1.Comparison of the efficacy of unilateral nailing combined with bone cement reinforcement and bilateral nailing in the treatment of osteoporotic thoracolumbar fractures.
Yu-Liang LOU ; Guo-Ying CHEN ; Can-Feng WANG ; Hui FEI ; Guan-Rong SUN ; Ren-Fu QUAN ; Wei LI ; Feng HONG
China Journal of Orthopaedics and Traumatology 2025;38(2):134-149
OBJECTIVE:
To compare the efficacy of percutaneous pedicle screw combined with unilateral nail placement combined with bone cement strengthening and bilateral nail placement in the treatment of osteoporotic thoracic and lumbar fractures.
METHODS:
A retrospective case-control study was used to analyze the clinical data of 78 patients with osteoporotic thoracic and lumbar fractures admitted from October 2017 to May 2019. According to the surgical method, it was divided into percutaneous pedicle screw combined with unilateral nail placement combined with unilateral bone cement strengthening group(bone cement group) and percutaneous pedicle screw combined with bilateral nail placement(screw group). In the bone cement group, 40 patients included 16 males and 24 females, with a mean age of (62.1±8.1) years old. In the screw group, 38 patients included 18 males and 20 females with a mean age of (65.1±9.3) years old. The operation time, intraoperative blood loss, length of hospital stay and postoperative complications were compared between two groups. The kyphosis Cobb angle, anterior edge height ratio, central height ratio and pain visual analogue score(VAS) were compared.
RESULTS:
All patients were followed up for 25 to 36 months. The operation time (70.1±17.3) min of the cement group was shorter than that of the screw group (78.6±18.2) min(P<0.05). There were no significant differences in intraoperative blood loss and length of hospital stay(P>0.05). The VAS in the cement group 1 year 1.5±0.5 and the latest follow-up 0.5±0.3 after operation were lower than 1 year 1.8±0.3 and the latest follow-up 0.8±0.4 in the screw group(P<0.05). The kyphosis Cobb angle, anterior edge height ratio, central height ratio in bone cement group, 1 year (6.2±1.2)°, (86.6±3.5)%, (91.1±2.5)%, the last follow-up (6.4±0.7)°, (85.5±3.3)%, (90.5±6.3)% were better than that of the screw group 1 year (6.8±1.4)°, (83.1±2.4)%, (89.9±3.4)% and the latest follow-up (7.1±1.1)°, (82.6±4.1)%, (87.6±5.9)%(P<0.05). There were 3 cases of bone cement leakage in the cement group, all of which had no clinical symptoms;and 2 cases of pedicle screws were extracted in the screw group, and the screws were removed at the last follow-up.
CONCLUSION
Percutaneous pedicle screw combined with unilateral nail placement combined with bone cement strengthening and bilateral nail placement in the treatment of osteoporotic thoracic and lumbar compression fractures in the elderly can achieve satisfactory efficacy and effectively relieve the pain of patients, but the former internal fixation system is more stable, and the long-term follow-up can effectively maintain the height of the anterior middle column and the correction of kyphosis deformity, and the incidence of chronic low back pain is lower.
Humans
;
Male
;
Female
;
Aged
;
Bone Cements
;
Middle Aged
;
Thoracic Vertebrae/surgery*
;
Lumbar Vertebrae/surgery*
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Osteoporotic Fractures/surgery*
;
Case-Control Studies
;
Bone Nails
;
Pedicle Screws
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Epidemiological characteristics and spatiotemporal clustering analysis of leptospirosis in Zhejiang Province from 2018 to 2022
Song GUO ; Wen-Wu YAO ; Ying LIU ; Xu-Guang SHI ; Jiang-Ping REN ; Rong ZHANG ; Zhang-Nü YANG ; Ji-Min SUN
Chinese Journal of Zoonoses 2024;40(9):855-859
The epidemiological and spatiotemporal distribution characteristics of human leptospirosis in Zhejiang Province from 2018 to 2022 were analyzed,to provide a scientific basis for formulating leptospirosis prevention and control strategies.Data on leptospirosis were collected from the China Information System for Disease Control and Prevention,and analyzed with descriptive epidemiological methods.ArcMap 10.8 software was used for spatial autocorrelation analysis and visual display of the results.SaTScan 10.1.2 software was used for spatiotemporal scanning,to analyze and describe the spatiotemporal aggrega-tion characteristics of leptospirosis.A total of 255 human cases of leptospirosis were reported in Zhejiang Province from 2018 to 2022,including one death;the average annual incidence was 0.084 3/100 000,and the average annual mortality was 0.000 3/100 000.The highest incidence of leptospirosis in Zhejiang occurred from August to October.Most cases were in middle-aged and older people 45-86 years of age(221 cases,86.67%).The number of cases was highest among people 65-69 years of age(57 cases).The male to female ratio was 4.67∶1.The main occupation was farming(190 cases,74.51%).The cumulative number of cases in Wenzhou and Lishui in 3 years(201 cases)accounted for 78.82%of the total cases.The global spatial auto-correlation analysis from 2018 to 2022 showed that the incidence of leptospirosis in the province presented a positive spatial au-tocorrelation.Local spatial autocorrelation analysis indicated that the"high-high"gathering areas were concentrated primarily in Wenzhou,Lishui,and Taizhou in the mountainous and hilly areas of southern Zhejiang Province.Spatiotemporal scanning anal-ysis revealed three clusters with high incidence in southern Zhejiang Province.The incidence of leptospirosis in Zhejiang Prov-ince showed clear regional clustering and seasonality,and the high incidence area was mainly in the mountainous and hilly areas of southern Zhejiang Province.The cases occurred mainly in middle-aged and older male farmers.Health education among rural resi-dents should be strengthened to prevent potential epidemic risks.
