1.Survival and toxicity outcomes with radiotherapy technique and timing in the management of Wilms tumor: A systematic review to inform a National Clinical Practice Guideline Development
Warren Bacorro ; Jane Efflyn Lardizabal-Bunyi ; Michelle Rodriguez ; Maria Cecilia Leongson-Cruz
Journal of Medicine University of Santo Tomas 2024;8(2):1429-1442
PURPOSE
Wilms tumor (WT) management has evolved into a multimodality paradigm that includes radiotherapy (RT), usually as an adjuvant or consolidative modality. Protocols are refined to maximize cure and compliance while minimizing acute toxicity and long-term effects. RT technique and timing are two factors that could improve these outcomes. We reviewed the evidence on survival and toxicity outcomes among WT patients with conventional versus advanced RT techniques and early versus delayed RT to inform a Department of Health (DOH) commissioned guideline.
MATERIALS AND METHODSWe systematically searched PubMed, EuropePMC, EBSCOHost, HERDIN, systematic review and clinical trial registries and official websites of scientific societies for relevant publications and grey literature. Eligibility screening, risk-of-bias assessment and data extraction were performed using a single-reviewer approach. Given the study and data heterogeneity, only a qualitative synthesis was performed. Certainty of evidence assessment was done using the GRADE approach.
RESULTSWe screened 314 studies and included seven in the review, including a phase 1/2 trial and six retrospective studies, all from first-world countries (US, France, Netherlands), except one from a newly industrialized country (Brazil). The certainty of evidence on the survival and toxicity outcomes with advanced RT techniques was very low. Moderate-certainty evidence supports that giving RT >14 days after surgery leads to increased mortality.
CONCLUSIONCurrent evidence does not support the routine use of advanced RT techniques; proper contextualization is necessary. Tertiary centers managing WT should strive to administer RT within 14 days after surgery whenever possible.
Wilms Tumor ; Nephroblastoma ; Radiotherapy ; Radiotherapy, Intensity-modulated ; Survival ; Toxicity
3.Application of PET-LINAC in Biology-guided Radiotherapy.
Xin YANG ; Wei ZHAO ; Xinzhi TIAN ; Jun CAI ; Siwei XIE ; Qi LIU ; Hao PENG ; Qiyu PENG
Chinese Journal of Medical Instrumentation 2023;47(3):237-241
Biology-guided radiotherapy (BgRT) is a novel technique of external beam radiotherapy, combining positron emission tomography-computed tomography (PET-CT) with a linear accelerator (LINAC). The key innovation is to utilize PET signals from tracers in tumor tissues for real-time tracking and guiding beamlets. Compared with a traditional LINAC system, a BgRT system is more complex in hardware design, software algorithm, system integration and clinical workflow. RefleXion Medical has developed the world's first BgRT system. Nevertheless, its actively advertised function, PET-guided radiotherapy, is still in the research and development phase. In this review study, we presented a number of issues related to BgRT, including its technical advantages and potential challenges.
Positron Emission Tomography Computed Tomography
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Algorithms
;
Particle Accelerators
;
Biology
;
Radiotherapy, Image-Guided/methods*
;
Radiotherapy Dosage
4.Development of Practical Proton Therapy System Based on Clinical Needs.
Chinese Journal of Medical Instrumentation 2023;47(4):355-359
In recent years, proton therapy technology has developed rapidly, and the number of patients treated with proton therapy has gradually increased. However, the application of proton therapy technology was far from practical needs. Because of the shortage of resources and the high cost, proton therapy systems are not accessible and affordable for most patients. In order to change this situation, it is necessary to develop a new truly practical proton therapy system based on clinical needs. Conceptual design of a practical proton therapy system was proposed. Compared with the existing system, one feature of the newly designed system is to reduce the maximum energy of the proton beam to 175~200 MeV; another feature is the configuration of deluxe and economical treatment rooms, the deluxe room is equipped with a rotating gantry and a six-dimensional treatment bed, and the economical room is equipped with a horizontal fixed beam and a patient vertical rotating setup device. This design can not only reduce the cost of proton therapy system and equipment room construction, but also facilitate the hospital to choose the appropriate configuration, which will ultimately benefit more patients.
Humans
;
Proton Therapy
;
Radiotherapy Planning, Computer-Assisted
;
Hospitals
;
Radiotherapy Dosage
5.Progress in Development of Dose Verification System Software KylinRay-Dose4D.
Huaqing ZHENG ; Guangyao SUN ; Yun ZHAO ; Bo XIAO ; Jing JIA ; Tao HE ; Pengcheng LONG ; Liqin HU
Chinese Journal of Medical Instrumentation 2023;47(4):360-364
Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.
Humans
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy, Intensity-Modulated/methods*
;
Software
;
Neoplasms
;
Phantoms, Imaging
;
Radiometry/methods*
6.Feasibility Study of Beam Angle Optimization Based on Scripts in Automated-planning for Liver Cancer.
