ; Fu XIONG ; Yanhong LIU ; Hui PENG ; Changlin WANG ; Yi ZHAO ; Huili YAN ; Mingxing REN ; Chaoying MA ; Hanming LU ; Yanli LI ; Ruifeng MENG ; Lingjun XIE ; Na CHEN ; Xiufang CHENG ; Jiaojiao WANG ; Xiaohong XIN ; Ruifen WANG ; Qi JIANG ; Yong ZHANG ; Guijuan LIANG ; Yuanzheng LI ; Jianing KANG ; Huimin ZHANG ; Yinying ZHANG ; Yuan YUAN ; Yawen LI ; Yinglin SU ; Junping LIU ; Shengjie DUAN ; Qingsheng LIU ; Jing WEI
Chinese Journal of Pediatrics 2024;62(6):535-541
Objective:To evaluate the diagnostic efficacy and practicality of the Jaundice color card (JCard) as a screening tool for neonatal jaundice.Methods:Following the standards for reporting of diagnostic accuracy studies (STARD) statement, a multicenter prospective study was conducted in 9 hospitals in China from October 2019 to September 2021. A total of 845 newborns who were admitted to the hospital or outpatient department for liver function testing due to their own diseases. The inclusion criteria were a gestational age of ≥35 weeks, a birth weight of ≥2 000 g, and an age of ≤28 days. The neonate′s parents used the JCard to measure jaundice at the neonate′s cheek. Within 2 hours of the JCard measurement, transcutaneous bilirubin (TcB) was measured with a JH20-1B device and total serum bilirubin (TSB) was detected. The Pearson′s correlation analysis, Bland-Altman plots and the receiver operating characteristic (ROC) curve were used for statistic analysis.Results:Out of the 854 newborns, 445 were male and 409 were female; 46 were born at 35-36 weeks of gestational age and 808 were born at ≥37 weeks of gestational age. Additionally, 432 cases were aged 0-3 days, 236 cases were aged 4-7 days, and 186 cases were aged 8-28 days. The TSB level was (227.4±89.6) μmol/L, with a range of 23.7-717.0 μmol/L. The JCard level was (221.4±77.0) μmol/L and the TcB level was (252.5±76.0) μmol/L. Both the JCard and TcB values showed good correlation ( r=0.77 and 0.80, respectively) and agreements (96.0% (820/854) and 95.2% (813/854) of samples fell within the 95% limits of agreement, respectively) with TSB. The JCard value of 12 had a sensitivity of 0.93 and specificity of 0.75 for identifying a TSB ≥205.2?μmol/L, and a sensitivity of 1.00 and specificity of 0.35 for identifying a TSB ≥342.0?μmol/L. The TcB value of 205.2?μmol/L had a sensitivity of 0.97 and specificity of 0.60 for identifying TSB levels of 205.2 μmol/L, and a sensitivity of 1.00 and specificity of 0.26 for identifying TSB levels of 342.0 μmol/L. The areas under the ROC curve (AUC) of JCard for identifying TSB levels of 153.9, 205.2, 256.5, and 342.0 μmol/L were 0.96, 0.92, 0.83, and 0.83, respectively. The AUC of TcB were 0.94, 0.91, 0.86, and 0.87, respectively. There were both no significant differences between the AUC of JCard and TcB in identifying TSB levels of 153.9 and 205.2 μmol/L (both P>0.05). However, the AUC of JCard were both lower than those of TcB in identifying TSB levels of 256.5 and 342.0 μmol/L (both P<0.05). Conclusions:JCard can be used to classify different levels of bilirubin, but its diagnostic efficacy decreases with increasing bilirubin levels. When TSB level are ≤205.2 μmol/L, its diagnostic efficacy is equivalent to that of the JH20-1B. To prevent the misdiagnosis of severe jaundice, it is recommended that parents use a low JCard score, such as 12, to identify severe hyperbilirubinemia (TSB ≥342.0 μmol/L).
