1.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
2.Socioecological factors influencing sugar-sweetened beverage consumption among adolescents in South Korea: a cross-sectional study
Child Health Nursing Research 2025;31(1):28-39
Purpose:
This study explored the intrapersonal, interpersonal, and school factors, following the socioecological model, associated with sugar-sweetened beverage (SSB) consumption in Korean high-school students.
Methods:
A total of 231 students from first to third grade, aged 15–18 years, participated in this cross-sectional study. Multiple linear regression analysis was conducted to identify the factors.
Results:
Among the intrapersonal factors, fast-food consumption (β=0.13, t=1.97, p=.050) and habit strength of SSB consumption were positively associated (β=0.35, t=4.30, p<.001), and sleep duration was negatively associated with SSB consumption (β=–0.14, t=–2.02, p=.045). Among interpersonal factors, perceived SSB consumption by peers was positively associated (β=0.30, t=4.93, p<.001), and among school factors, vending machines at school (β=0.13, t=2.07, p=.039) and supermarkets and convenience stores near schools were positively associated with SSB consumption (β=0.17, t=2.87, p=.005).
Conclusion
School nurses should propose policies and interventions that consider the multilevel factors to reduce SSB consumption in adolescents.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.Socioecological factors influencing sugar-sweetened beverage consumption among adolescents in South Korea: a cross-sectional study
Child Health Nursing Research 2025;31(1):28-39
Purpose:
This study explored the intrapersonal, interpersonal, and school factors, following the socioecological model, associated with sugar-sweetened beverage (SSB) consumption in Korean high-school students.
Methods:
A total of 231 students from first to third grade, aged 15–18 years, participated in this cross-sectional study. Multiple linear regression analysis was conducted to identify the factors.
Results:
Among the intrapersonal factors, fast-food consumption (β=0.13, t=1.97, p=.050) and habit strength of SSB consumption were positively associated (β=0.35, t=4.30, p<.001), and sleep duration was negatively associated with SSB consumption (β=–0.14, t=–2.02, p=.045). Among interpersonal factors, perceived SSB consumption by peers was positively associated (β=0.30, t=4.93, p<.001), and among school factors, vending machines at school (β=0.13, t=2.07, p=.039) and supermarkets and convenience stores near schools were positively associated with SSB consumption (β=0.17, t=2.87, p=.005).
Conclusion
School nurses should propose policies and interventions that consider the multilevel factors to reduce SSB consumption in adolescents.
5.Socioecological factors influencing sugar-sweetened beverage consumption among adolescents in South Korea: a cross-sectional study
Child Health Nursing Research 2025;31(1):28-39
Purpose:
This study explored the intrapersonal, interpersonal, and school factors, following the socioecological model, associated with sugar-sweetened beverage (SSB) consumption in Korean high-school students.
Methods:
A total of 231 students from first to third grade, aged 15–18 years, participated in this cross-sectional study. Multiple linear regression analysis was conducted to identify the factors.
Results:
Among the intrapersonal factors, fast-food consumption (β=0.13, t=1.97, p=.050) and habit strength of SSB consumption were positively associated (β=0.35, t=4.30, p<.001), and sleep duration was negatively associated with SSB consumption (β=–0.14, t=–2.02, p=.045). Among interpersonal factors, perceived SSB consumption by peers was positively associated (β=0.30, t=4.93, p<.001), and among school factors, vending machines at school (β=0.13, t=2.07, p=.039) and supermarkets and convenience stores near schools were positively associated with SSB consumption (β=0.17, t=2.87, p=.005).
Conclusion
School nurses should propose policies and interventions that consider the multilevel factors to reduce SSB consumption in adolescents.
6.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
7.Radiographic Analysis of Scoliosis Using Convolutional Neural Network in Clinical Practice
Ha Yun OH ; Tae Kun KIM ; Yun Sun CHOI ; Mira PARK ; Ra Gyoung YOON ; Jin Kyung AN
Journal of the Korean Society of Radiology 2024;85(5):926-936
Purpose:
To assess the reliability and accuracy of an automated Cobb angle measurement (ACAM) using a convolutional neural network (CNN) for scoliosis evaluation and to compare measurement times.
Materials and Methods:
ACAM was applied to spine radiographs in 411 patients suspected of scoliosis. Observer 1 (consensus of two musculoskeletal radiologists) and observer 2 (a radiology resident) measured Cobb angle (CA). CA measurements were categorized using observer 1’s measurements as the reference standard. Inter-observer reliability and correlation were assessed using intraclass correlation coefficient (ICC) and Spearman’s rank correlation coefficient, respectively. Accuracy and measurement time of ACAM and observers were evaluated.
Results:
ACAM demonstrated excellent reliability and very high correlation with observer 1 (ICC = 0.976, Spearman’s rank correlation = 0.948), with a mean CA difference of 1.1. Overall accuracy was high (88.2%), particularly in mild (92.2%) and moderate (96%) scoliosis. Accuracy was lower in spinal asymmetry (77.1%) and higher in severe scoliosis (95%), although the CA was lower compared to the observers. ACAM significantly reduced measurement time by nearly half compared to the observers (p < 0.001).
