1.Dizziness in Patients With Obstructive Sleep Apnea
Jae Rim KIM ; Soo Ryun PARK ; Hea Ree PARK ; Eun Yeon JOO
Journal of Sleep Medicine 2022;19(2):39-45
Obstructive sleep apnea (OSA) and dizziness are common conditions observed in the general population, and several epidemiological studies have reported an association between OSA and dizziness. Vestibular dysfunction, autonomic instability, and cerebellar degeneration secondary to recurrent hypoxia are implicated as mechanisms underlying dizziness in patients with OSA. Moreover, OSA is a risk factor for many diseases associated with dizziness, including Meniere disease, stroke, and psychiatric conditions. A dizziness questionnaire, vestibular function tests, and tests for autonomic function are useful for evaluation of OSA and concomitant dizziness. A growing body of evidence has shown that effective treatment of OSA including continuous positive airway pressure therapy reduces dizziness in these patients. Greater attention to dizziness is warranted in patients with OSA.
2.A Sensitive and Specific Liquid ChromatographyTandem Mass Spectrometry Assay for Simultaneous Quantification of Salivary Melatonin and Cortisol:Development and Comparison With Immunoassays
Sunghwan SHIN ; Hyeonju OH ; Hea Ree PARK ; Eun Yeon JOO ; Soo-Youn LEE
Annals of Laboratory Medicine 2021;41(1):108-113
Melatonin and cortisol are clinically important for diagnosing sleep and mood disorders.We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/ MS) assay for simultaneous measurement of salivary melatonin and cortisol concentrations according to the Clinical and Laboratory Standards Institute guidelines. Additionally, we compared the LC-MS/MS assay with immunoassays, ELISA (Direct Salivary Melatonin Elisa EK-DSM, Bühlmann Laboratories AG, Schönenbuch, Switzerland) and electrochemiluminescence immunoassay (Cortisol II, Roche, Mannheim, Germany), using 121 saliva samples. The LC-MS/MS assay exhibited good performance in terms of linearity, precision, accuracy, limit of detection, lower limit of quantification, extraction recovery, carry-over, and matrix effect. The LC-MS/MS assay and immunoassays showed strong correlation (Pearson’s r = 0.910 for melatonin, r = 0.955 for cortisol), but demonstrated a significant mean bias of 23.2% (range 54.0–143.7%) for melatonin and 48.9% (range 59.7–184.7%) for cortisol. Our LC-MS/MS assay provided more sensitive and reliable salivary melatonin and cortisol quantification results compared with immunoassays.
3.Effects of Organic Light-Emitting Diodes on Circadian Rhythm and Sleep
Hyunjin JO ; Hea Ree PARK ; Su Jung CHOI ; Soo-Youn LEE ; Seog Ju KIM ; Eun Yeon JOO
Psychiatry Investigation 2021;18(5):471-477
Objective:
Organic light-emitting diodes (OLEDs) emit less blue light than traditional light-emitting diodes (LEDs), and we previously found that early-night OLED light exposure (LE) delays the melatonin phase by less than LED at a color temperature of 4,000 K. As a follow-up study, we investigated the effects of OLED and LED at a different color temperature (3,000 K) on melatonin profile, sleep, and vigilance.
Methods:
24 healthy subjects (27.5±5.1 years) were exposed to three light conditions [OLED, LED, and dim light (DL)] from 17:30 to 24:00, in a random order and with a 1-week interval. Saliva samples for melatonin were taken every hour from 18:00 to 24:00. Polysomnography (PSG) and a psychomotor vigilance test (PVT) were performed.
Results:
Melatonin onset time was significantly delayed under OLED and LED compared with DL, with no significant difference between OLED and LED. The mean melatonin level at 24:00 under LED was lower than that under DL, but there was no significant difference between OLED LE and DL. The percentage of slow wave sleep (N3) in LED was significantly lower than in OLED.
Conclusion
Exposure to light in the evening can suppress melatonin secretion late at night and disturb deep sleep, and those effects are slightly worse under LED than OLED.