2.Design and implementation of low-code platform for data services
Ren-Xin DING ; Tao ZHENG ; Mi-Ye WANG ; Qing-Ke SHI
Chinese Medical Equipment Journal 2024;45(4):13-19
Objective To design a low-code platform for data services to reduce the data interface service development costs and improve the development efficiency.Methods The platform was developed with Browser/Server(B/S)architecture,which used JAVA Spring Boot as its main framework and MySQL as the backend database system and had the functions for data source management,service catalog management,service management,service testing,service release management and service subscription management.Results The platform decreased the costs for interface development,operation and maintenance,lowered the technical threshold of interface development,unified the interface standard and enhanced hospital data security.Conclusion The platform developed provides support for hospital data interface service,digitalization and data services.[Chinese Medical Equipment Journal,2024,45(4):13-19]
3.Construction and application of big data sharing platform for clinical scientific research
You-Qiong CHEN ; Qing-Ke SHI ; Mi-Ye WANG ; Ren-Xin DING ; Xue-Jun ZHUO
Chinese Medical Equipment Journal 2024;45(4):27-31
Objective To construct a big data sharing platform for clinical scientific research to solve the problems of clinical research in decentralized application systems and data sharing safety.Methods A clinical research information data usage management system was developed through the formulation of management methods in line with the actual situation of the institution,normalized standard data usage processes and a data usage service team.Then a clinical scientific research big data sharing platform including the components for sharing environment construction,research application integration,data desensitization and encryption and file management was established based on the existing hospital systems,the requirements of clinical research data usage management and the habits of clinical researchers.Results The platform realized the balance between open sharing of clinical research data and data security control,which improved the efficiency of clinical researchers while reducing data security risks during data transmission and data analysis.Conclusion The clinical scientific research big data sharing platform meets the needs of clinical scientific research application and data security management,and provides references for the co-construction-sharing of medical big data resources.[Chinese Medical Equipment Journal,2024,45(4):27-31]
4.Elevated Levels of Naturally-Occurring Autoantibodies Against the Extracellular Domain of p75NTR Aggravate the Pathology of Alzheimer's Disease.
Chen-Yang HE ; Ding-Yuan TIAN ; Si-Han CHEN ; Wang-Sheng JIN ; Yuan CHENG ; Jia-Yan XIN ; Wei-Wei LI ; Gui-Hua ZENG ; Cheng-Rong TAN ; Jie-Ming JIAN ; Dong-Yu FAN ; Jun-Rong REN ; Yu-Hui LIU ; Yan-Jiang WANG ; Fan ZENG
Neuroscience Bulletin 2023;39(2):261-272
The extracellular domain (p75ECD) of p75 neurotrophin receptor (p75NTR) antagonizes Aβ neurotoxicity and promotes Aβ clearance in Alzheimer's disease (AD). The impaired shedding of p75ECD is a key pathological process in AD, but its regulatory mechanism is largely unknown. This study was designed to investigate the presence and alterations of naturally-occurring autoantibodies against p75ECD (p75ECD-NAbs) in AD patients and their effects on AD pathology. We found that the cerebrospinal fluid (CSF) level of p75ECD-NAbs was increased in AD, and negatively associated with the CSF levels of p75ECD. Transgenic AD mice actively immunized with p75ECD showed a lower level of p75ECD and more severe AD pathology in the brain, as well as worse cognitive functions than the control groups, which were immunized with Re-p75ECD (the reverse sequence of p75ECD) and phosphate-buffered saline, respectively. These findings demonstrate the impact of p75ECD-NAbs on p75NTR/p75ECD imbalance, providing a novel insight into the role of autoimmunity and p75NTR in AD.
