Objective To study the five-year survival status and influencing factors of elderly patients with lung cancer complicated with chronic obstructive pulmonary disease (COPD). Methods A cohort study was conducted to follow up 450 patients with lung cancer and chronic obstructive pulmonary disease who were hospitalized in our hospital from January 2018 to December 2023. The endpoint of the follow-up was the end of a five-year period or death. The Life Tables method was used to calculate survival rates and plot survival curves. The Cox proportional hazards model was used to analyze the influencing factors of five-year survival. Results The results indicated that the overall five-year survival rate of patients was 4.89%, and it decreased year by year. Cox regression analysis showed that age, gender, family functioning, and psychological status significantly influenced patient survival rate (all P<0.05). Stratified analysis found that the smoking status, family functioning, and psychological status of male patients all had an impact on survival rate (all P<0.05), while the psychological status of female patients had a more significant impact on survival (P=0.008). Conclusion This study provides a scientific basis for comprehensive intervention of elderly lung cancer patients with COPD. It is recommended that clinical attention should be paid to psychological and family factors to improve patient prognosis.
2.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
3.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
4.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
5.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
6.Evaluation and application of automated quality control of automatic pipeline in clinical biochemical and immunological detection
Li′an HOU ; Xuesong SHANG ; Chaochao MA ; Liangyu XIA ; Li LIU ; Ying ZHANG ; Yujun SU ; Xin LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2024;47(1):86-93
Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.
7.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
8.Study on anti-myocardial ischemia active components and mechanism of Xinkeshu tablets based on network pharmacology and zebrafish model
Lin-Hua HOU ; Hua-Zheng ZHANG ; Shuo GAO ; Yun ZHANG ; Qiu-Xia HE ; Ke-Chun LIU ; Chen SUN ; Jian-Heng LI ; Qing XIA
Chinese Pharmacological Bulletin 2024;40(5):964-974
Aim To study the active ingredients and mechanism of action of Xinkeshu tablets against myo-cardial ischemia by network pharmacology and ze-brafish model.Methods The anti-myocardial ische-mia activity of Xinkeshu tablets was evaluated by iso-prenaline hydrochloride(ISO)-induced zebrafish myo-cardial ischemia model and H2O2-induced H9c2 dam-age model.The active ingredients of Xinkeshu tablets were retrieved using databases such as TCMSP.The potential targets were predicted by PharmaMapper data-base.Myocardial ischemic disease targets were searched by OMIM database.The potential therapeutic targets of Xinkeshu tablets against myocardial ischemia were analyzed.GO and KEGG enrichment analysis were conducted on core targets.The active ingredients were verified by zebrafish and cell model.qRT-PCR was used to detect the expression of key targets.Re-sults Xinkeshu tablets could significantly alleviate ISO-induced pericardial edema and bradycardia.It al-so could increase sinus venous-bulb aortic(SV-BA)distance and improve the cell viability.The 30 poten-tial active ingredients of Xinkeshu tables mainly acted on 30 core targets,including ALB,AKT1 and MAPK1,to regulate 627 GO items,including protein phosphorylation,negative regulation of apoptosis and positive regulation of PI3K signal transduction.KEGG results showed that 117 signaling pathways,including PI3K/Akt,FOXO and Ras,exerted anti-myocardial ischemia effect.Salvianolic acid A,lithospermic acid,rosmarinic acid,salvianolic acid D,salvianolic acid B,ginsenoside Rg2,hyperoside,3'-methoxypuerarin,3'-hydroxypuerarin and ginsenoside Rg1 could alleviate ISO-induced zebrafish myocardial ischemia and im-prove the cell viability.Xinkeshu tablets could upregu-late the expression of genes such as ras and akt1,and downregulate the expression of genes such as mapk1 and mapk8.Conclusion The active ingredients,in-cluding salvianolic acid A in Xinkeshu tablets,exert anti-myocardial ischemia effects by targeting targets,such as AKT1,MAPK1,and regulating signaling path-ways,such as PI3K/Akt,MAPK and Ras.
9.Baimai Ointment relieves chronic pain induced by chronic compression of dorsal root ganglion in rats by regulating neuroactive ligand-receptor interaction and HIF-1 signaling pathway.