Conclusion
ACAM using CNN enhances CA measurement for assessing mild or moderate scoliosis, despite limitations in spinal asymmetry or severe scoliosis. Nonetheless, it substantially decreases measurement time.
8.Radiographic Analysis of Scoliosis Using Convolutional Neural Network in Clinical Practice
Ha Yun OH ; Tae Kun KIM ; Yun Sun CHOI ; Mira PARK ; Ra Gyoung YOON ; Jin Kyung AN
Journal of the Korean Society of Radiology 2024;85(5):926-936
Purpose:
To assess the reliability and accuracy of an automated Cobb angle measurement (ACAM) using a convolutional neural network (CNN) for scoliosis evaluation and to compare measurement times.
Materials and Methods:
ACAM was applied to spine radiographs in 411 patients suspected of scoliosis. Observer 1 (consensus of two musculoskeletal radiologists) and observer 2 (a radiology resident) measured Cobb angle (CA). CA measurements were categorized using observer 1’s measurements as the reference standard. Inter-observer reliability and correlation were assessed using intraclass correlation coefficient (ICC) and Spearman’s rank correlation coefficient, respectively. Accuracy and measurement time of ACAM and observers were evaluated.
Results:
ACAM demonstrated excellent reliability and very high correlation with observer 1 (ICC = 0.976, Spearman’s rank correlation = 0.948), with a mean CA difference of 1.1. Overall accuracy was high (88.2%), particularly in mild (92.2%) and moderate (96%) scoliosis. Accuracy was lower in spinal asymmetry (77.1%) and higher in severe scoliosis (95%), although the CA was lower compared to the observers. ACAM significantly reduced measurement time by nearly half compared to the observers (p < 0.001).
Conclusion
ACAM using CNN enhances CA measurement for assessing mild or moderate scoliosis, despite limitations in spinal asymmetry or severe scoliosis. Nonetheless, it substantially decreases measurement time.
9.Radiographic Analysis of Scoliosis Using Convolutional Neural Network in Clinical Practice
Ha Yun OH ; Tae Kun KIM ; Yun Sun CHOI ; Mira PARK ; Ra Gyoung YOON ; Jin Kyung AN
Journal of the Korean Society of Radiology 2024;85(5):926-936
Purpose:
To assess the reliability and accuracy of an automated Cobb angle measurement (ACAM) using a convolutional neural network (CNN) for scoliosis evaluation and to compare measurement times.
Materials and Methods:
ACAM was applied to spine radiographs in 411 patients suspected of scoliosis. Observer 1 (consensus of two musculoskeletal radiologists) and observer 2 (a radiology resident) measured Cobb angle (CA). CA measurements were categorized using observer 1’s measurements as the reference standard. Inter-observer reliability and correlation were assessed using intraclass correlation coefficient (ICC) and Spearman’s rank correlation coefficient, respectively. Accuracy and measurement time of ACAM and observers were evaluated.
Results:
ACAM demonstrated excellent reliability and very high correlation with observer 1 (ICC = 0.976, Spearman’s rank correlation = 0.948), with a mean CA difference of 1.1. Overall accuracy was high (88.2%), particularly in mild (92.2%) and moderate (96%) scoliosis. Accuracy was lower in spinal asymmetry (77.1%) and higher in severe scoliosis (95%), although the CA was lower compared to the observers. ACAM significantly reduced measurement time by nearly half compared to the observers (p < 0.001).
Conclusion
ACAM using CNN enhances CA measurement for assessing mild or moderate scoliosis, despite limitations in spinal asymmetry or severe scoliosis. Nonetheless, it substantially decreases measurement time.
10.Impact of the COVID-19 Pandemic on Admission and Mortality Among Patients With Severe Emergency Diseases at Emergency Departments in Korea in 2020: Registry Data From the National Emergency Department Information System
Sun Kyoung NA ; Jeung-Hee KIM ; Weon-Young LEE ; Mi Ra OH
Journal of Korean Medical Science 2023;38(30):e243-
We aimed to investigate the impact of the coronavirus disease 2019 (COVID-19) pandemic on admissions of patients with acute myocardial infarction, stroke, and severe trauma, and their excess mortality in emergency departments (EDs) in South Korea using registry data from the National Emergency Department Information System (NEDIS) for patients attending EDs of regional and local emergency medical centers. During the outbreak period of 2020, there were 350,698 ED visits, which was lower than the total in 2019 (392,627 visits).Multiple logistic regression revealed that, compared with 2019, there was significantly higher ED mortality rate during the COVID-19 outbreak in 2020 (adjusted odds ratio, 1.10;95% confidence interval, 1.07–1.13). This finding implies that during the early outbreak period, people might have avoided seeking medical care even for acute and life-threatening conditions, or transfer times at the scene to the hospital arrival were delayed, or treatment for the patients in EDs were delayed.

Result Analysis
Print
Save
E-mail