Mice
;
Animals
;
Alzheimer Disease/pathology*
;
Receptor, Nerve Growth Factor
;
Amyloid beta-Peptides
;
Autoantibodies
;
Mice, Transgenic
5.Efficacy and safety of mitoxantrone hydrochloride liposome injection in treatment of peripheral T-cell lymphomas: a multicenter, non-interventional, ambispective cohort, real-world study (MOMENT)
Huiqiang HUANG ; Zhiming LI ; Lihong LIU ; Liang HUANG ; Jie JIN ; Hongyan TONG ; Hui ZHOU ; Zengjun LI ; Zhenqian HUANG ; Wenbin QIAN ; Kaiyang DING ; Quande LIN ; Ming HOU ; Yunhong HUANG ; Jingbo WANG ; Pengcheng HE ; Xiuhua SUN ; Xiaobo WANG ; Zunmin ZHU ; Yao LIU ; Jinhai REN ; Huijing WU ; Liling ZHANG ; Hao ZHANG ; Liangquan GENG ; Jian GE ; Ou BAI ; Liping SU ; Guangxun GAO ; Xin LI ; Yanli YANG ; Yijian CHEN ; Aichun LIU ; Xin WANG ; Yi WANG ; Liqun ZOU ; Xiaobing HUANG ; Dongping HUANG ; Shujuan WEN ; Donglu ZHAO ; Jun MA
Journal of Leukemia & Lymphoma 2023;32(8):457-464
Objective:To evaluate the efficacy and safety of mitoxantrone hydrochloride liposome injection in the treatment of peripheral T-cell lymphoma (PTCL) in a real-world setting.Methods:This was a real-world ambispective cohort study (MOMENT study) (Chinese clinical trial registry number: ChiCTR2200062067). Clinical data were collected from 198 patients who received mitoxantrone hydrochloride liposome injection as monotherapy or combination therapy at 37 hospitals from January 2022 to January 2023, including 166 patients in the retrospective cohort and 32 patients in the prospective cohort; 10 patients in the treatment-na?ve group and 188 patients in the relapsed/refractory group. Clinical characteristics, efficacy and adverse events were summarized, and the overall survival (OS) and progression-free survival (PFS) were analyzed.Results:All 198 patients were treated with mitoxantrone hydrochloride liposome injection for a median of 3 cycles (range 1-7 cycles); 28 cases were treated with mitoxantrone hydrochloride liposome injection as monotherapy, and 170 cases were treated with the combination regimen. Among 188 relapsed/refractory patients, 45 cases (23.9%) were in complete remission (CR), 82 cases (43.6%) were in partial remission (PR), and 28 cases (14.9%) were in disease stabilization (SD), and 33 cases (17.6%) were in disease progression (PD), with an objective remission rate (ORR) of 67.6% (127/188). Among 10 treatment-na?ve patients, 4 cases (40.0%) were in CR, 5 cases (50.0%) were in PR, and 1 case (10.0%) was in PD, with an ORR of 90.0% (9/10). The median follow-up time was 2.9 months (95% CI 2.4-3.7 months), and the median PFS and OS of patients in relapsed/refractory and treatment-na?ve groups were not reached. In relapsed/refractory patients, the difference in ORR between patients with different number of treatment lines of mitoxantrone hydrochloride liposome injection [ORR of the second-line, the third-line and ≥the forth-line treatment was 74.4% (67/90), 73.9% (34/46) and 50.0% (26/52)] was statistically significant ( P = 0.008). Of the 198 PTCL patients, 182 cases (91.9%) experienced at least 1 time of treatment-related adverse events, and the incidence rate of ≥grade 3 adverse events was 66.7% (132/198), which was mainly characterized by hematologic adverse events. The ≥ grade 3 hematologic adverse events mainly included decreased lymphocyte count, decreased neutrophil count, decreased white blood cell count, and anemia; non-hematologic adverse events were mostly grade 1-2, mainly including pigmentation disorders and upper respiratory tract infection. Conclusions:The use of mitoxantrone hydrochloride liposome injection-containing regimen in the treatment of PTCL has definite efficacy and is well tolerated, and it is a new therapeutic option for PTCL patients.
6.Proteomic Analysis Revealed the Involvement of Autophagy in Rat Acute Lung Injuries Caused by Gas Explosion Based on a Data-Independent Acquisition Strategy.
