1.Effects of dihydromyricetin on myocardial oxidative damage in exhaustive exercise mice
Ze-Hai SU ; Ling QIN ; Quan-Shui HAO ; Jia-Bao XU
The Chinese Journal of Clinical Pharmacology 2024;40(10):1443-1447
Objective To investigate the effect of dihydromyricetin(DMY)on myocardial oxidative damage in exhaustive exercise mice.Methods C57BL/6 mice were divided into control group,model group,positive control group and low,medium and high dose experimental groups and with 10 mice in each group.Mice in control group and model group were intragastricated with distilled water;20,40 and 80 mg·kg-1 dihydromyricetin were given by gavage in low,medium and high dose experimental groups,while mice in positive control group were intragastricated with 100 mg·kg-1 Vitamin C once a day for 4 weeks.After administration,superoxide dismutase(SOD),malondialdehyde(MDA)and lactate dehydrogenase(LDH)were detected by the kit.The expression of nuclear factor E2-related factor 2(Nrf2)and heme oxygenase-1(HO-1)protein were detected by Western blot.Results SOD levels in control group,model group and low,medium,high dose experimental groups and positive control group were(57.81±6.92),(26.85±2.74),(33.68±4.52),(39.74±3.95),(48.97±4.26)and(39.22±3.54)U·mg-1;MDA were(4.72±0.36),(10.48±1.68),(8.75±0.82),(6.43±0.71),(5.11±0.48)and(6.36±0.64)nmol·mg-1;LDH were(268.71±23.94),(726.58±81.26),(621.32±47.59),(479.12±50.24),(337.91±34.99)and(486.15±50.98)U·L-1;Nrf2 protein expression were 0.75±0.06,0.19±0.02,0.30±0.04,0.47±0.05,0.63±0.06 and 0.49±0.06;the protein expression of HO-1 were 0.83±0.08,0.27±0.05,0.39±0.04,0.52±0.03,0.77±0.07 and 0.55±0.06,respectively.There were statistically significant differences between control group and model group(all P<0.05);there were statistically significant differences in the above indexes between model group and positive control group,low dose experimental group,medium dose experimental group,high dose experimental group(all P<0.05).Conclusion Dihydromyricetin can delay myocardial oxidative injury in exhaustive exercise mice,which may be related to Nrf2/HO-1 pathway.
2.Effects of verbascoside on oxygen consumption and mitochondrial enzyme activities in skeletal muscle of rats during intense exercise
Ze-Hai SU ; Ling QIN ; Quan-Shui HAO
The Chinese Journal of Clinical Pharmacology 2024;40(14):2098-2102
Objective To investigate the effects of verbascoside on oxygen consumption and mitochondrial enzyme activities in skeletal muscle of rats with intense exercise.Methods Fifty SD rats were randomly divided into control group,model group,experimental-L,-M,-H groups.Exercise training was performed in all groups except the control group.The control group and model group were given 2 mL of 0.9%NaCl,the experimental-L,-M,-H groups was given 20,40,80 mg·kg-1·d-1 verbascoside.The activities of Na+/K+-ATP and Ca2+/Mg2+-ATP were detected by kit.Protein expressions of optic atrophy 1(Opa1),mitochondrial fusion(Mfn)1 and Mfn2 were detected by Western blot.Results The Na+/K+-ATP of experimental-L,-M,-H groups,model group and blank group were(2.74±0.44),(3.50±0.38),(4.39±0.41),(2.13±0.32)and(5.75±0.42)U·mg-1;Ca2+/Mg2+-ATP were(4.01±0.32),(4.82±0.79),(6.57±0.70),(3.51±0.35)and(8.92±1.14)U·mg-1;Opa-1 were 0.40±0.05,0.52±0.04,0.69±0.09,0.25±0.06 and 0.78±0.11;Mfn1 were 0.47±0.06,0.59±0.07,0.74±0.08,0.32±0.05 and 0.89±0.12;Mfn2 were 0.51±0.07,0.65±0.06,0.83±0.06,0.35±0.06 and 1.02±0.13,respectively.There was statistical significance between control group and model group(all P<0.05);there were statistically significant differences in the above indexes between the experimental-L,-M,-H groups and the model group(all P<0.05).Conclusion Verminoside can improve the oxygen consumption and mitochondrial enzyme activity of skeletal muscle and increase the antioxidant capacity of rats with intense exercise.
3.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
4.Treatment of C severe fracture and dislocation combined with cervical spinal cord injury by one stage reduction and internal fixation with anterior posterior approaches : a case report.
Jian-Quan CHEN ; Mao-Shui CHEN ; Bo ZHANG ; Hao-Bin CENG ; Luo-Qi MAI ; Wei-Yi XIA ; Hao LI
China Journal of Orthopaedics and Traumatology 2020;33(2):154-157
6.Spiral thermo-expandable prostatic stent implantation for benign prostatic hyperplasia: Clinical analysis of 26 cases.