6.Metagenomic next-generation sequencing for the diagnosis of Pneumocystis jirovecii pneumonia after allogeneic hematopoietic stem cell transplantation
Rong FU ; Ren LIN ; Zhiping FAN ; Fen HUANG ; Na XU ; Li XUAN ; Yifei HUANG ; Hui LIU ; Ke ZHAO ; Zhixiang WANG ; Ling JIANG ; Min DAI ; Jing SUN ; Qifa LIU
Chinese Journal of Hematology 2024;45(1):62-67
Objectives:To investigate the value of metagenomic next-generation sequencing (mNGS) in the diagnosis of Pneumocystis jirovecii pneumonia (PJP) in patients undergoing allogeneic hematopoietic stem cell transplantation (allo-HSCT) .Methods:The data of 98 patients with suspected pulmonary infection after allo-HSCT who underwent pathogen detection from bronchoalveolar lavage fluid between June 2016 and August 2023 at Nanfang Hospital were analyzed. The diagnostic performance of mNGS, conventional methods, and real-time quantitative polymerase chain reaction (qPCR) for PJP were compared.Results:A total of 12 patients were diagnosed with PJP, including 11 with a proven diagnosis and 1 with a probable diagnosis. Among the patients with a proven diagnosis, 1 was positive by both conventional methods and qPCR, and 10 were positive by qPCR only. Pneumocystis jirovecii was detected by mNGS in all 12 patients. The diagnostic sensitivity of mNGS for PJP was 100%, which was greater than that of conventional methods (8.3%, P=0.001) and similar to that of qPCR (91.6%, P=1.000) . A total of 75% of the patients developed mixed pulmonary infections, and cytomegalovirus and Epstein-Barr virus were the most common pathogens. Mixed infection was detected in eight patients by mNGS and in five patients by qPCR, but not by conventional methods ( P=0.008) . Conclusions:mNGS had good sensitivity for diagnosing PJP after allo-HSCT and was advantageous for detecting mixed infectious pathogens; therefore, mNGS might be an effective supplement to regular detection methods and qPCR.
7.Different methods in predicting mortality of pediatric intensive care units sepsis in Southwest China
Rong LIU ; Zhicai YU ; Changxue XIAO ; Shufang XIAO ; Juan HE ; Yan SHI ; Yuanyuan HUA ; Jimin ZHOU ; Guoying ZHANG ; Tao WANG ; Jianyu JIANG ; Daoxue XIONG ; Yan CHEN ; Hongbo XU ; Hong YUN ; Hui SUN ; Tingting PAN ; Rui WANG ; Shuangmei ZHU ; Dong HUANG ; Yujiang LIU ; Yuhang HU ; Xinrui REN ; Mingfang SHI ; Sizun SONG ; Jumei LUO ; Juan LIU ; Juan ZHANG ; Feng XU
Chinese Journal of Pediatrics 2024;62(3):204-210
Objective:To investigate the value of systemic inflammatory response syndrome (SIRS), pediatric sequential organ failure assessment (pSOFA) and pediatric critical illness score (PCIS) in predicting mortality of pediatric sepsis in pediatric intensive care units (PICU) from Southwest China.Methods:This was a prospective multicenter observational study. A total of 447 children with sepsis admitted to 12 PICU in Southwest China from April 2022 to March 2023 were enrolled. Based on the prognosis, the patients were divided into survival group and non-survival group. The physiological parameters of SIRS, pSOFA and PCIS were recorded and scored within 24 h after PICU admission. The general clinical data and some laboratory results were recorded. The area under the curve (AUC) of the receiver operating characteristic curve was used to compare the predictive value of SIRS, pSOFA and PCIS in mortality of pediatric sepsis.Results:Amongst 447 children with sepsis, 260 patients were male and 187 patients were female, aged 2.5 (0.8, 7.0) years, 405 patients were in the survival group and 42 patients were in the non-survival group. 418 patients (93.5%) met the criteria of SIRS, and 440 patients (98.4%) met the criteria of pSOFA≥2. There was no significant difference in the number of items meeting the SIRS criteria between the survival group and the non-survival group (3(2, 4) vs. 3(3, 4) points, Z=1.30, P=0.192). The pSOFA score of the non-survival group was significantly higher than that of the survival group (9(6, 12) vs. 4(3, 7) points, Z=6.56, P<0.001), and the PCIS score was significantly lower than that of the survival group (72(68, 81) vs. 82(76, 88) points, Z=5.90, P<0.001). The predictive value of pSOFA (AUC=0.82) and PCIS (AUC=0.78) for sepsis mortality was significantly higher than that of SIRS (AUC=0.56) ( Z=6.59, 4.23, both P<0.001). There was no significant difference between pSOFA and PCIS ( Z=1.35, P=0.176). Platelet count, procalcitonin, lactic acid, albumin, creatinine, total bilirubin, activated partial thromboplastin time, prothrombin time and international normalized ratio were all able to predict mortality of sepsis to a certain degree (AUC=0.64, 0.68, 0.80, 0.64, 0.68, 0.60, 0.77, 0.75, 0.76, all P<0.05). Conclusion:Compared with SIRS, both pSOFA and PCIS had better predictive value in the mortality of pediatric sepsis in PICU.