Shan HONG ; Chun Jie DING ; Qiang ZHOU ; Yun Zhe SUN ; Miao ZHANG ; Ning LI ; Xin Wen DONG ; Yi GUAN ; Lin ZHANG ; Lin Qiang TIAN ; Jia CAO ; Wu YAO ; Wen Jie REN ; San Qiao YAO
Biomedical and Environmental Sciences 2023;36(2):206-212
Animals
;
Rats
;
Explosions
;
Proteomics
;
Autophagy
7.Recommendations for prescription review of commonly used anti-seizure medications in treatment of children with epilepsy
Qianqian QIN ; Qian DING ; Xiaoling LIU ; Heping CAI ; Zebin CHEN ; Lina HAO ; Liang HUANG ; Yuntao JIA ; Lingyan JIAN ; Zhong LI ; Hua LIANG ; Maochang LIU ; Qinghong LU ; Xiaolan MO ; Jing MIAO ; Yanli REN ; Huajun SUN ; Yanyan SUN ; Jing XU ; Meixing YAN ; Li YANG ; Shengnan ZHANG ; Shunguo ZHANG ; Xin ZHAO ; Jie DENG ; Fang FANG ; Li GAO ; Hong HAN ; Shaoping HUANG ; Li JIANG ; Baomin LI ; Jianmin LIANG ; Jianxiang LIAO ; Zhisheng LIU ; Rong LUO ; Jing PENG ; Dan SUN ; Hua WANG ; Ye WU ; Jian YANG ; Yuqin ZHANG ; Jianmin ZHONG ; Shuizhen ZHOU ; Liping ZOU ; Yuwu JIANG ; Xiaoling WANG
Chinese Journal of Applied Clinical Pediatrics 2023;38(10):740-748
Anti-seizure medications (ASMs) are the main therapy for epilepsy.There are many kinds of ASMs with complex mechanism of action, so it is difficult for pharmacists to examine prescriptions.This paper put forward some suggestions on the indications, dosage forms/routes of administration, appropriateness of usage and dosage, combined medication and drug interaction, long-term prescription review, individual differences in pathophysiology of children, and drug selection when complicated with common epilepsy, for the reference of doctors and pharmacists.
8.Diagnostic accuracy of muscle ultrasound and plasma monocyte chemoattractant protein-1 for ICU-acquired weakness in patients with sepsis
Mingyue DING ; Shengyong REN ; Xin DONG ; Xingwei WANG ; Xiafei ZHAO ; Bingyu QIN
Chinese Critical Care Medicine 2022;34(1):12-17
Objective:To explore the diagnostic accuracy of muscle ultrasound and plasma monocyte chemoattractant protein-1 (MCP-1) for ICU-acquired weakness (ICU-AW) in patients with sepsis.Methods:A prospective observational study was conducted. Patients with sepsis admitted to the intensive care unit (ICU) of Henan Provincial People's Hospital from April 2021 to October 2021 were enrolled. The demographic data were collected. The enrolled patients were evaluated with Medical Research Council (MRC) score every day until discharged from ICU. During this period, patients with total MRC score < 48 (for two consecutive times and a time interval of 24 hours) were divided into ICU-AW group, those with total MRC score ≥ 48 were served as non-ICU-AW group. On the 1st, 4th and 7th day following admission into ICU, ultrasound was used to measure the muscle linear thickness of the rectus femoris (RF-MLT), the cross sectional area of the rectus femoris (RF-CSA) and the muscle linear thickness of the vastus intermedius muscle (VI-MLT). And meanwhile, the plasmas samples of patients were collected to measure MCP-1 concentration by enzyme-linked immunosorbent assay (ELISA). The difference of each index was compared between the ICU-AW group and the non-ICU-AW group. The risk factors of ICU-AW in patients with sepsis were analyzed by binary Logistic regression. Besides, receiver operator characteristic curve (ROC curve) was plotted, the diagnostic value of ultrasound parameters and plasma MCP-1 level for ICU-AW in patients with sepsis was analyzed.Results:A total of 99 septic patients were enrolled, with 68 patients in the ICU-AW group and 31 patients in the non-ICU-AW group. Compared with the patients in the ICU-AW group, the patients in the non-ICU-AW group tended to be older, and had higher sequential organ failure assessment (SOFA) score, higher acute physiology and chronic health evaluation Ⅱ (APACHEⅡ) score, higher rates of septic shock, higher blood lactic acid and lower Glasgow coma score (GCS). Binary Logistic regression analysis showed that APACHEⅡ score and septic shock were the risk factors of ICU-AW for septic