Hao-Wei HE ; Xiao-Ming YI ; Song XU ; Le QU ; Shui-Gen ZHOU ; Zheng-Yu ZHANG ; Wen-Quan ZHOU ; Jing-Ping GE ; Song XUE
National Journal of Andrology 2019;25(5):414-419
Objective:
To investigate the surgical techniques and clinical effect of Memokath transurethral spiral thermo-expandable prostatic stent (STEPS) implantation in the treatment of BPH.
METHODS:
From January 2017 to January 2018, 26 BPH patients underwent Memokath transurethral STEPS implantation, 9 under the flexible cystoscope and the other 17 under the rigid cystoscope. The patients were aged 62-91 years old, with a prostate volume of 32-78 ml, postvoid residual urine volume (PVR) of (67.3 ± 11.2) ml, maximum urinary flow rate (Qmax) of (6.3 ± 1.8) ml/s, and IPSS score of 26.7 ± 5.7. Eight of the patients had preoperative urinary retention, of whom, 6 received catheterization and 2 had undergone cystostomy for bladder fistula before STEPS implantation.
RESULTS:
The operations lasted 15-30 minutes and were successfully completed in 24 cases while stent-shedding occurred in the other 2. Twenty-two of the patients achieved spontaneous urination immediately after surgery and 2 experienced bladder clot embolism. At 3 month after surgery, 24 of the patients showed significant improvement in PVR ([21.4 ± 7.7] ml), Qmax ([18.3 ± 4.7] ml/s) and IPSS (8.3 ± 2.1), and 13 exhibited no statistically significant difference from the baseline in the IIEF-5 score (14.1 ± 1.1 vs 14.3 ± 1.0, P > 0.05). At 12 months, all the patients were found with markedly improved urination but no adverse events except recurrent urinary tract infection in 2 cases.
CONCLUSIONS
Memokath STEPS implantation, with its advantages of simple operation, high safety, definite effectiveness, non-influence on sexual function, is a new effective surgical option for the treatment of BPH.
7.Research Progress of the Correlation between Caveolin and Unexpected Sudden Cardiac Death.
Fang Yu WU ; Lian Lei GAI ; Xiao Ping KONG ; Bo HAO ; Er Wen HUANG ; He SHI ; Li Hui SHENG ; Li QUAN ; Shui Ping LIU ; Bin LUO
Journal of Forensic Medicine 2017;33(3):284-288
Due to the negative autopsy and without cardiac structural abnormalities, unexpected sudden cardiac death (USCD) is always a tough issue for forensic pathological expertise. USCD may be associated with parts of fatal arrhythmic diseases. These arrhythmic diseases may be caused by disorders of cardiac ion channels or channel-related proteins. Caveolin can combine with multiple myocardial ion channel proteins through its scaffolding regions and plays an important role in maintaining the depolarization and repolarization of cardiac action potential. When the structure and function of caveolin are affected by gene mutations or abnormal protein expression, the functions of the regulated ion channels are correspondingly impaired, which leads to the occurrence of multiple channelopathies, arrhythmia or even sudden cardiac death. It is important to study the effects of caveolin on the functions of ion channels for exploring the mechanisms of malignant arrhythmia and sudden cardiac death.
Arrhythmias, Cardiac/physiopathology*
;
Autopsy
;
Caveolins/metabolism*
;
Channelopathies/genetics*
;
Death, Sudden, Cardiac/pathology*
;
Forensic Pathology
;
Humans
;
Ion Channels/metabolism*
;
Mutation
;
Myocardium
8.Correlation between Genetic Variants and Polymorphism of Caveolin and Sudden Unexplained Death.
Fang Yu WU ; Xin Hua TANG ; Lian Lei GAI ; Xiao Ping KONG ; Bo HAO ; Er Wen HUANG ; He SHI ; Li Hui SHENG ; Li QUAN ; Shui Ping LIU ; Bin LUO
Journal of Forensic Medicine 2017;33(2):114-119
OBJECTIVES:
To explore the genetic variation sites of caveolin (CAV) and their correlation with sudden unexplained death (SUD).
METHODS:
The blood samples were collected from SUD group (71 cases), coronary artery disease (CAD) group (62 cases) and control group (60 cases), respectively. The genome DNA were extracted and sequencing was performed directly by amplifying gene coding region and exon-intron splicing region of CAV1 and CAV3 using PCR. The type of heritable variation of CVA was confirmed and statistical analysis was performed.
RESULTS:
A total of 4 variation sites that maybe significative were identified in SUD group, and two were newfound which were CAV1: c.45C>T (T15T) and CAV1:c.512G>A (R171H), and two were SNP loci which were CAV1:c.246C>T (rs35242077) and CAV3:c.99C>T (rs1008642) and had significant difference (P<0.05) in allele and genotype frequencies between SUD and control groups. Forementioned variation sites were not found in CAD group.