8.Clinical characterization and prediction modeling of lung cancer patients with high energy metabolism
Jiang-Shan REN ; Jun-Mei JIA ; Ping SUN ; Mei PING ; Qiong-Qiong ZHANG ; Yan-Yan LIU ; He-Ping ZHAO ; Yan CHEN ; Dong-Wen RONG ; Kang WANG ; Hai-Le QIU ; Chen-An LIU ; Yu-Yu FAN ; De-Gang YU
Medical Journal of Chinese People's Liberation Army 2024;49(9):1004-1010
Objective To analyze the clinical characteristics of high energy metabolism in lung cancer patients and its correlation with body composition,nutritional status,and quality of life,and to develop a corresponding risk prediction model.Methods Retrospectively analyzed 132 primary lung cancer patients admitted to the First Hospital of Shanxi Medical University from January 2022 to May 2023,and categorized into high(n=94)and low energy metabolism group(n=38)based on their metabolic status.Differences in clinical data,body composition,Patient Generated Subjective Global Assessment(PG-SGA)scores,and European Organization for Research and treatment of Cancer(EORTC)Quality of Life Questionnaire-Core 30(QLQ-C30)scores were compared between the two groups.Logistic regression was used to identify the risk factors for high energy metabolism in lung cancer patients,and a risk prediction model was established accordingly;the Hosmer-Lemeshow test was used to assess the model fit,and the ROC curve was used to test the predictive efficacy of the model.Results Of the 132 patients with primary lung cancer,94(71.2%)exhibited high energy metabolism.Compared with low energy metabolism group,patients in high-energy metabolism group had a smoking index of 400 or higher,advanced disease staging of stage Ⅲ or Ⅳ,and higher levels of IL-6 level,low adiposity index,low skeletal muscle index,and malnutrition(P<0.05),and lower levels of total protein,albumin,hemoglobin level,and prognostic nutritional index(PNI)(P<0.05).There was no significant difference in age,gender,height,weight,BMI and disease type between the two groups(P>0.05).Logistic regression analysis showed that smoking index≥400,advanced disease stage,IL-6≥3.775 ng/L,and PNI<46.43 were independent risk factors for high energy metabolism in lung cancer patients.The AUC of the ROC curve for the established prediction model of high energy metabolism in lung cancer patients was 0.834(95%CI 0.763-0.904).Conclusion The high energy metabolic risk prediction model of lung cancer patients established in this study has good fit and prediction efficiency.
9.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
10.Analysis of individual monitoring results of occupational external exposure in a steel enterprise in Baotou city from 2018 to 2022
Jing WANG ; Shuchao SUN ; Xuran REN ; Xiaogang LU ; Jie ZHANG ; Shiyu PANG ; Rong JIN
Chinese Journal of Radiological Medicine and Protection 2024;44(8):675-680
Objective:To study the levels of individual dose of radiation workers in a steel enterprise in Baotou City from 2018 to 2022, and analyze the main factors affecting the annual dose, and provide basic data for revising relevant standards.Methods:According to the requirements of occupational external exposure personal monitoring standards (GBZ 128-2019), the personal dose monitoring of workers working in a steel enterprise in Baotou City from 2018 to 2022 was carried out, three months for a period, continuous monitoring 4 periods, and the results were analyzed.Results:A total of 1 360 workers from 10 employers within the enterprise were surveyed. The annual doses were in the range of 0.500 - 0.844 mSv, with an average annual individual dose of 0.676 mSv. Especially, the average annual individulal effective dose to workers for safety management and inspection was 0.986 mSv, hiher than 0.698 mSv to rolling workers, pump operators, and continuous casters ( Z = 56.89, P < 0.001). Additionally, female worders working with the radiation generators had a higher average annual individual effective dose of 0.821 mSv, than 0.691 mSv to the male workers who were exposed to sealed sources possibly in many cases as needed, with a statistically significant difference ( Z =-5.53, P < 0.001). Conclusions:The average annual individual effective dose to radiation workers in an iron and steel enterprise in Baotou City meets the requirements of the relevent national standard. The annual dose of women and some workers is relatively high, so the management of radiation workers should be strengthened and the radiation protection measures in the workplace should be improved.

Result Analysis
Print
Save
E-mail