Han XIAO ; Yujie ZHANG ; Weixing JI ; Tingting LI ; Jianying ZHANG
Chinese Journal of Medical Instrumentation 2023;47(4):365-369
OBJECTIVE:
To study the feasibility and potential benefits of beam angle optimization (BAO) to automated planning in liver cancer.
METHODS:
An approach of beam angle sampling is proposed to implement BAO along with the module Auto-planning in treatment planning system (TPS) Pinnacle. An in-house developed plan quality metric (PQM) is taken as the preferred evaluating method during the sampling. The process is driven automatically by in-house made Pinnacle scripts both in sampling and scoring. In addition, dosimetry analysis and physician's opinion are also performed as the supplementary and compared with the result of PQM.
RESULTS:
It is revealed by the numerical analysis of PQM scores that only 15% patients whose superior trials evaluated by PQM are also the initial trials. Gantry optimization can bring benefit to plan quality along with auto-planning in liver cancer. Similar results are provided by both dose comparison and physician's opinion.
CONCLUSIONS
It is possible to introduce a full automated approach of beam angle optimization to automated planning process. The advantages of this procedure can be observed both in numerical analysis and physician's opinion.
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Feasibility Studies
;
Radiometry/methods*
;
Liver Neoplasms/radiotherapy*
;
Radiotherapy, Intensity-Modulated/methods*
;
Radiotherapy Dosage
7.Structural Design and Penumbra Analysis of Dynamic Multi-leaf Collimator Leaf End.
Jun LYU ; Liuli CHEN ; Ruijun WEN ; Pengcheng LONG ; Leiming SHANG ; Liqin HU
Chinese Journal of Medical Instrumentation 2023;47(4):377-382
Dynamic multi-leaf collimator, which has the function of radiation beam shaping, is a key executive component of tumor precise radiotherapy, and plays a core role in improving the accuracy, efficiency and quality of radiotherapy. A new type of collimator leaf end structure with circular arc and plane combination was studied, and collimator penumbra performance analysis model combining analytical expression and graphic analysis was developed. The influence of leaf end structure on penumbra was analyzed quantitatively, and a set of three-dimensional structure design of dynamic multi-leaf collimator was completed. The feasibility of the structural design and analysis model was verified through experimental measurements.
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Particle Accelerators
;
Neoplasms
;
Radiotherapy Dosage
8.Analysis of risk factors of radiation-induced toxicity in limited-stage small cell lung cancer treated with hypofractionated intensity-modulated radiotherapy.
Jing Jing ZHAO ; Nan BI ; Tao ZHANG ; Jian Yang WANG ; Lei DENG ; Xin WANG ; Dong Fu CHEN ; Jian Rong DAI ; Luhua WANG
Chinese Journal of Oncology 2023;45(7):627-633
Objective: To compare the incidence of radiation-related toxicities between conventional and hypofractionated intensity-modulated radiation therapy (IMRT) for limited-stage small cell lung cancer (SCLC), and to explore the risk factors of hypofractionated radiotherapy-induced toxicities. Methods: Data were retrospectively collected from consecutive limited-stage SCLC patients treated with definitive concurrent chemoradiotherapy in Cancer Hospital of Chinese Academy of Medical Sciences from March 2016 to April 2022. The enrolled patients were divided into two groups according to radiation fractionated regimens. Common Terminology Criteria for Adverse Events (CTCAE, version 5.0) was used to evaluate the grade of radiation esophagus injuries and lung injuries. Logistic regression analyses were used to identify factors associated with radiation-related toxicities in the hypofractionated radiotherapy group. Results: Among 211 enrolled patients, 108 cases underwent conventional IMRT and 103 patients received hypofractionated IMRT. The cumulative incidences of acute esophagitis grade ≥2 [38.9% (42/108) vs 35.0% (36/103), P=0.895] and grade ≥ 3 [1.9% (2/108) vs 5.8% (6/103), P=0.132] were similar between conventional and hypofractionated IMRT group. Late esophagus injuries grade ≥2 occurred in one patient in either group. No differences in the cumulative incidence of acute pneumonitis grade ≥2[12.0% (13/108) vs 5.8% (6/103), P=0.172] and late lung injuries grade ≥2[5.6% (6/108) vs 10.7% (11/103), P=0.277] were observed. There was no grade ≥3 lung injuries occurred in either group. Using multiple regression analysis, mean esophageal dose ≥13 Gy (OR=3.33, 95% CI: 1.23-9.01, P=0.018) and the overlapping volume between planning target volume (PTV) and esophageal ≥8 cm(3)(OR=3.99, 95% CI: 1.24-12.79, P=0.020) were identified as the independent risk factors associated with acute esophagitis grade ≥2 in the hypofractionated radiotherapy group. Acute pneumonitis grade ≥2 was correlated with presence of chronic obstructive pulmonary disease (COPD, P=0.025). Late lung injuries grade ≥2 was correlated with tumor location(P=0.036). Conclusions: Hypofractionated IMRT are tolerated with manageable toxicities for limited-stage SCLC patients treated with IMRT. Mean esophageal dose and the overlapping volume between PTV and esophageal are independently predictive factors of acute esophagitis grade ≥2, and COPD and tumor location are valuable factors of lung injuries for limited-stage SCLC patients receiving hyofractionated radiotherapy. Prospective studies are needed to confirm these results.