Fang-Ting ZHOU ; Ying ZONG ; Wu-Qiong HOU ; Sen-Sen LI ; Fei YANG ; Li-Ting XU ; Xia MAO ; Yu-Dong LIU ; Xiao-Hui SU ; Hong-Ye WAN ; Jing-Feng OUYANG ; Qiu-Yan GUO ; Wei-Jie LI ; Zhen WANG ; Chao WANG ; Na LIN
China Journal of Chinese Materia Medica 2023;48(23):6457-6474
The Baimai Ointment with the effect of relaxing sinew and activating collaterals demonstrates a definite effect on Baimai disease with pain, spasm, stiffness and other symptoms, while the pharmacodynamic characteristics and mechanism of this agent remain unclear. In this study, a rat model of chronic compression of L4 dorsal root ganglion(CCD) was established by lumbar disc herniation, and the efficacy and mechanism of Baimai Ointment in the treatment of CCD were preliminarily explored by behavioral tests, side effect evaluation, network analysis, antagonist and molecular biology verification. The pharmacodynamic experiment indicated that Baimai Ointment significantly improved the pain thresholds(mechanical pain, thermal pain, and cold pain) and gait behavior of CCD model rats without causing tolerance or obvious toxic and side effects. Baimai Ointment inhibited the second-phase nociceptive response of mice in the formalin test, increased the hot plate threshold of normal mice, and down-regulated the expression of inflammatory cytokines in the spinal cord. Network analysis showed that Baimai Ointment had synergistic effect in the treatment of CCD and was related to descending inhibition/facilitation system and neuroinflammation. Furthermore, behavioral tests, Western blot, and immunofluorescence assay revealed that the pain-relieving effect of Baimai Ointment on CCD may be related to the regulation of the interaction between neuroactive ligand and receptors(neuroligands) such as CHRNA7, ADRA2A, and ADRB2, and the down-regulation of the expression of NOS2/pERK/PI3K, the core regulatory element of HIF-1 signaling pathway in spinal microglia. The findings preliminarily reveal the mechanism of relaxing sinew and activating collaterals of Baimai Ointment in the treatment of Baimai disease, providing a reference for the rational drug use and further research of this agent.
Rats
;
Mice
;
Animals
;
Chronic Pain/metabolism*
;
Rats, Sprague-Dawley
;
Ganglia, Spinal/metabolism*
;
Ligands
;
Signal Transduction
;
Hyperalgesia/metabolism*
;
Drugs, Chinese Herbal
10.Experts consensus on the procedure of dental operative microscope in endodontics and operative dentistry.
Bin LIU ; Xuedong ZHOU ; Lin YUE ; Benxiang HOU ; Qing YU ; Bing FAN ; Xi WEI ; Lihong QIU ; Zhengwei HUANG ; Wenwei XIA ; Zhe SUN ; Hanguo WANG ; Liuyan MENG ; Bin PENG ; Chen ZHANG ; Shuli DENG ; Zhaojie LU ; Deqin YANG ; Tiezhou HOU ; Qianzhou JIANG ; Xiaoli XIE ; Xuejun LIU ; Jiyao LI ; Zuhua WANG ; Haipeng LYU ; Ming XUE ; Jiuyu GE ; Yi DU ; Jin ZHAO ; Jingping LIANG
International Journal of Oral Science 2023;15(1):43-43
The dental operative microscope has been widely employed in the field of dentistry, particularly in endodontics and operative dentistry, resulting in significant advancements in the effectiveness of root canal therapy, endodontic surgery, and dental restoration. However, the improper use of this microscope continues to be common in clinical settings, primarily due to operators' insufficient understanding and proficiency in both the features and established operating procedures of this equipment. In October 2019, Professor Jingping Liang, Vice Chairman of the Society of Cariology and Endodontology, Chinese Stomatological Association, organized a consensus meeting with Chinese experts in endodontics and operative dentistry. The objective of this meeting was to establish a standard operation procedure for the dental operative microscope. Subsequently, a consensus was reached and officially issued. Over the span of about four years, the content of this consensus has been further developed and improved through practical experience.
Humans
;
Dentistry, Operative
;
Consensus
;
Endodontics
;
Root Canal Therapy
;
Dental Care


Result Analysis
Print
Save
E-mail