4.Effects of Organic Light-Emitting Diodes on Circadian Rhythm and Sleep
Hyunjin JO ; Hea Ree PARK ; Su Jung CHOI ; Soo-Youn LEE ; Seog Ju KIM ; Eun Yeon JOO
Psychiatry Investigation 2021;18(5):471-477
Objective:
Organic light-emitting diodes (OLEDs) emit less blue light than traditional light-emitting diodes (LEDs), and we previously found that early-night OLED light exposure (LE) delays the melatonin phase by less than LED at a color temperature of 4,000 K. As a follow-up study, we investigated the effects of OLED and LED at a different color temperature (3,000 K) on melatonin profile, sleep, and vigilance.
Methods:
24 healthy subjects (27.5±5.1 years) were exposed to three light conditions [OLED, LED, and dim light (DL)] from 17:30 to 24:00, in a random order and with a 1-week interval. Saliva samples for melatonin were taken every hour from 18:00 to 24:00. Polysomnography (PSG) and a psychomotor vigilance test (PVT) were performed.
Results:
Melatonin onset time was significantly delayed under OLED and LED compared with DL, with no significant difference between OLED and LED. The mean melatonin level at 24:00 under LED was lower than that under DL, but there was no significant difference between OLED LE and DL. The percentage of slow wave sleep (N3) in LED was significantly lower than in OLED.
Conclusion
Exposure to light in the evening can suppress melatonin secretion late at night and disturb deep sleep, and those effects are slightly worse under LED than OLED.
5.Effect of Sleep Quality on Headache-Related Impact in Primary Headache Disorders
Soohyun CHO ; Mi Ji LEE ; Hea Ree PARK ; Seonwoo KIM ; Eun Yeon JOO ; Chin-Sang CHUNG
Journal of Clinical Neurology 2020;16(2):237-244
Background:
and PurposeSleep disturbance is common in patients with primary headache disorders. We were interest in whether poor sleep quality affects patients directly or via increases in the frequency and severity of headaches. To that end, we investigated the direct and indirect effects of sleep quality on the headache-related impact among patients with primary headache disorders.
Methods:
We analyzed migraine and tension-type headache (TTH) in patients included in the headache registry of our headache clinic from October 2015 to May 2018. We collected information on the headache frequency, severity, and psychological status. Sleep quality and headache-related impact were measured using the Pittsburgh Sleep Quality Index and Headache Impact Test-6, respectively. We performed path analyses with headache frequency and severity as covariates to determine the direct effect of sleep quality on the headache-related impact, and the indirect effects mediated by increases in the headache frequency and severity.
Results:
This study included 915 patients: 784 with migraine and 131 with TTH. Worse sleep quality was independently associated with greater headache-related impact in both patients with migraine and those with TTH. Path analysis revealed a direct effect (β=0.207,p<0.001) of sleep quality and an indirect effect mediated by headache frequency and severity (β=0.067, p=0.004) on the headache-related impact in migraine. In TTH, only direct effects of sleep quality on the headache-related impact were significant (β=0.224, p=0.004).
Conclusions
We suggest that poor sleep quality can directly increase the headache-related impact in both patients with migraine and TTH as well as indirectly by increasing the headache frequency and severity in patients with migraine.
6.Effects of Evening Exposure to Light from Organic Light-Emitting Diodes on Melatonin and Sleep
Hea Ree PARK ; Su Jung CHOI ; Hyunjin JO ; Jae Wook CHO ; Eun Yeon JOO
Journal of Clinical Neurology 2020;16(3):401-407
Background:
and Purpose: Organic light-emitting diodes (OLEDs) emit less blue light than traditional light-emitting diodes (LEDs), but the effects of OLED light exposure (LE) on melatonin and sleep have not been evaluated.
Methods:
Twenty-four healthy subjects (age 26.9±5.7 years; including 18 females) with the intermediate chronotype were exposed to three different light conditions [4,000 K 150 lux OLED LE, 4,000 K 150 lux LED LE, and dim light (DL) at <10 lux] for 6.5 h from 17:30 to 24:00, in a random order and with a 1-week interval. Participants entered the unit for the experiment at 16:00, and their daylight was measured by actigraphy from 8:00 to 16:00 during each session. Saliva samples for melatonin were taken every hour from 18:00 to 24:00. Sleep was monitored by polysomnography, and vigilance was evaluated by psychomotor vigilance test upon awakening.