Humans
;
Small Cell Lung Carcinoma/pathology*
;
Lung Neoplasms/pathology*
;
Radiotherapy, Intensity-Modulated/methods*
;
Retrospective Studies
;
Lung Injury
;
Radiotherapy Dosage
;
Radiation Injuries/epidemiology*
;
Esophagitis/epidemiology*
;
Risk Factors
;
Pulmonary Disease, Chronic Obstructive/complications*
9.Dosimetric Impact of Titanium Alloy Implant in Spinal IMRT Plan.
Xiaohui CHEN ; Anjie XU ; Jiayan CHEN ; Weigang HU ; Jiayuan PENG
Chinese Journal of Medical Instrumentation 2023;47(1):110-114
The purpose of this study is to establish and apply a correction method for titanium alloy implant in spinal IMRT plan, a corrected CT-density table was revised from normal CT-density table to include the density of titanium alloy implant. Dose distribution after and before correction were calculated and compared to evaluate the dose deviation. Plans were also copied to a spinal cancer simulation phantom. A titanium alloy fixation system for spine was implanted in this phantom. Plans were recalculated and compared with the measurement result. The result of this study shows that the max dose of spinal cord showed significant difference after correction, and the deviation between calculation results and measurement results was reduced after correction. The method for expanding the range CT-density table, which means that the density of titanium alloy was included, can reduce the error in calculation.
Radiotherapy, Intensity-Modulated/methods*
;
Titanium
;
Radiotherapy Dosage
;
Alloys
;
Radiometry/methods*
;
Radiotherapy Planning, Computer-Assisted/methods*
10.Study on the sensitivity of a volumetric modulated arc therapy plan verification equipment on multi-leaf collimator opening and closing errors and its gamma pass rate limit.
Jinyou HU ; Lian ZOU ; Shaoxian GU ; Ningyu WANG ; Fengjie CUI ; Shengyuan ZHANG ; Chu'ou YIN ; Yunzhu CAI ; Chengjun GOU ; Zhangwen WU
Journal of Biomedical Engineering 2023;40(1):133-140
To investigate the γ pass rate limit of plan verification equipment for volumetric modulated arc therapy (VMAT) plan verification and its sensitivity on the opening and closing errors of multi-leaf collimator (MLC), 50 cases of nasopharyngeal carcinoma VMAT plan with clockwise and counterclockwise full arcs were randomly selected. Eight kinds of MLC opening and closing errors were introduced in 10 cases of them, and 80 plans with errors were generated. Firstly, the plan verification was conducted in the form of field-by-field measurement and true composite measurement. The γ analysis with the criteria of 3% dose difference, distance to agreement of 2 mm, 10% dose threshold, and absolute dose global normalized conditions were performed for these fields. Then gradient analysis was used to investigate the sensitivity of field-by-field measurement and true composite measurement on MLC opening and closing errors, and the receiver operating characteristic curve (ROC) was used to investigate the optimal threshold of γ pass rate for identifying errors. Tolerance limits and action limits for γ pass rates were calculated using statistical process control (SPC) method for another 40 cases. The error identification ability using the tolerance limit calculated by SPC method and the universal tolerance limit (95%) were compared with using the optimal threshold of ROC. The results show that for the true composite measurement, the clockwise arc and the counterclockwise arc, the descent gradients of the γ passing rate with per millimeter MLC opening error are 10.61%, 7.62% and 6.66%, respectively, and the descent gradients with per millimeter MLC closing error are 9.75%, 7.36% and 6.37%, respectively. The optimal thresholds obtained by the ROC method are 99.35%, 97.95% and 98.25%, respectively, and the tolerance limits obtained by the SPC method are 98.98%, 97.74% and 98.62%, respectively. The tolerance limit calculated by SPC method is close to the optimal threshold of ROC, both of which could identify all errors of ±2 mm, while the universal tolerance limit can only partially identify them, indicating that the universal tolerance limit is not sensitive on some large errors. Therefore, considering the factors such as ease of use and accuracy, it is suggested to use the true composite measurement in clinical practice, and to formulate tolerance limits and action limits suitable for the actual process of the institution based on the SPC method. In conclusion, it is expected that the results of this study can provide some references for institutions to optimize the radiotherapy plan verification process, set appropriate pass rate limit, and promote the standardization of plan verification.
Humans
;
Radiotherapy, Intensity-Modulated
;
Immune Tolerance
;
Nasopharyngeal Carcinoma
;
ROC Curve
;
Nasopharyngeal Neoplasms/radiotherapy*


Result Analysis
Print
Save
E-mail