patients [odds ratio ( OR) and 95% confidence interval (95% CI) were 1.310 (1.138-1.509) and 0.232 (0.072-0.746), respectively, both P < 0.05]. The RF-MLT, RF-CSA and VI-MLT on the 1st, 4th and 7th ICU day was falling over time. Compared with the patients in the ICU-AW group, the patients in the non-ICU-AW group had smaller RF-MLT on the 7th day [cm: 0.32 (0.22, 0.47) vs. 0.45 (0.34, 0.63), P < 0.05] and higher 7-day RF-CSA atrophy rate [25.85% (10.37%, 34.28%) vs. 11.65% (2.28%, 22.41%), P < 0.05]. According to ROC curve analysis, 7-day RF-MLT had diagnostic value for ICU-AW of septic patients. Area under ROC curve (AUC) was 0.688 (95% CI was 0.526-0.849); when the cut-off value was 0.41 cm, the sensitivity and the specificity were 66.7% and 68.4%. The levels of plasma MCP-1 in the ICU-AW group were significantly higher than those in the non-ICU-AW group on the 1st, 4th and 7th day. ROC curve analysis showed that the plasma MCP-1 levels on the 1st, 4th and 7th day played a significant role to diagnose ICU-AW for septic patients, the AUC and 95% CI were 0.732 (0.629-0.836), 0.865 (0.777-0.953), 0.891 (0.795-0.986), respectively. When the cut-off values were 206.3, 410.9, 239.5 ng/L, the sensitivity was 87.1%, 64.0%, 82.4%, and the specificity was 54.4%, 96.1%, 86.2%, respectively. Conclusion:The muscle mass parameters on the 7th day of bedside ultrasound and plasma MCP-1 levels had certain diagnostic values for ICU-AW in patients with sepsis.
9.Study on knowledge, attitudes and practices of pulse oximetry among pediatric healthcare providers in China and their influencing factors
Fengxia XUE ; Yuejie ZHENG ; Adong SHEN ; Hanmin LIU ; Xing CHEN ; Lili ZHONG ; Guangmin NONG ; Xin SUN ; Gen LU ; Shenggang DING ; Yuanxun FANG ; Jiahua PAN ; Zhiying HAN ; Yun SUN ; Qiang CHEN ; Yi JIANG ; Xiaoping ZHU ; Suping TANG ; Xiufang WANG ; Changshan LIU ; Shaomin REN ; Zhimin CHEN ; Deyu ZHAO ; Yong YIN ; Rongfang ZHANG ; Ming LI ; Yunxiao SHANG ; Yaping MU ; Shuhua AN ; Yangzom YESHE ; Peiru XU ; Yan XING ; Baoping XU ; Jing ZHAO ; Shi CHEN ; Wei XIANG ; Lihong LI ; Enmei LIU ; Yuxin SONG ; Yonghong YANG ; Kunling SHEN
Chinese Journal of Applied Clinical Pediatrics 2022;37(23):1807-1812
Objective:To investigate the knowledge, attitudes, and practices (KAP) of pulse oximetry among pediatric healthcare providers in China and analyze the factor influencing the KAP.Methods:A self-developed questionnaire was used for an online research on the KAP of 11 849 pediatric healthcare providers from 31 provinces, autonomous regions, and municipalities of China from March 11 to 14, 2022.The factors influencing the KAP of pulse oximetry among pediatric healthcare providers were examined by Logistic regression. Results:The scores of KAP, of pulse oximetry were 5.57±0.96, 11.24±1.25 and 11.19±4.54, respectively.The corresponding scoring rates were 69.61%, 74.95%, and 55.99%, respectively. Logistic regression results showed that the gender and working years of pediatric healthcare providers, the region they were located, and whether their medical institution was equipped with pulse oximeters were the main factors affecting the knowledge score (all P<0.05). Main factors influencing the attitude score of pediatric healthcare providers included their knowledge score, gender, educational background, working years, region, medical institution level, and whether the medical institution was equipped with pulse oximeters (all P<0.05). For the practice score, the main influencing factors were the knowledge score, gender, age, and whether the medi-cal institution was equipped with pulse oximeters (all P<0.05). Conclusions:Chinese pediatric healthcare providers need to further improve their knowledge about and attitudes towards pulse oximetry.Pulse oximeters are evidently under-used.It is urgent to formulate policies or guidelines, strengthen education and training, improve knowledge and attitudes, equip more institutions with pulse oximeters, and popularize their application in medical institutions.