CONCLUSIONS
The variants of CAV1 and CAV3 may be correlated with a part of SUD group.
Caveolins/genetics*
;
Coronary Artery Disease
;
Death, Sudden/etiology*
;
Exons
;
Genotype
;
Humans
;
Male
;
Polymerase Chain Reaction
;
Polymorphism, Single Nucleotide
9.Distribution of human enterovirus 71 in brainstem of infants with brain stem encephalitis and infection mechanism.
Bo HAO ; Di GAO ; Da-Wei TANG ; Xiao-Guang WANG ; Shui-Ping LIU ; Xiao-Ping KONG ; Chao LIU ; Jing-Lu HUANG ; Qi-Ming BI ; Li QUAN ; Bin LUO
Journal of Forensic Medicine 2012;28(2):85-91
OBJECTIVE:
To explore the mechanism that how human enterovirus 71 (EV71) invades the brainstem and how intercellular adhesion molecules-1 (ICAM-1) participates by analyzing the expression and distribution of human EV71, and ICAM-1 in brainstem of infants with brain stem encephalitis.
METHODS:
Twenty-two brainstem of infants with brain stem encephalitis were collected as the experimental group and 10 brainstems of fatal congenital heart disease were selected as the control group. The sections with perivascular cuffings were selected to observe EV71-VP1 expression by immunohistochemistry method and ICAM-1 expression was detected for the sections with EV71-VP1 positive expression. The staining image analysis and statistics analysis were performed. The experiment and control groups were compared.
RESULTS:
(1) EV71-VP1 positive cells in the experimental group were mainly astrocytes in brainstem with [dark]-brown particles, and the control group was negative. (2) ICAM-1 positive cells showed [dark]-brown. The expression in inflammatory cells (around blood vessels of brain stem and in glial nodules) and gliocytes increased. The results showed statistical difference comparing with control group (P < 0.05).
CONCLUSION
The brainstem encephalitis can be used to diagnose fatal EV71 infection in infants. EV71 can invade the brainstem via hematogenous route. ICAM-1 may play an important role in the pathogenic process.
Astrocytes/pathology*
;
Brain Stem/virology*
;
Case-Control Studies
;
Encephalitis, Viral/virology*
;
Enterovirus A, Human/metabolism*
;
Female
;
Hand, Foot and Mouth Disease/virology*
;
Humans
;
Immunohistochemistry
;
Infant
;
Intercellular Adhesion Molecule-1/metabolism*
;
Male
10.Application of serum total IgE, tryptase and chymase in the identification of death caused by drug anaphylactic shock.
Hong-jie WANG ; Wei-ping SONG ; Yu YANG ; Jing-lu HUANG ; Bo HAO ; Di GAO ; Da-wang TANG ; Xiao-guang WANG ; Shui-ping LIU ; Li QUAN ; Bin LUO
Journal of Forensic Medicine 2012;28(3):167-171
OBJECTIVE:
To explore the application value of serum total IgE, tryptase and chymase in the identification of death caused by drug anaphylactic shock.
METHODS:
The general information from 235 cases of non-drug anaphylactic shock and 32 cases of drug anaphylactic shock were analyzed. The serum IgE level had been detected in the cases. Ten cases caused by coronary disease and 10 cases caused by sudden manhood death syndrome were selected from non-drug anaphylactic shock cases for the control group. Expressions of tryptase and chymase in the lung and heart were detected using immunohistochemistry method. The number and IOD of positive mast cells were counted.
RESULTS:
In the drug anaphylactic shock group, the IgE value of 18 samples (56.25%) was significantly higher than the normal upper limit of 120 IU/mL. In the non-drug anaphylactic shock group, the IgE value of 67 samples (28.51%) was higher than 120 IU/mL. The expressions of tryptase and chymase were significantly increased in lung and myocardial tissue in drug anaphylactic shock group (P < 0.05).
CONCLUSION
Tryptase and chymase are more superior than that of the serum total IgE in the diagnosis of death caused by drug anaphylactic shock, and are more suitable in forensic practice.
Adolescent
;
Adult
;
Aged
;
Anaphylaxis/pathology*
;
Autopsy
;
Case-Control Studies
;
Cause of Death
;
Child
;
Child, Preschool
;
Chymases/metabolism*
;
Death, Sudden, Cardiac/pathology*
;
Drug Hypersensitivity
;
Female
;
Forensic Pathology
;
Humans
;
Immunoglobulin E/blood*
;
Immunohistochemistry
;
Infant
;
Lung/pathology*
;
Male
;
Middle Aged
;
Myocardium/pathology*
;
Tryptases/metabolism*
;
Young Adult

Result Analysis
Print
Save
E-mail