Results:
Melatonin onset occurred at 21:11±01:24, 21:20±01:19, and 21:36±01:16 in the DL, OLED, and LED conditions, respectively. Melatonin onset was significantly delayed under LED LE compared to DL (p=0.007) but did not differ under OLED LE (p=0.245). Melatonin suppression, sleep parameters, and vigilance were similar among the three light conditions. The accumulated amount of daytime light in each session was negatively correlated with the melatonin onset time under the DL (rho=-0.634, p=0.002) and OLED (rho=-0.447, p=0.029) conditions, not under the LED condition (p=0.129).
Conclusions
Melatonin onset under OLED LE was not significantly delayed compared to DL.Exposure to sufficient daylight may advance melatonin onset even when a subject is exposed to OLED LE in the evening.
7.Genitopatellar Syndrome Secondary to De Novo KAT6B Mutation: The First Genetically Confirmed Case in South Korea
Byuh Ree KIM ; Jeong Ho HAN ; Jeong Eun SHIN ; Min Soo PARK ; Kook In PARK ; Ran NAMGUNG ; Hyun Joo LEE ; Jin Sung LEE ; Ho Sun EUN
Yonsei Medical Journal 2019;60(4):395-398
Genitopatellar syndrome (GPS) is a rare disorder characterized by patellar hypoplasia, flexion contractures of the lower limbs, psychomotor retardation and genital and renal anomalies. We report the case of a female infant diagnosed with GPS to a KAT6B gene mutation, which was identified using whole exome sequencing.
Contracture
;
Exome
;
Female
;
Humans
;
Infant
;
Korea
;
Lower Extremity
8.Serotype Distribution and Antimicrobial Resistance of Invasive and Noninvasive Streptococcus pneumoniae Isolates in Korea between 2014 and 2016
Dong Chul PARK ; Si Hyun KIM ; Dongeun YONG ; In Bum SUH ; Young Ree KIM ; Jongyoun YI ; Wonkeun SONG ; Sae Am SONG ; Hee Won MOON ; Hae Kyung LEE ; Kyoung Un PARK ; Sunjoo KIM ; Seok Hoon JEONG ; Jaehyeon LEE ; Joseph JEONG ; Yu Kyung KIM ; Miae LEE ; Jihyun CHO ; Jong Wan KIM ; Kyeong Seob SHIN ; Sang Hyun HWANG ; Jae Woo CHUNG ; Hye In WOO ; Chae Hoon LEE ; Namhee RYOO ; Chulhun L CHANG ; Hyun Soo KIM ; Jayoung KIM ; Jong Hee SHIN ; Soo Hyun KIM ; Mi Kyung LEE ; Seong Gyu LEE ; Sook Jin JANG ; Kyutaeg LEE ; HunSuk SUH ; Yong Hak SOHN ; Min Jung KWON ; Hee Joo LEE ; Ki Ho HONG ; Kwang Sook WOO ; Chul Min PARK ; Jeong Hwan SHIN
Annals of Laboratory Medicine 2019;39(6):537-544
BACKGROUND: Several factors contribute to differences in Streptococcus pneumoniae serotype distribution. We investigated the serotype distribution and antimicrobial resistance of S. pneumoniae isolated between 2014 and 2016 in Korea. METHODS: We collected a total of 1,855 S. pneumoniae isolates from 44 hospitals between May 2014 and May 2016, and analyzed the serotypes by sequential multiplex PCR. We investigated the distribution of each serotype by patient age, source of the clinical specimen, and antimicrobial resistance pattern. RESULTS: The most common serotypes were 11A (10.1%), followed by 19A (8.8%), 3 (8.5%), 34 (8.1%), 23A (7.3%), and 35B (6.2%). The major invasive serotypes were 3 (12.6%), 19A (7.8%), 34 (7.8%), 10A (6.8%), and 11A (6.8%). Serotypes 10A, 15B, 19A, and 12F were more common in patients ≤5 years old, while serotype 3 was more common in patients ≥65 years old compared with the other age groups. The coverage rates of pneumococcal conjugate vaccine (PCV)7, PCV10, PCV13, and pneumococcal polysaccharide vaccine 23 were 11.8%, 12.12%, 33.3%, and 53.6%, respectively. Of the 1,855 isolates, 857 (46.2%) were multi-drug resistant (MDR), with serotypes 11A and 19A predominant among the MDR strains. The resistance rates against penicillin, cefotaxime, and levofloxacin were 22.8%, 12.5%, and 9.4%, respectively. CONCLUSIONS: There were significant changes in the major S. pneumoniae serotypes in the community. Non-PCV13 serotypes increased in patients ≤5 years old following the introduction of national immunization programs with the 10- and 13-polyvalent vaccines.