10.Status of HVPG clinical application in China in 2021
Wen ZHANG ; Fuquan LIU ; Linpeng ZHANG ; Huiguo DING ; Yuzheng ZHUGE ; Jitao WANG ; Lei LI ; Guangchuan WANG ; Hao WU ; Hui LI ; Guohong CAO ; Xuefeng LU ; Derun KONG ; Lin SUN ; Wei WU ; Junhui SUN ; Jiangtao LIU ; He ZHU ; Dongliang LI ; Wuhua GUO ; Hui XUE ; Yu WANG ; Jiancuo GENGZANG ; Tian ZHAO ; Min YUAN ; Shirong LIU ; Hui HUAN ; Meng NIU ; Xin LI ; Jun MA ; Qingliang ZHU ; Wenbo GUO ; Kunpeng ZHANG ; Xiaoliang ZHU ; Birun HUANG ; Jianan LI ; Weidong WANG ; Hongfeng YI ; Qi ZHANG ; Long GAO ; Guo ZHANG ; Zhongwei ZHAO ; Kai XIONG ; Zexin WANG ; Hong SHAN ; Mingsheng LI ; Xueqiang ZHANG ; Haibin SHI ; Xiaogang HU ; Kangshun ZHU ; Zhanguo ZHANG ; Hong JIANG ; Jianbo ZHAO ; Mingsheng HUANG ; Wenyong SHEN ; Lin ZHANG ; Feng XIE ; Zhiwei LI ; Changlong HOU ; Shengjuan HU ; Jianwei LU ; Xudong CUI ; Ting LU ; Shaoqi YANG ; Wei LIU ; Junping SHI ; Yanming LEI ; Jinlun BAO ; Tao WANG ; Weixin REN ; Xiaoli ZHU ; Yong WANG ; Lei YU ; Qiang YU ; Huiling XIANG ; Wenqiang LUO ; Xiaolong QI
Chinese Journal of Hepatology 2022;30(6):637-643
Objective:The investigation and research on the application status of Hepatic Venous Pressure Gradient (HVPG) is very important to understand the real situation and future development of this technology in China.Methods:This study comprehensively investigated the basic situation of HVPG technology in China, including hospital distribution, hospital level, annual number of cases, catheters used, average cost, indications and existing problems.Results:According to the survey, there were 70 hospitals in China carrying out HVPG technology in 2021, distributed in 28 provinces (autonomous regions and municipalities directly under the central Government). A total of 4 398 cases of HVPG were performed in all the surveyed hospitals in 2021, of which 2 291 cases (52.1%) were tested by HVPG alone. The average cost of HVPG detection was (5 617.2±2 079.4) yuan. 96.3% of the teams completed HVPG detection with balloon method, and most of the teams used thrombectomy balloon catheter (80.3%).Conclusion:Through this investigation, the status of domestic clinical application of HVPG has been clarified, and it has been confirmed that many domestic medical institutions have mastered this technology, but it still needs to continue to promote and popularize HVPG technology in the future.

Result Analysis
Print
Save
E-mail