Cefotaxime
;
Humans
;
Immunization Programs
;
Korea
;
Levofloxacin
;
Multiplex Polymerase Chain Reaction
;
Penicillins
;
Pneumococcal Vaccines
;
Pneumonia
;
Serogroup
;
Streptococcus pneumoniae
;
Streptococcus
;
Vaccines
9.Effects of Light on Daytime Sleep in 12 Hours Night Shift Workers: A Field Study
Su Jung CHOI ; Hea Ree PARK ; Eun Yeon JOO
Journal of Sleep Medicine 2019;16(1):26-35
OBJECTIVES: Night shift workers suffer from sleep and daytime disturbances due to circadian misalignment. To investigate the role of environmental light in daytime sleep following 12 h-night shift work. METHODS: We enrolled 12 h-shift female nurses working at one university-affiliated hospital (n=10, mean age 26.6 years, shift work duration 3.8 years). This is a cross-over study to compare sleep between under light exposure (30 lux) and in the dark (<5 lux) following 12 h-night duty. Two sessions of experiments were underwent and the interval between sessions was about a month. Psychomotor vigilance test (PVT) had performed on awakening from sleep at each session and sleep-wake pattern had been monitored by actigraphy throughout the study period. Daytime sleep was also compared with night sleep of age-and gender matched daytime workers (n=10). RESULTS: Sleep parameters and PVT scores were not different between two light conditions. Activities during sleep seemed to be more abundant under 30 lux condition than in the dark, which was not significant. Compared to night sleep, daytime sleep of shift workers was different in terms of rapid eye movement (REM) sleep. Three shift workers showed sleep onset REM sleep and first REM sleep period was the longest during daytime sleep. CONCLUSIONS: Unexpectedly, daytime sleep of 12 h night shift workers was well-maintained regardless of light exposure. Early occurrence of REM sleep and shorter sleep latency during daytime sleep suggest that shift workers meet with misalignment of circadian rhythm as well as increased homeostatic sleep pressure drive.
Actigraphy
;
Circadian Rhythm
;
Cross-Over Studies
;
Female
;
Humans
;
Polysomnography
;
Sleep, REM
10.Risk factors for persistent otitis media with effusion in children: a case-control study
Ju Yeon LEE ; Se Hyung KIM ; Chan Il SONG ; Young Ree KIM ; Yoon Joo KIM ; Jae Hong CHOI
Yeungnam University Journal of Medicine 2018;35(1):70-75
BACKGROUND: Otitis media with effusion (OME) is defined as middle ear effusion without acute signs of infection. OME usually resolves spontaneously; however, persistent OME may require the insertion of a ventilation tube. This study investigated risk factors for persistent OME in children who undergo ventilation tube insertion.METHODS: Children who were admitted to undergo ventilation tube insertion at Jeju National University Hospital between August 2015 and July 2016 were enrolled as the case group. Healthy children without persistent OME from August 2016 to July 2017 were enrolled as the control group. Baseline characteristics and predisposing factor data were collected using an interview questionnaire. Middle ear fluids were collected from the case group.RESULTS: A total of 31 patients underwent ventilation tube insertion. The mean age of the case group was 4.53 years, with a male-to-female ratio of 21:10. Twenty-nine (93.5%) children attended a daycare center, and 21 (67.7%) had experience with bottle feeding. Fifteen (48.4%) children in the case group and 3 (9.7%) in the control group first attended a daycare center at < 1 year of age (odds ratio=9.96; 95% confidence interval=2.44–39.70; p=0.001). No bacteria were found in middle ear fluid collected from the 31 operated children. Nasopharyngeal bacterial colonization was found in 13 (41.9%) and 17 (54.8%) children in the case and control groups, respectively.CONCLUSION: Earlier attendance at a daycare center was the only predisposing factor for ventilation tube insertion in our study. The aseptic nature of middle ear fluids found in children with OME highlights the efficacy of antimicrobial use.
Bacteria
;
Bottle Feeding
;
Case-Control Studies
;
Causality
;
Child
;
Colon
;
Ear, Middle
;
Humans
;
Middle Ear Ventilation
;
Otitis Media with Effusion
;
Otitis Media
;
Otitis
;
Risk Factors
;
Ventilation

Result Analysis
Print
Save
E-mail